ArianaSpas S-Shape MS-45T6SB-30K User manual

© ArianaSpas www.arianaspas.com
2 | P a g e
Disclaimer
This machine is meant to be used by trained personnel only. Improper usage of this machine
can cause injury or death.
oPlease read the instructions in detail and keep them nearby for further reading and
consultation.
oPlease follow the instructions to set-up and operate the machine correctly.
oPlease do not remove and modify any accessories of the machine.
oThis machine should only be opened by trained professionals.
oIf there are any issues with the machine, please stop using it and contact us for a
resolution.
oThis device does not treat medical ailments or disease. For any medical issues, please
contact your physician.
Contents:
•Main Machine x 1
•Suction and RF Facial Slimming Handle x 1
•EMS and EL (Electroporation) Facial Anti-aging Handle x1
•Ultrasound Cavitation and RF Body Shape Handle x 1
•Suction and RF Body Sculpture Handle x 1
•Big laser paddles x 6
•Small laser paddles x 2
•Holder x 1
•Power Supply Cord ( Both 110v and 220v voltage (frequency: 50/60Hz) version are
available. Also we stock the USA, UK, AU, EU plug to suit for the country all over the
world.) x 1

© ArianaSpas www.arianaspas.com
3 | P a g e
Warranty & Support
Most issues are due to incorrect setting. If you are experiencing an issue please make a
Small Cell Phone Video and send via text to (571) 418 4858.
One of our technicians will review it and advise with a solution.
Your Ariana Spa Supplies-branded hardware product
materials and workmanship for a period of ONE (1) YEAR from the date of original retail purchase
during the Warranty Period, Ariana Spa Supplies, at its option will (1) repair the Product at no charge
using new parts or parts that are equivalent to new in performance and reliability, or (2) exchange the
Product with a product with equivalent functionality formed from new and/or previously used parts that
are equivalent to new in performance and reliability or with your consent, a product that is at least
functionally equivalent to the product it replaces. This warranty excludes normal depletion of
consumable parts such as batteries unless failure has occurred due to a defect in materials or
workmanship and, damage resulting from abuse, accident, modifications, unauthorized repairs or other
causes that are not defects in materials and workmanship.
Ariana Spa Supplies does not warrant, represent or undertake that it will be able to repair or replace any
Product under this warranty without risk to and / or loss of information and / or data stored on the
Product. In no event shall Ariana Spa Supplies be liable fo
purchase cannot be regarded as being caused by Ariana Spa breach of these warranty terms;
or (b) losses caused by the loss of data or loss of profits or benefits.
Any limitations of liability in this warranty document shall not apply to (i) death or personal injury
pursuant to any mandatory law on product liability; (ii) fraud or fraudulent misrepresentation; (iii)
intentional misconduct or gross negligence; (iv) or a culpable breach of major contractual obligations. A
damages claim based on a breach of major contractual obligations or gross negligence will be limited to
foreseeable damage typical for the sale contract concerned.
To obtain warranty service, contact Ariana Spa Supplies at Ariana Spa Supplies, 42715 Chisholm Drive,
Broadlands, VA 20148. Customers are responsible for shipping charges to get the item back to us and for
return shipping cost once the item is repaired or replace.

© ArianaSpas www.arianaspas.com
4 | P a g e
Table of Contents:
Table of Contents:
1. Introduction to Manual...........................................................................................................................5
1.1 Purpose
1.2 Legend
2. Medical Safety......................................................................................................................................... 6
2.1. Contraindications
2.2. Precautions
2.3. Client Safety
3. Features ....................................................................................................................................................8
4. Operation Instructions..............................................................................................................................9
4.1 Function Selection
4.2 30K & RF
4.3 Body Vacuum & RF
4.4 EMS&EL
4.5 Face Vacuum & RF
4.6 Laser Pads
5. Technical Parameters............................................................................................................................ 23
6. Restrictions on Use ................................................................................................................................24
7. Precautions ............................................................................................................................................24
8. Troubleshooting & Solutions..................................................................................................................25
9. FAQs.......................................................................................................................................................26
10. Operational Diagrams28

© ArianaSpas www.arianaspas.com
5 | P a g e
1.
Introduction to Manual
1.1 Purpose
This manual provides a description of the system components, its
controls and displays, instructions for its operation, and other equipment information
relevant to the user.
Warning: Do Not operate this machine before reading thismanual thoroughly. In
addition to this manual, additional training may be available.
1.2 Legend
Note: This Indicates important information
Warning: Necessary and vital information for the safety of the patient and/or user.
All procedures are broken down by numbered steps. Steps must be completed in the sequence
they are presented.
Bulleted lists indicate general information about a particular function or procedure. They do not
imply a sequential procedure.

© ArianaSpas www.arianaspas.com
6 | P a g e
2.
Medical Safety
2.1. Contraindications
This machine is not intended for use in patients with:
o
Open wounds or lesions on the face and/or neck
o
Severe or cystic acne on the face and/or neck
2.2. Precautions
The cavitation vacuum RF micro current photon machine should not be used on clients that
have the following:
o
Mechanical implants
o
Dermal fillers
o
Implanted electrical devices in the face and/or neck
o
Metal stents in the face and/or neck area
o
Existing keloid(s)
o
The following areas should be avoided during treatment:
o
Thyroid gland, thyroid cartilage and trachea
o
Major blood vessels
o
The cavitation vacuum RF microcurrent photon machine has not been evaluated
for use in the following client populations:
o
Pregnant or breast-feeding women
o
Children
o
Those with the following disease(s):
•
A hemorrhagic disorder or hemostatic dysfunction
•
An active systemic or local skin disease that may alter wound healing
•
Herpes simplex
•
Autoimmune disease
•
Diabetes
•
palsy

© ArianaSpas www.arianaspas.com
7 | P a g e
2.3. Client Safety
Warning: This machine is to be used only by trained and qualified professionals.
Warning: Cavitation vacuum RF micro current photon machine should not be used on a
eyes or in a location or technique where ultrasound energy can reach the eye.
Warning: If any problems occur during system operation - lift the transducer off the
skin, press the PAUSE button to completely halt system operation.

© ArianaSpas www.arianaspas.com
8 | P a g e
3.
Features
o
This is a painless treatment that is both safe and effective.
o
This is a non-surgical, non-invasive process.
o
The treatments do not have any adverse side effects and do not interfere with daily life.
o
Firms the arms, legs, thighs, buttocks, waist, back, abdominal muscles to reshape the body.
o
Provides feelings of: soothing, decompression and pain relief (such as joint pain, sciatica).
o
Promotes the regular mechanical aerobic exercise of skin tissue to rapidly relieve stress and remove
fatigue.
•Firms, lifts and compacts facial skin by promoting cellular metabolism. Up to 100% more
collagen and may be available to help improve skin elasticity.

© ArianaSpas www.arianaspas.com
12 | P a g e
(referred scope: 2-8)
30K Modes
M1 is the Consecutive Mode, when it starts, the ultrasonic works in a consecutive way,
which is suitable for those who have thick level of fat and accumulated fat.
M2 is the Intermittent Mode, when it starts, the ultrasonic works in an intermittent way, which is
suitable for those who use it for the first time or who have lower adaptive capacity.
RF Parameter Adjustment
RF Energy Adjustment (referred scope: 3-8)
RF Energy +/-
RF Modes
NOR is the set mode. The red LED is on and the energy of the handle is at the set level and stay at the

© ArianaSpas www.arianaspas.com
13 | P a g e
set level after turning on the device.
PRO is the smart mode. The temperature goes up slowly to the set energy and red LED is on after the
probe comes in full contact with theskin.
Start/Stop
4.3 Detailed Operation: Body Vacuum & RF
Select to go to the interface below
Vacuum&RF Working Time (one area is advised to be
operated for around 20 min at a time)
Return
Home

© ArianaSpas www.arianaspas.com
14 | P a g e
Time +/-
RF Parameter Adjustment
Energy Display (referred scope: 3-8)
RF Energy +/-
RF Modes
NOR is the set mode. The red LED is on and the energy of the handle is at the set
level and stay at the set level after turning on the device.
PRO is the smart mode. The temperature goes up slowly to the set energy and red LED is on after the
probe comes in full contact with theskin.
Suction time adjustment, it is the suction time during the suction&release process
(reference: 5-10. The bigger the number is, the longer the suction time will be. The suction time is
advised to be longer than the release time).

© ArianaSpas www.arianaspas.com
15 | P a g e
Suction Level Display: The pointer will rotate according to the
specific suction level.
Suction Time Display
Suction Time +/-
Release time adjustment, it is the release time during the
suction&release process (reference: 0-
ndle is in the constant
suction condition. The constant suction mode is suitable for those with heavy moisture in body, obesity,
clogged and those who need effective detox, weight loss, scraping and shaping. The suction&release mode is
suitable for body detox, massage, relaxing muscle, relieving muscle, dredging channels and collateral and
tightening&shaping).
Release Level
Time +/-
Return
Home
Start/Stop
The knob is to adjust the suction Level. Rotate it to the right to increase
the suction level and rotate it to the left to decrease the suction level.
Release
Time

© ArianaSpas www.arianaspas.com
19 | P a g e
Time +/-
RF Parameter Adjustment
RF Energy (reference: 3-8)
Energy +/-
RF Modes
NOR is the set mode. The red LED is on and the energy of the handle is at the set level and stay at
the set level after turning on the device.
PRO is the smart mode. The temperature goes up slowly to the set energy and red LED is on after
the probe comes in full contact with the skin.
Suction time adjustment, it is the suction time during the suction&release process
(reference: 5-10. The bigger the number is, the longer the suction time will be. The suction time is advised to be
longer than the release time).

© ArianaSpas www.arianaspas.com
20 | P a g e
Suction Level Display: The pointer will rotate according to the specific suction level.
Time +/-
Release time adjustment, it is the release time during the suction&release process
(reference: 0-
andle is in the constant suction condition. The
constant suction mode is suitable for those with heavy moisture in body, obesity, clogged and those who need
effective detox, weight loss, scraping and shaping. The suction&release mode is suitable for body detox,
massage, relaxing muscle, relieving muscle, dredging channels and collateral and tightening&shaping).
Release Level
Start/Stop
The knob is to adjust the suction Level. Rotate it to the right to increase the suction level and
rotate it to the left to decrease the suction level.
Suction
Time
Release
Time
Time
+
/
-
Return
Home
Table of contents
Other ArianaSpas Personal Care Product manuals