Mixed-Signal Oscilloscope
(Logic Analyzer) Demonstration
16 integrated, time-aligned
channels • 2 GSa/s • 128 Mpts per channel
1. Connect probes and ground leads
from channel 1 and channel 2 to
corresponding test points provided.
2. Connect MSO cable from front of scope
to connector on demo board..
3. Turn the mode select knob to position
6 (SPI)
4. Press Default Setup
5. Press AutoScale to get the following
display of analog and digital channels:
Quick demo
Protocol Analyzer Demonstration
Time-aligned physical and protocol views •
Broadest support available •Industry’s only
multi-tab viewer on scope
Quick demo
1. Press Default Setup.
2. Press AutoScale.
3. Select Setup tab at the top of the screen
and select Serial Decode.
4. Choose Serial Decode from the menu
and select USB 2.0. Check the Show
Decode box and press AutoSetup to get
the following display.
5. Note that the payload value (which
contains coordinate information) changes
as you move the mouse. The blue cursor
on the waveform display is time-aligned
to the blue highlighted line in the decode
display.
6. Now let’s set up to trigger on a mouse
move. Highlight the Trigger tab at the top
of the screen and select Setup Trigger. In
the Type menu choose Data. Select the
Payload tab in the decode view and note
that the scope triggers and displays the
data each time the mouse is moved.
6. Note that the digital channels can be
grouped into buses if desired. Trigger
and decode are available across any
combination of analog and digital signals,
and the display is totally time-aligned.
7. Highlight the Setup tab at the top of
the screen and select Acquisition.
Select Segmented under Sampling
Mode. Manually enter 100 for the # of
segments. Close the box and press Run.
8. After all 100 segments are acquired,
use the Play menu at the bottom of the
screen to demonstrate stepping through
the acquisitions to note the differences.
For more information on Agilent Technologies’
products, applications or services, please
contact your local Agilent office. The
complete list is available at:
www.agilent.com/find/contactus
Americas
Canada (877) 894-4414
Latin America 305 269 7500
United States (800) 829-4444
Asia Pacific
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Thailand 1 800 226 008
Europe & Middle East
Austria 43 (0) 1 360 277 1571
Belgium 32 (0) 2 404 93 40
Denmark 45 70 13 15 15
Finland 358 (0) 10 855 2100
France 0825 010 700*
*0.125 €/minute
Germany 49 (0) 7031 464 6333
Ireland 1890 924 204
Israel 972-3-9288-504/544
Italy 39 02 92 60 8484
Netherlands 31 (0) 20 547 2111
Spain 34 (91) 631 3300
Sweden 0200-88 22 55
Switzerland 0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries:
www.agilent.com/find/contactus
Product specifications and descriptions in
this document subject to change without
notice.
October 1, 2009
© Agilent Technologies, Inc. 2011
Printed in USA, March 15, 2011
5990-3773EN