manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Apollo
  6. •
  7. Security Sensor
  8. •
  9. Apollo XPander XPA-CB-12034-APO User manual

Apollo XPander XPA-CB-12034-APO User manual

This manual suits for next models

8

Other Apollo Security Sensor manuals

Apollo XPander User manual

Apollo

Apollo XPander User manual

Apollo SENSI User manual

Apollo

Apollo SENSI User manual

Apollo Discovery ASD-1 User manual

Apollo

Apollo Discovery ASD-1 User manual

Apollo XP95A Series User manual

Apollo

Apollo XP95A Series User manual

Apollo XPA-CB-11170-APO User manual

Apollo

Apollo XPA-CB-11170-APO User manual

Apollo 58000-300APO User manual

Apollo

Apollo 58000-300APO User manual

Apollo ORB-OH-13001-APO User manual

Apollo

Apollo ORB-OH-13001-APO User manual

Apollo 55000-268 User manual

Apollo

Apollo 55000-268 User manual

Apollo Smoke Detector XP95 User manual

Apollo

Apollo Smoke Detector XP95 User manual

Apollo 55000-268 User manual

Apollo

Apollo 55000-268 User manual

Apollo RoadRunner User manual

Apollo

Apollo RoadRunner User manual

Apollo 65 Series User manual

Apollo

Apollo 65 Series User manual

Apollo XP95A Series User manual

Apollo

Apollo XP95A Series User manual

Apollo ORBIS ORB-OH-13003-APO User manual

Apollo

Apollo ORBIS ORB-OH-13003-APO User manual

Apollo Smoke Detector XP95 Operating and safety instructions

Apollo

Apollo Smoke Detector XP95 Operating and safety instructions

Apollo SA7100-100APO User manual

Apollo

Apollo SA7100-100APO User manual

Apollo REACH WIRELESS RW1000-700APO User manual

Apollo

Apollo REACH WIRELESS RW1000-700APO User manual

Apollo XP95 series User manual

Apollo

Apollo XP95 series User manual

Apollo XP95A Series User manual

Apollo

Apollo XP95A Series User manual

Apollo REACH RW1000-460APO User manual

Apollo

Apollo REACH RW1000-460APO User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

XPander Smoke and Heat Detectors
Installation Guide
General
Do not install any XPander equipment until a full site survey has been completed using the
XPander site survey tool. A maximum of 5 interfaces are permitted for each site. For sites
that require more than 5 interfaces please contact Apollo. All installation engineers must
have had certied XPander training.
The XPander smoke and heat detector variants are available under the following part
numbers:
Complete Units
Part Number Description
XPA-CB-12034-APO XPander Optical detector with base
XPA-CB-13032-APO XPander Multisensor detector with base
X PA - C B - 1117 0 - A P O XPander Heat A1R detector with base
X PA - C B - 11171 - A P O XPander Heat CS detector with base
Spares
Part Number Description
XPA-WB-10022-APO XPander Mounting base only
XPA-OP-12034-APO XPander Optical head only
XPA-OH-13023-APO XPander Multisensor head only
X PA - H T -1117 0 - A P O XPander Heat A1R head only
X PA - H T -1117 1- A P O XPander Heat CS head only
The installation must conform to BS5839-1 (or applicable local codes). All detectors are suit-
able for indoor use only.
© Apollo Fire Detectors Limited 2006-2010
Apollo Fire Detectors Limited, 36 Brookside Road, Havant, Hampshire, PO9 1JR, UK
Tel: +44 (0) 23 9249 2412 Fax: +44 (0) 23 9249 2754
Email: techsales@apollo-re.co.uk Website: www.apollo-re.co.uk
1
39214-394/Issue 3
Battery Type
6 x AA, 1.5V Alkaline Duracell Procell (MN1500, LR6)
When replacing batteries, allow the device to power down for a period of two minutes
before installing replacements.
Note: When replacement batteries are required all batteries must be replaced together.
Technical Data
Operating voltage 2.8-5VDC
Operating temperature –10°C to +50°C
32
Installation
All detectors must be sited in accordance with the original approved design and site
survey details. Where practical the detector’s LED should face towards the room’s
entrance.
1. Twist the ceiling mounting plate anti-clockwise to remove it from the mounting base.
2. The ceiling mounting plate must be tted using both mounting holes and suitable
xings or fasteners. (Fig 1)
Note: Any screw heads must be ush or semi ush with the internal surface of the ceiling
mount otherwise the battery PCB may be damaged.
3. Attach the mounting base to the ceiling mounting plate ensuring the tamper switch
spring assembly makes contact. Locate the three lugs and twist clockwise.
4. Fit the detector to the mounting base.
5. Fit the power jumper shorting link and commission the unit according to the XPander
commissioning guide PP2286.
Locking Mechanism
The detectors can be locked into the base by removing a tab as shown in Fig.2.
To unlock the detector, insert a 1.5mm hex driver or similar diameter tool into the small hole
opposite the XPERT card and twist the detector anti-clockwise.
The XPander base module can be locked to the mounting plate by means of a grub screw.
Access to which is through the base module cover label opposite the XPERT card
The address of the unit is set using the XPERT card, see table overleaf. Commission the
detector according to the XPander commissioning guide PP2286.
XPERT card insertion and removal
Removal requires access to the inner section of the base. Detach the detector from its
base. Insert a at-blade screwdriver just inside the rim of the base above the XPERT card
and disengage the card retaining clip whilst pulling the XPERT card out.
XPERT Card Addressing
The XPander XPERT card is specically designed for XPander products and has proled
address pips for ease of installation. The use of standard XPERT cards is not recommended.
Select the desired address and remove the pips indicated in black. Remove pips with a
small screwdriver.
© Apollo Fire Detectors Limited 2007 TP
Fig 1 Mounting details
1
2
4
8
16
32
64
1
1
1
2
4
8
16
32
64
10
10
1
2
4
8
16
32
64
9
9
1
2
4
8
16
32
64
8
8
1
2
4
8
16
32
64
7
7
1
2
4
8
16
32
64
6
6
1
2
4
8
16
32
64
5
5
1
2
4
8
16
32
64
4
4
1
2
4
8
16
32
64
3
3
1
2
4
8
16
32
64
2
2
1
2
4
8
16
32
64
11
11
1
2
4
8
16
32
64
20
20
1
2
4
8
16
32
64
19
19
1
2
4
8
16
32
64
18
18
1
2
4
8
16
32
64
17
17
1
2
4
8
16
32
64
16
16
1
2
4
8
16
32
64
15
15
1
2
4
8
16
32
64
14
14
1
2
4
8
16
32
64
13
13
1
2
4
8
16
32
64
12
12
1
2
4
8
16
32
64
21
21
1
2
4
8
16
32
64
30
30
1
2
4
8
16
32
64
29
29
1
2
4
8
16
32
64
28
28
1
2
4
8
16
32
64
27
27
1
2
4
8
16
32
64
26
26
1
2
4
8
16
32
64
25
25
1
2
4
8
16
32
64
24
24
1
2
4
8
16
32
64
23
23
1
2
4
8
16
32
64
22
22
1
2
4
8
16
32
64
31
31
1
2
4
8
16
32
64
40
40
1
2
4
8
16
32
64
39
39
1
2
4
8
16
32
64
38
38
1
2
4
8
16
32
64
37
37
1
2
4
8
16
32
64
36
36
1
2
4
8
16
32
64
35
35
1
2
4
8
16
32
64
34
34
1
2
4
8
16
32
64
33
33
1
2
4
8
16
32
64
32
32
1
2
4
8
16
32
64
41
41
1
2
4
8
16
32
64
50
50
1
2
4
8
16
32
64
49
49
1
2
4
8
16
32
64
48
48
1
2
4
8
16
32
64
47
47
1
2
4
8
16
32
64
46
46
1
2
4
8
16
32
64
45
45
1
2
4
8
16
32
64
44
44
1
2
4
8
16
32
64
43
43
1
2
4
8
16
32
64
42
42
1
2
4
8
16
32
64
51
51
1
2
4
8
16
32
64
60
60
1
2
4
8
16
32
64
59
59
1
2
4
8
16
32
64
58
58
1
2
4
8
16
32
64
57
57
1
2
4
8
16
32
64
56
56
1
2
4
8
16
32
64
55
55
1
2
4
8
16
32
64
54
54
1
2
4
8
16
32
64
53
53
1
2
4
8
16
32
64
52
52
1
2
4
8
16
32
64
63
63
1
2
4
8
16
32
64
62
62
1
2
4
8
16
32
64
61
61
XPERT card addressing forXP95 and Discovery
Select the desired address and remove the pips indicated in black. Remove pips with a small screwdriver.
1
2
4
8
16
32
64
124
124
1
2
4
8
16
32
64
126
126
1
2
4
8
16
32
64
125
125
1
2
4
8
16
32
64
80
80
1
2
4
8
16
32
64
79
79
1
2
4
8
16
32
64
78
78
1
2
4
8
16
32
64
77
77
1
2
4
8
16
32
64
76
76
1
2
4
8
16
32
64
70
70
1
2
4
8
16
32
64
69
69
1
2
4
8
16
32
64
68
68
1
2
4
8
16
32
64
67
67
1
2
4
8
16
32
64
66
66
1
2
4
8
16
32
64
65
65
1
2
4
8
16
32
64
64
64
1
2
4
8
16
32
64
71
71
1
2
4
8
16
32
64
75
75
1
2
4
8
16
32
64
74
74
1
2
4
8
16
32
64
73
73
1
2
4
8
16
32
64
72
72
1
2
4
8
16
32
64
81
81
1
2
4
8
16
32
64
90
90
1
2
4
8
16
32
64
89
89
1
2
4
8
16
32
64
88
88
1
2
4
8
16
32
64
87
87
1
2
4
8
16
32
64
86
86
1
2
4
8
16
32
64
85
85
1
2
4
8
16
32
64
84
84
1
2
4
8
16
32
64
83
83
1
2
4
8
16
32
64
82
82
1
2
4
8
16
32
64
91
91
1
2
4
8
16
32
64
100
100
1
2
4
8
16
32
64
99
99
1
2
4
8
16
32
64
98
98
1
2
4
8
16
32
64
97
97
1
2
4
8
16
32
64
96
96
1
2
4
8
16
32
64
95
95
1
2
4
8
16
32
64
94
94
1
2
4
8
16
32
64
93
93
1
2
4
8
16
32
64
92
92
1
2
4
8
16
32
64
101
101
1
2
4
8
16
32
64
110
110
1
2
4
8
16
32
64
109
109
1
2
4
8
16
32
64
108
108
1
2
4
8
16
32
64
107
107
1
2
4
8
16
32
64
106
106
1
2
4
8
16
32
64
105
105
1
2
4
8
16
32
64
104
104
1
2
4
8
16
32
64
103
103
1
2
4
8
16
32
64
102
102
1
2
4
8
16
32
64
111
111
1
2
4
8
16
32
64
120
120
1
2
4
8
16
32
64
119
119
1
2
4
8
16
32
64
118
118
1
2
4
8
16
32
64
117
117
1
2
4
8
16
32
64
116
116
1
2
4
8
16
32
64
115
115
1
2
4
8
16
32
64
114
114
1
2
4
8
16
32
64
113
113
1
2
4
8
16
32
64
112
112
1
2
4
8
16
32
64
123
123
1
2
4
8
16
32
64
122
122
1
2
4
8
16
32
64
121
121
Snip along marked lines and remove this
part to lock the detector to the base.
© Apollo Fire Detectors Limited 2004/JDR
Apollo Fire Detectors Limited 2008/TP
Fig 2. Locking Mechanism