- 2 -
Wiring procedure:
First, wire the control panel (power down) to the siren as shown, before
connecting the battery. When the battery is connected for the first ti e, the
siren will give a short beep. The siren cannot be activated until all inputs (input
power and hold-off voltages) are correct. The siren will be activated if the
Jumpers:
GND
GND 4700 W
4700 W
4700W33W
0 V
LED
Isolated
Isolated
EOL
-
Tamper Loop (T5/T6)
Tamper
Tamper
-
Ex-factory
Beacon
Terminal 1
0 V
Siren Timing
Siren
Terminal 2
14 4420 999-1
© 2000 Interlogix BV. All rights reserved. ISO certified
Technical data:
Supply voltage: 10.0 V - 14.5 VDC
Standby current: 40 A (typical)
Operating current: 350 A (typical) (incl. beacon)
Sound output: 114 dB at 1 ;
85 dB at 3
Frequency sweep: 0.58 - 3 kHz
Operational ti er: 20' (ex-factory)
Working te perature: -25°C to +55°C
Weight: 1 kg
Di ensions: 300 x 210 x 55
Standards: According to: IS 199
Reco ended battery:
- Lead acid: (optional) Type 12 V - 1.2 Ah
Load voltage in 13.6, ax 14.2 VDC
- NiCd: (ex-factory) Type 6 V - 280 Ah
Load current 20 A (typical)
Ta per: 28 VDC; ax. 100 A
Beacon:
Operating current: 110 A
Light output: 100.000 peak lu ens
Life ti e: 1.000.000 flashes
Flash rate: 60/ inute
Spike suppression network: Standard fitted
20
minutes
Standard ex- actory settings:
Ex-
factory
J10
Red = Alarm Green = OK
EOL
Active
Active
Cut J8 & J9
Red Green
12345678 910
11
-
+
+
+
-
-
1K
1K
Typical single-siren wiring for Irish panels:
Beacon
Siren
+V
Tamper
GND
-Ve
tamper
return
A X.
supply
EXT. bell
INT. bell
J8
J9
2-siren wiring configuration:
J10
input power is re oved or drops significantly or if the siren hold-off voltage
is re oved.
When using an Aritech control syste or any other control syste which
requires 4k7 end of line resistor, cut J8 to use built in end of line feature.