ARC Flex 2JB-HRX User manual

FLEX2JB
HRX
Instruction Manual

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 1 of 69
Service Information
Your New Radio Remote Control System
Thank you for your purchase of ARC Flex 2JB-HRX radio remote control system. Without a doubt,
our Flex 2JB-HRX system is the ultimate solution for providing precise, undeterred, and safe control
of your material.
If your product ever needs modification or service, please contact our representative in your country
or at the following location:
World Headquarter:
Advanced Radiotech Corporation
No.3, South 1st Road, Chien Chen District
Kaohsiung, Taiwan
Telephone:
+886 7 812 8112
Fax Number:
+886 7 812 8119
Website:
www.advanced-radiotech.com
E-mails:
sales@advanced-radiotech.com
All rights reserved. This notice applies to all copyrighted materials included with this product, including,
but not limited to, this manual and software embodied within the product. This manual is intended for
the sole use of the person(s) to whom it was provided, and any unauthorized distribution of the
manual or dispersal of its contents is strictly forbidden. This manual may not be reproduced in whole
or in part by any means whatsoever without the expressed written permission of ARC.

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 2 of 69
PRODUCT MANUAL SAFETY INFORMATION
Advanced Radiotech Corporation (ARC) offers a broad range of radio remote control product for
material handling applications. This manual has been prepared by ARC to provide information and
recommendations for the installation, use, operation and service of ARC’s material handling products
and systems (ARC Products). Anyone who uses, operates, maintains, services, installs or owns ARC
Products should know, understand, and follow the instructions and safety recommendations in this
manual for ARC Products.
The recommendations in this manual do not take precedence over any of the following requirements
relating to cranes, hoists lifting devices or other material handling equipment which use or include
ARC Products:
Instructions, manuals, and safety warnings of the manufacturers of the equipment where the
radio system is used.
Plant safety rules and procedures of the employers and the owners of facilities where the
ARC Products are being used.
Safety standards and practices for the industries in which ARC Products are used.
This manual does not include or address the specific instructions and safety warnings of these
manufacturers or any of the other requirements listed above. It is the responsibility of the owners,
users and operators of the ARC Products to know, understand and follow all of these requirements. It
is the responsibility of the employer to make its employees aware of all of the above listed
requirements and to make certain that all operators are properly trained. No one should use ARC
Products prior to becoming familiar with and being trained in these requirements and the
instructions and safety recommendations in this manual.
WARRANTY INFORMATION
For information on ARC’s product warranties, please contact ARC representative nearest to you or
visit www.advanced-radiotech.com.
FCC WARNINGS and CAUTIONS
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference; and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
(b) For a Class B digital device or peripheral, the instructions furnished the user shall include the
following or similar statement, placed in a prominent location in the text of the manual:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 3 of 69
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the authority to operate equipment.
This device and its antenna must not be co-located or operating in conjunction with any other
antenna or transmitter.
End-users and installers must be provided with antenna installation instructions and transmitter
operating conditions for satisfying RF exposure compliance.
FCC MPE :This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment for body-worn configuration in direct contact to the phantom.
IC WARNINGS
RSS-Gen Issue 4 8.4
According to RSS-Gen Issue 4 section 8.4, User manuals for license-exempt radio apparatus shall
contain the following text, or an equivalent notice that shall be displayed in a conspicuous location,
either in the user manual or on the device, or both:
(English)
This device complies with Industry Canada's license-exempt RSSs. Operation is subject to the
following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
(French)
Le présent appareil est conforme aux CNR d'Industrie Canada applicables auxappareils radio
exempts de licence.L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage adioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Industry Canada ICES-003 Compliance Label:
CAN ICES-3 (B)/NMB-3(B)
IC MPE: This equipment complies with ISED radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm between
the radiator & your body.
Cet équipement est conforme aux limites d'exposition au rayonnement ISED établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé à une distance minimale de
20 cm entre le radiateur et votre corps

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 4 of 69
Table of Contents
Page
1. Introduction 5
2. Radio Controlled Safety 6
3. General System Information
3.1 Transmitter
3.1.1 Flex 2JB-HRX Joystick Transmitter Illustration 11
3.1.2 Flex 2JB-HRX Lever Transmitter Illustration 12
3.2 Receiver
3.2.1 External Illustration 13
3.2.2 Internal Illustration 14
4. Function Settings
4.1 Transmitter
4.1.1 Transmitter Firmware Version 15
4.1.2 Transmitter Channel Programming 16
4.1.3 Remote Pairing 18
4.1.4 Transmitter Start Function Settings 22
4.1.5 Transmitter Inactivity Timer Settings 22
4.1.6 Transmitter Output Power Settings 22
4.1.7 Infrared (IR) Programming 23
4.1.8 PB1~PB7 Function Programming 24
4.1.9 Transmitter Access Card (TAC) Programming 27
4.1.10 Display Frequency Band 28
4.1.11 Infrared Function Settings 28
4.1.12 Zero-G Sensor Settings 28
4.2 Receiver
4.2.1 Button Output Functions 29
4.2.2 Button Output Settings 30
4.2.3 Joystick and Lever Analog Outputs 32
4.2.4 Jumper Functions 32
4.2.5 Function Outputs 33
4.2.6 Programming 34
4.2.7 Indicator Light and Buzzer Installation 52
4.2.8 System Channels Table (433~439MHz) 53
4.2.9 System Channels Table (863~869MHz) 54
4.2.10 System Channels Table (921~927MHz) 55
5. Receiver Installation
5.1 Wiring Instructions
5.1.1 Receiver Output Layouts 56
5.1.2 Joystick Wiring Diagrams 56
5.1.3 Lever Wiring Diagrams 57
5.2 Pre-installation Precautions 57
5.3 Step-By-Step Installation 58
6. Operating Procedures
6.1 General Operation 61
6.2 Output Resolution Adjustments 62
6.3 A/B Button Select Operation 62
6.4 A/B Toggle Switch Select Operation 62
6.5 Pitch & Catch Operation 63
6.6 Transmitter Access Card (TAC) Operation 63
6.7 Changing Batteries 63
6.8 Battery Charging 64
6.9 System Status Indications 65
7. General Specifications 68
8. EU Declaration of Conformity 69

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 5 of 69
1. Introduction
The Flex 2JB-HRX joystick and lever radio remote control systems are designed for control of
industrial hydraulic equipment and machinery such as mobile cranes, excavators, tractors,
loaders, etc…
Each Flex 2JB-HRX joystick and lever system consists of a transmitter bellybox and a receiver
unit. Other standard-equipped accessories include transmitter waist belt, shoulder strap,
compass direction label sheets, output cable and instruction manual CD.
List of notable features include:
* Advanced Controls – the system utilizes dual advanced microprocessor controls with
32bit CRC and Hamming Code, providing ultra fast, safe, precise, and error-free encoding
and decoding.
* Frequency Hopping RF Transceiver – the system automatically search-and-lock onto a
free and uninterrupted channel at every system startup or during operation when
encountering radio interference. The system is also capable of two-way communication
between the transmitter and receiver and as well as receiver to receiver with system status
feedbacks.
* Programmable Transmitter Access Card (TAC) – the optional transmitter access card
feature (TAC) further guard against any unauthorized personnel from operating the
transmitter. The TAC can also be individually programmed unlocking any specific function
or functions on the transmitter allowing a more experienced or qualified user to operate.
* Zero-G Sensor Imbedded – the transmitter is embedded with a Zero-G sensor to guard
against any unintended control of the crane or equipment when transmitter is thrown or
dropped.
* Wireless Remote Pairing Function – system information can be transferred wirelessly
between two transmitters or between a transmitter and a receiver without the hassle of
resetting the spares.
* Reliable Joysticks and Switches – the in-house designed joysticks and levers are rated
for more than five million operating cycles.
* Low Power Consumption – requires only four “AA” alkaline batteries for more than 100
hours of uninterrupted operation between replacements.
* Durable Nylon and Fiberglass Composite Enclosures – highly resistance to breakage
and deformation even in the most abusive environments. The receiver enclosures and
output cables are UL94-V0 rated. The transmitter and receiver enclosures are IP66 rated.
* Full Compliance – all systems are fully complied with the FCC Part-15 Rules, IC and
European Safety Standards.

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 6 of 69
2. Radio Controlled Safety
WARNINGS and CAUTIONS
Throughout this document WARNING and CAUTION statements have been deliberately placed to highlight items
critical to the protection of personnel and equipment.
WARNING – A warning highlights an essential operating or maintenance procedure, practice, etc. which if
not strictly observed, could result in injury or death of personnel, or long term physical hazards.
Warnings are highlighted as shown below:
WARNING
CAUTION – A caution highlights an essential operating or maintenance procedure, practice, etc. which if
not strictly observed, could result in damage to, or destruction of equipment, or loss of functional
effectiveness. Cautions are highlighted as shown below:
CAUTION
WARNINGS and CAUTIONS SHOULD NEVER BE DISREGARDED.
The safety rules in this section are not intended to replace any rules or regulations of any applicable local, state,
or federal governing organizations. Always follow your local lockout and tagout procedure when maintaining any
radio equipment. The following information is intended to be used in conjunction with other rules or regulations
already in existence. It is important to read all of the safety information contained in this section before installing
or operating the Radio Control System.

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 7 of 69
2.1 CRITICAL INSTALLATION CONSIDERATIONS
WARNING
PRIOR TO INSTALLATION AND OPERATION OF THIS EQUIPMENT, READ AND DEVELOP AN
UNDERSTANDING OF THE CONTENTS OF THIS MANUAL AND THE OPERATION MANUAL OF THE
EQUIPMENT OR DEVICE TO WHICH THIS EQUIPMENT WILL BE INTERFACED. FAILURE TO FOLLOW
THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
ALL EQUIPMENT MUST HAVE A MAINLINE CONTACTOR INSTALLED AND ALL TRACKED CRANES,
HOISTS, LIFTING DEVICES AND SIMILAR EQUIPMENT MUST HAVE A BRAKE INSTALLED. FAILURE TO
FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
AN AUDIBLE AND/OR VISUAL WARNING MEANS MUST BE PROVIDED ON ALL REMOTE-CONTROLLED
EQUIPMENT AS REQUIRED BY CODE, REGULATION, OR INDUSTRY STANDARD. THESE AUDIBLE
AND/OR VISUAL WARNING DEVICES MUST MEET ALL GOVERNMENTAL REQUIREMENTS. FAILURE TO
FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
FOLLOW YOUR LOCAL LOCKOUT TAGOUT PROCEDURE BEFORE MAINTAINING ANY REMOTE-
CONTROLLED EQUIPMENT. ALWAYS REMOVE ALL ELECTRICAL POWER FROM THE CRANE, HOIST,
LIFTING DEVICE OR SIMILAR EQUIPMENT BEFORE ATTEMPTING ANY INSTALLATION PROCEDURES.
DE-ENERGIZE AND TAGOUT ALL SOURCES OF ELECTRICAL POWER BEFORE TOUCH-TESTING ANY
EQUIPMENT. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND
DAMAGE TO EQUIPMENT.
THE DIRECT OUTPUTS OF THIS PRODUCT ARE NOT DESIGNED TO INTERFACE DIRECTLY TO TWO
STATE SAFETY CRITICAL MAINTAINED FUNCTIONS, I.E., MAGNETS, VACUUM LIFTS, PUMPS,
EMERGENCY EQUIPMENT, ETC. A MECHANICALLY LOCKING INTERMEDIATE RELAY SYSTEM WITH
SEPARATE POWER CONSIDERATIONS MUST BE PROVIDED. FAILURE TO FOLLOW THIS WARNING
COULD RESULT IN SERIOUS INJURY OR DEATH OR DAMAGE TO EQUIPMENT.
2.2 GENERAL
Radio controlled material handling equipment operates in several directions. Cranes, hoists, lifting devices and
other material handling equipment can be large, and operate at high speeds. Quite frequently, the equipment is
operated in areas where people are working in close proximity to the material handling equipment. The operator
must exercise extreme caution at all times. Workers must constantly be alert to avoid accidents. The
following recommendations have been included to indicate how careful and thoughtful actions may prevent inju-
ries, damage to equipment, or even save a life.
2.3 PERSONS AUTHORIZED TO OPERATE RADIO
CONTROLLED CRANES
Only properly trained persons designated by management should be permitted to operate radio controlled
equipment.
Radio controlled cranes, hoists, lifting devices and other material handling equipment should not be operated by
any person who cannot read or understand signs, notices and operating instructions that pertain to the equipment.
Radio controlled equipment should not be operated by any person with insufficient eyesight or hearing or by any
person who may be suffering from a disorder or illness, is taking any medication that may cause loss of
equipment control, or is under the influence of alcohol or drugs.

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 8 of 69
2.4 SAFETY INFORMATION AND RECOMMENDED TRAINING
FOR RADIO CONTROLLED EQUIPMENT OPERATORS
Anyone being trained to operate radio controlled equipment should possess as a minimum the following
knowledge and skills before using the radio-controlled equipment.
The operator should:
have knowledge of hazards pertaining to equipment operation
have knowledge of safety rules for radio-controlled equipment
have the ability to judge distance of moving objects
know how to properly test prior to operation
be trained in the safe operation of the radio transmitter as it pertains to the crane, hoist, lifting device or
other material handling equipment being operated
have knowledge of the use of equipment warning lights and alarms
have knowledge of the proper storage space for a radio control transmitter when not in use
be trained in transferring a radio control transmitter to another person
be trained how and when to report unsafe or unusual operating conditions
test the transmitter emergency stop and all warning devices prior to operation; testing should be done
on each shift, without a load
be thoroughly trained and knowledgeable in proper and safe operation of the crane, hoist, lifting device,
or other material handling equipment that utilizes the radio control
know how to keep the operator and other people clear of lifted loads and to avoid “pinch” points
continuously watch and monitor status of lifted loads
know and follow cable and hook inspection procedures
know and follow the local lockout and tagout procedures when servicing radio-controlled equipment
know and follow all applicable operating and maintenance manuals, safety procedures, regulatory
requirements, and industry standards and codes
The operator shall not:
lift or move more than the rated load
operate the material handling equipment if the direction of travel or function engaged does not agree
with what is indicated on the controller
use the crane, hoist or lifting device to lift, support or transport people
lift or carry any loads over people
operate the crane, hoist or lifting device unless all persons, including the operator, are and remain clear
of the supported load and any potential pinch points
operate a crane, hoist or lifting device when the device is not centered over the load
operate a crane, hoist or lifting device if the chain or wire rope is not seated properly in the sprockets,
drum or sheave
operate any damaged or malfunctioning crane, hoist, lifting device or other material handling equipment

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 9 of 69
change any settings or controls without authorization and proper training
remove or obscure any warning or safety labels or tags
leave any load unattended while lifted
leave power on the radio-controlled equipment when the equipment is not in operation
operate any material handling equipment using a damaged controller because the unit may be unsafe
operate manual motions with other than manual power
operate radio-controlled equipment when low battery indicator is on
WARNING
THE OPERATOR SHOULD NOT ATTEMPT TO REPAIR ANY RADIO CONTROLLER. IF ANY PRODUCT
PERFORMANCE OR SAFETY CONCERNS ARE OBSERVED, THE EQUIPMENT SHOULD IMMEDIATELY BE
TAKEN OUT OF SERVICE AND BE REPORTED TO THE SUPERVISOR. DAMAGED AND INOPERABLE
RADIO CONTROLLER EQUIPMENT SHOULD BE RETURNED TO ARC FOR EVALUATION AND REPAIR.
FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO
EQUIPMENT.
2.5 TRANSMITTER UNIT
Transmitter switches should never be mechanically blocked ON or OFF. When not in use, the operator should
turn the transmitter OFF. A secure storage space should be provided for the transmitter unit, and the transmitter
unit should always be placed there when not in use. This precaution will help prevent unauthorized people from
operating the material handling equipment.
Spare transmitters should be stored in a secure storage space and only removed from the storage space after
the current transmitter in use has been turned OFF, taken out of the service area and secured.
2.6 PRE-OPERATION TEST
At the start of each work shift, or when a new operator takes control of the crane, operators should do,
as a minimum, the following steps before making lifts with any crane or hoist:
Test all warning devices.
Test all direction and speed controls.
Test the transmitter emergency stop.
2.7 BATTERIES
WARNING
KNOW AND FOLLOW PROPER BATTERY HANDLING, CHARGING AND DISPOSAL PROCEDURES.
IMPROPER BATTERY PROCEDURES CAN CAUSE BATTERIES TO EXPLODE OR DO OTHER SERIOUS
DAMAGE. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND
DAMAGE TO EQUIPMENT.

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 10 of 69
2.8 USED SYMBOL DESCRIPTION
Danger electric shock risk
Equipment Recycling: The production and operation of this equipment requires the
recycling and utilization of natural resources. There are substances that are harmful to
the environment or human health. To avoid the release of such substances into the
environment and to reduce the use of natural resources, it is recommended that you
recycle this product through a suitable system to ensure that most of the materials are
properly recycled or reused.
Earth; ground protection against electric shock in case of a fault, or the terminal of a
protective earth (ground) electrode.
2.9 METHOD CLEANING PRODUCTS
Wipe the dust, smudges and stains on the surface of the product with a damp, lint-free cloth.
2.10 PRODUCT MAINTENANCE
Do not drop or damage the controller. Drop controllers can cause delicate electronic parts to loosen and affect
the use of functions.
2.11 POWER SUPPLY
The POWER front end must be equipped with circuit breaker as the way to power off the product.
2.12 ENVIRONMENT CONDITION
Outdoor use.
Altitude up to 2000 Meters (6500 feet).
Maximum Relative Humidity 90%.
MAINS supply voltage fluctuations up to ±10%.
OVERVOLTAGE CATEGORY II.
WET LOCATION, applicable.
Applicable POLLUTION DEGREE 2 of the intended environment (in most cases).

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 11 of 69
3. General System Information
3.1 Transmitter
3.1.1 Flex 2JB-HRX Joystick Transmitter Illustration
1. PB1 / SW1
2. PB2 / SW2
3. PB3 / SW3
4. PB4 / SW4
5. PB5
6. PB6
7. PB7 / SW7
8. System Status LED
9. Battery Charging LED
10. Function LED-A
11. Function LED-B
12. Infrared Sensors
13. Left Joystick (LX and LY)
14. Right Joystick (RX and RY)
15. Function Dipswitch-1 (reserved)
16. Function Dipswitch-2
17. Plugin Charging Port
18. START button
19. STOP button
20. System Information
17
19
18
16
15
20
1
2
4
3
13 14
5 6
12
89
7
10 11

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 12 of 69
3.1.2 Flex 2JB-HRX Lever Transmitter Illustration
1. PB1 / SW1
2. PB2 / SW2
3. PB3 / SW3
4. PB4 / SW4
5. PB5
6. PB6
7. PB7 / SW7
8. System Status LED
9. Battery Charging LED
10. Function LED-A
11. Function LED-B
12. Infrared Sensors
13. Lever-1 (L1)
14. Lever-2 (L2)
15. Lever-3 (L3)
16. Lever-4 (L4)
17. Function Dipswitch-1 (reserved)
18. Function Dipswitch-2
19. Plugin Charging Port
20. START button
21. STOP button
22. System Information
1
2
4
3
5 6
13
14
16
15
12
19
21
20
18
17
22
89
10 11
7

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 13 of 69
3.2 Receiver
3.2.1 External Illustration
1. External Antenna Port (optional) 6. System Information
2. Power LED Indicator 7. Cord Grip
3. Status LED Indicator 8. Infrared Sensors
4. LCD Screen 9. Gore-Tex Vent
5. Remote Pairing and 10. Mounting Bracket (optional)
Programming Buttons

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 14 of 69
3.2.2 Internal Illustration
1. Power and Status LED Indicators 4. Infrared Sensors
2. RF Transceiver Board 5. LCD Screen
3. CAN Bus Connector 6. Remote Pairing and
Programming Buttons
2
4
1
5
6
3

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 15 of 69
4. Function Settings
4.1 Transmitter
4.1.1 Transmitter Firmware Version
1) Reset the STOP button (Status LED turned green for up to 2.0 seconds, transmitter
power on).
2) Press and hold both PB5 and PB6 at the same time for up to 3.0 seconds (Status
LED blinks orange). Let go of both PB5 and PB6 when LED-A and LED-B turned red.
3) Entered programming mode with Status LED displays 1x orange blink for firmware
version, remote pairing and IR programming. 2x orange blinks for transmitter
channel programming, 3x orange blinks for PB1~PB7 function programming, 4x
orange blinks for frequency range indication, 5x orange blinks for TAC programming.
4) Press and hold both PB5 and PB6 at the same time for up to 3.0 seconds (LED-A and
LED-B turned red). Let go of both PB5 and PB6 when Status LED turned orange.
5) The Status LED now displays the transmitter firmware version with red, green and
orange blinks.
6) Exit firmware version mode by pressing down the STOP button (transmitter power off).
PB
5
PB6

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 16 of 69
4.1.2 Transmitter Channel Programming
A. Unassigned Channel Scheme (no preset system channel)
When both transmitter and receiver is set to unassigned channel scheme (no
preset channel), the system automatically search and lock onto a free and
uninterrupted channel at every transmitter startup. Pitch & Catch configuration
“cannot” set to unassigned channel scheme.
1) Reset the STOP button (Status LED turned green for up to 2.0 seconds, transmitter
power on).
2) Press and hold both PB5 and PB6 at the same time for up
to 3.0 seconds (Status LED blinks orange). Let go of both
PB5 and PB6 when LED-A and LED-B turned red.
3) Entered programming mode with Status LED displays 1x
orange blink for firmware version, remote pairing and IR
programming. 2x orange blinks for transmitter channel
programming, 3x orange blinks for PB1~PB7 function
programming, 4x orange blinks for frequency
range indication, 5x orange blinks for TAC programming.
4) Select transmitter channel programming mode (Status LED 2x orange blinks) by
press and hold PB6 for up to 3.0 seconds (LED-B turned red). Let go PB6 when
Status LED turns to 2x orange blinks.
5) Enter transmitter channel programming mode by press and hold both PB5 and
PB6 at the same time for up to 3.0 seconds (LED-A and LED-B turned red). Let
go of both PB5 and PB6 when Status LED displays the current transmitter channel
setting. A green blink represents the tens (+10), a red blink represents the units
(+1) and constant orange represents unassigned channel. For example, 1x green
blink followed by 5x red blinks is channel 15.
6) Change transmitter channel to “unassigned channel” by press and hold both PB5
and PB6 at the same time (Status LED displays constant orange for unassigned
channel). Make sure constant orange is shown on the Status LED before
proceeding to the next step.
7) Transfer the unassigned channel setting to the receiver by pressing the green
START button until the Status LED turns to constant green (transfer complete).
Turn off the transmitter power if constant green is not shown on the Status LED
after more than 5.0 seconds (transfer incomplete); the transmitter will revert back
to its previous channel setting. Make sure the receiver power is turned on and
within the operating distance during the entire process. When transmitter is set to
“unassigned channel”, the receiver must also set to “unassigned channel” in
order for the entire system to work.
8) Exit transmitter channel programming mode by pressing down the STOP button
(transmitter power off).
PB5
PB6

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 17 of 69
B. Assigned Channel Scheme (preset system channel)
Both transmitter and receiver is assigned with a matching preset channel (channel
01~62). Pitch & Catch configuration “must” set to assigned channel scheme.
1) Reset the STOP button (Status LED turned green for
up to 2.0 seconds, transmitter power on).
2) Press and hold both PB5 and PB6 at the same time
for up to 3.0 seconds (Status LED blinks orange).
Let go of both PB5 and PB6 when LED-A and LED-B
turned red.
3) Entered programming mode with Status LED displays 1x
orange blink for firmware version, remote pairing and IR
programming. 2x orange blinks for transmitter channel programming, 3x orange
blinks for PB1~PB7 function programming, 4x orange blinks for frequency range
indication, 5x orange blinks for TAC programming.
4) Enter transmitter channel programming mode by press and hold both PB5 and PB6 at
the same time for up to 3.0 seconds (LED-A and LED-B turned red). Let go of both
PB5 and PB6 when Status LED displays the current transmitter channel setting. A
green blink represents the tens (+10), a red blink represents the units (+1) and
constant orange represents unassigned channel. For example, 1x green blink followed
by 5x red blinks is channel 15.
5) Change transmitter channel by pressing PB5 for up to 2.0 seconds (Status LED turns
red during each press) to increment the units (+1) and press PB6 for up to 2.0
seconds (Status LED turns green during each press) to increment the tens (+10). For
example, press PB6 two times and then PB5 four times is channel 24 (Status LED
blinks 2 greens and 4 reds). Make sure each button press does not exceed 3.0
seconds after release. Also make sure the newly selected channel indication is
shown on the Status LED before proceeding to the next step.
6) Transfer the newly selected channel to the receiver by pressing the green START
button until the Status LED turns to constant green (transfer complete). Turn off the
transmitter power if constant green is not shown on the Status LED after more than
5.0 seconds (transfer incomplete); the transmitter will revert back to its previous
channel setting. Make sure the receiver power is turned on and within the operating
distance during the entire process. The transmitter and receiver channel must be the
same in order for the entire system to work.
7) Exit transmitter channel programming mode by pressing down the STOP button
(transmitter power off).
Important Note:
Step 6 illustrated above is strictly required if you are intending to change the entire system
channel (both transmitter and receiver). The entire system no longer works if step 6 is skipped
because the transmitter and receiver channels are now different (new vs. old). In this case you
would have to redo step 1~4 and step 6 to transfer the newly selected transmitter channel to
the receiver.
PB5
PB6

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 18 of 69
4.1.3 Remote Pairing
A. Transmitter-to-Transmitter Pairing:
1) Reset the STOP button on both transmitters (Status LED turned green for up to 2.0
seconds, transmitter power on).
2) Press and hold both PB5 and PB6 at the same time for
up to 3.0 seconds on both transmitters (Status LED blinks
orange). Let go of both PB5 and PB6 when LED-A and
LED-B turned red.
3) Entered programming mode with Status LED displays 1x
orange blink for firmware version, remote pairing and IR
programming. 2x orange blinks for transmitter channel
programming, 3x orange blinks for PB1~PB7 function programming, 4x orange blinks
for frequency range indication, 5x orange blinks for TAC programming.
4) Press and hold both PB5 and PB6 at the same time for up to 3.0 seconds (LED-A and
LED-B turned red). Let go of both PB5 and PB6 when Status LED turned orange.
5) The Status LED now displays the transmitter firmware version with red, green and
orange blinks.
6) Output data (original transmitter) by first press and hold the green START button for
up to 1.0 second and then press and hold PB6 (Status LED off).
7) Receive data (new transmitter) by first press and hold the green START button for
up to 1.0 second and then press and hold PB5 (Status LED blinks green).
8) The pairing is completed when the Status LED on the new transmitter (receiving
data end) turns to constant green while the two buttons on both transmitters are still
pressed down. Let go all buttons when done.
9) Exit remote pairing mode by pressing down the STOP button (transmitter power off).
→
Output data – original transmitter Receive data – new transmitter
(press and hold START and then PB6) (press and hold START and then PB5)
Press
Press
Press
Press
PB5
PB6

Flex 2JB-HRX Instruction Manual
October 2022 v1.1
Page 19 of 69
B. Receiver-to-Transmitter Pairing:
JP8 Open Method (require pressing the PAIRING button on receiver):
1) Reset the STOP button on both transmitters (Status LED turned green for up to 2.0
seconds, transmitter power on).
2) Press and hold both PB5 and PB6 at the same time for up to
3.0 seconds on both transmitters (Status LED blinks orange).
Let go of both PB5 and PB6 when LED-A and LED-B turned
red.
3) Entered programming mode with Status LED displays 1x
orange blink for firmware version, remote pairing and IR
programming. 2x orange blinks for transmitter channel
programming, 3x orange blinks for PB1~PB7 function programming, 4x orange blinks
for frequency range indication, 5x orange blinks for TAC programming.
4) Press and hold both PB5 and PB6 at the same time for up to 3.0 seconds (LED-A and
LED-B turned red). Let go of both PB5 and PB6 when Status LED turned orange.
5) The Status LED now displays the transmitter firmware version with red, green and
orange blinks.
6) Output data (receiver) by press and hold the PAIRING button on the receiver cover.
7) Receive data (transmitter) by press and hold PB5 (Status LED blinks green).
8) The pairing is completed when the Status LED on the transmitter (receiving data
end) turns to constant green while PB5 on transmitter and PAIRING button on
receiver are still pressed down. Let go all buttons when done.
9) The receiver MAIN outputs must be deactivated during remote pairing.
10) Exit remote pairing mode by pressing down the STOP button (transmitter power off).
→ →
Set JP8 to “Open” Output data – receiver Receive data – transmitter
(press and hold the PAIRING button) (press and hold PB5)
Pres
s
PB5
PB6
Table of contents
Other ARC Remote Control manuals
Popular Remote Control manuals by other brands

Panasonic
Panasonic CZ-RWSD2U installation instructions

ChronoRemoteControl
ChronoRemoteControl SLH Series Programming manual

Hitachi
Hitachi PC-AWR Installation and operation manual

Aerotec
Aerotec Nano Shutter user guide

Multiplex
Multiplex PROFI CAR 403 operating instructions

FUTABA
FUTABA Mega Tech 3PK instruction manual