Aprilaire 76C User manual

Mode[ 76C Dehumidifier Control
anua[
Installedby:.
InstallerPhone: DateInstalled:
PLEASE LEAVE THiS MANUAL WiTH TidE HOMEOWNER ]
ThankyouforyourpurchaseoftheModel76CDehumidifierControl.Yourcontrolallowsyou
toset therelativehumiditylevelforyourhomeandprovidescontrolofthedehumidifierfroma
convenientlivingspacelocation.TheModel76Cusesanonboardsensorto monitortherelative
humidityin thespacein whichit is locatedanddisplaysthemeasuredrelativehumidityonthe
digitaldisplay.
TheModel76Ccanalsoactasa remoteeentrelforyourdehumidifierif it is locatedinan
inconvenientorhardto accessarea.Forexample,whenthedehumidifierislocatedinand
dehumidifyingacrawl spaceora basement,theModel76Ccanbe installedwhereyouspend
mostofyourtime, allowingyoutomakechangestothesettingandto seewhat thehumidityis
in theseareaswithouthavingtoaccessthedehumidifier.
Thecontrolwill allowyouto setthe desiredhumiditylevelin yourhomeandcanbeusedto
turndehumidificationOnorOff.
Thematerialsina homeact likea sponge,sothemoisturein thematerialsof yourhomeis at
thesamelevelastheair.After dryingtheair,the materialsofthehomewifl releasemoisture
backintothe air untiltheyareagainat the samelevel.Asa result,it is notuncommonforthe
dehumidifierto operatefor anextendedperiodoftime whenfirst installed.
BeginbypressingtheONbuttonandONwill be displayedonthe LCDScreen(seeLCDdisplay
in Figure1).Usethearrowbuttonsto setthecontrolat 59%whenfirst installed.Allowthe
dehumidifierto runfor 24hoursbeforedecidingif youwant tochangethehumiditysetting.
A Raisethe setting ifyeupreferthe air te be Jessdry; thiswili reducetheamountof
timethat the dehumidifierruns.
yLewerthe setting if yeupreferthe air te be mere dry; thiswifl increasethe amount
oftimethat the dehumidifierruns.
BeginbypressingtheONbuttonandON
will be displayedontheLCDScreen(see
LCDdisplayinFigure1).Usethearrow
buttonsto setthecontroltoa dryness
levelof 3whenfirst installed.Allow the
dehumidifierto runfor 24hoursbefore
decidingifyouwant to changethedryness
levelsetting,
increase the dryness level setting
ifyouprefer the air te be meredry;
thiswill increasetheamountoftime
thatthedehumidifierruns.
TDecreasethe dryness Jevelsetting
if yeupreferthe air te be Jessdry;
thiswill reducetheamountoftime
thatthedehumidifierruns.
Dwness
LeveJ
Setting
1 84% 71% 60%
2 86% 73% 61% 52%
3 74% 63% 53% 45%
4 64% 54% 45% 39%
5 55% 46% 39% 33%
6 47% 39% 33% 28%
7 40% 34% 28% 24%
Nete: Thistable is for reference only.
Thedrynesslevelsettingscanbeapproximatedto relativehumidity(%RH}usingTabJe1.
LCDDisplay
ModeButtons- Use
to turncontrolOn/Off. ,A_V ' Buttons- Usetoview and
sethumidityor drynesslevelsetting.
2 3
Numbersshow ,,
currentroomhumidity--_
ORhumiditysetting
Dehumidifying
OFF:ControlOff
SET_ SET_sdisplayed
whenA orY is
pressed.Thevalue
OFF displayedisthe
........
,ooo
See J:i_lure 5.
N+_: ControlLimitExceeded.
SeeCuntreJLimits, page6.
90 1636
Numbersshowremote _,,_
locationhumidityOR_,_
drynesslevelsetting
Dehumidifying OFF SETy-"- SETisdisplayed
whenA or_'is
pressed.Thevalue
displayedisthe
drynesslevel.
SeeFi_l_re7.
OFF:ControlOff
90 1636
®PressingtheONbuttonwiJJturnonthecontrol.
®Pressingthe OFFbuttonwill turn off thecontrok
®ThecontrolwiJlcontinueto displaythemeasured
humiditywhenOFR
®Thehumidityordrynesslevelsettingcannotbe
changedwhenthecontrolisOFR
ii!i!i!i!iiiii_iiii_ii!_i!_!i_iillili!_iiiii!_iiililii_i!i_i_i_ii_ii_iiiii_
i!i!i!i!i!i!i!i!i!i_!_!_!ii_!_!i!_i_i!_ii_i!iii!!_!_!_!i!i! _!i_ii_!_i!i!i!i!! ! _!i_il_ _!_i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!i!!!i!!!!!i!i!i!i!
Thefirst pressofeitherthe,A or'_' buttonwill displaythe humidityordrynesslevel
settingontheLCD.
Eachsubsequentpushof theupordown
buttonswill changethe settingby 1%or 1
drynesslevel.
If a buttonishelddown,thesettingwill
continuallychangeby1% or 1drynesslevel
every1/2secondfor aslongasthebuttonis
pressed.
Thecontrolwill exitthe settingscreen5
secondsafter thelastbuttonpress/release.
g0 1637
SET
90-1638
®Whenthemeasuredhumidityisgreaterthanthesetting,thecontrolwill turnonthe
dehumidifierand01'_1will blinkontheLCDdisplay.
®Whenthemeasuredhumidityfalls 3% belowthe setting,thecontrolwill turn off the
dehumidifierandONwill stopblinking.
®Thecontrolsendsthedrynessleveltothedehumidifier.
o OnceperCyclePeriod(setbyyourinstallerin thedehumidifier),the dehumidifierwill sample
theair intheareaservedbythe dehumidifier.
o If thedew pointoftheincomingair is abovethedrynesslevel,thedehumidifierwill turnon
andONwill blinkonthe LCDdisplay.
o Whenthedewpointofthe incomingair falls belowthesetting,the dehumidifierwill turn
off andOl'awill stopblinking.
Thecontrollimitsareusedto makesurethedehumidifierdoesnotrunwhenconditionsare
outsideoftheoperatinglimits.Dehumidifiersarenotaseffectivewhenconditionsareoutside
oftheoperatinglimits.Forexample,thedehumidifierwill notremovemuchmoisturewhen
conditionsarecoo!anddry.Controllimitsallowthedehumidifiertowork efficientlywithin the
operatingrangeandturnoff whenconditionsareoutsideof theselimits.
®Dew Peint Lewer Limit:40°FExternalControl
oTemperatureHigh Limit:99°FExternalControl
105°FRemoteControl
oTemperatureLow Limit:50°FRemoteOontrol
®Thedehumidifierwill turnoff ifoneofthe controllimitshasbeenexceeded.
o If thecontrolmeasuresa dew pointbelow40°FORa temperatureabove99°F,thecontrol
will deactivatethedehumidifieroutputif activelydehumidifying,thedehumidifierwill stop
dehumidifying,and01'_1and_- will blinkontheLCDscreen(seeFigure 2).
o Thecontrolwill resumenormaloperationwhenconditionsfall backwithin thecontrollimits.
o Thedehumidifierwill turnoff ifoneofthe controllimitshasbeenexceeded.
o If thedehumidifiermeasuresa temperaturebelow50°Forabove105°F,the dehumidifier
will stopdehumidifying.
o Thecontrolwill resumenormaloperationwhenconditionsinthe remotespacefall back
withinthe dehumidifiercontrollimits.
ThesurfaceoftheModel76CDehumidifierControlcanbecleanedwith wateror anomabrasive
householdcleaner,includingglasscleaner.Donet spray any liquid directly entethe eentrel.
Spraywateror acleanerontoasoftc!othandgentlywipethe surfaceofthecontrol.
6 7
Gretchen,we've useda couple different footers for Carrier. Not sure
which one shouN be usedfor what, or if we shouN be usingthe same
one for everything. Ithink the bottomone is newer.
© 2014CAC/BDP
7310WestMorrisSt,,Indianapolis,IN46231
Form#OG--DEHXXCDA-01
10010838 B2206367A3.I4
Copyright 2014 CAC /BDP _,7310 W. Morris St, _,Indianapolis, IN 46231
EditionDate:03/I4
Manufacturerreservesthe right tochange,at anythem,
specificationsanddesignswithout noticeandwithout obligations,
Catalog No: OMWAV-02
Replaces:OM#AV_01
10010838 B2206367A 3.14

Other Aprilaire Control Unit manuals

Aprilaire 70 Living Space Control User manual

Aprilaire

Aprilaire 70 Living Space Control User manual

Aprilaire 1700 User manual

Aprilaire

Aprilaire 1700 User manual

Aprilaire 65 User manual

Aprilaire

Aprilaire 65 User manual

Aprilaire Premium Digital Humidifier Control Setup guide

Aprilaire

Aprilaire Premium Digital Humidifier Control Setup guide

Aprilaire 65 User manual

Aprilaire

Aprilaire 65 User manual

Aprilaire 76 User manual

Aprilaire

Aprilaire 76 User manual

Popular Control Unit manuals by other brands

Konica Minolta Pi1803e quick guide

Konica Minolta

Konica Minolta Pi1803e quick guide

Siemens RWF50 Application guide

Siemens

Siemens RWF50 Application guide

ITRON 100W-R installation guide

ITRON

ITRON 100W-R installation guide

Siemens 6ES5-424 Technical reference manual

Siemens

Siemens 6ES5-424 Technical reference manual

National Instruments SCC Series quick start guide

National Instruments

National Instruments SCC Series quick start guide

NI PXI-6682 user manual

NI

NI PXI-6682 user manual

Siemens SIRIUS 3SB3 operating instructions

Siemens

Siemens SIRIUS 3SB3 operating instructions

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

Agilent Technologies N2757A installation guide

Agilent Technologies

Agilent Technologies N2757A installation guide

Puls UZK12.071 Instructions for use

Puls

Puls UZK12.071 Instructions for use

XEMEX SUNGATE WatchTalk installation manual

XEMEX

XEMEX SUNGATE WatchTalk installation manual

Lenze EMF2192IB Mounting instructions

Lenze

Lenze EMF2192IB Mounting instructions

Allen-Bradley ControlNet 1747-ACN15 user manual

Allen-Bradley

Allen-Bradley ControlNet 1747-ACN15 user manual

Emerson SAPAG 7700 Installation, Maintenance and Adjustment Instruction

Emerson

Emerson SAPAG 7700 Installation, Maintenance and Adjustment Instruction

Acromag ACEX4405-LF user manual

Acromag

Acromag ACEX4405-LF user manual

Chamberlain LiftMaster Professional CB124 instructions

Chamberlain

Chamberlain LiftMaster Professional CB124 instructions

TECSYSTEM NT538 WS instruction manual

TECSYSTEM

TECSYSTEM NT538 WS instruction manual

Ebyte E34-2G4D20D user manual

Ebyte

Ebyte E34-2G4D20D user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.