Installer- please read all instructions carefully before installation
and leave these instructions with the end user for future reference
PW90 & ONYX PW90 15 & 22mm Shower
Waste Installation Instructions
ONYX PW90- 22mm
PW90- 15mm
PW90- 22mm
Technical Help line 01905 560219 www.akw-ltd.co.uk
Installation Instructions
Supp
o
rt
t
Noggins
t
1
(1) As a “dry run”, first place
the tray into the desired
location either into wooden
or solid floors. Determine the
position, the depth and the
clearance required for the
waste with at least a 1 in 40
fall from the waste to the
outlet pipe. Ensure there is
sufficient support around the
waste area, see separate tray
instructions.
(2) Insert the 15/22mm
waste outlet pipe into the
waste body and insert the
“C” clip to seal the outlet
pipe. Check the pipe
connection is correctly sealed
and watertight by pouring
some water through it.
Ensure that the rubber
clamping ring seal (A) is
positioned into the recessed
section on the top of the
waste body before connecting
to the tray.
(3-4) Apply flexible adhesive to
the tray and ensure that the
tray is level.
Lower the tray into position
either into or onto wooden or
concrete floors and then re-
align with the waste body.
(5-6) Ensure that the
clamping ring (B) is screwed
correctly to the waste body.
Do not over tighten but
ensure a tight seal.
(7) Lower the waste trap body
into waste main body and
ensure a tight seal is achieved.
(8) Fit the cover ensuring the
location pegs are inserted fully
home into the cover.
48
7
6
B
5
A
3
2
Keeping your wastes
clean
This product should be
cleaned periodically to
remove any accumulation
of hair or other waste
material, using normal
domestic bathroom
cleaning materials.
First remove the cover.
Then lift out the trap body.
Wash with warm soapy
water taking care not to
damage the rubber seal.
Always face the dry trap
arrow pointing towards
the waste outlet pipe after
cleaning.
Disinfecting
Where disinfecting is
necessary, standard
procedures for disinfecting
equipment should be used,
taking due care and
attention to the warning
signs concerning possible
effects of aggressive
chemicals on plastics.
After cleaning, always
flush down with water
then wipe thoroughly with
a damp cloth to remove
any cleaning material
residues before drying.
Do not use strong or concentrated acidic, alkaline or other cleaning materials as these may discolour or otherwise
damage the product. Do not use abrasive cloths. AKW does not approve or recommend autoclave cleaning of
any of the components due to the damage which this can cause to the special engineering plastics used in the
construction of this product.
Packaging
Wastes are supplied in a polypropylene (PP) bag to keep the product unsoiled until installation; it may also be
packed in a cardboard box. Both are suitable for recycling operations and should be disposed of in accordance
with local recycling regulations.
User Care Instructions
AKW wastes are designed for low maintenance and reliable operation. The water trap is located inside the waste
body and should be checked as part of a planned maintenance programme. Any part showing evidence of damage
or misuse must be replaced.
Clamping
Ring (B)
Outlet Pipe
15/22mm
Waste Main Body
15/22mm
“C” Clip
Waste Trap
Body
Clamping
Ring Seal (A)
ONYX PW90
22mm
04-003-009-05 UK
© 2018 AKW
These instructions are provided to advise the minimum standards of installation and recommends what the best practice for the installation is.
Due to the very wide variability of possible installation conditions, AKW cannot provide all circumstances for the installation. AKW cannot accept any
liability in connection with this information or its use. This information is provided on the condition that the person receiving it shall make his/her
own tests to determine the suitability for the particular purpose. Failure to install this AKW product in accordance with supplied instructions or the
making of unauthorised modifications will invalidate any warranty and may affect product safety. None of the foregoing affects your statutory rights.
STOP
STOP
STOP
Technical Help line
01905 560219
Orderline
01905 823299
General Enquiries
01905 823298
Fax
01905 823297
Website
www.akw-ltd.co.uk
Quotes & orders email
[email protected]
Enquiries email
[email protected]
[email protected]
Post
AKW, Pointon Way,
Hampton Lovett,
Droitwich Spa,
WR9 0LR
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
For the latest AKW product news
scan this QR code with your device.
ALWAYS read these installation instructions
carefully before installing this
product and leave with the end user
for future reference.
ALWAYS have the waste installed by an
experienced installer.
ALWAYS match the correct waste to the
shower tray.
ALWAYS test the waste outlet and seals for
water tightness before installing the
tray as this will be difficult once the
shower tray is installed.
NEVER use the waste without the unit fully
assembled and the clamping ring seal
in place.
Caution always check for electric cables and
water pipework before cutting into
floor boards or drilling into surfaces.
Beware a pinch hazard may be present around
the edges during installation.
What to do if something goes wrong?
In the event that you should encounter
a problem with this product,
please contact your local installer and
if this does not resolve the issue, then
contact AKW technical team who will
provide further advice and, if necessary,
arrange for a maintenance engineer
to visit and report any issues.
As part of our quality and training
program, calls may be monitored or
recorded. None of the foregoing affects
your statutory rights.
The guarantee applies only to manufacturing or material
defects conditional on the correct installation of the
product and does not apply to blockages, inappropriate
use or accidental damage. This does not cover damage
or defects that result from incorrect installation, lack
of maintenance including the build up of grime, dirt or
lime-scale and water-borne debris. Damage resulting
from inappropriate cleaning or water ingress, damage
or defects that result from repairs or modifications
undertaken by persons who are not installer or
maintenance engineers.
Important Safety Information
Guarantee

This manual suits for next models

1

Other Akw Plumbing Product manuals

Akw AKW23196CH Quick start guide

Akw

Akw AKW23196CH Quick start guide

Akw Option P User manual

Akw

Akw Option P User manual

Akw Luda User manual

Akw

Akw Luda User manual

Akw Braddan 16472W Installation guide

Akw

Akw Braddan 16472W Installation guide

Akw Stone Wash Basin Service manual

Akw

Akw Stone Wash Basin Service manual

Akw Onyx Toilet Roll Holder User manual

Akw

Akw Onyx Toilet Roll Holder User manual

Akw Itherm Quick guide

Akw

Akw Itherm Quick guide

Akw iSure Quick guide

Akw

Akw iSure Quick guide

Akw Onyx Linea AKW23980WH User manual

Akw

Akw Onyx Linea AKW23980WH User manual

Akw SMV-001 Guide

Akw

Akw SMV-001 Guide

Akw Larenco User manual

Akw

Akw Larenco User manual

Akw Arka Thermostatic Cool Touch TMV2 User manual

Akw

Akw Arka Thermostatic Cool Touch TMV2 User manual

Akw T301 User guide

Akw

Akw T301 User guide

Akw Onyx Installation guide

Akw

Akw Onyx Installation guide

Akw M DigiPumps Series User manual

Akw

Akw M DigiPumps Series User manual

Akw GW90 User manual

Akw

Akw GW90 User manual

Akw MediCare Installation guide

Akw

Akw MediCare Installation guide

Akw iTherm 30306 User manual

Akw

Akw iTherm 30306 User manual

Popular Plumbing Product manuals by other brands

Bradley Express SS-2N/AST/STD Installation

Bradley

Bradley Express SS-2N/AST/STD Installation

Brizo VENUTO manual

Brizo

Brizo VENUTO manual

Sanela SLUN 54 Mounting instructions

Sanela

Sanela SLUN 54 Mounting instructions

Moen BGCW10RV1618 installation guide

Moen

Moen BGCW10RV1618 installation guide

Luxart AERRO A711FMTO installation manual

Luxart

Luxart AERRO A711FMTO installation manual

Signature Hardware MEDFORD 946810 manual

Signature Hardware

Signature Hardware MEDFORD 946810 manual

Kohler K-8816 installation guide

Kohler

Kohler K-8816 installation guide

Kohler K-6448 Homeowner's guide

Kohler

Kohler K-6448 Homeowner's guide

Zanussi 132455 Specifications

Zanussi

Zanussi 132455 Specifications

Gerber C0-44-551 Installation

Gerber

Gerber C0-44-551 Installation

Laufen ILBAGNOALESSI One 8.1197.1 installation instructions

Laufen

Laufen ILBAGNOALESSI One 8.1197.1 installation instructions

Grohe GROHTHERM 2000 34 174 instructions

Grohe

Grohe GROHTHERM 2000 34 174 instructions

T&S B-0315-LN Installation and maintenance instructions

T&S

T&S B-0315-LN Installation and maintenance instructions

Gessi VIA MANZONI 38731 manual

Gessi

Gessi VIA MANZONI 38731 manual

SUMS uridan ADMIRAL GH-10 installation instructions

SUMS

SUMS uridan ADMIRAL GH-10 installation instructions

VIGO VG08004 manual

VIGO

VIGO VG08004 manual

Kohler BADRON K-5487T-B installation instructions

Kohler

Kohler BADRON K-5487T-B installation instructions

BATHSELECT BST-008-1ORB installation instructions

BATHSELECT

BATHSELECT BST-008-1ORB installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.