
- 2 - Isolated 220 Series
Overview:
Altronix Isolated CCTV Power Supplies provide 24VAC distributed via eight (8) or sixteen (16) fuse or PTC
protected isolated outputs for powering CCTV cameras, heaters, and other video accessories.
Isolated Power Supply Reference Chart:
Altronix
Model Number
Output
Voltage
Total
Output
Current
Number
of
Outputs
PTC Protected
auto-resettable
Outputs
Fuse
Protected
Outputs
Output
Current
(max per
output)
220VAC
50/60Hz
Input
Current
ALTV248Hi220 24VAC 14A 8 – P1.75A
2.7A
ALTV248CBHi220 24VAC 8 P–
ALTV248Mi220 24VAC 12.5A 8 – P1.6A
ALTV248CBMi220 24VAC 8 P–
ALTV2416i220 24VAC 28A 16 – P1.75A 5.4A
ALTV2416CBi220 24VAC 16 P-
Specifications:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with
all local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pgs. 7, 8). Secure enclosure to earth ground.
2. Set power switch to OFF position on all models (Figs. 1 - 3, pgs. 4 - 6).
3. All units are factory set for 24VAC operation.
4. Secure green lead to earth ground. Connect AC power to the black and white flying leads of the
transformer(s) (Figs. 1 - 3, pgs. 4 - 6). Use 18 AWG or larger for all power connections.
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1A - 8A] and [1B - 8B] are of the same polarity (phase).
6. Connect CCTV cameras to output terminals using the following procedure:
Camera 1 to output 1A & 1B. Camera 5 to output 5A & 5B.
Camera 2 to output 2A & 2B. Camera 6 to output 6A & 6B.
Camera 3 to output 3A & 3B. Camera 7 to output 7A & 7B.
Camera 4 to output 4A & 4B. Camera 8 to output 8A & 8B.
7. Set power switch on all models to the “RESET” (ON) position (Figs. 1 - 3, pgs. 4 - 6).
8. Upon completion of the wiring, secure enclosure door with screws (supplied).
CAUTION: Equipment to be installed/serviced by authorized/trained personnel only.
Shut branch circuit power before installing/servicing equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to the National
Electrical Code and all local codes.
Replace fuses with the same type and rating (3.5A/250V).
Input:
• 220VAC, 50/60Hz.
Output:
• Eight (8) or sixteen (16) fuse or PTC
protected outputs.
• 24VAC outputs.
• Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
• Surge suppression.
Features:
• Individual electronically isolated outputs.
• Illuminated master Power ON/OFF switch
with built-in circuit breaker.
Features (cont’d):
• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates
costly labor.
• Spare fuses included (on fuse protected models).
Enclosure Dimensions (H x W x D approx.):
ALTV248Mi220, ALTV248UCBMi220:
8.5” x 7.5” x 3.75” (215.9mm x 190.5mm x 97.9mm).
ALTV248Hi220, ALTV248CBHi220,
ALTV2416i220, and ALTV2416CBi220:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm).