AEMC 5070 User manual

www. .com information@itm.com1.800.561.8187

Copyright © Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments. All rights reserved.
No part of this documentation may be reproduced in any form or by any means (including electronic
storage and retrieval or translation into any other language) without prior agreement and written consent
from Chauvin Arnoux®, Inc., as governed by United States and International copyright laws.
This documentation is provided “as is,” without warranty of any kind, express, implied, or otherwise.
Chauvin Arnoux®
but does not warrant the accuracy or completeness of the text, graphics, or other information contained
in this documentation. Chauvin Arnoux®, Inc. shall not be liable for any damages, special, indirect,
user of the documentation has been advised of the possibility of such damages.
www. .com information@itm.com1.800.561.8187

www. .com information@itm.com1.800.561.8187

TABLE OF CONTENTS
1. INTRODUCTION ................................................................................ 6
1.1 PRECAUTIONS FOR USE ........................................................ 7
1.2 RECEIVING YOUR SHIPMENT................................................ 7
1.3 ORDERING INFORMATION ..................................................... 8
1.3.1 Accessories and Replacement Parts ............................................. 8
1.4 ACCESSORY INFORMATION .................................................. 8
1.4.1 DataView® Software ....................................................................... 8
2. PRODUCT FEATURES...................................................................... 9
2.1 DESCRIPTION ........................................................................... 9
2.1.1 Control Features ..........................................................................10
2.2 DISPLAY FEATURES .............................................................. 12
3. SPECIAL FUNCTIONS .................................................................... 13
3.1 SET-UP FUNCTION ................................................................. 13
..................................................................13
..........................................14
3.1.3 SET-UP Menu ..............................................................................21
3.2 MODE / PRINT BUTTON ......................................................... 22
3.2.1 Primary Function - MODE............................................................22
3.2.2 Secondary Function - PRINT .......................................................26
3.3 DISPLAY / GRAPH BUTTON .................................................. 26
3.3.1 Primary Function - DISPLAY........................................................26
3.3.2 Secondary Function - GRAPH .....................................................39
.................................................................. 39
..................................................................39
3.4.2 Secondary Function - TEMP........................................................39
........................................................... 41
...................................................................41
3.5.2 Secondary Function - SMOOTH ..................................................41
............................................................... 42
...................................................................42
3.6.2 Secondary Function - ALARM......................................................42
BUTTON ...................................................................... 42
...................................................................42
3.7.2 Secondary Function - ............................................................42
3.8 MEM / MR BUTTON ................................................................. 42
3.8.1 Primary Function - MEM (Save)...................................................42
3.8.2 Second Function - MR (Recall)....................................................44
www. .com information@itm.com1.800.561.8187

3.9 CLEARING THE MEMORY ..................................................... 44
.................... 46
3.11 MAXIMUM OUTPUT VOLTAGE ............................................ 47
3.12 LIST OF ERROR CODES...................................................... 47
4. MEASUREMENT FUNCTIONS....................................................... 48
4.1 AC/DC VOLTAGE ..................................................................... 48
4.2 INSULATION MEASUREMENT .............................................. 48
4.3 CAPACITANCE MEASUREMENT .......................................... 51
4.4 RESIDUAL CURRENT MEASUREMENT .............................. 51
5. OPERATION ..................................................................................... 52
5.1 PERFORMING MEASUREMENTS ........................................ 52
5.2 STEP FUNCTION MODE ........................................................ 53
5.3 OPERATION EXAMPLES........................................................ 55
6. DATAVIEW® SOFTWARE ................................................................ 57
6.1 INSTALLING DATAVIEW ......................................................... 57
6.2 MEGOHMMETER CONTROL PANEL .................................... 59
7. SPECIFICATIONS ............................................................................ 60
7.1 REFERENCE CONDITIONS ................................................... 60
7.2 VOLTAGE.................................................................................. 60
7.3 INSULATION RESISTANCE ................................................... 60
7.4 POWER SUPPLY ..................................................................... 65
7.5 ENVIRONMENTAL SPECIFICATIONS .................................. 65
7.6 MECHANICAL SPECIFICATIONS.......................................... 66
7.7 SAFETY SPECIFICATIONS.................................................... 66
7.8 VARIATIONS IN OPERATING RANGE .................................. 66
8. MAINTENANCE................................................................................ 67
8.1 RECHARGING THE BATTERY............................................... 67
8.2 FUSE REPLACEMENT............................................................ 67
8.3 CLEANING................................................................................ 67
8.4 STORAGE................................................................................. 68
8.5 REPAIR AND CALIBRATION .................................................. 68
8.6 TECHNICAL AND SALES ASSISTANCE ............................... 68
8.7 LIMITED WARRANTY.............................................................. 69
8.8 WARRANTY REPAIRS ............................................................ 69
APPENDIX A. UTILIZING THE GUARD TERMINAL........................ 70
APPENDIX B. V DISTURBANCE/V OUTPUT FEATURE................. 72
www. .com information@itm.com1.800.561.8187

www. .com information@itm.com1.800.561.8187

www. .com information@itm.com1.800.561.8187

8Megohmmeter Model 5070
1.3 ORDERING INFORMATION
Megohmmeter Model 5070............................................................. Cat. #2130.30
Includes extra large tool bag, set of three 10 ft (5 kV) leads (red/black/blue with
clips), one guard terminal jumper lead, USB cable type B, US 115 V power cord,
rechargeable battery pack, and a USB stick with DataView® software and user
manual.
Cable – PC RS-232, DB9 F/F 6 ft Null Modem Cable
(For meters without USB Port) ..........................................................Cat. #2119.45
Cable – 5 ft USB A-B ........................................................................ Cat. #2140.46
Fuse – Set of 3, 0.1 A, 380 V, 5 x 20, .10 kA.....................................Cat. #2119.84
Bag – Extra Large Classic Tool Bag ................................................. Cat. #2133.73
Inverter – 12 VDC to 120 VAC, 200 Watt for Vehicle use................... Cat. #2135.43
Cable – Replacement 10 ft USB cable ............................................. Cat. #2136.80
Lead – Replacement set of 3, 10 ft (5 kV) Color-coded Safety
with Clips (JUMPER LEAD NOT INCLUDED).................................. Cat. #2151.30
Lead – Replacement 1 ft Jumper Lead ............................................ Cat. #2151.31
Lead – Set of 3, 25 ft (5 kV) Safety with Clips.................................. Cat. #2151.32
Battery – Rechargeable 9.6 V .......................................................... Cat. #2960.21
US 115 V Power Cord ...................................................................... Cat. #5000.14
1.4 ACCESSORY INFORMATION
®
Dataview® software makes it possible to:
Retrieve data from memory and plot graphs of the changes in insulation as a
function of the time over which the test voltage is applied, R(t).
Print out protocols of personalized tests, depending on the user’s needs.
Set up and control the instrument entirely by the USB serial port.
Check our Storefront at www.aemc.com/store for availability
www. .com information@itm.com1.800.561.8187

Megohmmeter Model 5070 9
2. PRODUCT FEATURES
2.1 DESCRIPTION
The Model 5070 megohmmeter is a top-of-the-line measuring instrument,
portable, in a rugged housing with a graphic display. It is capable of operating
from internal battery or line power.
Automatic detection and measurement of voltage/frequency/input current.
Quantitative and qualitative insulation measurement.
• Measurement at 500/1000/2500/5000 V or other test voltage between
40 and 5100 V (adjustable voltage).
• Measurement in voltage step mode (the applied voltage increases in steps).
• Automatic calculation of DAR, PI, and DD (dielectric discharge index)
quality ratios.
• Automatic calculation of measurement result referred to a reference
temperature.
Automatic capacitance measurement.
Automatic measurement of residual current.
This megohmmeter helps ensure the safety of electrical installations and
equipment. The operation is controlled by a microprocessor for data acquisition,
processing, display of measurements, and storage of results.
Advantages:
Automatic voltage measurement.
Automatic detection of external AC or DC voltages on the terminals, before
or during insulation measurements, disabling or stopping the measurements
when measurement accuracy is no longer guaranteed.
Threshold programming to trigger audible alarms.
Timer for measurement time checks.
Fuse protection of the instrument with detection and display of defective fuses.
Operator safety by automatic discharge of residual high voltage on the
equipment tested.
Automatic shutdown of the instrument to save battery power.
Battery charge indication.
Large backlit graphic display that is very easy to read.
Memory (128 kB), real time clock, and serial interface.
Control and programming of the instrument from a PC (using DataView software).
www. .com information@itm.com1.800.561.8187

10 Megohmmeter Model 5070
2.1.1 Control Features
1. Safety terminals: +, G, and -.
2. Protective fuse access.
3. AC power plug (direct operation on AC and battery recharge).
4. Back-lit liquid crystal display.
5. Communication port: USB port (9600 baud).
6. Rotary selector switch with 8 positions:
Instrument
OFF
Insulation measurement with selectable test voltage (from 40 to 5100
V: 10 V steps from 40 to 1000 V and 100 V steps from 1000 to 5000 V)
Insulation measurement with voltage step function (up to 5 steps
6
1
7
2
8
6
4
35
www. .com information@itm.com1.800.561.8187

Megohmmeter Model 5070 11
7. START/STOP button (starts and stops measurements).
8. Eight buttons with a primary and secondary function. The secondary functions
are highlighted in yellow italics below each button:
Button
Either selects a function or increases the parameter selected by the cursor.
Holding the button increases the rate of change for the parameter.
Either selects a function or decreases the parameter selected by the cursor.
Holding the button increases the rate of change for the parameter.
MEM Saves measured values.
MODE Before starting a test, the mode function allows selection of run time,
sample rate, DAR PI, and ratio times.
DISPLAY Browses through the screens accessible before, during, and after the
measurement
2nd Selects the second function of each button.
Button
ALARM Activates or deactivates the alarms programmed in SET-UP
SMOOTH Starts or stops the smoothing of displayed values during testing.
TEMP Activates temperature correction
Turns the display backlight ON or OFF
MR Recalls saved data
PRINT Printing measurement data is completed through DataView software.
GRAPH Browses through the screens accessible before, during, and after the
measurement
www. .com information@itm.com1.800.561.8187

12 Megohmmeter Model 5070
2.2 DISPLAY FEATURES
REMOTE
Indicates that the instrument is controlled remotely via the USB interface.
In this mode, the buttons and rotary switch are inactive, except for the OFF
position.
COM Flashes when data is transmitted to the serial interface. It is on continuously
if there is a problem in transmission.
2nd Indicates that the secondary function of a key will be used.
Indicates that the “programmed time test” mode was selected before the
measurement began.
DAR Indicates that the “automatic calculation of Dielectric Absorption Ratio” mode
was selected before the measurement was started.
PI Indicates that the “automatic calculation of Polarization Index” mode was
selected before the measurement was started.
DD Indicates that the “automatic calculation of “Dielectric Discharge Index”
mode was selected before the measurement was started.
SMOOTH Smooths the insulation measurement readings on the display for better visibility.
ALARM Indicates that the alarm is activated. An audible alarm will sound if the value
Indicates the remaining battery charge.
Indicates that the generated voltage is dangerous, V > 120 V .
Indicates that external voltage is present - this symbol is activated when the
Start button is pressed if V > 25 V .
www. .com information@itm.com1.800.561.8187

Megohmmeter Model 5070 13
3. SPECIAL FUNCTIONS
This function, located at the top rotary switch position (Blue “SET-UP” position),
llows:
www. .com information@itm.com1.800.561.8187

14 Megohmmeter Model 5070
DISPLAY CONTRAST
This function allows you to change the lightness and darkness of the display to
best suit the environment.
Range
0 to 255*
*The display is not legible above 130.
lighten or darken the display. The higher the number the lighter the display will
selection position.
ALARM SETTINGS
This function allows you to select a low insulation resistance value that will cause
an alarm symbol to appear on the display and will cause the buzzer to emit a
continuous tone when the measured insulation resistance falls below this value.
Voltage Range
500 V
1000 V
2500 V
5000 V
Adj. Voltage 1
Adj. Voltage 2
Adj. Voltage 3
screen displayed, you can adjust low limit resistance values for 500 V, 1000 V,
2500 V, 5000 V, or the three adjustable voltage positions.
the value at the blinking cursor position.
move the cursor again to the voltage selection part of the screen. You may now
To exit the alarm setting function, press the DISPLAY button. This will bring you
back to the top of the SET-UP menu.
www. .com information@itm.com1.800.561.8187

Megohmmeter Model 5070 15
ADJUSTABLE VOLTAGE 1, 2, 3
Measurement when the rotary switch is in the adjustable voltage position.
The values for this setting can be anywhere from 40 to 5100 volts adjustable in
10 or 100 volt increments.
Voltage Range
Adj. Voltage 1 40 to 5100 V
(in steps of 10 V from 40 to 1000 V)
(in steps of 100 V from 1000 to 5100 V)
Adj. Voltage 2
Adj. Voltage 3
Three adjustable settings are possible.
or decrement the value.
back to the parameter selection position.
This function lets you set a time from 1 minute to 49 hours and 59 minutes to run
an insulation resistance test.
The Model 5070 will automatically end the test at the end of the timed run.
Range
00 to 49 : 01 to 59
selection position.
Data from a timed run test can be stored in the Model 5070 at an interval you
select. This storage interval can be as fast as once every 10 seconds to as slow
as once every 10 minutes.
Range
00 to 10 : 10 to 59
www. .com information@itm.com1.800.561.8187

www. .com information@itm.com1.800.561.8187

Megohmmeter Model 5070 17
SET STEP FUNCTION 1, 2, 3
Step voltage testing can be a valuable tool in determining defective insulation or
used to dry out cables that have been penetrated by moisture.
to 5 voltage steps and dwell times from 1 minute to 9 hours and 59 minutes per
step.
Step Function Default Value Range
Voltage Duration (h:m) Voltage Duration (h:m)
h:m
40 to 5100 V
(in 10 V, then
100 V steps)
h:m
Step 1 50 V 00:01 00 to 09 : 01 to 59
Step 2 100 V 00:01 00 to 09 : 01 to 59
Step 3 150 V 00:01 00 to 09 : 01 to 59
Step 4 200 V 00:01 00 to 09 : 01 to 59
Step 5 250 V 00:01 00 to 09 : 01 to 59
Sample Time 00:01 (m:s) 00 to 59 : 00 to 59*
h:m
40 to 5100 V
(in 10 V, then
100 V steps)
h:m
Step 1 100 V 00:01 00 to 09 : 01 to 59
Step 2 300 V 00:01 00 to 09 : 01 to 59
Step 3 500 V 00:01 00 to 09 : 01 to 59
Step 4 700 V 00:01 00 to 09 : 01 to 59
Step 5 900 V 00:01 00 to 09 : 01 to 59
Sample Time 00:01 (m:s) 00 to 59 : 00 to 59*
h:m
40 to 5100 V
(in 10 V, then
100 V steps)
h:m
Step 1 1000 V 00:01 00 to 09 : 01 to 59
Step 2 2000 V 00:01 00 to 09 : 01 to 59
Step 3 3000 V 00:01 00 to 09 : 01 to 59
Step 4 4000 V 00:01 00 to 09 : 01 to 59
Step 5 5000 V 00:01 00 to 09 : 01 to 59
Sample Time 00:01 (m:s) 00 to 59 : 00 to 59*
*The minimum sample time is related to the total duration of the test (Total Run Time). It is
equal to: Sample Time (seconds) = (h+1)*5 where h= total run time in hours.
TEMPERATURE UNIT
This function toggles the display between Fahrenheit and Celsius scales for
temperature display.
Range
°C or °F
www. .com information@itm.com1.800.561.8187

18 Megohmmeter Model 5070
DEFAULT PROBE TEMPERATURE
With this function, you can program a default value for the temperature of the
device under test. This will be used when temperature correction is applied if no
value is programmed right after the test is conducted.
Range
+5 to +167°F
(-15 to +75°C)
Rc REFERENCE TEMPERATURE
Reference temperature to which the measurement result must be referred.
Range
+5 to +167°F
(-15 to +75°C)
Insulation resistance changes with temperature. The typical rule of thumb is that
for every 10°C increase in temperature the leakage current doubles and the
the equipment you will be testing. This value will be used when correcting results
to a reference temperature.
Range
+5 to +167°F
-15 to +75°C
selected for the present test.
MAXIMUM OUTPUT VOLTAGE
The Model 5070 provides the ability to limit the maximum test voltage to a
value you specify from 40 to 5100 V. When programmed, the instrument will not
generate a higher voltage to conduct the test even if the switch position indicates
a higher voltage. For example, if you set the maximum voltage to 1250 V and
place the rotary switch in the 5000 V position and start a test, the Model 5070 will
only output 1250 V.
Range
40 to 5100 V
www. .com information@itm.com1.800.561.8187

Megohmmeter Model 5070 19
SET DEFAULT PARAMETER
This function allows you to reset all the user programmable functions back to the
factory defaults.
CLEAR MEMORY
The clear memory function allows you to selectively erase individual tests or all
ensure that you don’t do this by accident.
the selected measurement voltage. If the V Disturbance exceeds the value of
the ratio, the instrument stops the test in process. If the voltage exceeding the
ratio is present at the device under test before the test is started, a test will not
be allowed to start. Three programmable values are: 3%, 10% and 20% of the
measurement voltage. The default is 3%.
If a test is to be performed at 1000 V and the V Disturbance / V Output
is set at 10%, the presence of 100 volts (1000 V * 10% = 100) before the test
starts will inhibit the test.
Range
3%, 10%, or 20%
BUZZER
The Model 5070 is equipped with a buzzer that will emit an audible tone when a
key is pressed, at regular intervals during a timed test, or continuously during an
Range
ON or OFF
POWER DOWN
5 minutes of no activity, if a timed test is not in progress. This function lets you
Range
ON or OFF
www. .com information@itm.com1.800.561.8187

20 Megohmmeter Model 5070
BAUD RATE
This function lets you program in the communication speed between the
Model 5070 and your computer. It must be set to 9600 for communication with
DataView.
desired baud rate. Your choices are 300, 600, 1200, 2400, 4800, 9600, or
complete the process.
Range
300 to 9600
UNITS
The Model 5070 can display the date in either US (m.d.y) or European (d.m.y)
fashion. This choice can be toggled here.
desired units to complete the process.
Range
Europe or USA
DATE
This function can set the day, month, and year values.
US format).
format or day for US format).
complete the process.
USA
dd.mm.yyyy mm.dd.yyyy
www. .com information@itm.com1.800.561.8187
Other manuals for 5070