1
Interface Display
Parts and Functions

2
ON/OFF
Adjusting key for temperature, clock, timer, sleeping
adjustment, temp. compensation and energy saving;
Inquiring key for detail parameter and malfunction inquiry;
Switching key for function switch.
The adjusting accuracy of temperature is 0.5°C (1°F). If energy
saving mode is not set, the adjusting range is from 16°C
(60°F) to 30°C (86°F). If energy saving mode is set, the lowest
temperature limit of cooling/dry and the highest temperature
limit of heating are decided by the setting of the chip, the
default cooling/dry temperature is 23°C (74°F), and the default
heating temperature is 26°C (78°F).
Note:
• If the dip switch Sw2 is “on”, it displays the ambient temp., as
well as when powered off. From power off to power on, mode
switching and set temp. adjustment, it ashes to display SET
icon and statically displays the set temp.. And then statically
displays the ambient temp. and ROOM icon after 3 seconds.
In energy saving mode and temp. compensation mode, the
adjusting step is 1°C (1°F) a time.
Key
Parts and Functions

3
• If using Fresh Air unit, set temp. cannot be adjusted. If there
is no Central/Lock set, the temp. will be xed at 18°C (64°F)
in cooling and 22°C (72°F) in heating. The Up/Down key will
not display in normal state, but will display and valid in timer
setting, function selection, unit shift in malfunction inquiry,
parameter shift in parameter check, unit No. setting, sleeping
time adjustment, etc.
24-hour, press once to minus one minute. Keep pressing,
minus 2 minutes in 1 second’s pressing, then 10 minutes
in 5 seconds. The time will keep decreasing at the pace of
10 minutes a time in 10 seconds. Vice-versa. Press to
conrm or it will turn back to the previous state automatically in
10s.
Parts and Functions
Press this key to execute mode switch. For detailed
information, please refer to mode setting.
Note: If using Fresh Air unit, default 3 modes will circulate from
cooling→heating→fan→cooling.

4
Pressing this key, fan speed will be changed in sequence as
follows: (Low) → (Medium)
→ (High)→
(Auto) → (Low)
Note: Auto fan will be changed in sequence as follows:
→ →
→
Pressing this key, fan speed will be changed in sequence as
follows (Only valid for parts of models):
(Breeze) → (Low) →
(Medium) →
(High) → (Super) →
(Auto) → (Breeze)
Auto fan circulation:
(Breeze) → (Low) →
(Medium) →
(High) → (Super)
There is no auto fan in fan mode; The fan icon will ash when
adjusting the fan speed. It will statically display after the
adjustment.
Parts and Functions

5
Timer ON, Timer OFF, Timer ON/OFF.
Press this key to enter function circulation. If it is the four-
way cassette model, press Set key for 5s to enter function
circulation.
1.Press to select the functions in sequence as follows:
(Only when Left/Right swing is valid) → (Only when Up/
Down swing is valid) → → (ventilation function) →
(reserved function) → (When it’s time for lter cleaning,
this icon will involve in circulation) → (the second 8 of
88.8 in the temp. display area displaying A,only valid for part
of models)→ (the second 8 of 88.8 in the temp. display
area displaying B,only valid for part of models)→ (motion
sensing,only valid for part of models) →10°C heating function
(this function only works in the heating mode, only valid for
part of models) → health airow up (Only valid for part of
models) → health airow down (Only valid for part of models)
Parts and Functions
Note: If using Fresh Air unit, fan will be in auto fan and cannot
be adjusted. If press FAN key, fan icon and FFFF on the
top-right corner will ash, prompting fan speed cannot be
adjusted, and will statically display after 3s. Fresh Air unit fan
speed will be controlled automatically by indoor unit and wired
controller will always display auto fan.

6
2.Press to select the functions in sequence as follows:
health airow down (Only valid for part of models) → health
airow up (Only valid for part of models) →10°C heating
function (this function only works in the heating mode, only
valid for part of models) → (motion sensing,only valid
for part of models) → (the second 8 of 88.8 in the temp.
display area displaying B,only valid for part of models) →
(the second 8 of 88.8 in the temp. display area displaying
A,only valid for part of models) → (When it’s time for lter
cleaning, this icon will involve in circulation) → (reserved
function) → (ventilation function) → → (Only when
Up/Down swing is valid) → (Only when Left/Right swing is
valid)
3. Press to conrm function selected. If there is function
selected, press can cancel this function.
Note: The Left/Right swing is valid only after the dip switch
is set, the lter icon is shown only after the lter requires
cleaning.
Parts and Functions

7
Parts and Functions
Icon
Clock; Parameter setting/inquiry; Malfunction
display; Mode setting.
Timer ON/OFF: Sleeping; Parameter setting/
inquiry; Malfunction display.
ROOM/SET temp. and humidity display, each
step is 0.5°C (1°F) . For example, if the temp.
is 25°C (77°F), it will display 25.0°C (77°F).
Humidity display function is reserved.
Energy Saving, This icon will be displayed
only when energy saving function is set.
Filter Cleaning.
Child Lock. This icon will be displayed only
when child lock function is set.
/ Lock/ Central
Motion Sensing (Only valid for part of
models).
Left/Right Swing. This icon is displayed in
swing mode; no display without swing mode.
Up/Down Swing. This icon is displayed in
swing mode; no display without swing mode.

8
Parts and Functions
Sleeping. This icon is displayed when setting the
sleeping, and left time of sleeping is displayed by
Heat Reclaim Ventilation, This icon is displayed when
setting the heat reclaim ventilation.
Electrical Heating. This icon will display when electrical
heating is set on DC wired controller.
Intelligent Mode.
Cooling Mode. Heating Mode.
Fan Mode. Dry Mode.
Breeze Fan Speed (Only
valid for part of models)
Low Fan Speed.
Medium Fan Speed.
High Fan Speed.
Super Fan Speed (Only
valid for part of models)
If the fan speed is set in auto fan, it will change in the
following sequence: Breeze(Only valid for part of models)
→Low→Medium→High→Super (Only valid for part of
models), AUTO icon will display simultaneously.

9
Dip Switch Interpretation (for AC)
Operation
DIP
switch
On/Off
station Function Default
setting
Sw1 On Slave wired controller Off
Off Master wired controller
Sw2 On Ambient temp. display on Off
Off Ambient temp. display off
Sw3
On Collect ambient temp. from PCB of
indoor Off
Off Collect ambient Temp. from wired
controller
Sw4 On Non-volatile memory invalid Off
Off Non-volatile memory valid
Sw5 On Old protocol Off
Off Selfadaption
Sw6 On reserved Off
Off reserved
Sw7 On Model with Up/Down and Left/Right
swing Off
Off Model with Up/Down swing
Sw8 On Fresh Air unit Off
Off General unit

10
(1)The wired controller will display all the icons after powering
on or reset, then get into the initializing process. The controller
will display in sequence as follows: (the top-left
corner) → (the top-right corner) → → (the
top-left corner), the green LED ashes all the time until the
initialization ends.
Initialization
Operation
Difference between the Function of the Master Wired
Controller and Slave Wired Controller
Comparison
item
Master
wired
controller
Slave wired controller
Function
All
functions
are
available
1. ON/OFF, Mode, Fan Speed, Temp.
Setting, Swing, Energy Saving, Clock
function, Heat Reclaim Ventilation
function, Mode Setting, Screen
Saving and Child Lock are available
2.Cancel the lter cleaning icon
3.Look up the detailed parameter and
malfunction code

11
Operation
(1) In the state of off and non screen saving, keep pressing
and for 5s to set screen saving time, which will be
shown after the top-right colon 88 statically. Press Up/Down
key to adjust screen saving time and press key to conrm.
(2) Screen saving time should be 0s(backlight always on),
15s, 30s, 60s, default value is 15s. If it is not the rst time of
entering, it will display the screen saving time adjusted last
time.
(3) In the process of changing screen saving time, press ON/
OFF key to quit screen saving time setting function, it will
recover to screen saving time before adjustment and start-up
the unit.
Note:
When controlling Fresh Air unit, the controller main interface
will not display Up/Down key in normal state. When in screen
saving setting, press Time key rst to display Up/Down key at
the main interface, and then press together Time and Down
key to enter screen saving time setting.
Screen Saving
(2) If the wired controller can’t be communicated with the
indoor PCB normally after powering on, the initialization will be
nished in 4 minutes, and then the communication malfunction
can be checked from the malfunction inquiry function.

12
Operation
(1) 24-hour system is used, and at rst time of powering on, it
will display default 12:00.
(2) When rst powering on wired controller, will be
displayed on the wired controller interface, clock time can
be adjusted within 10s. At the same time, clock icon and
minute-place of time will ash, meaning the current time can
be adjusted. Press Up/Down key to adjust minute-place with
ashing of clock icon and no ashing of minute-place. Press
Time key to shift to hour-place, and then press Up/Down key
to adjust hour-place with ashing of clock icon and no ashing
of hour-place. After adjustment, clock icon and hour-place will
ash and press key to conrm and clock icon and time
will display statically.
Clock Function

13
Operation
(3) Press Time key for 5s to enter clock setting function. It
will show after rst powering on (if not rst time of
powering on, clock time is the memorized time), with clock
icon and minute-place ashing, meaning current time can be
adjusted. Press Up/Down key to adjust
minute-place with ashing of clock icon and no ashing of
minute-place. Press Time key to shift to hour-place, and then
press Up/Down key to adjust hour-place with ashing of clock
icon and no ashing of hour-place. After adjustment,
clock icon and hour-place will ash and press key to
conrm and clock icon and time will display statically.
(4) Clock time adjustment: when adjusting time, press one
time to reduce one minute/hour while press one time to add
one minute/hour. Keep pressing or key to accelerate time
adjustment, with 2 times/s change after 1 s, 10 times/s change
after 5s. After 10s, it will change by 10 minutes and frequency
is 10 times/s.
(5) In the process of time adjustment, if there is no operation
for 10s, it will quit and restore previous state.
(6) In the process of time adjustment, press ON/OFF key to
quit clock setting function and execute turning on/off operation
at the same time.

14
Operation
(7) When setting timer or sleeping function, clock time cannot
be adjusted. If press Time key for 5s to enter clock adjustment,
clock icon and clock time will ash indicating time cannot be
adjusted.
(1) Timer mode setting: Timer ON, Timer OFF, Timer ON/OFF.
(2) Default: Timer ON is , Timer OFF is .
(3) Precision: The time precision is 1 minute. Timer clock is
based on the current clock time; the adjustment is the same as
clock time.
(4) Press timer key, the timer function circulation is as follows:
, ON and the Hour position are ashing→
, ON and the Minute position are ashing→
, OFF and the Hour position are ashing→
, OFF and the Minute position are ashing→
, ON and the Hour position are ashing→
, ON and the Minute position are ashing→
, OFF and the Hour position are ashing→
, OFF and the Minute position are ashing→the
timer icon will disappear.
Timer Function

15
Operation
① the hour or minute position is ashing, press to adjust
the timer, Keep pressing to accelerate the adjusting speed,
then to conrm the setting.
②The controller will judge the order of timer on and off and
use the arrow to show the order. First ON then OFF:ON→OFF,
First OFF then ON:ON ←OFF.
③The ON/OFF button has no affection on timer setting. Under
power off state, the Timer key is valid.
(1) If there is no Time key related operation for 10s, this setting
will be cancelled and the timer will come back to the previous
state.
(2) Press Time key, until the timer icon disappear,the time
function will cancel.
(3) Relation to other buttons when timer is set.
Press the key or key to exit the current setting,
press them again to operate the function accordingly; Press
the (ON/OFF) key can exit the timer setting and power
ON/OFF directly. If there is a timer before, the wired controller
will operate by following the previous setting. If not, the wired
controller will have no timer operation.
Timer Setting Cancellation

16
Operation
(1) If Sw5 is on, only the Up/Down swing will be involved in
function circulation. At this time SW7 is invalid.
(2) If Sw5 is off, swing type can be set by Sw7, when Sw7 is
off, only Up/Down swing valid, when Sw7 turns on, Up/Down
and Left/ Right swing valid. Only Up/Down swing is default.
① If Sw7 is off (default): only Up/Down swing is available.
Press SET key to enter function circulation, Up/Down swing
icon ashing, then press SET key again to conrm with swing
icon statically displaying. If swing function is set, execute the
above operation to cancel.
②If Sw7 is on: Up/Down swing and Left/Right swing are
available.
Press SET key to enter function circulation, Left/Right swing
icon ashing, then press Up/Down key to enter Up/Down
swing, with Up/Down swing icon ashing. Press SET key again
when swing icon ashing to conrm, with swing icon statically
display. If swing function is set, execute the above operation to
cancel.
③If connecting to the salve wired controller, Sw7 dip code of
master and slave wired controllers should be set the same and
should match the actual wired controller unit.
Swing

17
Operation
(3) If Sw5 is off, some models can self-adaptive the swing
setting and swing angle control.
①If the angle of the Up/Down swing can be adjusted:
Press SET key to enter the function circulation; the Up/Down
swing icon will ash. Press the SET key again; the swing
angle will ash(if powered on for the rst time, default angle
will be different according to different modes; if not for the rst
time, the angle of swing will be displayed as last time). At this
time, swing angle can be adjusted by Up/Down key (when in
intelligent mode, the swing angle is position 1,press up key
to automatic swing, and press down key to position 2).When
pressing Up/Down key to adjust angle, If no operation in 10s,
it will exist angle adjustment and function circulation. Interface
displays the last angle. If you want to set other functions like
sleep function, you need to press SET key again to enter
function circulation.

18
Operation
②If the angle of the Up/Down and Left/Right swing can be
adjusted:
Press SET key to enter the function circulation, and the Left/
Right swing icon will ash. At this time, press Up/Down key to
switch to Up/Down swing icon ashing. When Left/Right swing
icon ashing, Press SET key again, the angle of Left/Right
swing will ash(if powered on for the rst time, the default
angle is in position 1, the middle position of Left/Right swing
icon; if not for the rst time, the angle will be displayed as last
time).
(4) Pressing Fan key or Mode key can both exit swing function,
with no order sending. When Fan or Mode key is pressed
again, the order will be sent. If the present angle is conrmed,
pressing SET key will exit the swing function. In the adjustment
process, if there is no key pressed for 10s, swing function
will be exited, and swing angle will execute the nal adjusted
angle. In the adjustment process, pressing the ON/OFF key to
power off the wired controller directly, and swing angle is the
nal adjusted swing angle.

19
Operation
Health airow up/down function (Only valid for part of
models)
(1) The function can be set through wired controller or remote
controller.
(2) The function circulation is as follows:
(Only when Left/Right swing is valid) → (Only when Up/
Down swing is valid)→ → (ventilation function)→
(reserved function)→ (When it’s time for lter cleaning,
this icon will involve in circulation) → (the second 8 of
88.8 in the temp. display area displaying A,only valid for
part of models)→ (the second 8 of 88.8 in the temp.
display area displaying B,only valid for part of models)→
(motion sensing,only valid for part of models) →10°C heating
function(this function only works in the heating mode, only
valid for part of models) → health airow up (Only valid for
part of models) → health airow down (Only valid for part of
models)
(3) The function is valid only when the angle of Up/Down swing
can be set.
(4) Health airow up/down function cannot be set at the same
time. When the latter is set, the former will be automatically
canceled.
(5) This function is ground oor setting, no matter on/off,
memory remained.
Table of contents
Other Airwell Remote Control manuals

Airwell
Airwell RC18 User manual

Airwell
Airwell RC5 User manual

Airwell
Airwell RC 08B User manual

Airwell
Airwell RC08C User manual

Airwell
Airwell RC5 User manual

Airwell
Airwell RC7 User manual

Airwell
Airwell RC4 User manual

Airwell
Airwell RCV03 User manual

Airwell
Airwell RCW25 User manual

Airwell
Airwell RC08A User manual
Popular Remote Control manuals by other brands

Elmes Electronic
Elmes Electronic U1HS manual

Reely
Reely GT2+1 EVO operating instructions

Samsung
Samsung MIM-E03*N installation manual

Bellman & Symfon
Bellman & Symfon BE2021 Maxi Pro Medical device information

Ltech
Ltech F1 manual

Universal Remote Control
Universal Remote Control PHAZR-5 operating instructions