6. Warranty and After Sales Service
(1)AP-DC2451 ionizing air blowers are strictly inspected before
ex-work and match all the related technical standard indicated in
this manual.
(2)AP&T PROMISE:Repair or change any damaged parts caused by
quality reasons free of charge within one year from the date of
purchase after we confirm the quality issue.
(3)Above promise is not fit for the following situation:
Alternation of the device, wrongly used, incorrect installation,
abasement, negligence, accidental damage, wrong input voltage,
unpacking and repacking by user itself or maintain by other
unauthorized service department.
(4)AP&T is free from any related responsibility of using the product
except the parts specified here above.
7. Caution:
(1)In order to guarantee the blower to work with good technical
feature, user should clear the sediment on electrode sharp slightly
with brush pen every 5-7 days under normal operation.
A. Must be done 10 minutes affer power switched off.
B. Alloy electrode is consumable without warranty,and cost is chargable when
change.
(2)User should not over turn the air volume adjust knob.Permanent Damage
caured by this operation will be beard by the operator.
1. General
AP-DC2451 ionizing air blower is a member of the ionizing blower
product series manufactured by Shanghai Anping Static Technology
Co.,Ltd, which is a reliable and high efficient device in providing
static removing for the objective surface.
AP-DC2451 applies the latest technology of ionization model in the
world. It generate both polarity ion and arrive the object surface
where the static to be eliminated most equally. Eliminate static
effectively and control the remaining static well.
AP-DC2451 is widely used in electronics、plastic、chemical、printing
and optics industry etc.
2. Features
(1)Big volume of ion generating and fast speed of static removing.
(2)Applies commutating, filtrating circuit with low voltage and high
reliability.
(3)Front and back cover net unloadable and easy for maintenance.
(4)DC working voltage with low power consumption and long
product life.
(5)Internal power generator.
AP&T
AP-DC2451
3. Specification
Model AP-DC2451
Input voltage AC 220V/50HZ or 110V/60HZ
Power 12W
Ion balancing ≤|±10V|(300mm from blower)
Discharge time ≤2s (300mm from blower)
Effective scope 600×1200mm
Air volume(Adjustable) 0~95 CFM
Noise ≤45db (150mm from air outlet)
Ozone thickness ≤0.02 ppm (150mm from air outlet)
Working temperature 0°C - 50°C
Weight 1520g
Dimension 196×180×64(mm)
4. Installation
When using AP-DC2451 ionizing air blower,the air transmitter
should be vertical to the object which static to be removed. The
trestle should be fixed on stable and plain surface such as wall by
screw and nut.
AP-DC2451 ionizing air blower should be put near working area
or 300~900mm to the objective. By screw the knob on both side
of the trestle the horizontal angle can be adjusted so that the
optimal effect of static removing can be achieved.
Installation instruction:
(1)Insert the power cord to the
power socket at the back
side of the blower.
(2)Switch on the power.
(3)Turn the air volume control
knob to proper value to
reach optimal effect.
Positioning
Desktop vertical suspended Oblique suspended Table clamping
5. Safety
(1) Be aware to read this user manual carefully before install and use
this device.
(2)Do not locate this device in the environment with high moisture.
(3)Do not insert any object into air input entry and output exit.
(4)Do not use this device in the flammable and explosive
surrounding.
(5)Internal maintenance and repairing must be done by professional
engineers.

Other AP&T Air Ionizer manuals

AP&T AP-AZ3201 User manual

AP&T

AP&T AP-AZ3201 User manual

AP&T AP-DJ283 Series User manual

AP&T

AP&T AP-DJ283 Series User manual

Popular Air Ionizer manuals by other brands

Vessel Stat-Clean C-90 instruction manual

Vessel

Vessel Stat-Clean C-90 instruction manual

SMC Networks IZT43-L Series Operation manual

SMC Networks

SMC Networks IZT43-L Series Operation manual

GPS iRIB-18 Start-Up Checklist

GPS

GPS iRIB-18 Start-Up Checklist

Bionizer Spa Star Instruction book

Bionizer

Bionizer Spa Star Instruction book

bossauto IONIZER pro user manual

bossauto

bossauto IONIZER pro user manual

Sanixair BreatheMe Use and maintenance

Sanixair

Sanixair BreatheMe Use and maintenance

AlkaViva Vesta H2 Quick start quide

AlkaViva

AlkaViva Vesta H2 Quick start quide

Omron ZN-J25A instruction sheet

Omron

Omron ZN-J25A instruction sheet

Shishido Electrostatic CABX350 manual

Shishido Electrostatic

Shishido Electrostatic CABX350 manual

UFO UFO-MCH/15 user manual

UFO

UFO UFO-MCH/15 user manual

Koganei DTY-ELG31 owner's manual

Koganei

Koganei DTY-ELG31 owner's manual

Real Spirit AQUA-IONIZER PRO ionHealth Pro owner's manual

Real Spirit

Real Spirit AQUA-IONIZER PRO ionHealth Pro owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.