Amewi METEOR AM8G User manual


1
INDEX
2
Multi-Functional Switch
*Select: turn left/right
*Enter/Set/Stop: press
PRODUCT CONTAINS
Charger x1
DC Input Clip
Charge Cable x1
Instruction Manual x1
Balance Socket adapter x1
128x64 Pixel LCD Screen
Cooling Fan
Balance Port
Temperature Sensor Port
DC Input Wire(14AWG 50cm)
Charge Output Socket
Below items are included in the package, contact your supplier if any item is miss.
Thank you for purchasing CASALRC DC balance charger/discharger.
For your convenience and safety, please read this manual carefully before using
this product.
It’s a professional and high efficiency balance charger/discharger which is
especially designed for charging/discharging LiPo , LiFe, LiIo, NiMH, NiCd and PB
batteries.
C8G
FOREWORD
Rubber feet x4pcs
FOREWORD
PRODUCT CONTAINS
OPTIONAL ACCESSORIES
SPECIFICATION
FEATURES
WARNING and NOTES
BATTERIES and MAX CHARGE CURRENT
SYSTEM SETTING
CHARGE/DISCHARGE LIPO BATTERY
CHARGE/DISCHARGE LIFE BATTERY
CHARGE/DISCHARGE LIIO BATTERY
CHARGE/DISCHARGE NIMH BATTERY
CHARGE/DISCHARGE NICD BATTERY
CHARGE/DISCHARGE PB BATTERY
NOTES and REMARK of WORKING STATUS
MONITOR
BATTERY IN SERIES/PARALLEL CHARGE
WARRANTY
LIABILITY EXCLUSION
CONFORMITY DECLARATION
p2
p2
p3
p3
p4
p5
p6-7
p8
p9-12
p13-16
p17-20
p21-23
p24-26
p27-29
p30
p31
p32
p33
p33
p34

3 4
SPECIFICATION
OPTIONAL ACCESSORIES
2x3S in series Adapter
2x2S in series Adapter
FEATURES
High efficiency synchronous DC-DC circuit. Special advanced charging
technology ensure a fast and precision charging performance.
The CASALRC balance chargers series has a integrated cell balancer
which can especially used for charging the LiPo, Lilo, LiFe, NiMH, NiCd and
Pb batteries.
10 battery profile memories, 1 default memory of latest profile, 9 custom
memories can be save and load by the user.
128x64 pixel LCD screen shows rich information: input voltage,
outputl current, charge capacity (mAh), charge time, temperature, cell voltage,
cell voltage difference etc.
Various functional settings can meet a wide range of use. Balance charge,
normal charge, fast charge, storage and discharge for Lithium batteries.
charge, charge, cycle and discharge for NiCd/NiMH batteries. Charge,
cycle and discharge for Pb batteries.
Various system settings: backlight, contrast, key sound, safty time,
temperature , capacity , power limited and input voltage cutoff.
Full protection system: protection of reversed polarity (input and output),
higher/lower input voltage, power supplymbattery temperature, over
charge/discharge and time limited.
C8G
output voltage,
auto-
manual-
cutoff cutoff
Temperature Sensor(magnet)Parallel Adapter
AM8G
Input voltage range: 11.0-30.0V DC
Charge current range: 0.1-20.0A
Discharge current range: 0.1-20.0A
Maximum charge power: 400W
Maximum discharge power: 20W
Current drain for balancing: 400mA
Balance accuracy: <10mV
LiPo/LiIo/LiFe battery cell count: 1-8 series
NiCd/NiMH battery cell count: 1-20 series
Pb battery cell count: 1-12 series (2-24V)
Battery setup memories: 10
Temperature sensor: Yes
Weight: 433g
Dimension(LxWxD): 145X103X35mm

CASALRC 8G is ONLY suitable for charge rechargeable LiPo, LiFe,
LiIo,NiMH and PB batteries. Do not attempt to charge dry cells. Charge
other types of batteries may cause fire or explosion.
Never leave the charger unattended when it is working. If you leave,
disconnect the battery to prevent any unexpected dangerous or
damage.
The prescript DC input voltage range from 11-30V. Never connect it to
any other power supply which is unsuitable.
Ensure program and settings match the battery pack, incorrect setting
to charge/discharge a battery may damage the battery, even would
cause a fire.
Protect charger from dust, dirt and damp. Do not attempt to
disassemble the charger, contact the after sales center for
maintenance if needed.
Never place the charger and batteries connected to it on any form of
flammable surface. Never operate the charger in the vicinity of
inflammable material or gas.
Ensure that there is an unrestricted airflow to and from the charger's
cooling slots.
Never charge or discharge any battery having evidence of leaking,
expansion/swelling, damaged outer cover or case, color-change or
distortion.
Take great care to maintain correct battery polarity, and avoid
shot-circuit. Read the battery manufacturer's instructions and adhere
to them strictly.
BATTERIES and MAX CHARGE CURRENTWARNING and NOTES
5 6
B a tt ery T y p e N o . o f C e lls R a te d V o lt ag e (V ) M a x C h a rg e C u rre nt (A )
fo r 4 0 0W
1 3.7 20 .0
2 7.4 20 .0
3 11 .1 20 .0
4 14 .8 20 .0
5 18 .5 20 .0
6 22 .2 18 .0
7 25 .9 15 .4
8 29 .6 13 .5
1 3.3 20 .0
2 6.6 20 .0
3 9.9 20 .0
4 13 .2 20 .0
5 16 .5 20 .0
6 19 .8 20 .0
7 23 .1 17 .3
8 26 .4 15 .2
1 3.6 20 .0
2 7.2 20 .0
3 10 .8 20 .0
4 14 .4 20 .0
5 18 20 .0
6 21 .6 18 .5
7 25 .2 15 .9
8 28 .8 13 .9
1 1.2 20 .0
2 2.4 20 .0
3 3.6 20 .0
4 4.8 20 .0
5 6 20.0
6 7.2 20 .0
7 8.4 20 .0
8 9.6 20 .0
9 10 .8 20 .0
N iM H 10 1 2 2 0 .0
11 1 3 .2 20 .0
L ip o
L iF e
L iIo

7 8
SYSTEM SETTING
BACKLIGHT:
Range from 0-100%
*Select: turn left/right
*Enter/Set/Stop: press
CONTRAST:
Range from 0-100%
KEY SOUND:
On/Off optional
SAFTY TIME:
Charge/discharge time
limit, range from 10-1000
minutes. Off=no limit.
TEMPERATURE CUTOFF:
Battery upper temperature
limit. Range from 20-100 °C.
Off=no limit.
CAPACITY CUTOFF:
Battery capacity protection.
Range from 100-99999 mAh.
Off=no limit.
STANDBY Menu
Default memory(the parameter
setting of last work of the charger)
Press “START” charger will
directly work under default
memory.
Press “LOAD”, parameter will
change to the memory you load,
press “START” charger will work
under the setting of the memory.
I_V CUTOFF:
Power supply protection.
Range from 11-30 V.
Default:11V
POWER LIMIT:
Range from 50-300 W.
Power supply protection.
Default:300W
12 14,4 20,0
13 15,6 20,0
14 16,8 20,0
15 18 20,0
16 19,2 20,0
17 20,4 19,6
18 21,6 18,5
19 22,8 17,5
20 24 16,7
NiCd
1 2 20,0
2 4 20,0
3 6 20,0
4 8 20,0
5 10 20,0
6 12 20,0
7 14 20,0
8 16 20,0
9 18 20,0
10 20 20,0
11 22 18,2
12 24 16,7
Lipo
LiFe
LiIo
NiMH
NiCd
PB
same as NiMH
Voltage Level: 1.2V/cell
Max Charge Voltage: 1.6V/cell
Discharge Voltage Cut off Level: 0.85V/cell or higher
Voltage Level: 1.2V/cell
Max Charge Voltage: 1.6V/cell
Discharge Voltage Cut off Level: 1.0V/cell or higher
Voltage Level: 2.0V/cell
Max Charge Voltage: 2.45V/cell
Discharge Voltage Cut off Level: 1.75V/cell or higher
PB
Voltage Level: 3.7V/cell
Max Charge Voltage: 4.2V/cell
Discharge Voltage Cut off Level: 3.0V/cell or higher
Voltage Level: 3.3V/cell
Max Charge Voltage: 3.6V/cell
Discharge Voltage Cut off Level: 2.0V/cell or higher
Voltage Level: 3.6V/cell
Max Charge Voltage: 4.1V/cell
Discharge Voltage Cut off Level: 2.7V/cell or higher
BACKLIGHT
CONTRAST
KEY
SAVE
SYSTEM SETTING
SAFTY
TEMP
BACK
60
80
ON
140
99
SOUND
TIME
CUT
OFF
CAP
CUT
OFF 5000
C
MIN
MAH
BACKLIGHT
CONTRAST
KEY
SAVE
SYSTEM SETTING
SAFTY
TEMP
BACK
60
80
ON
140
99
SOUND
TIME
CUT
OFF
CAP
CUT
OFF 5000
C
MIN
MAH
BACKLIGHT
CONTRAST
KEY
save
SYSTEM SETTING
SAFTY
TEMP
BACK
60
80
ON
140
99
SOUND
TIME
CUT
OFF
CAP
CUT
OFF 5000
C
MIN
MAH
Backlight
CONTRAST
KEY
SAVE
SYSTEM SETTING
SAFTY
TEMP
BACK
60
80
on
140
99
SOUND
TIME
CUT
OFF
CAP
CUT
OFF 5000
C
MIN
MAH
BACKLIGHT
CONTRAST
KEY
SAVE
SYSTEM SETTING
SAFTY
TEMP
BACK
60
80
ON
140
99
SOUND
TIME
CUT
OFF
CAP
CUT
OFF 5000
C
MIN
MAH
BACKLIGHT
CONTRAST
KEY
SYSTEM SETTING
SAFTY
TEMP
60
80
on
140
99
SOUND
TIME
CUT
OFF
CAP
CUT
OFF 5000
C
MIN
MAH
SAVE BACK
BACKLIGHT 60
POWER LIMIT
SAVE
SYSTEM SETTING
BACK
250
I V
CUT
OFF 11 00 V
POWER LIMIT
SAVE
SYSTEM SETTING
BACK
300
I V
CUT
OFF 11 00 V
W
W
LIPO
BAL CHG
AUTO
A0010
MV4200
STANDBY
Monitor Start
Sys Load Menu
C

9 10
CHARGE/DISCHARGE LIPO BATTERY
*Select: turn left/right
*Enter/Set/Stop: press
Select the cell count of the battery, range from 1-6 .
Important note: Except balance charge mode, charger can not detect the correct cell count
of the battery which has voltage intersection with the other one. So the cell count you
sellect must be exact the same as your battery, otherwise may cause dangerous situation.
In balance charge mode
automatically detect the cell count of the battery.
, charger can
Select the max charge/discharge current.
Range from 0.1-20.0, change unit: 0.1-20.0
C-CUR: Charge current
Range from 0.1-20.0, change unit: 0.1-20.0
D-CUR: Discharge current
Terminal Voltage Control.
C-TVC: TVC of Charge
Range from 2500-4200, change unit: 10, default: 3000
Range from 4100-4250, change unit: 10, default: 4200
D-TVC: TVC of Discharge
(Storage mode range from 3800-3900, default: 3850)
Parameter setting Working stutus
BAL_CHG: Balance charge
STORAGE: Charge or discharge a battery according to the situation of the battery (balance
connector optional)
DISCHARGE: Discharge (balance connector optional)
(balance connector required)
CHARGE: Normal charge (balance connector not required)
FAST_CHG: Fast charge (balance connector not required)
CYCLE: Charge and discharge (balance connector optional)
BATT
MODE
TYPE
PRESENT SETTING
AC CUR
C TVC
BACK
LIPO
10 00
4200
LIPO
6S
A691
V60
I 12
MAH1958
3812
C6 4138 20
C5 4135 17
C4 4130 12
C3 4125 7
C2 4120 2
C1 4118 0
BATT
MODE
TYPE
CELLS
BACK
LIPO
CHARGE
6 S
BATT TYPE LIPO
CHARGING
SAVE
SAVE START
SAVE
BAT CELL mV
C
28
BATT
MODE
TYPE
CELL
CURRENT
TVC
SAVE
SAVE
BAL CHG
BATT
MODE
TYPE
SAVE
MV
RimΩ
4
7
5
4
2
1
STOP
V70
O 24
00
AC CUR
C TVC
10 00
4200 MV
PRESENT SETTING
START
BACK
START
BACK
START
BACK
START
BACK
START
LIPO
CHARGE
6S
A691
V60
I 12
MAH1958
3812
C
28
V70
O 24
00 STOP
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
LIPO
FAST CHG
6 S
A
10 00
4200 MV
CHARGING
LIPO
6S
A691
V60
I 12
MAH1958
3812
C
28
V70
O 24
00 STOP
FAST CH G
LIPO
STORAGE
6 S
A
5 00
3800 MV
CELLS
C CUR
C TVC
MODE DISCHARGE
6 S
A
5 00
3000 MV
CELLS
D CUR
D TVC
LIPO
STORAGE
6S
A691
V60
I 12
MAH158
3812
C6 4138 20
C5 4135 17
C4 4130 12
C3 4125 7
C2 4120 2
C1 4118 0
BAT CELL mV
C
28
RimΩ
STOP
V70
O 24
00
LIPO
STORAGE
6S
A691
V60
I 12
MAH158
3812
C
28
V70
O 24
00
BATT
MODE
TYPE LIPO
CYCLE
6 S
A
10 00
4200 MV
CELLS
C CUR
C TVC
A
5 00
D CUR
SAVE BACK
START
PRESENT SETTING
3000 MV
D TVC
CD
SEQUENCE
10 MIN
W TIME
1
TIMES
LIPO
6S
A691
V60
I 12
MAH1958
3812
C6 4138 20
C5 4135 17
C4 4130 12
C3 4125 7
C2 4120 2
C1 4118 0
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V70
O 24
00
CYCLE
DISCHARGING
STOP
CYCLE
BAL CHG
LIPO
BAL CHG
Auto
A0010
MV4200
STANDBY
Monitor Start
Sys Load Menu
C

11 12
Only in Cycle mode, select the charge/discharge sequence.
C D: charge to discharge
D C: discharge to charge
Only in Cycle mode, set the waste time between charge/discharge. Range from 0-60
minutes, change unit 1 .
Only in Cycle mode, set the times of charge/discharge cycle. Range from 1-9 times, change
unit 1 .
SEQUENCE
Save the current setting to 1st-9th memory.
Connect the battery, press start, charger will work under present setting.
Back to “STANDBY” menu.
SAVE
W-TIME
TIMES
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Battery cells
Cell voltage
Cell voltage difference
Balance Charge
External temperature
Working stutus
Input Voltage
Charge
Fast Charge
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Storage
External temperature
Input Voltage
Cell internal resistance
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Discharge
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Cycle
External temperature
Input Voltage
Battery cells
Cell voltage
Cell voltage difference
Cell internal resistance
Work finshed
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
LIPO
6S
A691
V60
I 12
MAH1958
3812
C6 4138 20
C5 4135 17
C4 4130 12
C3 4125 7
C2 4120 2
C1 4118 0
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V70
O 24
00
BAL CHG
CHARGING
LIPO
CHARGE
6S
A691
V60
I 12
MAH1958
3812
C
28
V70
O 24
00 STOP
CHARGING
LIPO
6S
A691
V60
I 12
MAH1958
3812
C
28
V70
O 24
00 STOP
FAST CHG
LIPO
STORAGE
6S
A691
V60
I 12
MAH158
3812
C6 4138 20
C5 4135 17
C4 4130 12
C3 4125 7
C2 4120 2
C1 4118 0
BAT CELL mV
C
28
RimΩ
STOP
V70
O 24
00
LIPO
DISCHARGE
6S
A691
V60
I 12
MAH158
C
28
V70
O 24 DISCHARGING
RimΩ
381200
LIPO
CYCLE
6S
A691
V60
I 12
MAH1958
3812
C6 4138 20
C5 4135 17
C4 4130 12
C3 4125 7
C2 4120 2
C1 4118 0
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V70
O 24
00
FINISHED
LIPO
6S
A690
V60
I 12
MAH2058
3820
C
28
V10
O 25
00 ENTER
BAL CHG
FINISHED
LIPO
6S
A690
V60
I 12
MAH2058
3818
C
28
V10
O 25
00 ENTER
CHARGE
FINISHED
LIPO
6S
A690
V60
I 12
MAH2058
3816
C
28
V10
O 25
00 ENTER
FAST CHG
FINISHED
LIPO
6S
A690
V60
I 12
MAH958
3850
C
28
V10
O 23
00 ENTER
STORAGE
FINISHED
LIPO
6S
A690
V60
I 12
MAH1958
3820
C
28
V10
O 20
01 ENTER
DISCHARGE
FINISHED
LiPo
6S
A690
V60
I 12
MAH2058
3830
C
28
V10
O 20
02 ENTER
CYCLE

13 14
CHARGE/DISCHARGE LIFE BATTERY
*Select: turn left/right
*Enter/Set/Stop: press
Select the cell count of the battery, range from 1-6 .
Important note: Except balance charge mode, charger can not detect the correct cell count
of the battery which has voltage intersection with the other one. So the cell count you
sellect must be exact the same as your battery, otherwise may cause dangerous situation.
In balance charge mode
automatically detect the cell count of the battery.
, charger can
Select the max charge/discharge current.
Range from 0.1-20.0, change unit: 0.1-20.0
C-CUR: Charge current
Range from 0.1-20.0, change unit: 0.1-20.0
D-CUR: Discharge current
Terminal Voltage Control.
C-TVC: TVC of Charge
Range from 1800-3600, change unit: 10, default: 2000
Range from 3500-3650, change unit: 10, default: 3600
D-TVC: TVC of Discharge
(Storage mode range from 3250-3350, default: 3300)
Parameter setting Working stutus
BAL_CHG: Balance charge
STORAGE: Charge or discharge a battery according to the situation of the battery (balance
connector optional)
DISCHARGE: Discharge (balance connector optional)
(balance connector required)
CHARGE: Normal charge (balance connector not required)
FAST_CHG: Fast charge (balance connector not required)
CYCLE: Charge and discharge (balance connector optional)
BATT
MODE
TYPE
PRESENT SETTING
AC CUR
C TVC
BACK
LIFE
10 00
3600
LIFE
6S
A691
V60
I 12
MAH1958
3812
C6 3538 20
C5 3535 17
C4 3530 12
C3 3525 7
C2 3520 2
C1 3518 0
BATT
MODE
TYPE
CELLS
BACK
LIFE
CHARGE
6 S
BATT TYPE LIFE
CHARGING
SAVE
SAVE START
SAVE
BAT CELL mV
C
28
BATT
MODE
TYPE
CELL
CURRENT
TVC
SAVE
SAVE
BAL CHG
BATT
MODE
TYPE
SAVE
MV
RimΩ
4
7
5
4
2
1
STOP
V10
O 21
00
AC CUR
C TVC
10 00
3600 MV
PRESENT SETTING
START
BACK
START
BACK
START
BACK
START
BACK
START
LIFE
CHARGE
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 21
00 STOP
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
LIFE
FAST CHG
6 S
A
10 00
3600 MV
CHARGING
LIFE
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 21
00 STOP
FAST CHG
LIFE
STORAGE
6 S
A
5 00
3300 MV
CELLS
C CUR
C TVC
MODE DISCHARGE
6 S
A
5 00
2000 MV
CELLS
D CUR
D TVC
LIFE
STORAGE
6S
A691
V60
I 12
MAH158
3812
C6 3538 20
C5 3535 17
C4 3530 12
C3 3525 7
C2 3520 2
C1 3518 0
BAT CELL mV
C
28
RimΩ
STOP
V10
O 21
00
LIFE
STORAGE
6S
A691
V60
I 12
MAH158
3812
C
28
V10
O 21
00
BATT
MODE
TYPE LIFE
CYCLE
6 S
A
10 00
3600 MV
CELLS
C CUR
C TVC
A
5 00
D CUR
SAVE BACK
START
PRESENT SETTING
2000 MV
D TVC
CD
SEQUENCE
10 MIN
W TIME
1
TIMES
LIFE
6S
A691
V60
I 12
MAH1958
3812
C6 3538 20
C5 3535 17
C4 3530 12
C3 3525 7
C2 3520 2
C1 3518 0
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V10
O 21
00
CYCLE
DISCHARGING
STOP
CYCLE
BAL CHG
LIPO
BAL CHG
AUTO
A0010
MV4200
STANDBY
Monitor Start
Sys Load Menu
C

15 16
Only in Cycle mode, select the charge/discharge sequence.
C D: charge to discharge
D C: discharge to charge
Only in Cycle mode, set the waste time between charge/discharge. Range from 0-60
minutes, change unit 1 .
Only in Cycle mode, set the times of charge/discharge cycle. Range from 1-9 times, change
unit 1 .
SEQUENCE
Save the current setting to 1st-9th memory.
Connect the battery, press start, charger will work under present setting.
Back to “STANDBY” menu.
SAVE
W-TIME
TIMES
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Battery cells
Cell voltage
Balance Charge
External temperature
Working stutus
Input Voltage
Charge
Fast Charge
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Storage
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Discharge
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Cycle
External temperature
Input Voltage
Battery cells
Cell voltage
Cell voltage difference
Cell internal resistance
Work finshed
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
LIFE
6S
A691
V60
I 12
MAH1958
3812
C6 3538 20
C5 3535 17
C4 3530 12
C3 3525 7
C2 3520 2
C1 3518 0
CHARGING
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V10
O 21
00
LIFE
CHARGE
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 21
00 STOP
CHARGING
LIFE
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 21
00 STOP
FAST CHG
LIFE
STORAGE
6S
A691
V60
I 12
MAH158
3812
C6 3538 20
C5 3535 17
C4 3530 12
C3 3525 7
C2 3520 2
C1 3518 0
BAT CELL mV
C
28
RimΩ
STOP
V10
O 21
00
LIFE
DISCHARGE
6S
A691
V60
I 12
MAH158
3812
C
28
V10
O 21
00
LIFE
CYCLE
6S
A691
V60
I 12
MAH1958
3812
C6 3538 20
C5 3535 17
C4 3530 12
C3 3525 7
C2 3520 2
C1 3518 0
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V10
O 21
00
DISCHARGING
STOP
BAL CHG
FINISHED
LIFE
6S
A690
V60
I 12
MAH2058
3820
C
28
V50
O 21
00 ENTER
BAL CHG
FINISHED
LIFE
6S
A690
V60
I 12
MAH2058
3818
C
28
V50
O 21
00 ENTER
FINISHED
LIFE
6S
A690
V60
I 12
MAH2058
3816
C
28
V50
O 21
00 ENTER
FINISHED
LIFE
6S
A690
V60
I 12
MAH958
3850
C
28
V80
O 19
00 ENTER
CHARGE
FAST CHG
STORAGE
FINISHED
LIFE
6S
A690
V60
I 12
MAH2058
3820
C
28
V10
O 13
01 ENTER
DISCHARGE
FINISHED
LIFE
6S
A690
V60
I 12
MAH1958
3830
C
28
V10
O 13
02 ENTER
CYCLE
Zellenspannungsdifferenz
Zellen Innenwiederstand

17 18
CHARGE/DISCHARGE LIIO BATTERY
*Select: turn left/right
*Enter/Set/Stop: press
Select the cell count of the battery, range from 1-6 .
Important note: Except balance charge mode, charger can not detect the correct cell count
of the battery which has voltage intersection with the other one. So the cell count you
sellect must be exact the same as your battery, otherwise may cause dangerous situation.
In balance charge mode
automatically detect the cell count of the battery.
, charger can
Select the max charge/discharge current.
Range from 0.1-20.0, change unit: 0.1-20.0
C-CUR: Charge current
Range from 0.1-20.0, change unit: 0.1-20.0
D-CUR: Discharge current
Terminal Voltage Control.
C-TVC: TVC of Charge
Range from 2400-4100, change unit: 10, default: 2700
Range from 4000-4150, change unit: 10, default: 4100
D-TVC: TVC of Discharge
(Storage mode range from 3700-3800, default: 3750)
Parameter setting Working stutus
BAL_CHG: Balance charge
STORAGE: Charge or discharge a battery according to the situation of the battery (balance
connector optional)
DISCHARGE: Discharge (balance connector optional)
(balance connector required)
CHARGE: Normal charge (balance connector not required)
FAST_CHG: Fast charge (balance connector not required)
CYCLE: Charge and discharge (balance connector optional)
BATT
MODE
TYPE
PRESENT SETTING
AC CUR
C TVC
BACK
LIIO
10 00
4100
LIIO
6S
A691
V60
I 12
MAH1958
3812
C6 4038 20
C5 4035 17
C4 4030 12
C3 4025 7
C2 4020 2
C1 4018 0
BATT
MODE
TYPE
CELLS
BACK
LIIO
CHARGE
6 S
BATT TYPE LIIO
CHARGING
SAVE
SAVE START
SAVE
BAT CELL mV
C
28
BATT
MODE
TYPE
CELL
CURRENT
TVC
save
SAVE
BAL CHG
BATT
MODE
TYPE
SAVE
MV
RimΩ
4
7
5
4
2
1
STOP
V10
O 24
00
AC CUR
C TVC
10 00
MV
PRESENT SETTING
START
BACK
START
BACK
START
BACK
START
BACK
START
LIIO
CHARGE
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 24
00 STOP
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
LIIO
FAST CHG
6 S
A
10 00
MV
CHARGING
LIIO
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 24
00 STOP
FAST CHG
LIIO
STORAGE
6 S
A
5 00
MV
CELLS
C CUR
C TVC
MODE DISCHARGE
6 S
A
5 00
2500 MV
CELLS
D CUR
D TVC
LIIO
STORAGE
6S
A691
V60
I 12
MAH158
3812
C6 4038 20
C5 4035 17
C4 4030 12
C3 4025 7
C2 4020 2
C1 4018 0
BAT CELL mV
C
28
RimΩ
STOP
V10
O 24
00
LIIO
STORAGE
6S
A691
V60
I 12
MAH158
3812
C
28
V10
O 24
00
BATT
MODE
TYPE LIIO
CYCLE
6 S
A
10 00
MV
CELLS
C CUR
C TVC
A
5 00
D CUR
SAVE BACK
START
PRESENT SETTING
2500 MV
D TVC
CD
SEQUENCE
10 MIN
W TIME
1
TIMES
LIIO
6S
A691
V60
I 12
MAH1958
3812
C6 3538 20
C5 3535 17
C4 3530 12
C3 3525 7
C2 3520 2
C1 3518 0
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V10
O 24
00
CYCLE
DISCHARGING
STOP
CYCLE
BAL CHG
4100
4100
4100
3750
LIPO
BAL CHG
AUTO
A0010
MV4200
STANDBY
Monitor Start
Sys Load Menu
C

19 20
Only in Cycle mode, select the charge/discharge sequence.
C D: charge to discharge
D C: discharge to charge
Only in Cycle mode, set the waste time between charge/discharge. Range from 0-60
minutes, change unit 1 .
Only in Cycle mode, set the times of charge/discharge cycle. Range from 1-9 times, change
unit 1 .
SEQUENCE
Save the current setting to 1st-9th memory.
Connect the battery, press start, charger will work under present setting.
Back to “STANDBY” menu.
SAVE
W-TIME
TIMES
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Battery cells
Cell voltage
Cell voltage difference
Balance Charge
External temperature
Working stutus
Input Voltage
Charge
Fast Charge
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Storage
External temperature
Input Voltage
Cell internal resistance
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Discharge
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Cycle
External temperature
Input Voltage
Battery cells
Cell voltage
Cell voltage difference
Cell internal resistance
Work finshed
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
LIIO
6S
A691
V60
I 12
MAH1958
3812
C6 4038 20
C5 4035 17
C4 4030 12
C3 4025 7
C2 4020 2
C1 4018 0
CHARGING
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V10
O 24
00
LIIO
CHARGE
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 24
00 STOP
CHARGING
LIIO
6S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 24
00 STOP
FAST CHG
LIIO
STORAGE
6S
A691
V60
I 12
MAH158
3812
C6 4038 20
C5 4035 17
C4 4030 12
C3 4025 7
C2 4020 2
C1 4018 0
BAT CELL mV
C
28
RimΩ
STOP
V10
O 24
00
LIIO
DISCHARGE
6S
A691
V60
I 12
MAH158
3812
C
28
V10
O 24
00
LIIO
CYCLE
6S
A691
V60
I 12
MAH1958
3812
C6 4038 20
C5 4035 17
C4 4030 12
C3 4025 7
C2 4020 2
C1 4018 0
BAT CELL mV
C
28
RimΩ
4
7
5
4
2
1
STOP
V10
O 24
00
DISCHARGING
STOP
BAL CHG
FINISHED
LILO
6S
A690
V60
I 12
MAH2058
3820
C
28
V50
O 24
00 ENTER
BAL CHG
FINISHED
LILO
6S
A690
V60
I 12
MAH2058
3818
C
28
V50
O 24
00 ENTER
FINISHED
LILO
6S
A690
V60
I 12
MAH2058
3816
C
28
V50
O 24
00 ENTER
FINISHED
LILO
6S
A690
V60
I 12
MAH958
3850
C
28
V50
O 22
00 ENTER
CHARGE
FAST CHG
STORAGE
FINISHED
LILO
6S
A690
V60
I 12
MAH1958
3820
C
28
V10
O 17
01 ENTER
DISCHARGE
FINISHED
LILO
6S
A690
V60
I 12
MAH2058
3830
C
28
V10
O 17
02 ENTER
CYCLE

21 22
CHARGE/DISCHARGE NIMH BATTERY
*Select: turn left/right
*Enter/Set/Stop: press
Select the cell count of the battery, range from 1-15 .
Important note: The cell count you sellect must be exact the same as your battery,
otherwise may cause dangerous situation.
Select the max charge/discharge current.
Range from 0.1-20.0, change unit: 0.1-20.0
C-CUR: Charge current
Range from 0.1-20.0, change unit: 0.1-20.0
D-CUR: Discharge current
Terminal Voltage Control.
Range from 800-1200, change unit: 10, default: 1000
D-TVC: TVC of Discharge
Parameter setting Working stutus
NIMH
AUTO_CHG: Auto Charge, the charger will automatically charge the battery according to
the situation of the battery, current will be adjust by the charger but never over the setting.
MANU_CHG: Manual Charge, the charger will charge the battery by the setting current.
CYCLE: Charge and discharge
DISCHARGE: Discharge
Only in Cycle mode, select the charge/discharge sequence.
C D: charge to discharge
D C: discharge to charge
Only in Cycle mode, set the waste time between charge/discharge. Range from 0-60
minutes, change unit 1 .
Only in Cycle mode, set the times of charge/discharge cycle. Range from 1-9 times, change
unit 1 .
SEQUENCE
Save the current setting to 1st-9th memory.
Connect the battery, press start, charger will work under present setting.
Back to “STANDBY” menu.
SAVE
W-TIME
TIMES
BATT
MODE
TYPE
BACK
NIMH
AUTO CHG
BATT TYPE NIMH
CHARGING
SAVE START
SAVE
SAVE
BATT
MODE
TYPE
SAVE
AC CUR 10 00
PRESENT SETTING
BACK
START
BACK
START
BACK
START
NIMH
15S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
NIMH
MANU CHG
A
00 CHARGING
NIMH
A691
V60
I 12
MAH1958
3812
c
28
V10
O 23
00 STOP
C CUR
MODE DISCHARGE
A
5 00
1000 MV
CELLs
D CUR
D TVC
NIMH
DISCHARGE
A691
V60
I 12
MAH158
3812
C
28
V10
O 23
00
BATT
MODE
TYPE NIMH
CYCLE
A
10 00
CELLS
C CUR
A
5 00
D CUR
SAVE BACK
START
PRESENT SETTING
D TVC
CD
10 MIN
W TIME
1
TIMES
CYCLE
DISCHARGING
STOP
15 S
15 S
10
1000 MV
CHARGING
NIMH
CYCLE
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
SEQUENCE
15S
15S
15S
AUTO CHG
MA N U CHG
LIPO
BAL CHG
AUTO
A0010
MV4200
STANDBY
Monitor Start
Sys Load Menu
C

23 24
Auto_Charge
Manu_Charge
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Discharge
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Cycle
External temperature
Input Voltage
Working stutus
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
Work finshed
CHARGE/DISCHARGE NICD BATTERY
*Select: turn left/right
*Enter/Set/Stop: press
Parameter setting Working stutus
NICD
AUTO_CHG: Auto Charge, the charger will automatically charge the battery according to
the situation of the battery, current will be adjust by the charger but never over the setting.
MANU_CHG: Manual Charge, the charger will charge the battery by the setting current.
CYCLE: Charge and discharge
DISCHARGE: Discharge
CHARGING
NIMH
15S
A691
V60
I 12
MAH1958
3812
C
28
V10
o 23
00 STOP
CHARGING
A691
V60
I 12
MAH1958
3812
C
28
V10
o 23
00 STOP
MANU CHG
DISCHARGE
A691
V60
I 12
MAH158
3812
C
28
V10
O 23
00
DISCHARGING
STOP
CHARGING
CYCLE
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
FINISHED
A690
V60
I 12
MAH2058
3818
C
28
V20
O 24
00 ENTER
FINISHED
A690
V60
I 12
MAH2058
3816
C
28
V20
O 24
00 enter
MANU CHG
FINISHED
A690
V60
I 12
MAH1958
3820
C
28
V10
O 16
01 ENTER
DISCHARGE
FINISHED
A690
V60
I 12
MAH2058
3830
C
28
V10
O 16
02 ENTER
CYCLE
NIMH
15S
NIMH
15S
NIMH
15S
NIMH
15S
NIMH
15S
NIMH
15S
NIMH
15S
AUTO CHG AUTO CHG BATT
MODE
TYPE
BACK
NICD
AUTO CHG
BATT TYPE NICD
CHARGING
SAVE START
SAVE
SAVE
BATT
MODE
TYPE
SAVE
AC CUR 10 00
PRESENT SETTING
BACK
START
BACK
START
BACK
START
NICD
15S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
NICD
MANU CHG
A
00 CHARGING
NICD
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
C CUR
MODE DISCHARGE
A
5 00
1000 MV
CELLS
D CUR
D TVC
Nicd
DISCHARGE
A691
V60
I 12
MAH158
3812
C
28
V10
O 23
00
BATT
MODE
TYPE NICD
CYCLE
A
10 00
CELLs
C CUR
A
5 00
D CUR
SAVE BACK
START
PRESENT SETTING
D TVC
CD
10 MIN
W TIME
1
TIMES
CYCLE
DISCHARGING
STOP
15 S
15 S
10
1000 MV
CHARGING
NICD
CYCLE
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
SEQUENCE
15S
15S
15S
AUTO CHG
MANU CHG
LIPO
BAL CHG
AUTO
A0010
MV4200
STANDBY
Monitor Start
Sys Load Menu
C

25 26
Select the cell count of the battery, range from 1-15 .
Important note: The cell count you sellect must be exact the same as your battery,
otherwise may cause dangerous situation.
Select the max charge/discharge current.
Range from 0.1-20.0, change unit: 0.1-20.0
C-CUR: Charge current
Range from 0.1-20.0, change unit: 0.1-20.0
D-CUR: Discharge current
Terminal Voltage Control.
Range from 650-1050, change unit: 10, default: 850
D-TVC: TVC of Discharge
Only in Cycle mode, select the charge/discharge sequence.
C D: charge to discharge
D C: discharge to charge
Only in Cycle mode, set the waste time between charge/discharge. Range from 0-60
minutes, change unit 1 .
Only in Cycle mode, set the times of charge/discharge cycle. Range from 1-9 times, change
unit 1 .
SEQUENCE
Save the current setting to 1st-9th memory.
Connect the battery, press start, charger will work under present setting.
Back to “STANDBY” menu.
SAVE
W-TIME
TIMES
Auto_Charge
Manu_Charge
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Discharge
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Cycle
External temperature
Input Voltage
Working stutus
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
Work finshed
charging
NICD
15S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
CHARGING
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
MANU CHG
DISCHARGE
A691
V60
I 12
MAH158
3812
C
28
V10
O 23
00
DISCHARGING
STOP
CHARGING
CYCLE
A691
V60
I 12
MAH1958
3812
C
28
V10
O 23
00 STOP
FINISHED
A690
V60
I 12
MAH2058
3818
C
28
V20
O 24
00 ENTER
FINISHED
A690
V60
I 12
MAH2058
3816
C
28
V20
O 24
00 ENTER
MANU CHG
FINISHED
A690
V60
I 12
MAH1958
3820
C
28
V80
O 13
01 ENTER
DISCHARGE
FINISHED
A690
V60
I 12
MAH2058
3830
C
28
V80
O 13
02 ENTER
CYCLE
NICD
15S
NICD
15S
NICD
15S
NICD
15S
NICD
15S
NICD
15S
NICD
15S
AUTO CHG AUTO CHG

27 28
CHARGE/DISCHARGE PB BATTERY
*Select: turn left/right
*Enter/Set/Stop: press
Select the max charge/discharge current.
Range from 0.1-20.0, change unit: 0.1-20.0
C-CUR: Charge current
Range from 0.1-20.0, change unit: 0.1-20.0
D-CUR: Discharge current
Terminal Voltage Control.
Range from 1550-1950, change unit: 10, default: 1750
C-TVC: TVC of Charge
Range from 2300-2450, change unit: 10, default: 2400
D-TVC: TVC of Discharge
Parameter setting Working stutus
PB: (Lead-acid battery)
CHARGE: Charge
CYCLE: Charge and discharge
DISCHARGE: Discharge
Only in Cycle mode, select the charge/discharge sequence.
C D: charge to discharge
D C: discharge to charge
Only in Cycle mode, set the waste time between charge/discharge. Range from 0-60
minutes, change unit 1 .
Only in Cycle mode, set the times of charge/discharge cycle. Range from 1-9 times, change
unit 1 .
SEQUENCE
Save the current setting to 1st-9th memory.
Connect the battery, press start, charger will work under present setting.
Back to “STANDBY” menu.
SAVE
W-TIME
TIMES
Select the cell count of the battery, range from 1-10 .
Important note: The cell count you sellect must be exact the same as your battery,
otherwise may cause dangerous situation.
BATT TYPE PB
SAVE
SAVE
BATT
MODE
TYPE
SAVE BACK
START
BACK
START
BACK
START
PRESENT SETTING
PRESENT SETTING
PRESENT SETTING
PB
CHARGE
A
00
CHARGING
PB
A691
V60
I 12
MAH1958
3812
C
28
V10
O 22
00 STOP
C CUR
MODE DISCHARGE
A
5 00
1750 MV
CELLS
D CUR
D TVC
PB
DISCHARGE
A691
V60
I 12
MAH158
3812
C
28
V10
O 22
00
BATT
MODE
TYPE PB
CYCLE
A
10 00
CELLS
C CUR
A
5 00
D CUR
SAVE BACK
START
PRESENT SETTING
D TVC
CYCLE
DISCHARGING
STOP
10 S
10 S
10
2400 MV
CHARGING
PB
CYCLE
A691
V60
I 12
MAH1958
3812
C
28
V10
O 22
00 STOP
10S
10S
10S
MANU CHG
CELLS 10 S
2400 MV
C TVC
1750 MV
D TVC
CD
SEQUENCE
10 MIN
W TIME
1
TIMES
LIPO
BAL CHG
AUTO
A0010
MV4200
STANDBY
Monitor Start
Sys Load Menu
C

29 30
Charge
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
External temperature
Input Voltage
Battery and Cells
Working Mode
Discharge/ current
Output(battery) Voltage
Discharged capacity
Timer
Discharge
External temperature
Input Voltage
Battery and Cells
Working Mode
Charge current
Output(battery) Voltage
Charged capacity
Timer
Cycle
External temperature
Input Voltage
Working stutus
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
*Display stop along with “Bi...Bi...” sound
Work finshed
Note:
1, Press “START” or during working, if input voltage is higher than 30.0V, charger will
display “HIGHER INPUT VOLTAGE” along with
.0V, charger will display “HIGHER INPUT VOLTAGE” along with
4, If battery’s total voltage is lower than the discharge cutoff level, charger will display
“LOWER TOTAL VOLTAGE”
6,
7,Disconnect the charge cable during working status, charger will display “CONNECTION
ERROR” along with “Bi...Bi...Bi...” sound.
8, In “BALCHARGE” mode, disconnect the balance connector, charger will display
“BALANCE ERROR”
, In “DISCHARGE” and “STORAGE” mode,
Remark:
1, Once the charger report error, press “ENTER” to return “STANDBY” Menu.
2,Screen diagram shows in this manual only for reference, and will be different in each use.
“Bi...Bi...Bi...” sound.
“Bi...Bi...Bi...” sound.
2, Press “START” or during working, if input voltage is lower than 11.0V, charger will display
“LOWER INPUT VOLTAGE” along with “Bi...Bi...Bi...” sound.
3, If output connection reverse, charger will display “REVERSE OUTPUT” along with
“Bi...Bi...Bi...” sound.
along with “Bi...Bi...Bi...” sound.
5, If battery’s cell voltage is lower than the discharge cutoff level, charger will display
“LOWER CELL VOLTAGE” along with “Bi...Bi...Bi...” sound.
If battery detected by the charger is different from your setting, charger MAY display
“BATTERY ERROR” along with “Bi...Bi...Bi...” sound.
along with “Bi...Bi...Bi...” sound.
9 plug in balance connector, charger will display
cell voltage. Disconnect the balance connector, charger will display “BALANCE ERROR”
along with “Bi...Bi...Bi...” sound.
NOTES OF WORK STATUS
CHARGING
PB
10S
A691
V60
I 12
MAH1958
3812
C
28
V10
O 22
00 STOP
DISCHARGE
A691
V60
I 12
MAH158
3812
C
28
V10
O 22
00
DISCHARGING
STOP
CHARGING
CYCLE
A691
V60
I 12
MAH1958
3812
C
28
V10
O 22
00 STOP
FINISHED
A690
V60
I 12
MAH2058
3818
C
28
V90
O 23
00 ENTER
FINISHED
A690
V60
I 12
MAH1958
3820
C
28
V80
O 17
01 ENTER
DISCHARGE
FINISHED
A690
V60
I 12
MAH2058
3830
C
28
V80
O 17
02 ENTER
CYCLE
PB
10S
PB
10S
PB
10S
PB
10S
PB
10S
CHARGE AUTO CHG

MONITOR
You can charge and balance several Lithium batteries at the same time, by
using optional Series Adaptor or Parallel Adapter. Please note that the
battery packs being charged should have the close voltage, the same
capacity and cell-count.
31 32
BATTERY IN SERIES/PARALLEL CHARGE
Choose and enter “Monitor”, the charger will monitoring the status of the
voltage of the power supply, total/cell voltage of the battery.
Total voltage of battery
External temperature
Voltage of power supply
Battery cells
Cell voltage
Cell voltage difference
Note: press “AGAIN” charger will monitor the status again, press “BACK”,
back to “STANDBY” menu.
A1024
V60
12
TEMP
C6 4038 20
C5 4035 17
C4 4030 12
C3 4025 7
C2 4020 2
C1 4018 0
MONITOR
C
28
BACK
VPOWER
VBATT
AGAIN

CONFORMITY DECLARATION
This symbol means that you must dispose of electrical devices from the general household waste when it
reaches the end of its useful life. Take your charger to your local waste collection point or recycling centre.
This applies to all countries of the European Union, and to other European countries with a separate waste
collection system.
33 34
WARRANTY
CASALRC provide a period of one year product warranty from the date
of purchase. The warranty only applies to material or operational defects,
which are present at the time of purchase.
During that period, we will repair or replace free of service charge for
products deemed defective due to those causes. This warranty is not valid
for any damage or subsequent damage arising as a result of misuse,
modification or as a result of failure to observe the use guideline in this
manual.
C8G
LIABILITY EXCLUSION
CASALRC is designed and approved exclusively for charge the types of
battery stated in this manual. CASALRC do not accept any liability if the
charger is used for any purpose other than that stated. We are unable to
ensure you follow the instructions come with the charger, and we have no
control over the methods you employ for using, operating and maintaining
this device. For this reason we are obliged to deny the liability for loss,
damage or costs which are incurred due to the incompetent or incorrect use
and operation of this product, or which are connected with such operation in
any way. Unless otherwise prescribed by law, our obligation to pay
compensation, regardless of the legal argument employed, is limited to
the invoice value of those CASALRC products which were immediately
and directly involved in the event in which the damage occurred.
C8G
Application Test Standard
Title Result
CE-LVD EN60335 For safety of household and similar electrical
appliances. Conform
EN55014-1:2006
Electromagnetic compatibility-Requirements
for household appliances,electric tools and
Similar apparaturs - Part 1: Emission
Conform
EN55014-2:1997 +A1:2001
Electromagnetic compatibility-Requirements
for household appliances,electric tools and
Similar apparaturs - Part 2: Immunity-Product
family standard
Conform
EN61000-6-1(2007)
Electromagnetic compatibility (EMC) -- Part 6-1:
Generic standards - Immunity for residential,
commercial and light-industrial environments.
Conform
EN61000-6-3(2007)
Electromagnetic compatibility (EMC) -- Part
6-3: Genericstandards - Emission standard
for residential, commercial andlight-industrial
environments.
Conform
FCC-VOC FCC Part 15B Electromagnetic compatibility (EMC),
Conduction Emission & Radiation Emission Conform
AM8G satisfies all relevant and mandatory EC directives and FCC Part 15 Subpart B: 2008.
The product has been tested to meet the following technical standards:
CE-EMC
This manual suits for next models
1
Table of contents
Other Amewi Batteries Charger manuals