Airspan AirVelocity 1500 User manual

AirVelocity 1500 Installation Guide
Part Number: DUG01560
System Release: 16.5
Revision: A
Published: March 2019

© Copyright by Airspan Networks Ltd., 2018-2019. All rights reserved worldwide.
Legal Notices
The information contained within this document is proprietary, privileged and intended only for the recipient. As
such, the information is subject to all relevant copyright, patent and other laws protecting intellectual property, as
well as any specific agreements protecting Airspan Networks Ltd. rights in the aforesaid information. Neither this
document nor the information contained herein may be published, reproduced, transmitted or disclosed to third
parties, in whole or in part, without the express, prior, written permission of Airspan Networks Ltd. In addition, any
use of this document or the information contained herein for the purposes other than those for which it is disclosed
is strictly forbidden.
Airspan Networks Ltd. reserves the right, without prior notice or liability, to make changes in equipment design or
specifications.
Information supplied by Airspan Networks Ltd. is believed in good faith to be accurate and reliable, while every
care has been taken in preparing these documents. However, Airspan Networks Ltd. does not make any
representations and gives no warranties of whatever nature in respect of these documents, including without
limitation, the accuracy or completeness of any information, facts and/or opinions contained therein. No
responsibility is assumed by Airspan Networks Ltd. for the use of the documents nor for the rights of third parties
which may be effected in any way by the use thereof. The provision of these documents (and the documents
themselves) does not constitute professional advice of any kind. Any representation(s) in these documents
concerning performance of Airspan Networks Ltd. product(s) are for informational purposes only and are not
warranties of future performance, either expressed or implied. Airspan Networks Ltd., its affiliates, directors,
employees and agents shall not be held liable for any damages or losses, of any nature whatsoever, arising from
any use of and/or reliance on the documents.
These documents may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed
in relation thereto unless specifically undertaken in Airspan Networks Ltd. sales contract or order confirmation.
Information contained herein is periodically updated and changes will be incorporated into subsequent editions. If
you have encountered an error, please notify Airspan Networks Ltd.
Product performance figures quoted within this document are indicative and for information purposes only.
UK WEEE Registration number: WEEE/AB0207WZ. For more information, see WEEE Information for Airspan
Customers and Recyclers.
Acknowledgements
© Intel Corporation http://www.intel.com/
© Microsoft Corporation http://www.microsoft.com

DUG01560 Airspan Commercial and Internal Use i
Table of Contents
Document Information...............................................................................4
Abstract..................................................................................................................4
Revision History.....................................................................................................4
Warnings and Cautions.............................................................................2
Human Exposure to Radio Frequencies ................................................................2
Radio Interference..................................................................................................2
Modifications..........................................................................................................2
General..................................................................................................................2
Important Safety Instructions............................................................................2
Safety.....................................................................................................................2
Warning of Hazardous Voltages ............................................................................3
Adherence to European Directive 2014/53/EU ......................................................4
Warning Symbols...................................................................................................4
Service Information................................................................................................4
UL Information .......................................................................................................4
DECLARATION OF CONFORMITY .........................................................5
Maximum Output TX Total Power.............................................................7
Product Variants ....................................................................................................7
Power Consumption...............................................................................................7
LTE Antenna System.............................................................................................8
Integral Sectorial Antenna......................................................................................8
About This Document................................................................................9
Purpose..................................................................................................................9
Intended Audience.................................................................................................9
Document Conventions..........................................................................................9
Related Reading....................................................................................................9
Customer Care Help Desk ......................................................................10
Airspan Encourages Comments ..........................................................................10
1Introduction..........................................................................................11

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use ii
1.1 AirVelocity 1500 ............................................................................................11
2Getting Started.....................................................................................12
2.1 AirVelocity 1500 Installation Checklist...........................................................12
3Verifying Prerequisites.........................................................................13
3.1 Verifying Site Requirements..........................................................................13
3.2 Verify Installation Requirements....................................................................13
3.2.1 Verify the Tools............................................................................................13
3.2.2 Verify the Parts and Kits...............................................................................13
3.2.3 Power Supply...............................................................................................14
3.2.4 Verify Components.......................................................................................14
3.2.5 Physical Dimensions....................................................................................15
3.2.6 Environmental..............................................................................................16
4AirVelocity 1500 Installation ................................................................17
4.1 Ceiling Mount................................................................................................17
4.1.1 Suspended Ceiling Assembly.......................................................................17
4.1.2 Conventional Ceiling Assembly....................................................................21
4.2 Wall Mount Assembly....................................................................................23
4.3 LED Display ..................................................................................................25
5Connect and Manage Cables..............................................................26
5.1 DC Cable Connection....................................................................................26
5.2 Mounting the AC to POE++/DC Power Supply..............................................26
5.3 Ethernet Cable Installation............................................................................26
5.3.1 Copper Ethernet Cable.................................................................................26
5.3.2 Fiber Ethernet (SFP) Cable..........................................................................26
6GPS Antenna Mounting.......................................................................27
6.1 Verify the Parts and Kits................................................................................27
AJob Sheet.............................................................................................29
BChecklist ..............................................................................................30
CAbbreviations.......................................................................................31

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use iii
Figures
Figure 1: AirVelocity 1500................................................................................................................ 11
Figure 2: AirVelocity 1500 Ports (DC Variant) ..................................................................................15
Figure 3: Assemble Rail Brackets to the Unit ...................................................................................17
Figure 4: Assemble Rail Plates to the Mounting Plate......................................................................18
Figure 5: Ceiling Mounting Plate & Rails onto Ceiling Rails.............................................................. 18
Figure 6: Slide and Clinch the Rail Plates onto the Ceiling Rails.......................................................18
Figure 7: Engage the Rail Brackets Projections into the Ceiling Plate Slots......................................19
Figure 8: Swing Unit into Place and Insert the Locking Pin............................................................... 19
Figure 9: Insert and Click Close the Safety Cable ............................................................................19
Figure 10: Assemble Rail Brackets to the Unit .................................................................................21
Figure 11: Attach Mounting Bracket to Standard Ceiling...................................................................21
Figure 12: Mounting AirVelocity 1500 on Conventional Ceiling......................................................... 22
Figure 13: Insert & Secure Locking Pin............................................................................................22
Figure 14: Assemble Rail Brackets to the Unit .................................................................................23
Figure 15: Insert Anchors & Screws in Wall......................................................................................23
Figure 16: Insert Anchors & Screws in Wall......................................................................................24
Figure 17: Push Down to Engage Screw Heads...............................................................................24
Figure 18: DC Power Plug...............................................................................................................26
Figure 19: DC In - Panel..................................................................................................................26
Figure 20: GPS Antenna..................................................................................................................27
Tables
Table 1: AirVelocity 1500 ETSI / FCC Maximum Output TX Total Power............................................7
Table 2: Supported Frequency Bands................................................................................................7
Table 3: Power Consumption.............................................................................................................7
Table 4: Integral Sector Antenna Parameters (LTE)...........................................................................8
Table 5: Typographic Conventions.....................................................................................................9
Table 6. Minimum Hardware Requirements .....................................................................................13
Table 7. Parts & Kits........................................................................................................................13
Table 8 AirVelocity 1500 Power Supply Options...............................................................................14
Table 9 AirVelocity 1500 Components.............................................................................................14
Table 10. AirVelocity 1500 Physical Dimensions..............................................................................15
Table 11: AirVelocity 1500 Components Weight...............................................................................15
Table 12. AirVelocity 1500 Environment Compliance.......................................................................16

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use iv
Table 13: LED Display..................................................................................................................... 25
Table 14: GPS Kit Contents.............................................................................................................27
Table 15: ABBREVIATIONS & DEFINITIONS..................................................................................31
Document Information
Abstract
This document details procedures for installing the Airspan’s AirVelocity 1500 Indoor-Pico Enterprise
eNodeB variant.
Revision History
Revision Details
Date
Summary of Changes
Rev 0.1
January 2019
Initial document –draft
comments
Rev 0.2 –0.4
March 2019
comments
new mounting variations
Rev A
March 2019
comments
Update EU Directive
Publish
Rev A1
March 2019
Added bracket assembly on the unit

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 2
Warnings and Cautions
Human Exposure to Radio Frequencies
To comply with FCC RF exposure compliance requirements, the device should be located at a distance
of at least 20 cm (7.87 in.)from all persons during normal operation. The antennasused for this product
must not be co-located or operated in conjunction with any other antenna or transmitter.
Radio Interference
This AirVelocity 1500 generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio, television reception, which can be determined by
turning the equipment on and off, the technician is encouraged to try to correct the interference by
performing one or more of the following measures:
Re-orientate or relocate the unit
Increase separation between the units and/or End Devices
Connect the equipment to an outlet on a circuit different from that to which the power source is
connected
Modifications
Any changes and modifications to this device that are not expressly approved by Airspan Networks
may void the user's authority to operate the equipment.
General
Only qualified personnel should be allowed to install, replace, and service the equipment.
The device cannot be sold retail, to the general public or by mail order. It must be sold to
operators.
Installation must be controlled.
Installation must be performed by licensed professionals.
Installation requires special training. The AirVelocity 1500 should be installed ONLY by
experienced installation professionals who are familiar with local building and safety codes
and, wherever applicable, are licensed by the appropriate government regulatory authorities.
Failure to do so may void Airspan's product warranty and may expose the end user or the
service provider to legal and financial liabilities. Airspan and its resellers or distributors are not
liable for injury, damage or violation of regulations associated with the installation of outdoor
units or antennas.
Important Safety Instructions
Read and Save these instructions
This Installation Guide contains instructions and warnings that should be followed during
installation, and operation.
Failure to follow these instructions could cause bodily injury and/or product failure
Safety
1. Read this guide and follow all operating and safety instructions.
2. Keep all product information for future reference.
3. No user serviceable parts inside.
4. Position the power cord to avoid possible damage; do not overload circuits.
5. Do not place this product on or near a direct heat source, and avoid placing objects on
the terminal.

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 3
6. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the
power before cleaning.
7. The units should not be located near power lines or other electrical power circuits.
8. It is the installer’s responsibility to install this device in accordance with the local electrical
codes.
9. Installation of the AirVelocity 1500 must be contracted to a professional installer.
10. Disconnect Device. The socket outlet should be easily accessible in case you have to
disconnect the device.
11. When installed in the final configuration, the product must comply with the applicable
Safety Standards and regulatory requirements of the country in which it is installed. If
necessary, consult with the appropriate regulatory agencies and inspection authorities to
ensure compliance.
Warning of Hazardous Voltages
On AC installations, hazardous voltages exist. Use caution when verifying or working with AC power.
Remove metal jewellery that could come into contact with AC power.
On DC sections, short-circuiting the low voltage, low impedance circuits can cause severe arcing that
may result in burns or eye damage. Remove rings, watches etc. to avoid shorting DC circuits.
Note: Airspan products do not contain hazardous substances (as defined in UK Control of
Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations
1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to
ensure that the product is disposed of in conformance with the relevant regulatory requirements.

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 4
Adherence to European Directive 2014/53/EU
European Council Recommendation 2014/53/EU details basic restrictions and reference levels on
human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these
recommended restrictions and reference levels should provide a high level of protection as regards
the established health effects that may result from exposure to electromagnetic fields.
Warning Symbols
The following symbols may be encountered during installation or troubleshooting. These warning
symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in
working with electrical equipment and radio transmitters. Familiarize yourself with standard safety
practices before continuing.
Caution, hot surface
Caution
Electro-Magnetic
Radiation
DC
Service Information
Refer all repairs to qualified service personnel. Do not modify any part of this device, as this will void
the warranty.
Disconnect the power to this product and return it for service if the following conditions apply:
a. The terminal does not function after following the operating instructions outlined in this
manual.
b. Liquid has been spilled, a foreign object is inside, or the terminal has been exposed to
rain.
c. The product has been dropped or the housing is damaged.
Locate the serial number of the terminal and record this on your registration cardfor future reference.
Also record the MAC address, located on the product sticker.
UL Information
- The electrical source must be properly grounded according with NEC and other local safety code
requirements.
- AirVelocity 1500 is designed to operate in environmental conditions complying with IP40 and
relevant standards.

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 5
DECLARATION OF CONFORMITY
Declaration of Conformity with Regard to the R&TTE Directive 2014/53/EU
Czech:
Airspan tímto prohlašuje, že tento přístroj je ve shodě se základními požadavky a dalšími příslušnými
ustanoveními směrnice 2014/53 / EU.
Danish:
Undertegnede, Airspan erklærer hermed, at følgende udstyrsenhed opfylder de væsentlige krav og
andre relevante krav i direktiv 2014/53 / EF.
Deutsch:
Hiermit erklärt Airspan, dass die Produkteinheit die grundlegenden Anforderungen und anderen
relevanten Bestimmungen der Richtlinie 2014/53 / EU erfüllt.
Estonian:
Käesolevaga kinnitab Airspan, et seadme seade vastab direktiivi 2014/53 / EL olulistele nõuetele ja
muudele kõnealuse direktiivi asjakohastele sätetele.
English:
This equipment is in compliance with the essential requirements and other relevant provisions of
Directive 2014/53/EU.
Español:
Por medio de este Airspan, declara quela unidad cumple con los requisitos esenciales y cualquier otra
disposición aplicable o exigible de la Directiva 2014/53 / UE.
Greek:
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ ΠΡΟΔΙΑΓΡΑΦΗ, η Airspan ΔΗΛΩΝΕΤΑΙ ότι η μονάδα συμμορφώνεται με τις
ουσιώδεις απαιτήσεις και τις λοιπές σχετικές διατάξεις της οδηγίας 2014/53 / ΕE.
Français:
Airspan déclare par la présente que l'appareil est conforme aux exigences essentielles et aux autres
dispositions pertinentes de la directive 2014/53 / UE.
Italiano:
Con la presente Airspan dichiara che questa unità è conforme ai requisiti essenziali e alle altre
disposizioni pertinenti stabilite dalla direttiva 2014/53 / UE.
Latvian:
Ar šo Airspan paziņo, ka vienība atbilst Direktīvas 2014/53 / ES būtiskajām prasībām un citiem
attiecīgajiem noteikumiem;
Lithuanian:
Šis „Airspan“ pareiškia, kad šis įrenginys atitinka esminius Direktyvos 2014/53 / ES reikalavimus ir kitas
nuostatas.
Nederlands:
Airspan verklaart hierbij dat de apparaateenheid voldoet aan de essentiële vereisten en andere
relevante bepalingen van richtlijn 2014/53 / EU.
Maltese:
Hawnhekk, Airspan, tiddikjara li din l-unità tikkonforma mar-rekwiżiti essenzjali u dispożizzjonijiet
rilevanti oħra li jinsabu fid-Direttiva 2014/53 / UE.
Hungarian:
Alulírott, az Airspan kijelenti, hogy az egység megfelel a 2014/53 / EU irányelv vonatkozó alapvető
követelményeinek és egyéb követelményeinek.

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 6
Polish:
Niniejszym Airspan oświadcza, że urządzenie jest zgodne z zasadniczymi wymaganiami i innymi
odpowiednimi postanowieniami dyrektywy 2014/53 / UE.
Português:
Airspan declara que esta unidade está em conformidade com os requisitos essenciais e outras
disposições da Diretiva 2014/53 / UE.
Slovenian:
Airspan izjavlja, da je ta enota skladna z bistvenimi zahtevami in drugimi ustreznimi določbami Direktive
2014/53 / EU.
Slovak:
Airspan týmto vyhlasuje, že tento prístroj spĺňa základné požiadavky a všetky príslušné ustanovenia
Smernice 2014/53 / EÚ.
Suomalainen:
Airspan vakuuttaa täten, että laitteen tyyppi on direktiivin 2014/53 / EU olennaisten vaatimusten ja
muiden asiaankuuluvien säännösten mukainen.
Swedish:
Därmed intygar Airspan att denna enhet överensstämmer med de väsentliga egenskapskraven och
andra relevanta bestämmelser som anges i direktiv 2014/53 / EU.
Íslenska:
Airspan lýsir hér með yfir að þessi eining uppfylli grunnkröfur og aðrar kröfur tilskipunar 2014/53 / ESB.
Norsk:
Airspan erklærer herved at utstyrsenheten oppfyller grunnleggende krav og andre relevante krav i
direktiv 2014/53 / EU.
Român:
Airspan declarăm pe propria răspundere că produsul produsului respectă cerințele esențiale și alte
prevederi aplicabile din Directiva 2014/53 / UE.
The Declaration of Conformity related to this product can be obtained from PLM@Airspan.com.

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 7
Maximum Output TX Total Power
Table 1: AirVelocity 1500 FCC Maximum Output TX Total Power
Frequency Band
(MHz)
FCC
TX (dBm) EIRP (dBm)
Antenna Gain
(dBi)
Variant
3550 - 3700
20.99
29.99
9
1500
Note: The AirVelocity 1500 requires operation using an Airspan FCC-specific version of Netspan
acting as a CBRS Domain Proxy.
Caution: Do not set maximum output TX total power to higher than local regulations.
Product Variants
AirVelocity supports the following frequency bands with the specific performance values:
Table 2: Supported Frequency Bands
Band
Product Code
Downlink
Freq. (MHz)
Uplink
Freq. (MHz)
Duplex
Tx Power per
Channel
(dBm, mW)
48 (42H, 43L)
VNG15-U48-B08P3D
3550 - 3700
3550 - 3700
TDD
20.99dBm
Power Consumption
AirVelocity 1500 has a maximum nominal power consumption of 30W. AirVelocity 1500 power
consumption is described in the following table:
Table 3: Power Consumption
Duplex
LTE Tx Power Before
the Antenna (dBm)
Nominal Power
Consumption (W)
TDD
25
≤30
Note:
Nominal Power Consumption (W) - refers to average power consumption over time.
Power Supply Requirement (W) - refers to the required power supply rating connected to
the eNodeB

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 8
LTE Antenna System
The following antenna is designed specifically for AirVelocity 1500 deployments; specifications are
described in this section.
Integral Sectorial Antenna
The integral sectorial antenna is a cross-polarized fixed antenna which is an inseparable part of the
unit. Use of an external antenna is not part of the product design.
LTE Antennas
AirVelocity 1500 has a sectorial antenna that behaves as an Omni antenna for ceiling mount and
Directional antenna for wall mounting.
Note: The integral LTE antenna included is dependent on the product’s LTE band.
Table 4: Integral Sector Antenna Parameters (LTE)
Frequency [GHz]
Boresight gain
(typical)
Mounting
location
Horizontal 3dB
BW (typical)
Vertical 3dB BW
(typical)
3.55 –3.7
8 dBi
Wall
65
65
Ceiling
Omni
30

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 9
About This Document
Purpose
This guide provides the workflow and step-by-step procedures for installing the Airspan’s AirVelocity
1500, Enterprise-Pico eNodeB variant. These procedures include:
Verify prerequisites
Install Mounting bracket (Ceiling or Wall)
Install the AirVelocity 1500
Install GPS Antenna (if required)
Connect and manage cables
Intended Audience
This guide is intended for persons who are responsible for installing the AirVelocity 1500 equipment.
These persons should have aworking knowledge of LTE.
Document Conventions
This document uses the following typographic conventions.
Table 5: Typographic Conventions
Convention
Element
Blue underlined text
Cross-reference links.
Bold text
Keyboard buttons and GUI elements.
Command
Command names or phrases.
Computer output
Text displayed by the computer.
Hyperlinks
Website and e-mail addresses.
Danger
Signifies a hazardous situation—if not avoided—will
cause death or serious injury. Describes how to avoid
it.
Warning
Signifies a hazardous situation—if not avoided—can
cause death or serious personal injury. Describes
how to avoid it.
Caution
Signifies a hazardous situation—if not avoided—can
void the product warranty, and cause property
damage. Describes how to avoid it.
Important
Provides necessary information to explain a task.
Note
Provides additional information.
Tip
Provides helpful hints.
Related Reading
The following documents contain related information:
AirVelocity 1500 Hardware Product Specification
Airspan LTE Commissioning Manual

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 10
Customer Care Help Desk
Airspan’s Customer Care Help Desk offers prompt and efficient customer support services.
Note: To avail Airspan’s Customer Care Help Desk support, youmust be a registered user and must
have a valid support contract. To register, click here and fill the Registration form.
To create and update issue logs, send e-mails to Customer Care Help Desk. Once you submit your
issue, the system generates a new issue and sends an issue number for your reference. The system
uses this issue number to categorize and store e-mails under the appropriate issue.
To help Customer Care Help Desk identify your issue, include the issue number and your Customer
Care Helpdesk account details in all further communications.
Main Operations
Airspan Communications Ltd.
Capital Point
33 Bath Road
Slough, Berkshire
SL1 3UF, United Kingdom
Tel: +44-1895-467-100
Worldwide Headquarters
Airspan Networks Inc.
777, Yamato Road, Suite 105
Boca Raton, FL 3341-4408, USA
Tel: +1 561 893 8670
Airspan Encourages Comments
Airspan welcomes any feedback and suggestions that help to improve the quality of the documentation.
Send your feedback to documentfeedback@airspan.com.

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 11
1 Introduction
This section provides a descriptive overview of the Airspan’s AirVelocity 1500 Enterprise-Pico
eNodeB and its place in the product suite.
1.1AirVelocity 1500
AirVelocity 1500 is part of Airspan’s carrier-class 4G Pico eNodeB family. AirVelocity 1500 supports
3GPP’s Long Term Evolution (LTE) eNodeB, providing high-speed data and mobility, in order to meet
the demands of the Broadband Wireless Access market.
AirVelocity 1500 is a super-compact, easy to install indoor pico-cell, allowing an operator to deploy
LTE broadband services in Public Venues, as well as Enterprise Offices, supporting both wall and
ceiling mounting.
AirVelocity 1500 is a high performance indoor pico eNB supporting a single sector non-contiguous
dual carrier solution that can support up to a total of 40MHz bandwidth.
AirVelocity 1500 employs Software Defined Radio (SDR) technology, together with two transmit
paths, two receive paths, antennas and clock synchronization –all in a highly integrated, physically
small and light, targeted to blend seamlessly into the environment. This super compact pico product
minimizes physical footprint, power consumption and operator OPEX.
AirVelocity 1500 LTE radio implements a quad 25 dBm (4 x 315mW) transmit channels, with an
integral antenna.
Note: For management please refer to the Airspan LTE Commissioning Manual as well as the
Netspan User Manual.
Note: The AirVelocity 1500 requires operation using an Airspan FCC-specific version of Netspan
acting as a CBRS Domain Proxy.
Figure 1: AirVelocity 1500

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 13
3 Verifying Prerequisites
Prior to installing the AirVelocity 1500, verify the required safety, power, tools, parts and components.
This chapter includes the hardware, software, and client requirements for installation.
Important: Set up requirements for the installation is detailed in the Job Sheet, see Appendix A.
3.1Verifying Site Requirements
To set up the AirVelocity 1500, an IP connection to a Netspan server is required.
3.2Verify Installation Requirements
3.2.1Verify the Tools
Table 6. Minimum Hardware Requirements
Tool
Use
Phillips head screwdriver
Attach wall / ceiling mounting bracket
Spanner (wrench) M5
Tightening locking nuts when mounting
3.2.2 Verify the Parts and Kits
Note: Verify order and requirements to ensure the correct unit type is being installed.
Table 7. Parts & Kits
Installation Kit /
Part
Part No.
Airspan No.
Consisting of:
Note:
AirVelocity 1500,
3.55 –3.70 GHz
VNG15-U48-
B08P3D
998-13-481,
998-13-481MS
AirVelocity 1500 BTS,
3.55GHz (B48), Ethernet
copper backhaul, POE++ / DC
input, including –P/N 402-00-
813 - brackets –Qty.x2
Frequency band
and assembly type-
specific
AirVelocity 1500
Ceiling/Suspended
Ceiling Mounting
Kit
VNG15-SCMK-1
903-03-481
1x suspended ceiling/ceiling
mounting plate
4x suspended ceiling rail
plate(2)
1x Speed Link SLK with Y-
Hook configuration with 2 mm
Wire Rope Diameter Wire
Rope Length=3.3'
Necessary Hardware
One per unit
Sold Separately
AirVelocity
Mounting Kit
VNG15-CMK-1
903-03-482
1x suspended ceiling/ceiling
mounting plate
1x Locking pin with key ring
6.5x15mm
One per unit
Sold Separately

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 14
Note: Either suspended ceiling mounting kit or standard ceiling mounting kit is required, depending
on field conditions. Suspended ceiling mounting kit includes the standard ceiling mounting option.
3.2.3 Power Supply
AirVelocity 1500 supports direct connection to DC power source or to POE++ power source:
RJ45 POE++ Operational Voltage Range: 50.0–57.0 Vdc, IEEE802.3bt class 6
DC port Operational Voltage Range: 9-14Vdc
AC to POE++ injector or AC to DC power supply are not included with the AirVelocity 1500 and can be
ordered separately.
Table 8 AirVelocity 1500 Power Supply Options
Installation Kit / Part
Part No.
Airspan No.
Note
POE++ PSU,60W,IN 100-240VAC,OUT
56VDC/1.2A & US AC Cable
VNG-PSU-US-ID-POE++1
903-03-110
One per unit
AC ADAPTER,60W, IN 100-240VAC,OUT
12VDC/5A & US AC Cable
VNG-PSU-US-ID-AC-1
903-03-111
One per unit
Note: Unit variant determines the PSU type required.
3.2.4 Verify Components
The following figures display various AirVelocity 1500 components and accessory kits.
Table 9 AirVelocity 1500 Components
Parts
Images
AirVelocity 1500 Unit
+ x 2
Suspended Ceiling/Ceiling
mounting plate + hardware
+ X4
Locking Pin
Security cable (suspended ceiling
mounting)
AC to POE++ power supply
AC to DC power Supply

AirVelocity 1500 Installation Guide
DUG01560 Airspan Commercial and Internal Use 15
AirVelocity 1500 is shown below displaying the Copper Ethernet ports and the GPS connection panel.
Figure 2: AirVelocity 1500 Ports (DC Variant)
3.2.5 Physical Dimensions
3.2.5.1Dimensions
AirVelocity 1500 is an indoor enclosure. Below are the AirVelocity and related parts dimensions (H x W
x D):
Table 10. AirVelocity 1500 Physical Dimensions
Part
Dimensions (H x W x D)
AirVelocity 1500
250 x 250 x 60 mm / 9.84 x 9.84 x 2.36 in.
Mounting plate for unit (ceiling)
160 x 163.1 mm x13.50 Height
Rail plate (ceiling)
52.9 x 52.9 mm x 18 mm (plate + pins)
Rail Bracket (ceiling & wall) –comes
assembled on the AV 1500 unit
64 x 55.50 mm x 17.50 Height
3.2.5.2Weight
The weight of all AirVelocity components are listed below:
Table 11: AirVelocity 1500 Components Weight
Component
Weight
Main unit
3 kg (6.6 lb)
Mounting plate for unit (ceiling)
263 g (9.28 oz.)
Rail plate (ceiling)
26 g (0.917 oz.) x 4 = 104 g (3.67 oz.)
Rail Bracket (wall & ceiling)
47 g (1.66 oz.) x 2 = 94 g (3.32 oz.)
Locking pin
7 g (0.25 oz.)
Table of contents
Other Airspan Wireless Access Point manuals

Airspan
Airspan AS3010 Manual

Airspan
Airspan Mimosa A5x User manual

Airspan
Airspan ProST 4.9 Manual

Airspan
Airspan ASWipLL User manual

Airspan
Airspan AS4000 Installation guide

Airspan
Airspan EasyST Manual

Airspan
Airspan AIRSTRAND 2200 User manual

Airspan
Airspan AirSpeed 2900 User manual

Airspan
Airspan ProST Manual
Popular Wireless Access Point manuals by other brands

ConnectGear
ConnectGear WA620G manual

Linksys
Linksys LAPN600 user guide

Extreme Networks
Extreme Networks ExtremeWireless AP560h installation guide

Firetide
Firetide HotPort 6100 Series Hardware installation guide

TRENDnet
TRENDnet N300 TEW-739APBO Quick installation guide

Digisol
Digisol DG-WM6305SIE2 user manual