Armedica AMTM-700 Series User manual

This manual has been prepared for the owners and operators of
the ARMEDICA™ AMTM-700 Series Parallel Bars and
contains installation instructions, precautionary instructions
and maintenance procedures for the following model numbers:
AMTM-700, AMTM-702, AMTM-703,
AMTM-705, AMTM-706, AMTM-706HD


This User's Manual is for the following AM-700 series Parallel platforms only
AMTM-700 - Electric platform 10'x43"
AMTM-702 - Electric platform 7'x43"
AMTM-703 - Electric platform 15'x43"
AMTM-705 - Electric bariatric platform 10'x49-1/2"
AMTM-706 - Electric bariatric platform 10'X49-1/2"
Table of Contents
Models covered in manual and table of contents 2
Symbols and Indicators 3
Definitions 4
Assembly and Installation 6
Operating instructions 9
Maintenance 10
Cleaning 11
Technical specifications 12
Parts list and Drawings 13
Maintenance Log 23
Warranty information 24
IMPORTANT: Do not use this manual to reference instructions, requirements or
specifications for any product other than those listed in this manual.
Equipment damage, void of warranty and personal injury may occur.
WARNING: Read and understand this user's manual before installing or using this
equipment.
Failure to follow operating and maintenance instructions could result in equipment
damage or personal injury.
2

SYMBOLS and INDICATORS
WARNING: Follow safe lifting procedures and precautions.
ATTENTION: Important information or instructions.
Type B Applied part: An Applied Part complying with the specified requirements to
provide protection against electric shock, particularly regarding allowable patient
leakage current and patient auxiliary current.
WARNING: Identifies electrical shock hazard.
This platform is equipped with a protective earth ground. This device may only be
connected to a power source with a protectively earthed ground.
WARNING: Read and understand the operating instructions listed in this manual
before installing or using this equipment.
Failure to follow manufacturer's operating instructions could result in equipment
damage or personal injury.
Alternating Current
3

DEFINITIONS
The AMTM-700 Series Electric Parallel Bars are a Class 1 medical device in
respect to the use of an earthed ground as a means of protection against electric
shock.
Intended use: The AMTM-700 Series Electric Parallel Bars is intended for
medical rehabilitation purposes and, to be used in conjunction with other forms
of exercise, as a stability aid in standing, walking and balance exercises.
Patient: Any person cleared by a doctor or physical therapist currently using this
device as an exercise platform under the direction and supervision of a qualified
operator.
Operator: Any person/persons who has been trained, qualified and authorized by
the consumer or responsible organization to operate this platform.
Service Technician: Any person/persons authorized by Armedica Manufacturing
to perform service, component replacement or repair to the AMTM-700 Series
Electric Parallel Bars.
CAUTION: A patient is not intended to operate this device in any
way. The AMTM-700 series Electric Parallel Bars shall be
operated by trained, qualified and authorized personnel ONLY.
CAUTION: Using this device in a manor inconsistent with its
labeling will void warranty and, damage to device or personal
injury may occur.
CAUTION: This device is not suitable for use in an oxygen rich
environment or in the presence of flammable anesthetics. Fire or
explosion may occur.
4

DEFINITIONS CONTINUED
Duty Cycle: The ratio of time the device can be in a state of continuous actuation
(moving) and rest. Noted in units of minutes as ON/OFF. The Duty Cycle of this
device is rated for 1(one) minute on / 9(nine) minutes off.
Electrical power source: This platform is intended to be connected to an external
120V , 8 Amp (peak), 60Hz electrical power source.
Applied part: An applied part is one specifically intended to come into direct
contact with patient during normal use. This includes Armedica part #'s 28442,
28443, 28444, 14601, 14605, 14609, 14610 and 14615 only. Applied parts are
identified, either in this manual or directly on the part, with this symbol . (Refer
to the bill of materials on Pg. 13 for list of parts and descriptions)
Accessible Part: An Accessible Part is any part that the patient or operator may
come into direct contact with, either intentional or unintentionally, but direct
contact is not required for normal operation.
Operator Interface: The point in which the operator will input data, via momentary
push button, for actuation, memory function and device control.
WARNING: To avoid risk of electrical shock, this device must
only be connected to a supply mains with protective earth
ground.
ATTENTION: This device has been tested for Electromagnetic
capability in accordance with IEC 60601-1-2 Ed.4. It is suitable to
be used in industrial areas and hospitals. The possibility of EMC
and/or RF interference may occur in the presence of other
devices. If interference is suspected, move this device away from
other sensitive devices or contact manufacturer.
5

AMTM SERIES ELECTRIC PARALLEL BARS
ELECTRIC PARALLEL BARS INSTALLATION
ALL MODELS
1. Remove platform (item # 1, 46, 47, 51 or 52) from crate using handles attached to
mounting brackets. Set the platform on firm level floor.
For 2-piece split platforms, set both pieces on side against a solid surface while installing
connecting plates (50). Align the 2 pieces and firmly hold together. Using screws (49),
install all connecting plates in recessed pockets. After all connecting plates have been
installed, place platform on floor as directed in step 1.
2. Place the four upright columns (13) on the platform aligning the holes in the mounting
plate(15) with the screws sticking through the platform. Paying attention to and
ensuring the cable at the bottom of the column is facing outward. Tighten the mounting
bolts (14) securely.
3. Install the hand rails (30, 44 or 45) onto the adjustment tubes (4) using spacer (31),
washers x2 (32), and lock nut (35); tighten the lock nut (35), sufficiently, to eliminate any
play but not so tight that they will not pivot when adjusting the width. When necessary,
adjust the width according to the operating instructions.
4. Remove the cover plate from box (24) to allow access to inside of control stand (53).
Using nuts (21), mount the control stand (53) to the platform, threading AC mains cable
with EMI filter, 4 protective earth ground wires (green with yellow), and column motor
cables (36, 37) through appropriate holes. Ensure all protective earth grounds are
secured on the bolt pin with paint removed.
5. With screws (26) and cover plate (24) removed, connect the controller (22) per the
following instructions.
CAUTION: There are no contradictions associated with this
device. The emissions characteristics of this device make it
suitable for use in industrial areas and hospitals.
WARNING: 4 people arerequired to move this equipment.
This unit weighs in excess of 500lbs/227kg. Failure to follow safe
lifting instructions can result inserious personal injury and/or damage
to equipment.
WARNING: Read and understand this operator’s manual before
installing or using this equipment.
Failure to follow operating and maintenance instructions could result
in equipment damage or personal injury.
CAUTION: Do not lift or support by end ramps or columns. Damage t
or serious personal injury may occur
6

SCU CONTROLLER
WARNING: Do not adjust or operate this device while patient is on or
using this device. Serious personal injury and/or damage to
equipment may occur.
WARNING:
This device may only be used in a professional healthcare
facility where operators with professional medical training are
continuously available when patients are present.
WARNING: Dangerous voltage present.
Do not connect this unit to a power source before reading these
instructions. Damage to equipment and/or electrical shock may
occur.
CAUTION: All cables must be fully inserted into their appropriate
receptacles on control box and columns. Failure to do so may cause
unit malfunction and/or permanent damage to equipment.
1. TP4 Power Supply
2. TC8 Control Unit
3. EMI Filter
4. Protective Earth Ground
5. AC Mains Port
6. DC Power Supply Port
7. Operator Interface Port
8. Ferrite Filter
9. Column Motor Port 1
10. Column Motor Port 2
11. Column Motor Port 3
12. Column Motor Port 4
13. Protective Earth Terminal
1
2
3
4
5
6
7
8
9
10
11
13
12
7

CABLE CONNECTIONS
•Connect the four cables (36 & 37) (DIN8 connectors) to the appropriate column (13) and
snap coupling lock closed.
•Remove cable retainer bracket from the ports on the TC8 controller by gently prying
loose and set to the side. Replace bracket after ALL cables are connected.
•Connect the four cables (36 & 37) (DIN8 connectors) to corresponding TC8 control unit
using the Column motor ports 1, 2, 3 and 4.
•Verify that the control switch (27) cable has two ferrite filters (41) secured and insert fully in
the operator interface port.
•Verify that the TP4 supply cable is securely connected to the power supply port.
•Snap the AC mains EMI filter onto the DIN rail as shown then fully insert the AC mains cable
female end into the AC mains port of the TP4.
•Connect the protective earth ground from the EMI filter to the brass terminal on the TP4
power supply and verify ALL PE ground wires are secured properly.
•Verify that the required supply voltage indicated in this manual and on the name plate
corresponds with the supply voltage of the electrical outlet and connect the unit to the
electrical outlet. *See Technical Data section for a full list of operating conditions and
requirements.*
ATTENTION: Allow 10 seconds, after
connecting to power supply, for system to
fully initialize before attempting any
operation.
ATTENTION: Significant risk of reciprocal
interference may be posed by the presence
of this device during specific investigations
or treatments. Potential Electromagnetic or
other interference between this device and
other devices may occur. If interference is
suspected, move this device away from
sensitive devices or call the manufacturer.
CAUTION: This device is rated for 120 volts
60Htz, 6.5Amps/8Amps peak. Protective
earth ground required.
8

ELECTRIC PARALLEL BARS OPERATING INSTRUCTIONS
ALL AMTM MODELS INTENDED POSITIONS
This unit has been initialized by Armedica Manufacturing Corp. prior to shipment and
should not need to be synchronized again unless a column or control box is replaced.
If Synchronization becomes necessary, follow these steps:
INITIAL RESET FOR MOTORS
•After you have connected the control unit to the power supply for the first time, the
network is addressed, and motors must be synced.
•Press and hold BOTH the UP and DOWN arrow buttons simultaneously.
•Continue to hold the UP and DOWN buttons, all 4 columns should lower until they reach
their lowest point and, you hear a beep. If it does not beep, continue to hold the buttons
for another 3 seconds after ALL 4 columns have reached the lowest height and release.
The system is now synced and ready for use.
SETTING THE PARALLEL BAR HEIGHT
•Press the up arrow to raise the parallel bars.
•Press the down arrow to lower the parallel bars.
•The current height of the bars appears (in inches) on the display.
SAVING THE MEMORY POSITIONS
This function makes it possible to save a predetermined height setting. Four different heights
may be saved. These saved positions can be used later.
•To be performed after the synchronization procedure has been completed.
•Move the hand rails to the desired height.
•Press and hold both the UP arrow and desired memory # buttons simultaneously for
3 to 5 seconds.
•The display will flash “P#” to confirm that position has been stored to that number.
•Repeat process for other 3 memory position buttons.
WARNING: Ensure platform is clear and, there are no obstructions
under the handrails before actuating the columns to adjust height.
Serious personal injury and/or damage to equipment may occur.
Operator position
Patient position
9

USING THE MEMORY POSITIONS
•While holding down the desired memory position button, the bars will move toward the
predefined position and stop.
ADJUSTING THE WIDTH OF THE PARALLEL BARS
•Turn hand knobs, on top of each column, to release adjusting tubes and set to desired
width.
•
Make sure adjusting tube knobs are securely tightened before use.
MAINTENANCE
ARMEDICA™ Manufacturing thoroughly inspects and tests each unit to ensure that it
meets all ARMEDICA™ quality standards before it leaves the facility. To ensure the
longevity of your device, routine maintenance should be followed.
AFTER FIRST 40 HOURS OF SERVICE
Physically inspect all fasteners and hardware are properly secured
DAILY / Pre-USE
The operator should visually inspect the unit prior to each use for;
Foreign objects that may interfere with operation or create a hazard to patient
Signs of damage to unit and power cord
All hardware (nuts, bolts, etc.) is present and properly secured
All adjustments are secure
Unit functions properly
CLEANING
Use towel dampened with mild soap and water. Wipe down to remove dust, dirt and spills.
Wipe with dry towel to remove moisture
Laminated platform
Painted, plated and plastic surfaces
Use a commercial brand stainless steel cleaner to remove dirt and oil from hand rails
The laminated platform and painted or plated components should be cleaned with a
commercial disinfectant and wiped with a dry cloth to remove any biological contamination
when necessary.
WARNING: This unit is not rated for wash down, it should not be
exposed to standing or quantities of liquid.
Do not clean any electronic device with water. Electrical shock and/or
damage to electronics may occur.
CAUTION: Failure to follow recommended maintenance instructions
may cause damage to equipment, personal injury and void warranty.
10

TROUBLE SHOOTING
In the event it becomes necessary to replace the control box or a column on the AMTM-700
series, disconnect power prior to removal, and make certain the plugs are completely inserted
into the sockets prior to reconnecting power.
ELECTRIC POWERED COLUMNS DO NOT WORK.
A. Verify that proper voltage at electrical outlet and cord is plugged in.
B. Verify all cables inside the control stand and motor columns are securely plugged into their
proper receptacles.
C. Verify the hand switch cable is securely plugged into the proper control unit.
If problem still occurs, or columns become unsynchronized, please contact Armedica
Manufacturing Customer Service.
WARNING: Use only replacement parts approved by Armedica
Manufacturing. Failure to do so could result in damage to device,
increased emissions and serious injury.
WARNING: Do not alter or modify this device in any way. Altering
this device will void all warranties. Serious personal injury and/or
damage to equipment may occur.
CAUTION: Service to controls and column motors is to be done by
the manufacturer only. In the event of a column motor or control unit
failure, all 4 columns and control unit must be returned to Armedica
Manufacturing Corp. All other service or repair is to be performed by
Armedica Mfg. authorized field service personnel only. For
information, contact Armedica customer service.
WARNING: Disconnect main power to unit before opening control
stand and checking cables. Electrical shock and/or damage to
electronics may occur.
ATTENTION:
The AC Mains Cable serves as the
EMERGENCY DISCONNECT DEVICE
Do not position this device in a manner that would make it difficult to
reach the AC mains supply cable. In the event of an emergency,
unplug the AC Mains Cable from the external power supply.
11

TECHNICAL SPECIFICATIONS
ENVIROMENTAL CONDITIONS
Operating/storage temp. 5°C – 40°C / 41°F – 104°F
Humidity: 5% to 85%
Pressure/altitude: 700hPa to 1060hPa
GENERAL SPECIFICATIONS
Manufactured and assembled by
Armedica Manufacturing Corp.
Greenwood, Arkansas, USA
Tel.: (479) 996-2612
Static & Dynamic load capacity
Max 500Lbs/227Kgs per bar, not exceeding 500Lbs/227Kgs total combined load.
ELECTRICAL SPECIFICATIONS
Main input power requirements 120VAC 60Hz
Current 5,000mA / 6.5Amps
Secondary output power 29VDC / 360VA
Duty cycle 10% 1min. on / 9min. off
Model TP4-5035-001
Manufactured by:
TiMotion Technologies / TiMotion USA
1535 Center Park Drive
Charlotte, NC. 28217,
USA
Tel.: (704) 708-6924 Toll-free 1-855-235-1424
Email: sales.us@timotion.com
CAUTION: Do not throw in trash. Expected service life of this device
is approximately 10 years. Dispose of this device in accordance
with local, state and national environmental regulations. Failure to
do so may constitute a criminal act.
CAUTION: Do not exceed Maximum load capacity. Damage to unit
and/or serious injury may occur. This device is not rated for a
dynamic(moving) load. Do not use as a patient lift.
12

ITEM NO. PART NO. DESCRIPTION
AMTM MODEL #
700 702 703 705 706
114601 BD PLL COLMN PLATFORM 10' LAMNTD 1N/A N/A N/A N/A
228156 PLATE 4.5x6.5 PLL COLMN MNT PLTD 44 4 4 4
303580 SCREW FLT HD SOC M10-1.5X25 16 16 16 16 16
411601 TUBE 1x1x14GAx13 PLL RAIL ATTACH 44 4 4 4
502146 SPACER 5/16 X 3/16 ID x 1/2 OD 44 4 4 4
602093 NUT NYLOCK 8-32 44 4 4 4
713601 ROD 1/2 DIAx.75 PLUNGER 44 4 4 4
803071 KNOB W/STEM 2-1/4x3/8-16x1 44 4 4 4
903581 SCREW FLT HD SOC M6-1.0x30 16 16 16 16 16
10 03586 SCREW PAN HD PHIL 10-32x1-3/4 22 2 2 2
11 03076 CAP PLAS BLK 5/16 HEX DOME 16 16 16 16 16
12
28441
BRKT rght ADJ MNT TIMO PLL pntd 22 2 2 2
13 03574 COLUMN TL5 TiMO PLL 44 4 4 4
14 02105 NUT NYLOCK 5/16-18 16 16 16 16 16
15 12861 PLT MNT TL5 TIMO PLL PLTD 44 4 4 4
16 03576 PWR SPPLY TP4 TiMO PLL 11 1 1 1
17 18665 BUSH W/WASHER PLL PIN GUIDE PLTD 2 2 2 2 2
18 02063 SCREW HX WASHER HD #10x3/4 38 38 38 38 38
19 28040 BRKT PLL PLTFRM CONTROL STAND MNT 1 1 1 1 1
20 28434 STND CNTRL TIMO PLL PNTD 11 1 1 1
21 02100 NUT NYLOCK 1/4-20 44 4 4 4
22 03575 CONTROL TC8 TIMO PLL 11 1 1 1
23 03583 BOX 4-3/8x9-1/2x22x14GA TIMO PLL 11 1 1 1
24 03585 PLATE 6-1/4x21-15/16x14GA CVR PNTD 11 1 1 1
25 03080 RIV NUT 1/4-20 ALUMINUM 14GA 44 4 4 4
26 02538 SCREW BTN HD SOC 1/4-20x3/4 44 4 4 4
27 03577 SWTCH TDH5 TiMO PLL 11 1 1 1
28 02089 NUT NYLOCK 10-32 33 3 3 3
29 28432 BRKT lft ADJ MNT TIMO PLL pntd 22 2 2 2
30 28443 STAINLESS STEEL HND RAIL 10' TiMo PLL 2N/A N/A 2 2
31 13056 BUSHING 1/2IDx3/4ODx1-1/8 CNTRL BUSH 4 4 4 4 4
32 02165 WASHER NYLON 1/2 ID 88 8 8 8
33 03010 PLUG 1x1x14GA 88 8 8 8
34 03014 PLUG RD 1"ODx14-20 GA BLK 44 4 4 4
35 02095 NUT NYLOCK JAM 1/2-13 44 4 4 4
36 03578 CBL TEC COLUMN SHORT TiMO PLL 22 N/A N/A N/A
37 03579 CBL TEC COLUMN LONG TiMO PLL 22 4 4 4
38 02148 BUSHING INSUL NYLON PLL 44 4 4 4
39 02747 GASKET 39"x5MM EMC SHLD PLL 22 2 2 2
40 02107 SCREW PAN HD PHIL 8-32x3/4" 44 4 4 4
41 02748 FERRITE EMC FILTER TIMO PLL 22 2 2 2
42 03365 CBL 3.6M MED UL PWR CORD SCU 11 1 1 1
43 02201 CLAMP CABLE 1/4 WHITE 30 30 30 30 30
44 28442 STAINLESS STEEL HND RAIL 7' TiMo PLL N/A 2 N/A N/A N/A
45 28444 STAINLESS STEEL HND RAIL 15' TiMo PLL N/A N/A 2 N/A N/A
46 14609 BD PLL 7FT COLMN PLTFRM LAMNT N/A 1 N/A N/A N/A
47 14610 BD PLL 15' SPLIT PLATFORM LAMNT N/A N/A 1 N/A N/A
48 02200 CLAMP CABLE 3/16 BLACK N/A N/A 12 N/A N/A
49 02695 SCREW #14x1 FLT HD PHIL WD N/A N/A 16 20 20
50 12609 PLT 1/4x2x8 PLL SPLIT PLTFRM PNTD N/A N/A 4 5 5
51 14615 BD PLL 10' PLTFRM BARIAT SPLIT W/EC N/A N/A N/A N/A 1
52 14605
BD PLL COLMN PLATFORM 10' BARIATRIC N/A N/A N/A 1 N/A
53 19870
CNTRL STND CMPLT TiMO PLL ASSEMBLED 1 1 1 1 1
54
02681 SCREW PAN HD PHIL 10-32x3/4 4 4 4 4 4
55 03589
RAIL DIN 7.5MMx35MMx2-1/4 EMI MNT 1 1 1 1 1
56 03554 WIRE 74" PE GRND PLL COLUMN ASM 2 2 2 2 2
57 03555
WIRE 48" PE GRND PLL COLUMN ASM 2 2 2 2 2
58 02078
SCREW PAN HD PHIL 10-32x3/8 4 4 4 4 4
59 02493
TERM RING INSUL #10 STUD 22-18 AWG 4 4 4 4 4
60 02750
FILTER EMI 10A TiMo PLL 1 1 1 1 1
13

84" to 180"
VARIES BY MODEL
27"-53"
HEIGHT ADJUSTMENT
WIDTH ADJUSTMENT
LOCKING KNOB
43"
STANDARD
49-1/2"
BARIATRIC
15" to 29"
STANDARD
21" to 35"
BARIATRIC
PATIENT
HAND RAIL
OPERATOR INTERFACE
SWITCH
AMTM-700 SERIES
DIMENSIONS & ADJUSTMENT SPECIFICATIONS
14

1
46
47
51
52
30
44
45
8
33
4
29
12
53
34
13
36
37
21
31
32
35
15
2
9
14
11
7
3
6
5
40
AMTM-700 SERIES
ELECTRIC PARALLEL BARS
15

19
18 58
43
17
56
57
AMTM-700 SERIES
ELECTRIC PARALLEL BARS
BOTTOM VIEW
16

23
20
24
26
25
10
54
22
16
27
28
39
60
41
55
AMTM-700 SERIES
CONTROL STAND
17

49 50
51
47
AMTM SERIES
SPLIT PLATFORM WITH END CONTROL
18

AM-714
ABDUCTION BOARD
4
3
2
1
1
2
AM-715
BALANCE BEAM
ITEM NO.
PART NUMBER
DESCRIPTION
QTY.
1
14603A
BD PLL ABDUCTION 3/4X5X94
1
2 18667
BRKT YOKE PLL BD PIN PLTD
2
3 02044
SCREW HX HD CAP 1/4-20x1-1/4
2
4 02084
NUT NYLOCK JAM 1/4-20
2
ITEM NO.
PART
NUMBER
DESCRIPTION
QTY.
1
14604A
BD PLL BAL BEAM 2-1/2X5X80
1
2
13003A
SCREW 3/-16x3 MODIFIED 2-3/8 PIN
2
19
This manual suits for next models
6
Table of contents
Other Armedica Medical Equipment manuals

Armedica
Armedica AM-BA Series User manual

Armedica
Armedica AM-SX Series User manual

Armedica
Armedica AM-BA Series User manual

Armedica
Armedica AM-SX Series User manual

Armedica
Armedica AM-700 Series User manual

Armedica
Armedica AM Series User manual

Armedica
Armedica AM Series User manual

Armedica
Armedica AM-702 User manual
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual