XP95A & Soteria UL 268 7th Edition Detectors
Installation Instructions
General
These instructions apply to the Apollo Soteria UL Bases. Please refer to the table below for
instructions on how to install:
Applicable Wiring Diagram (page 3) Applicable Products
Fig. 1 - New Installs (supports isolation) SA5000-210 – Soteria UL Base - 4”
SA5000-230 – Soteria UL Base - 6”
Fig. 2 - Retrofits or Isolator bypassed
with a Remote LED
SA5000-210 - Soteria UL Base - 4”
SA5000-230 - Soteria UL Base - 6”
Fig. 3 - Retrofits or Isolator bypassed
with a Common Remote LED
SA5000-210 - Soteria UL Base - 4”
SA5000-230 - Soteria UL Base - 6”
Installation
These products must be installed in accordance with the applicable NFPA standards, local
codes and jurisdictional authorities. Failure to follow these instructions may result in failure of
the detectors to report an alarm condition. Apollo Fire Detectors Limited is not responsible
for detectors which are improperly installed, maintained or tested.
Before installing these products, check the continuity, polarity and insulation resistance
of all wiring. Check that installation is in accordance with the fire system drawings and
conforms to all applicable local codes such as NFPA 72.
Use 3" octagonal box for direct connection to the base. 4" octagonal and 4" square boxes
may be used with compatible UL listed mounting brackets. When mounting on a wall, install
4" to 12" from the ceiling. Secure the base to the electrical box with appropriate screws.
Do not overtighten the screws. For information on how to set the address of each device
correctly refer to the section 'XPERT 8 Card Addressing' overleaf.
If you are using shielded cable, please follow the instructions below:
1. Connect the shield to the terminal on the base.
2. When shielded loop cable is used, connection of the shield, also known as the functional
earth (FE), must be terminated in accordance with the control panel manufacturer’s
recommendations and local codes.
3. Unless instructed otherwise, ensure that all segments of the loop cable has functional
earth (FE) continuity and take care that it is isolated from building earth (also known as
protective earth (PE)) points such as metalwork, cable trays or junction boxes.
PLEASE NOTE:
Smoke detectors are NOT to be used with detector guards.
During construction work it is essential that the detector has it’s dust cover fitted. The
build-up of dust inside a detector can lead to a trouble signal or false alarm.
14
39215-345/Issue 2
Technical Data XP95A Detectors
Detector Model No SA5150-650APO** SA5150-750APO** SA5800-450APO
Detector Type Soteria UL
Smoke Detector
Soteria UL Multi-Criteria
Detector (Smoke/Heat)
Discovery/Soteria UL
Non-isolating Heat Detector
Equivalent Obsolete
Dectector 58000-650 58000-750 58000-450
UL Listed Voltage 17- 28 V dc 17 - 28 V dc 17- 28 V dc
Modulation Voltage
(V peak to peak) 5 - 9 V 5 - 9 V 5 - 9 V
Maximum Alarm
Current LED on* 4 mA 4 mA 3.5 mA
Surge Current* 1 mA 1 mA 1 mA
Supervisory Current* 500 μA500μA500μA
Additional Remote
LED Current* 5 mA 5 mA 5 mA
Heat Element Rating N/A
Modes 1,3,4 Rate of Rise (RoR)
20ºF/min (11ºC/min). Mode 5
135ºF (57ºC)
135ºF (57ºC) - 210ºF (99ºC)
Sensitivity As SA5050-250APO As SA5050-350APO N/A
UL/ULC Instruction
Smoke-automatic fire detec-
tor for use with a S5022 UL/
ULC listed base
Smoke-automatic fire
detector head with integral
heat detector for use with a
S5022 UL/ULC listed base
Heat-automatic fire detector
for use with a S5022 UL/ULC
listed base
Test Method Please refer to test methods in the table above
Control Panel Refer to www.apollo-fire.co.uk for compatible panels
* All current measurements made with polling off **Isolation feature is only available in SA5150-650APO and SA5150-750APO
Technical Data Soteria UL Detectors
Detector Model No SA5050-250APO SA5050-350APO SA5500-450APO
Detector Type XP95A Smoke Detector XP95A Multi-Criteria
Detector (Smoke/Heat) XP95A Heat Detector
Equivalent Obsolete
Dectector 55000-650 55000-886 55000-450
UL Listed Voltage 17 - 28 V dc 17 - 28 V dc 17 - 28 V dc
Modulation Voltage
(V peak to peak) 5 - 9 V 5 - 9 V 5 - 9 V
Maximum Alarm
Current LED on* 4 mA 4 mA 2.5 mA
Surge Current* 1 mA 1 mA 1 mA
Supervisory Current* 340 μA500μA250μA
Additional Remote
LED Current* 5 mA 5 mA 5 mA
Heat Element Rating N/A Rate of Rise (RoR) 20ºF/min
(11ºC/min) 131ºF (55ºC)
Sensitivity UL 1.23%/Ft -2.09%/Ft
ULC 1.44%- 2.3%/Ft
UL 1.23%/Ft -2.09%/Ft
ULC 1.44%- 2.3%/Ft N/A
UL/ULC Instruction
Smoke-automatic fire detec-
tor for use with a S5022 UL/
ULC listed base
Smoke-automatic fire
detector head with integral
heat detector for use with a
S5022 UL/ULC listed base
Heat-automatic fire
detector for use with a
S5022 UL/ULC listed base
Test Method
Please refer to the panel manufacturer instructions
Spray with any of the following smoke products:
• Solo Detector Testers Solo A10 • Smoke Sabre Smoke
Detector Tester • Solo Detector Testers Solo 365 • Solo
Detector Testers Testifie
Hair Dryer
Control Panel Refer to www.apollo-fire.co.uk for compatible panels
L1 IN
L1 OUT
L1 IN
L1 OUT
L1 IN
L1 OUT
1416 64
2832 128
1416 64
2832 128
1416 64
2832 128
+
-
From
previous
device
or FACP
-L1
-L1
+L2
+R
-R
-L1
-L1
-L1
+L2
+R
-R
-L1
+L2
+R
-R
+
-
To next
device
or FACP
1416 64
2832 128
1416 64
2832 128
1416 64
2832 128
+
-+
-
From
previous
device
or FACP
To next
device
or FACP
L1 IN L1 IN L1 IN
L1 OUT L1 OUT L1 OUT
-L1
-L1
+L2
+R
-R
-L1
-L1
-L1
+L2
+R
-R
-L1
+L2
+R
-R
L1 IN
L1 OUT
L1 IN
L1 OUT
L1 IN
L1 OUT
1416 64
2832 128
1416 64
2832 128
1416 64
2832 128
+
-
From
previous
device
or FACP
-L1
-L1
+L2
+R
-R
-L1
-L1
-L1
+L2
+R
-R
-L1
+L2
+R
-R
+
-
To next
device
or FACP
32
Fig. 3 Schematic Wiring Diagram: Soteria UL Base to bypass isolator with a Common
Remote LED. To be used in a retrofit application for the older version of XP95A or
Discovery UL product. Can also be used when the isolator feature is not required
Fig. 2 Schematic Wiring Diagram: Soteria UL Base Detector to bypass isolator with remote
LED connection. To be used in a retrofit application for the older version of XP95A or
Discovery UL product. Can also be used when the isolator feature is not required
XPERT 8 Card Addressing
Select the desired address and remove the pips indicated
in black.
To reach maximum address range use Soteria UL Bases with
XPERT 8 card, Soteria Detector and Core Protocol Control
Panel.
Wiring
CAUTION: Do not use looped wire under wiring terminals. Break wire run to provide
supervision of connections. Terminals L1 and L2 are polarity sensitive. It is recommended the
wiring be no smaller than 18AWG (0.8mm2). Wire sizes up to 14 AWG (3.3mm2) may be used.
Warning: Check the base compatibility before installing
Check the polarity for Soteria UL detector installation
Fig. 1 Schematic Wiring Diagram: Soteria UL Base wiring with remote LED connection. To be
used with new installs for XP95A and Soteria UL detectors
456
Installation Diagram
2
For wiring, please see Fig 1, 2 & 3
i
Do Not
Overtighten
Screws
1
Screws not provided
i
LED
Orientation
3
Further details of XPERT 8 addressing can be found in the
Apollo Fire App, please refer to https://www.apollo-fire.
co.uk/training-support/apollo-mobile-app
For further technical information please refer to Technical
Bulletin 39215-400 Issue 1.
1
4
2
3
7
1.5mm A/F Hex
Grub Screw for use
as anti-tamper /
locking mechanism
i
53
141664
2 8 32 128
1 + 4 + 16 + 32 = 53
10
141664
2 8 32 128
2 + 8 = 10
© Apollo Fire Detectors Ltd 2021
Apollo Fire Detectors Ltd,
36 Brookside Road, Havant, Hampshire, PO9 1JR, UK
Tel +44 (0)23 9249 2412 e-mail: techsales@apollo-fire.com
Website: www.apollo-fire.co.uk
In the USA: Apollo America Inc.,
30 Corporate Drive, Auburn Hills, Michigan, 48326, USA
Tel: (248) 332-3900 Fax: (248) 692-0888
e-mail: info.us@apollo-fire.com
Website: www.apollo-fire.com

Other manuals for XP95A Series

2

Other Apollo Security Sensor manuals

Apollo REACH RW1000-460APO User manual

Apollo

Apollo REACH RW1000-460APO User manual

Apollo XPA-CB-11170-APO User manual

Apollo

Apollo XPA-CB-11170-APO User manual

Apollo ORB-OH-13001-APO User manual

Apollo

Apollo ORB-OH-13001-APO User manual

Apollo XP95A Series User manual

Apollo

Apollo XP95A Series User manual

Apollo Discovery ASD-1 User manual

Apollo

Apollo Discovery ASD-1 User manual

Apollo Smoke Detector XP95 User manual

Apollo

Apollo Smoke Detector XP95 User manual

Apollo Smoke Detector XP95 Operating and safety instructions

Apollo

Apollo Smoke Detector XP95 Operating and safety instructions

Apollo 55000-268 User manual

Apollo

Apollo 55000-268 User manual

Apollo XP95A Series User manual

Apollo

Apollo XP95A Series User manual

Apollo ORBIS ORB-OH-13003-APO User manual

Apollo

Apollo ORBIS ORB-OH-13003-APO User manual

Apollo RoadRunner User manual

Apollo

Apollo RoadRunner User manual

Apollo 55000-268 User manual

Apollo

Apollo 55000-268 User manual

Apollo REACH WIRELESS RW1000-700APO User manual

Apollo

Apollo REACH WIRELESS RW1000-700APO User manual

Apollo SENSI User manual

Apollo

Apollo SENSI User manual

Apollo XP95 series User manual

Apollo

Apollo XP95 series User manual

Apollo SA7100-100APO User manual

Apollo

Apollo SA7100-100APO User manual

Apollo 58000-300APO User manual

Apollo

Apollo 58000-300APO User manual

Apollo XPander XPA-CB-12034-APO User manual

Apollo

Apollo XPander XPA-CB-12034-APO User manual

Apollo XPander User manual

Apollo

Apollo XPander User manual

Apollo 65 Series User manual

Apollo

Apollo 65 Series User manual

Popular Security Sensor manuals by other brands

Optex OA-FUNXION quick start guide

Optex

Optex OA-FUNXION quick start guide

ZooZ ZSE42 800LR user manual

ZooZ

ZooZ ZSE42 800LR user manual

NuAire 230PIR installation guide

NuAire

NuAire 230PIR installation guide

iRay Technology Luna1012X user manual

iRay Technology

iRay Technology Luna1012X user manual

Vents CO2-1 user manual

Vents

Vents CO2-1 user manual

Bosch ISN-AP1-T installation guide

Bosch

Bosch ISN-AP1-T installation guide

Iget HOME XP4B installation manual

Iget

Iget HOME XP4B installation manual

Extech Instruments 401050 user guide

Extech Instruments

Extech Instruments 401050 user guide

Schabus SHT 5001 Operation manual

Schabus

Schabus SHT 5001 Operation manual

Bosch Truvo Original instructions

Bosch

Bosch Truvo Original instructions

BeNext MoLiTe quick start

BeNext

BeNext MoLiTe quick start

Ursalink EM300 Series user guide

Ursalink

Ursalink EM300 Series user guide

Baumer UNDK 20I6903/S35A manual

Baumer

Baumer UNDK 20I6903/S35A manual

olympia electronics BS-470 quick start guide

olympia electronics

olympia electronics BS-470 quick start guide

Interlogix ACL870SU-BSMF installation manual

Interlogix

Interlogix ACL870SU-BSMF installation manual

Johnson Controls PG9350SL user manual

Johnson Controls

Johnson Controls PG9350SL user manual

schmersal AZ 16-STS30-02 operating instructions

schmersal

schmersal AZ 16-STS30-02 operating instructions

Tyco SD-304C PG2 installation instructions

Tyco

Tyco SD-304C PG2 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.