HOUSING OUTLET
MODEL A710 DEHUMIDIFIER
HOUSING INLET
SCREWS x40
SEALING PLUGS x3
FILTER ACESS DOOR
THUMB SCREWS x2
24" INLET RING x2
CAUTION
Sharp edges may cause serious injury from cuts. Use care when
cutting plenum openings and handling duct work.
NOTICE
• Failure to follow ducting guidelines may negatively impact unit
performance.
• Minimize equivalent duct length to maximize unit capacity and
efficiency.
Part #5859 Round Duct Kit
for Model A710 Dehumidifier
Installation Instructions
TABLE OF CONTENTS
Airflow Delivery Specifications ....................................1
Ducting Sizing and Routing .......................................2
Duct Kit Installation ..............................................3
Replacing the Filter ..............................................4
Overall Dimensions ..............................................4
AIRFLOW DELIVERY SPECIFICATIONS
• Nominal airflow through dehumidifier is 1760 cfm.
• Airflow decreases as duct length and bends increase, therefore if
the equivalent duct length is too long the dehumidifier will cease to
function properly.
90-2578
1
DUCT SIZING AND ROUTING
• Inlet and outlet collars fit 24" round duct.
• Unit performance decreases as airflow decreases, the shortest
possible duct lengths with minimal bends should be used.
• Do not exceed 1,000 feet of metal duct or 750 feet of flex duct.
EQUIVALENT LENGTH OF BENDS
45° bend 5 feet
90° bend 10 feet
180° bend 30 feet
• Max static pressure is 0.6" w.c.
• Install the dehumidifier in location where filter door, service access
panel, compressor side panel, and user interface are accessible, see
the Dehumidifier Installation and Operating Instructions for more
details.
• Do not install a bend in the ductwork within 2 feet of the
dehumidifier inlet or outlet.
• When selecting duct material, it is preferred to use metal ducting to
maintain airflow. If flex duct is to be used, ensure it is extended out
as much as possible to limit disruptions to the airflow. NOTE:Use
only insulated ducting when the inlet side of the duct work is
located outside of the conditioned space. In some instances when
the dehumidifier is placed outside of the conditioned space, the
cabinet of the dehumidifier may also need to be insulated to prevent
condensation formation on the exterior of the unit.
• Do not duct more than one dehumidifier together.
90-2579
• If using registers and diffusers, the total open area must be at least
453 in2, which is the equivalent area to a 24 inch round.
• When locating registers and diffusers be aware of the following;
– Relative to plants – do not directly vent onto plants.
– Relative to other dehumidifier inlets/outlets – must be a minimum
10 feet apart and do not direct toward one another.
– Relative to HVAC diffusers – ensure minimum 10 foot distance
from other HVAC diffusers.
• Ensure that the ductwork is supported within 2 feet of inlet and
outlet of the dehumidifier. Consult building codes and standards for
duct support requirements beyond 2 feet of the dehumidifier.
2
ALIGNMENT TABS x4
REMOVE 6 CLIPS
SEALING PLUGS
DUCT KIT INSTALLATION
90-2582
90-2583
90-2584
STEP 2
Attach the assembled duct housing to the dehumidifier using screws provided.
Additional holes will need to be made in the cabinet where holes did not
previously exist. To properly seal the unit, use a 5/32" bit to pre-drill
holes and use the screws provided. If you choose to use self drilling
screws, make sure they are no longer than 1". To secure the
3screws on the left side of the duct kit (opposite the filter
access door), a bit extension of at least 6" is required.
After securing all screws, insert the sealing plugs provided
into the access holes on the left hand side.
STEP 3
Install the filter access door and secure with
the two thumb screws.
STEP 1
On each housing, bend the four alignment tabs so they are protruding out of the front of
as shown below. These are to be used as alignment features for the 24" collar.
3
anden.com
P.O. Box 1467
Madison, WI 53701-1467
800.972.3710 F: 608.257.4357
Printed in USA
©2020 Anden – A Quality brand from Research Products Corporation
10015226 B2209114A 12.20
OVERALL DIMENSIONS (INCHES)
54.70
43.20
44.86
(ø 23.75)
TOP VIEW SIDE VIEW
16.69
17.22
34.36
REPLACING THE FILTER
1. Loosen the two thumb screws and remove the filter access door.
2. Pull the filter away from the unit, then out through the access opening.
3. Install the new filter in the same direction.
4. Reinstall the filter access door and tighten the thumb screws.
90-2580

Other Anden Dehumidifier manuals

Anden A320V1 User manual

Anden

Anden A320V1 User manual

Anden A95F User manual

Anden

Anden A95F User manual

Anden A710V1 User manual

Anden

Anden A710V1 User manual

Anden A200V1 User manual

Anden

Anden A200V1 User manual

Anden A100 User manual

Anden

Anden A100 User manual

Anden A320V1 User manual

Anden

Anden A320V1 User manual

Anden A130 User manual

Anden

Anden A130 User manual

Anden A130F User manual

Anden

Anden A130F User manual

Anden SURNA S320V1 User manual

Anden

Anden SURNA S320V1 User manual

Anden A210V1 User manual

Anden

Anden A210V1 User manual

Anden A320V1 User manual

Anden

Anden A320V1 User manual

Anden Surna S210V1 User manual

Anden

Anden Surna S210V1 User manual

Anden A210V1 User manual

Anden

Anden A210V1 User manual

Anden A100F User manual

Anden

Anden A100F User manual

Anden A210V1 User manual

Anden

Anden A210V1 User manual

Anden A710V1/V3 User manual

Anden

Anden A710V1/V3 User manual

Anden Surna S210V1 User manual

Anden

Anden Surna S210V1 User manual

Popular Dehumidifier manuals by other brands

RDZ DA 1000 Installation, use and maintenance

RDZ

RDZ DA 1000 Installation, use and maintenance

Uni-P Dry Pro 200X Installation, operation & service instructions

Uni-P Dry

Uni-P Dry Pro 200X Installation, operation & service instructions

ARDES AR8D17 Instructions for use

ARDES

ARDES AR8D17 Instructions for use

INVENTOR DE-GDNM16 owner's manual

INVENTOR

INVENTOR DE-GDNM16 owner's manual

Rowenta VITALITY DH3110 Instructions for use

Rowenta

Rowenta VITALITY DH3110 Instructions for use

Ivation IVA20PDEHU user guide

Ivation

Ivation IVA20PDEHU user guide

HTW X11 Owners and installation manual

HTW

HTW X11 Owners and installation manual

Goldstar GD300S owner's manual

Goldstar

Goldstar GD300S owner's manual

Pingi Dry Again C-350M operating instructions

Pingi

Pingi Dry Again C-350M operating instructions

Comedes Demecto 70 manual

Comedes

Comedes Demecto 70 manual

SMC Corporation IDG5*V4-***-*-X032 Series Operation manual

SMC Corporation

SMC Corporation IDG5*V4-***-*-X032 Series Operation manual

Dantherm Calorex DH334BH Technical installation manual

Dantherm

Dantherm Calorex DH334BH Technical installation manual

Suntec Wellness Klimatronic DryFix 10 Pure manual

Suntec Wellness

Suntec Wellness Klimatronic DryFix 10 Pure manual

Living & Co DYD-S10A412 instruction manual

Living & Co

Living & Co DYD-S10A412 instruction manual

YANGZI CS10Z manual

YANGZI

YANGZI CS10Z manual

Ingersoll-Rand EHD Series Operator's instruction manual

Ingersoll-Rand

Ingersoll-Rand EHD Series Operator's instruction manual

Goldair GD160 operating instructions

Goldair

Goldair GD160 operating instructions

Mycond ABS 7A Installation instructions manual

Mycond

Mycond ABS 7A Installation instructions manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.