Installation Instructions:
OLS120D2 should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Mount the OLS120D2 in the desired location/enclosure.
2. Slide [Power ON/OFF] switch to the OFF position (Fig. 1c, pg. 2).
3. Set the DC1 output voltage via clip switch - open for 24VDC operation or closed for 12VDC operation (Fig. 1a and 1b, pg. 2).
DC2 output voltage is fixed at 12VDC operation.
CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment.
There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.
4. Connect AC power to the terminals marked [L & N], connect ground to the terminal marked [G].
Use 18 AWG or larger for all power connections (Battery, DC output).
Use 22 AWG to 18 AWG for power-limited circuits (AC Fail/Low Battery reporting).
5. Slide [Power ON/OFF] switch to the ON position (Fig. 1c, pg. 2).
6. Measure output voltage across both out terminals marked [– DC1 +, – DC2 +] before connecting devices.
This helps avoiding potential damage.
7. Slide [Power ON/OFF] switch to the OFF position (Fig. 1c, pg. 2).
8. Connect 12VDC or 24VDC (depending on clip switch setting) device to be powered to the terminals marked [– DC1 +].
Connect 12VDC device to be powered to the terminals marked [– DC2 +] (Fig. 1, pg. 2).
9. When use of stand-by batteries is desired, they must be lead acid or gel type.
Connect battery/batteries to the terminals marked [– BAT + ] (Fig. 1, pg. 2).
12VDC operation only: Use one (1) 12VDC battery for 12VDC backup.
24VDC and 12VDC simultaneous operation: Use two (2) 12VDC batteries connected in series for 24VDC backup.
10. When batteries are not used, a loss of AC will result in the loss of output voltage.
11. Connect appropriate signaling notification devices to AC Fail & Low battery supervisory relay outputs marked [NC, C, NO].
12. Slide [Power ON/OFF] switch to the ON position (Fig. 1c, pg. 2).
Maintenance:
Unit should be tested at least once a year for the proper operation as follows:
Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level.
Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage
(12VDC @ 13.7 or 24VDC @ 27.4) both at the battery terminal and at the board terminals marked [-- BAT + ] to
ensure that there is no break in the battery connection wires.
Note: Maximum charging current under discharges is 0.7A.
Note: Expected battery life is 5 years; however, it is recommended changing batteries in 4 years or less if needed.
Input:
• Universal input 115VAC, 50/60Hz, 0.95A or 230VAC, 50/60Hz, 0.6A.
• Input fuse rated @ 5A/250V.
Output:
• Output options:
- DC1: 12VDC or 24VDC @ 3A.
DC2: 12VDC @ 1A.
Note: If DC2 is not used, DC1 rating is
12VDC or 24VDC rated @ 4A max.
• Filtered and electronically regulated output.
• Short circuit and thermal overload protection.
Supervision:
• AC fail supervision (form “C” contacts).
• Low battery supervision (form “C” contacts).
Battery Backup:
• Built-in charger for sealed lead acid or gel type batteries.
• Automatic switch over to stand-by battery when AC fails.
• Maximum charge current 0.7A.
Visual Indicators:
• AC input and DC output LED indicators.
Features:
• Power ON/OFF switch (interrupts mains) (Fig. 1c, pg. 2).
• Includes battery leads.
Board Dimensions (W x L x H):
4.5” x 7.25” x 1.75” (114.3mm x 184.1mm x 44.5mm).
OLS120D2
Dual Output Off-Line Power Supply/Charger
Overview:
OLS120D2 power supply/charger converts a 115VAC, 50/60Hz or 230VAC, 50/60Hz input to a 12VDC/24VDC output and a 12VDC fixed output
(see specifications). This unit has a wide range of applications for access control and security system accessories that require additional power.
Specifications:
LED Diagnostics:
Red (DC1) Green (AC) Power Supply Status
ON ON Normal operating condition.
ON OFF Loss of AC. Stand-by battery supplying power.
OFF ON No DC output. Short circuit or thermal overload condition.
OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output.
Terminal Identification:
Terminal Legend Function/Description
L, G, N Connect 115VAC/230VAC to these terminals: L to Hot, N to Neutral, G to ground.
– DC1 + DC1: 12VDC or 24VDC @ 3A and DC2: 12VDC @ 1A
Note: If DC2 is not used, DC1 rating is 12VDC or 24VDC rated @ 4A max.
– DC2 + 12VDC @ 1A.
AC FAIL
NC, C, NO
Indicates loss of AC power, e.g. connect to audible device or alarm panel. Relay normally
energized when AC power is present. Contact rating 1A @ 115VAC / 28VDC
Low Battery
NC, C, NO
Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when
DC power is present. Contact rating 1A @ 115VAC / 28VDC.
Low battery threshold: 12VDC output threshold set @ approximately 10.5VDC,
24VDC output threshold set @ approximately 21VDC.
– BAT + Stand-by battery connections. Maximum charge rate 0.7A.
Fig. 1
Fig. 1a
Fig. 1b
LG N
OFF ON
OPEN - 24VDC
CLOSED - 12VDC
DC1 SETTING
LOW BAT
NC C NO NC C NO
AC FAIL --- BAT + --- DC1 +
AC DC
--- DC2 +
5A 250V
OPEN - 24VDC
CLOSED - 12VDC
DC1 SETTING
OPEN 24VDC
CLOSED 12VDC
Switch Detail
LG N
OFF ON
OPEN - 24VDC
CLOSED - 12VDC
DC1 SETTING
LOW BAT
NC C NO NC C NO
AC FAIL --- BAT + --- DC1 +
AC DC
--- DC2 +
5A 250V
Fig. 1c
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIOLS120D2 - Rev. 062113 H30U MEMBER

Other Altronix Power Supply manuals

Altronix SMP5CTX220 Series User manual

Altronix

Altronix SMP5CTX220 Series User manual

Altronix Trove T3MK7716S User manual

Altronix

Altronix Trove T3MK7716S User manual

Altronix ALTV244-300/220 User manual

Altronix

Altronix ALTV244-300/220 User manual

Altronix ALTV244 Series User manual

Altronix

Altronix ALTV244 Series User manual

Altronix ALTV2432 Series User manual

Altronix

Altronix ALTV2432 Series User manual

Altronix AL600X220 Series User manual

Altronix

Altronix AL600X220 Series User manual

Altronix MAXIMAL FIT MaxFit E Series User manual

Altronix

Altronix MAXIMAL FIT MaxFit E Series User manual

Altronix SMP7PM User manual

Altronix

Altronix SMP7PM User manual

Altronix AL400ULXB User manual

Altronix

Altronix AL400ULXB User manual

Altronix SMP5E Service manual

Altronix

Altronix SMP5E Service manual

Altronix ALTV2416UL3 Series User manual

Altronix

Altronix ALTV2416UL3 Series User manual

Altronix ALTV164 User manual

Altronix

Altronix ALTV164 User manual

Altronix AL100UL User manual

Altronix

Altronix AL100UL User manual

Altronix SMP3CTX220 Series User manual

Altronix

Altronix SMP3CTX220 Series User manual

Altronix SMP5 User manual

Altronix

Altronix SMP5 User manual

Altronix SMP5CT Series Operating and maintenance instructions

Altronix

Altronix SMP5CT Series Operating and maintenance instructions

Altronix AL300ULPD4 User manual

Altronix

Altronix AL300ULPD4 User manual

Altronix ALTV615DC44UCBM User manual

Altronix

Altronix ALTV615DC44UCBM User manual

Altronix AL600ULX Series User manual

Altronix

Altronix AL600ULX Series User manual

Altronix LPS3AC Service manual

Altronix

Altronix LPS3AC Service manual

Altronix eFLOW eFlow104NKA8D Series User manual

Altronix

Altronix eFLOW eFlow104NKA8D Series User manual

Altronix AL100UL User manual

Altronix

Altronix AL100UL User manual

Altronix ALTV248220 Series User manual

Altronix

Altronix ALTV248220 Series User manual

Altronix Maximal1RHD User manual

Altronix

Altronix Maximal1RHD User manual

Popular Power Supply manuals by other brands

XPG PYLON BRONZE Series manual

XPG

XPG PYLON BRONZE Series manual

GW Instek PSM-2010 user manual

GW Instek

GW Instek PSM-2010 user manual

APM SPS Series quick guide

APM

APM SPS Series quick guide

LEAB LPS Series user manual

LEAB

LEAB LPS Series user manual

Assa Abloy Securitron BPS-12-1 Operation and installation instructions

Assa Abloy

Assa Abloy Securitron BPS-12-1 Operation and installation instructions

CAMBRIONIX PP15S user manual

CAMBRIONIX

CAMBRIONIX PP15S user manual

GW Instek SPS Series manual

GW Instek

GW Instek SPS Series manual

Western Co WRM15 dualB Technical manual

Western Co

Western Co WRM15 dualB Technical manual

KNX Module PS-S.640.30.1 user manual

KNX

KNX Module PS-S.640.30.1 user manual

ADTRAN 61175044L2-22B Job aid

ADTRAN

ADTRAN 61175044L2-22B Job aid

NZXT E 500 manual

NZXT

NZXT E 500 manual

Listen Technologies LBB 400D Specification sheet

Listen Technologies

Listen Technologies LBB 400D Specification sheet

Telecom SPS-1335 instruction manual

Telecom

Telecom SPS-1335 instruction manual

Tannoy VNet manual 

Tannoy

Tannoy VNet manual 

Banner FlexPower DX81P6 Specification sheet

Banner

Banner FlexPower DX81P6 Specification sheet

Pulsar HPSB 5524C quick start guide

Pulsar

Pulsar HPSB 5524C quick start guide

TDK-Lambda Genesys Series user manual

TDK-Lambda

TDK-Lambda Genesys Series user manual

Elmdene GEN2-08 Series instruction sheet

Elmdene

Elmdene GEN2-08 Series instruction sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.