manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. AMX
  6. •
  7. Control Unit
  8. •
  9. AMX RDM-HFDB Assembly instructions

AMX RDM-HFDB Assembly instructions

This manual suits for next models

1

Other AMX Control Unit manuals

AMX DG RGBHV MTP User manual

AMX

AMX DG RGBHV MTP User manual

AMX RDA-CKM Quick start guide

AMX

AMX RDA-CKM Quick start guide

AMX HPX-AV102-RGB+A-R User manual

AMX

AMX HPX-AV102-RGB+A-R User manual

AMX DCE-1 User manual

AMX

AMX DCE-1 User manual

AMX PLB-CF2 User manual

AMX

AMX PLB-CF2 User manual

AMX MAX-AOM User manual

AMX

AMX MAX-AOM User manual

AMX RDM-DPSM Guide

AMX

AMX RDM-DPSM Guide

AMX RDM-DC Quick start guide

AMX

AMX RDM-DC Quick start guide

AMX AXU-MSP8 User manual

AMX

AMX AXU-MSP8 User manual

AMX RDM-HDC Manual

AMX

AMX RDM-HDC Manual

AMX RMX 16 User manual

AMX

AMX RMX 16 User manual

AMX SD-2 Quick start guide

AMX

AMX SD-2 Quick start guide

AMX Encore User manual

AMX

AMX Encore User manual

AMX RDM-HSW Quick start guide

AMX

AMX RDM-HSW Quick start guide

AMX AXB-DTMF Plus User manual

AMX

AMX AXB-DTMF Plus User manual

AMX NXS-NMS User manual

AMX

AMX NXS-NMS User manual

AMX CAT-5 RGBHV RX User manual

AMX

AMX CAT-5 RGBHV RX User manual

AMX HPX-1600 User manual

AMX

AMX HPX-1600 User manual

AMX RDM-DC Quick start guide

AMX

AMX RDM-DC Quick start guide

AMX HPX-U100-BTN User manual

AMX

AMX HPX-U100-BTN User manual

AMX DG DVI MTP User manual

AMX

AMX DG DVI MTP User manual

AMX HPX-AV101-DP-R User manual

AMX

AMX HPX-AV101-DP-R User manual

AMX 8450-03 User manual

AMX

AMX 8450-03 User manual

AMX CTC-1402 User manual

AMX

AMX CTC-1402 User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation Sheet
RDM-HFDB Heavy Duty FDB Module
2400 W
The RDM-HFDB Heavy Duty FDB Module is a heavy-duty, 2400 W positive
air gap relay and dimmer, built for strength and for reliable switching/dim-
ming of Lutron FDB ballasts. It is designed for use with the RDA series of
enclosures, in a AMX Lighting™ modular digital dimming system. The
RDM-HFDB module's 120, 240, and 277 VAC ratings are CE, UL, and C-UL
approved.
RDM-HFDB UL and C-UL Ratings
• 120 VAC, 2400 W
• 240/277 VAC, 2400 W
Suggested Dimmed Loads
• Lutron©FDB Ballasts
• Lutron ECO-10®Ballasts (refer to the AMX Lighting instruction manual
for more information)
Specifications:
• Dimensions (HW): 10.0" x 2.75" (25.4 cm x 6.99 cm)
• Phase dependant
• Use wires rated at 75°C (167°F)
• Torque terminals to 20 in-lbs. (2.3 N/M)
• Max. wire size: 10 AWG (4 mm²)
• Wire stripping length: 0.28" (7 mm)
• Weight: 1.50 lbs. (0.680 kg)
• BTU/hr: 150
• Control current: 135 mA @ 12 VDC
• Use Dimming Curve 6 (refer to the Programming AMX Lighting
instruction manual for more information).
• For use with FDB ballasts.
Caution: Pre-Installation Notes
• All Class 1 wiring must be connected to proper terminals.
• All control wiring must be connected to proper terminals.
• Disconnect power while installing or connecting the unit.
• Keep top and bottom air vents clear at all times.
• Test loads for shorts before connecting. Use low-voltage wires with a
300 volt rating or greater.
• Use field installed copper conductors.
• All electrical ratings are for continuous duty.
• For indoor use only.
• This module may require extra power from the AXlink connection or an
external power supply connected to the control card.
Connecting the RDM-HFDB to the AMX Lighting Master
Lighting Application Drawings
FIG. 1 RDM-HFDB
Low-voltage control
wiring: 4-pin connector
to AMX Lighting master
controller
Solid state relay
Positive air
gap relay
Switched out
Dimmed out
Neutral
Line in (hot)
High
voltage
connections
Mounting points
High
voltage
connections
FIG. 2 Connecting the RDM-HFDB and AMX Lighting Master
FIG. 3 RDM-HDC application wiring
Pin 3 (RLY)
Pin 2 (DIM)
Pin 1 (+12 V)
RDM-HFDB 4-pin module connector
1 (+)
2 (AC)
3 (-)
4-pin plug from RDM series module
Note: The 4-pin plugs from the module connector to the 4-pin
connector on the master (black plug cover facing up).
Ballast
Florescent Ballast
Circuit breaker
panel
RDM-HFDB
NEUTRAL LINE SWITCHED DIMMED
Switched
Dimmed
Neutral
Line in (HOT)
All neutrals are common
to the Neutral block in
the enclosure. Provide
a separate neutral for each
Neutral load.
AMX Corporation reserves the right to alter specifications without notice at any time.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
043-019-2239 10/01 ©2001 AMX Corporation. All rights reserved.
The AMX logo is a trademark of AMX Corporation. AMX Corporation reserves the right to alter specifications without notice at any time.
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993