Installation Instructions
WARNING: To prevent electrical shock, disconnect from power source before installing or servicing.
IMPORTANT: 800T devices should be mounted in and properly bonded to, a grounded metal enclosure. When installing the device in a metal enclosure, maintain 1/2” (12.7) minimum clearance between exposed
metal parts of contact block and enclosure.
800T devices are rated Type 4 and 13, 800H devices are rated Type 4, 4X and 13. Install on a at, smooth surface of an enclosure. Devices maintain their Type ratings only when properly mounted in an enclosure with
the same rating(s).
Emergency Stop Push Buttons are UL NISD Listed when mounted in a non-ventilated enclosure only.
Bulletin 800T / 800H Pilot Devices
(Cat 800T; 800H)
WARNING: For those illuminated and pilot devices rated for Class 1 Division 2 Hazardous Locations, EXPLOSION HAZARD - Do not replace bulb unless power has been switched o
or the area is known to be non-hazardous.
For those illuminated and pilot light devices rated for Class 1 Division 2 Hazardous Locations, the lens must be assembled to the device. Those devices rated Class 1 Division 2 are marked specically as such
on the device.
Lens or cap must be tight against bushing to provide a tight seal.
Installation (see Figs. 1 and 2)
1. Remove the following parts from the unit:
Lens or cap, mounting ring, thrust washer and legend plate or trim washer.
2. Determine the correct number of gaskets to be used per the table in Fig. 1.
3. Place the unit into the mounting hole from the rear of the panel.
4. Position legend plate or trim washer and then thrust washer, with thrust washer tang engaging legend plate or trim washer and panel notches.
5. Install mounting ring and tighten against thrust washer to 25 - 30 lb-in (2.8 - 3.4 Nm).
6. Install lens or cap to operator.
Lamp Replacement: (Bayonet Base)
1. Remove Lens
2. To remove lamp: Push lamp inward, turn counterclockwise, and remove
3. To install new lamp: Insert in socket, push inward and turn clockwise (see Figure 3)
4. Reinstall Lens
Available Mounting Accessories:
Wrench for Octagonal Mounting Ring - Catalog No. 800T-N245
Wrench for 800H Pilot Light Mounting Ring - Catalog No. 800H-N10
Device Bonding Kit for 800T devices to meet the bonding requirements of CSA Standard C22.2 No. 0.4 - Catalog No. 800T-N300 (F)
NOTE: Dimensions
in parentheses are in
millimeters.
9/16" (14.3)
1/4" (6.4) Dia. Drill
(Alternate)
Preferred
Mounting Instructions Gaskets Required for Various Panel Thicknesses
Products with octagonal
mounting rings
3
3
Fig. 2
Fig. 1
Fig. 3
4
2
1
Panel Thickness Panels thicker than 3/16” (4.8)
must be counterbored
Number of 1/16” (1.6)
Gaskets shipped
with the product
Panels thicker than 1/4” (6.4)
must be counterbored
16 Gage 1/16” (1.6)
12 Gage 7/64” (2.8)
10 Gage 9/64” (3.6)
3/16” (4.8)
1/4” (6.4)
Pilot lights with
knurled mounting rings
43/64" (17.1)
11/64" (4.4)
2-1/4"
(57.2)
1-27/32"
(46.8)
1-13/64" (30.6) Dia.
Minimum
Spacing
4
3
2
1
Mounting Ring
Must Not Interfere
With Lens
Illuminated Push Button or
Push-To-Test Pilot Light
800H Pilot Light Push-Pull And Twist To
Release Push Button And
Mushroom Head Push Button
Tighten Lens or Cap To
Provide For A Tight Seal
Thrust Washer
Gaskets
Panel
Notch
Trim Washer Legend Plate
(Tang Engages Panel)
Octagonal
Mounting
Ring
Bayonet Base Lamp
Incandescent or
Neon
LED
Tighten Lens or Cap To
Provide For A Tight Seal
When jumbo Legend Plate is used, spacing is 2-1/2”(63.5).
When large (Automotive) Legend Plate is used, spacing is 2-1/2” (63.5).
or
A
AB
B
A
To determine the contact targets of Allen-Bradley 800T and 800H Momentary Push Buttons, 2 and 3 position Push-Pull Push Buttons, and 2 position Twist-release Push Buttons, proceed as follows.
1. Identify the CONTACT BLOCK used by looking at the contact block cover plate and nding a Catalog No. such as 800T-XA.
2. Identify the CIRCUIT for which the contact target is desired by looking again at the contact block cover plate for a wiring symbol such as “A”, “B”, “A1”, etc.
3. Refer to Fig 5 and nd the contact block and wiring symbol.
Read across the top to nd the Lens or Cap position. (IN, CENTER, or OUT)
The contact target is at the intersection of the contact block row and position column.
Dual Input Module Kits: 800T-N290 (120 Vac Full Voltage) Power module and lamp
800T-N291 (24 Vac Full Voltage) Power module and lamp
800T-N296 (120 Vac Transformer Type) Relay module.
Flashing Lamp (6V): 800T-N212 Available for any illuminated device which uses the ANSI No. 755 or No. 1866 lamp.
Lamp Installer: 800T-N82 Useful for installation or replacement of incandescent lamps
LED Lamps and Power Modules for extended lamp life:
(Consult A-B Catalog for ordering information)
The contact blocks listed below may be mounted in various combinations on an operator. See operator instruction sheet for any additional contact block limitations.
Two Tiers High Maximum (for mounting instructions see contact block instruction sheet)
Illuminated Push Button Operators Accept One (1) or Two (2) Contact blocks
Non-Illuminated Push Button Operators Accept One (1) to Four (4) Contact blocks
3 position Push-Pull Only
Using the NCLB Contact function on 2 position Push-Pull and 2 position Twist-Release causes the following:
When the button is pushed from the “OUT” to the“IN” position, the mechanical detent action of the operator occurs before the contacts change state.
When the button is pulled from the “IN” to the “OUT” position, the contacts change state before the mechanical detent action of the operator occurs.
800T-XA2 contact blocks must be used only on the second level if stacked.
Mini-blocks may be used on the second level only.
Sealed Switch blocks are not stackable and may be used one tier high maximum.
Standard Block
Cat. No. 800T/TC-
Self Monitoring
Cat. No. 800TC-
Mini-Block
Cat. No. 800T-
Sealed Switch Block
Cat. No. 800T-
Logic Reed Block
Cat. No. 800T-
Number of
Contacts
XA
XA1
XA2
XA4
XA7
XD1
XD2
XD3
XD4
7–
–
–
–
–
–
–
–
XD4S
–
–
–
–
–
XD5
XD6
–
–
XAP
–
–
–
–
XD1P
XD2P
–
–
XAR
–
XA2R
XA4R
–
XD1R
XD2R
–
–
1 N.O.-1 N.C.
1 N.O.-1 N.C. (Late Break)
2 N.O.
2 N.C.
1 N.C.-1 N.C. (Late Break)
1 N.O.
1 N.C.
1 N.O. (Early Make)
1 N.C. (Late Break)
Series C or later Series A or later Series B or later Series E or laterSeries D or later Series A or later
PenTUFF Block
Cat. No. 800T/TC-
XAV–
–
–
–
–
XD1V
XD2V
XD3V
XD4V
2 Circuit
Contact Block
Cat. No. 800T-
Single Circuit
Contact Block
Cat. No. 800T-
Normal
Circuit
Operation
Wiring
Symbol
OUT
Position
IN
Position
CENTER
Position
XA, XAR, XAP
XA1
XA2, XA2R
XA4, XA4R
XA7
–
–
XD2, XD6, XD2R, XD2P
XD1, XD5, XD1R, XD1P
XD1, XD5, XD1R, XD1P
XD1, XD5, XD1R, XD1P
XD1, XD5, XD1R, XD1P
XD4
XD4
XD3
XD4
N.C.
N.C.
N.C.
N.O.
N.O.
N.O.
N.O.
N.C.L.B.
N.C.L.B.
B
A
BZ
A1
A2
XD2, XD6, XD2R, XD2P
XD2, XD6, XD2R, XD2P
XD2, XD6, XD2R, XD2P
N.C. B1
B2
BZ
N.O.E.M. AZ
BZ
A
X
O
X
O
O
O
X
X
X
O
O
O
X
O
O
O
O
O
X
X
O
X
O
X
X
X
O
O
O
N.C.L.B.
BXOO
X
XXO
4
8 8
Self Monitoring Block to be used only on 2 position devices. Only functional on level 1.
Contact blocks with normally closed contacts meet direct drive positive opening standard requirements when properly fused to IEC 269-1
and 269-2. Shallow/mini contacts: 10 A gl or N type cartridge fuse. PenTUFF contacts: 6 A gl or N type cartridge fuse.
Available Accessories for 800T and 800H Illuminated Device
Contact Blocks for 800T and 800H Push Buttons
Contact Target Table
Abbreviations and Symbols
NO = Normally Open NC = Normally Closed EM = Early Make LB = Late Break O = Open X = Closed
Fig. 5
Fig. 4
40061-052-01
DIR 40061-052 (Version 11)
Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 800T-IN004K-EN-E - April 2013
8
67
78
4
5
6
7
1
8
8
7
7
28
27
7
7
7
8
7
8
7
8
1 8
8
WARNING: Only Sealed Switch and Logic Reed Blocks may be used on devices rated for Class I, Division 2 Hazardous Locations.
Substitution of the contact block may impair suitability for Division 2.
Exposure to some chemicals may degrade the sealing properties of materials used in the sealed contact blocks.
Normally Open (NO) contacts, sealed switch contact blocks and logic reed contact blocks can not be used for emergency stop control circuits.
WARNING: 800T-N296 is not rated for Class I Division 2 Hazardous Location.
5
5
5
3
3
3
1
2
3

Other manuals for PanelView 800

1

This manual suits for next models

1

Other Allen-Bradley Controllers manuals

Allen-Bradley SLC 500 User manual

Allen-Bradley

Allen-Bradley SLC 500 User manual

Allen-Bradley ArmorStart 290E User manual

Allen-Bradley

Allen-Bradley ArmorStart 290E User manual

Allen-Bradley PowerFlex 7000 User manual

Allen-Bradley

Allen-Bradley PowerFlex 7000 User manual

Allen-Bradley PowerFlex 400 Instruction manual

Allen-Bradley

Allen-Bradley PowerFlex 400 Instruction manual

Allen-Bradley 22C-B012N103 User manual

Allen-Bradley

Allen-Bradley 22C-B012N103 User manual

Allen-Bradley Bulletin 161 B Series User manual

Allen-Bradley

Allen-Bradley Bulletin 161 B Series User manual

Allen-Bradley PowerFlex 70 User manual

Allen-Bradley

Allen-Bradley PowerFlex 70 User manual

Allen-Bradley micrologix 1500 User manual

Allen-Bradley

Allen-Bradley micrologix 1500 User manual

Allen-Bradley AADvance User manual

Allen-Bradley

Allen-Bradley AADvance User manual

Allen-Bradley 1785-L11B User manual

Allen-Bradley

Allen-Bradley 1785-L11B User manual

Allen-Bradley PowerFlex 753 User manual

Allen-Bradley

Allen-Bradley PowerFlex 753 User manual

Allen-Bradley PowerFlex 70 User manual

Allen-Bradley

Allen-Bradley PowerFlex 70 User manual

Allen-Bradley PowerFlex 755TL User manual

Allen-Bradley

Allen-Bradley PowerFlex 755TL User manual

Allen-Bradley Bulletin 900-TC Series User manual

Allen-Bradley

Allen-Bradley Bulletin 900-TC Series User manual

Allen-Bradley GuardLogix 5580 User manual

Allen-Bradley

Allen-Bradley GuardLogix 5580 User manual

Allen-Bradley 1756-CN2/B User manual

Allen-Bradley

Allen-Bradley 1756-CN2/B User manual

Allen-Bradley PowerFlex 525 User manual

Allen-Bradley

Allen-Bradley PowerFlex 525 User manual

Allen-Bradley Bulletin 505 User manual

Allen-Bradley

Allen-Bradley Bulletin 505 User manual

Allen-Bradley powerflex 700 User manual

Allen-Bradley

Allen-Bradley powerflex 700 User manual

Allen-Bradley 140G-M-F Series User manual

Allen-Bradley

Allen-Bradley 140G-M-F Series User manual

Allen-Bradley 1756 ControlLogix User manual

Allen-Bradley

Allen-Bradley 1756 ControlLogix User manual

Allen-Bradley CompactLogix 5480 User manual

Allen-Bradley

Allen-Bradley CompactLogix 5480 User manual

Allen-Bradley MicroLogix 1400 User manual

Allen-Bradley

Allen-Bradley MicroLogix 1400 User manual

Allen-Bradley 1769 CompactLogix User manual

Allen-Bradley

Allen-Bradley 1769 CompactLogix User manual

Popular Controllers manuals by other brands

Mini-Circuits ZHL-2425-250X+ Mounting instructions

Mini-Circuits

Mini-Circuits ZHL-2425-250X+ Mounting instructions

Datapath VSNMicro N600 quick start guide

Datapath

Datapath VSNMicro N600 quick start guide

ALLEN & HEATH iDR-4 Service information

ALLEN & HEATH

ALLEN & HEATH iDR-4 Service information

Ruida Technology LFS-PM-T43 operating manual

Ruida Technology

Ruida Technology LFS-PM-T43 operating manual

Harman Kardon CITATION 5.0 Quick start instructions

Harman Kardon

Harman Kardon CITATION 5.0 Quick start instructions

TIANJIN BAILI ERTONG MACHINERY SMC Series Operation manual

TIANJIN BAILI ERTONG MACHINERY

TIANJIN BAILI ERTONG MACHINERY SMC Series Operation manual

Altec MTC35-F22 instruction manual

Altec

Altec MTC35-F22 instruction manual

Roger MC16 operating manual

Roger

Roger MC16 operating manual

Lumel re72 series User Manual & Quick Start

Lumel

Lumel re72 series User Manual & Quick Start

ZPA Pecky, a.s. MODACT MOK 125 Installation and operating instructions

ZPA Pecky, a.s.

ZPA Pecky, a.s. MODACT MOK 125 Installation and operating instructions

Specialwaves Mine S user guide

Specialwaves

Specialwaves Mine S user guide

Rockwell Automation MagneMotion 700-0871-00 user manual

Rockwell Automation

Rockwell Automation MagneMotion 700-0871-00 user manual

CAL Controls CAL 9500P Abridged user manual

CAL Controls

CAL Controls CAL 9500P Abridged user manual

Recoil RB1 user manual

Recoil

Recoil RB1 user manual

Bibby Sterilin Techne TU-20D Operator's manual

Bibby Sterilin

Bibby Sterilin Techne TU-20D Operator's manual

ICP DAS USA uPAC-7186EG Getting started

ICP DAS USA

ICP DAS USA uPAC-7186EG Getting started

Barco EC Series Safety guide

Barco

Barco EC Series Safety guide

Parker 650 Series product manual

Parker

Parker 650 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.