manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. APG
  6. •
  7. Accessories
  8. •
  9. APG LPU-2127 User manual

APG LPU-2127 User manual

LPU-2127 Loop Powered Ultrasonic Sensor
Installation Guide
For LPU-2127
R
APG
Automation Products Group, Inc.
1025 W 1700 N Logan, UT 84321
www.apgsensors.com | phone: 888-525-7300 | email: [email protected]
Thank You
Thanks for purchasing an LPU-2127 loop powered ultrasonic level sensor from us! We appreciate
your business and your trust. Please take a moment to familiarize yourself with the product and this
manual before installation. If you have any questions, at any time, don’t hesitate to call us at 888-
525-7300.
APG warrants its products to be free from defects of material and workmanship and will, without
charge, replace or repair any equipment found defective upon inspection at its factory, provided
the equipment has been returned, transportation prepaid, within 24 months from date of shipment
from factory.
THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT
EXPRESSLY SET FORTH HEREIN, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR
OTHERWISE INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.
No representation or warranty, express or implied, made by any sales representative, distributor,
or other agent or representative of APG which is not specically set forth herein shall be binding
upon APG. APG shall not be liable for any incidental or consequential damages, losses or expenses
directly or indirectly arising from the sale, handling, improper application or use of the goods or
from any other cause relating thereto and APG’s liability hereunder, in any case, is expressly limited
to the repair or replacement (at APG’s option) of goods.
Warranty is specically at the factory. Any on site service will be provided at the sole expense of the
Purchaser at standard eld service rates.
All associated equipment must be protected by properly rated electronic/electrical protection
devices. APG shall not be liable for any damage due to improper engineering or installation by the
Purchaser or third parties. Proper installation, operation and maintenance of the product becomes
the responsibility of the user upon receipt of the product.
Returns and allowances must be authorized by APG in advance. APG will assign a Return Material
Authorization (RMA) number which must appear on all related papers and the outside of the
shipping carton. All returns are subject to the nal review by APG. Returns are subject to restocking
charges as determined by APG’s “Credit Return Policy”.
1.Description
2. How To Read Your Label
3. Warranty
4. Dimensions
5. Installation Guidelines
6. Sensor and System Wiring
7. General Care
8. Repair Information
9. Hazardous Location Wiring
Table of Contents
5Installation Guidelines
The LPU-2127 should be installed in an area--indoors or outdoors--which meets the following
conditions:
• Ambient temperature between -40°C and 60°C (-40°F to +140°F)
• Ample space for maintenance and inspection
Additional care must be taken to ensure:
• The sensor has a clear, perpendicular sound path to the surface being monitored.
• The sensor is mounted away from tank or vessel walls and inlets.
• The sound path is free from obstructions and as open as possible for the 9° o axis beam
pattern.
• The sensor is tightened by hand to avoid cross-threading.
*Important: For user interface guide and sensor conguration see the full user manual.
4Dimensions
NOTE: Scan the QR code to the right to see the full
user manual on your tablet or smartphone. Or visit
https://www.apgsensors.com/support to nd it on our
website.
Part # 122950-0008
Doc #9004172 Rev A
Each label comes with a full model number, a part number, and a serial number. The model
number for the LPU-2127 will look something like this:
The model number tells you exactly what you have. You can also call us with the model, part, or the
serial number and we can help you.
You’ll also nd all hazardous certication information on the label.
SAMPLE: LPU-2127
The LPU-2127 loop powered ultrasonic level sensor provides continuous level/distance
measurement you can count on. It comes with a built in keypad for easy programming and is
certied for installation in hazardous areas in the US and Canada by CSA for Class I, Division 2,
Groups C & D and Class I, Zones 2 environments.
1Description
2How To Read Your Label
3Warranty
6Sensor and System Wiring Diagrams
4.00"
101.6 mm
5.50"
139.7 mm
6.05"
153.7 mm
2.00"
50.80 mm
2.40"
60.96 mm
2.30"
58.42 mm
2" NPT
4.00"
101.6 mm
5.50"
139.7 mm
6.05"
153.7 mm
2.00"
50.80 mm
2.40"
60.96 mm
2.30"
58.42 mm
2" NPT
4.25
Ammeter
COM mA
Power
Supply
(24Vdc)
+
4 - 20ma Out
+24vdc
Load Resistance
(or Input Card)
-
Wiring Instructions:
• With the lid of your LPU closed, use a screwdriver to remove the cable knock out.
• Clear the ashing.
• Open the lid of your LPU and install cable gland or conduit connection.
• Connect 12-28 VDC supply wire to (+) Terminal.
• Connect 4-20 mA output wire to (-) Terminal.
*Note: Load resistance @ 12VDC: 150 ohms Max and @ 24VDC: 600 ohms Max.
LPU-2127 Wiring
IMPORTANT: Refer to section 9 for Hazardous Location Wiring.
8Repair Information
9Hazardous Location Wiring
7General Care
Your level sensor is very low maintenance and will need little care as long as it was installed
correctly. However, in general, you should periodically inspect your LPU-2127 sensor to ensure the
sensor face is free of any buildup that might impede the function of the sensor. If sediment or other
foreign matter becomes trapped on the sensor face, detection errors can occur.
If you need to remove the sensor, be sure to store it in a dry place at a temperature between -40°
and 180° F.
If your LPU-2127 loop powered ultrasonic level sensor needs repair, contact us via email, phone, or
online chat on our website. We will issue you an RMA number with instructions.
• Phone: 888-525-7300
• Email: [email protected]
• Online chat at www.apgsensors.com

Other manuals for LPU-2127

1

Other APG Accessories manuals

APG MPX Series User manual

APG

APG MPX Series User manual

APG MPI-F Series User manual

APG

APG MPI-F Series User manual

APG LPU-2127 User manual

APG

APG LPU-2127 User manual

APG MPX User manual

APG

APG MPX User manual

APG MPXI-F Series User manual

APG

APG MPXI-F Series User manual

APG MPX User manual

APG

APG MPX User manual

APG MPX-T User manual

APG

APG MPX-T User manual

APG PWS Series User manual

APG

APG PWS Series User manual

APG MPI-E User manual

APG

APG MPI-E User manual

APG VBL Series User manual

APG

APG VBL Series User manual

APG MPX Series User manual

APG

APG MPX Series User manual

APG MNU IS Series User manual

APG

APG MNU IS Series User manual

APG IRU-2 4 Series User manual

APG

APG IRU-2 4 Series User manual

APG B Series User manual

APG

APG B Series User manual

APG LPU-2428 User manual

APG

APG LPU-2428 User manual

APG RPM Series User manual

APG

APG RPM Series User manual

APG PT-500 Series User manual

APG

APG PT-500 Series User manual

APG RPM Series User manual

APG

APG RPM Series User manual

APG MPX-E User manual

APG

APG MPX-E User manual

APG FLR Series User manual

APG

APG FLR Series User manual

Popular Accessories manuals by other brands

Hugo Brennenstuhl 802U-2-5V operating instructions

Hugo Brennenstuhl

Hugo Brennenstuhl 802U-2-5V operating instructions

Hytronik HMW38/RF Installation and instruction manual

Hytronik

Hytronik HMW38/RF Installation and instruction manual

Digital Dowsing Xcam SLS quick start guide

Digital Dowsing

Digital Dowsing Xcam SLS quick start guide

BEMKO SES60WH instructions

BEMKO

BEMKO SES60WH instructions

Dorner 2100 Series Installation, maintenance & parts manual

Dorner

Dorner 2100 Series Installation, maintenance & parts manual

IFM Electronic Efector 100 GM505S operating instructions

IFM Electronic

IFM Electronic Efector 100 GM505S operating instructions

Optex HX-80N installation instructions

Optex

Optex HX-80N installation instructions

Cornelius 0 installation manual

Cornelius

Cornelius 0 installation manual

Digistar EZ3600 Getting started

Digistar

Digistar EZ3600 Getting started

Philips CRP358 brochure

Philips

Philips CRP358 brochure

Philips SPF1002B Specifications

Philips

Philips SPF1002B Specifications

QOLSYS IQ MINI DW S Series Quick install guide

QOLSYS

QOLSYS IQ MINI DW S Series Quick install guide

BD Sensors DM 10 operating manual

BD Sensors

BD Sensors DM 10 operating manual

TFA WeatherHub 30.3306.02 quick reference

TFA

TFA WeatherHub 30.3306.02 quick reference

Waycon SX50 Series installation guide

Waycon

Waycon SX50 Series installation guide

VPI VOPEX-SV-2-LC installation guide

VPI

VPI VOPEX-SV-2-LC installation guide

SBG Systems IG-500A user manual

SBG Systems

SBG Systems IG-500A user manual

STEINEL IS 2180 ECO installation instructions

STEINEL

STEINEL IS 2180 ECO installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.