manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Atlantis
  6. •
  7. Bathroom Fixture
  8. •
  9. Atlantis FX-NTRB User manual

Atlantis FX-NTRB User manual

This manual suits for next models

1

Other Atlantis Bathroom Fixture manuals

Atlantis Quub User manual

Atlantis

Atlantis Quub User manual

Atlantis Linea Quattro Series User manual

Atlantis

Atlantis Linea Quattro Series User manual

Atlantis 1930 User manual

Atlantis

Atlantis 1930 User manual

Atlantis EASYTILE II User manual

Atlantis

Atlantis EASYTILE II User manual

Popular Bathroom Fixture manuals by other brands

Kohler Mira Sport Max J03G Installation and user guide

Kohler

Kohler Mira Sport Max J03G Installation and user guide

Moen 186117 Series installation guide

Moen

Moen 186117 Series installation guide

Hans Grohe Raindance Showerpipe 27235000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Raindance Showerpipe 27235000 Instructions for use/assembly instructions

Signature Hardware ROUND SWIVEL BODY SPRAY 948942 Install

Signature Hardware

Signature Hardware ROUND SWIVEL BODY SPRAY 948942 Install

fine fixtures AC3TH installation manual

fine fixtures

fine fixtures AC3TH installation manual

LIXIL HP50 Series quick start guide

LIXIL

LIXIL HP50 Series quick start guide

KOLO ATOL PLUS installation manual

KOLO

KOLO ATOL PLUS installation manual

Hans Grohe PuraVida 15073000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe PuraVida 15073000 Instructions for use/assembly instructions

Toto TS111B8 Installation and owner's manual

Toto

Toto TS111B8 Installation and owner's manual

Kohler K-1158-H2 Homeowner's guide

Kohler

Kohler K-1158-H2 Homeowner's guide

Coram Showers OFFSET QUADRANT manual

Coram Showers

Coram Showers OFFSET QUADRANT manual

baliv DU-2010 manual

baliv

baliv DU-2010 manual

odass OD-1710 instruction manual

odass

odass OD-1710 instruction manual

Oxygenics Evolution Easy installation instructions

Oxygenics

Oxygenics Evolution Easy installation instructions

Bradley Express SS Series installation instructions

Bradley

Bradley Express SS Series installation instructions

Helvex TH-974 installation guide

Helvex

Helvex TH-974 installation guide

DURAVIT C.1 C15240 0090 Instructions for mounting and use

DURAVIT

DURAVIT C.1 C15240 0090 Instructions for mounting and use

Sunshower PURE SOLO manual

Sunshower

Sunshower PURE SOLO manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

FIXED PANEL SCREEN FITTING INSTRUCTIONS –FX
Components:
Other equipment required:
1 x
1x
Bag 1
Bag 11


No 1 Square Drive Screwdriver
1 x
Clear Silicon

Caulking Gun
1 x
Blue Masking Tape

Drill
1 x
Screen Fitting Instructions

Level
Pencil
Checked by: ___________________
Date: _________________________
Included in with this shower package:
1 x
Fixed Panel 21 B

1 x
Blue Masking Tape

1 x
Wall Channel Tube

1 x
Clear Silicon Tube

1 x
4mm Drill Bit

1 x
Silicon Spatula

4 x
Wall Plugs

8 x
Plastics Packers –various sizes

4 x
Long Screws –sq. drive

PLEASE NOTE: Stand glass upright at all times. Keep glass panels level with the floor to avoid damaging
corners.
NO RESPONSIBILITY WILL BE TAKEN BY ATLANTIS FOR ANY GLASS BREAKAGES OR CHIPPED EDGES.
GLASS RECEIVER CHANNEL MUST BE INSTALLED ONTO THE WATERPROOFING BEFORE THE WALLS ARE
TILED
INSTRUCTIONS FOR FX-NTRB
CONFIGURATION
1. Position the glass receiver channel over the base
glazing channel. Use
a straight edge and
mark the wall to
indicate where the
wall channel is
plumb.
2. Apply a silicon seal
to full length of
channel. Silicon
used must be
compatible with
anodised
aluminium as well
as the
waterproofing
being used.
3. Ensure the glass receiver channel is located firmly
over the base glazing channel. The machine recess
in the wall glazing
channel must firmly
locate over the base
glazing channel.
Locate the framing
timber. Use the
4mm drill bit to drill
holes through the
glass receiver
channel. Fix four
screws through the
channel in the wall framing (use wall plugs if
required).
4. Apply a continuous bead of silicon to the full
length of the
channel and
waterproofing,
indicated by the
dark line (inside
channel).
5. Slide the sill infill into position and apply 6mm
plastic packers
into the base
glazing channel in
locations as
shown.
6. CRITICAL SEAL
Remove the dust and
dirt first. Seal the
connection between
the glass receiver
channel and the base
glazing channel with
clear silicon, prior to the installation of panel 21 B.
Ensure the corner junction between wall channel
and base channel is full of silicon before final glass
placement. It is vital that
all junctions are sealed
sufficiently.
Prior to installation of
fixed panel and infill all
connections of channels
must be sealed with
clear silicon supplied.
7. Locate the glass panel 21 B into the glazing
channels. The top of the panels should align to the
top of the glass receiver channel.
Add or remove
plastic packers
in the base
glazing channel
as necessary.
8. SILL INFILL
Apply a continuous bead of clear silicon to each
inside face of the base channel. Ensure the ends
of the infill are sealed and place into the base
channel in the location as shown.
9. FASTENING GLASS
Secure the glass panel into the receiver channels
by tightening hex screws firmly with hex key
supplied. Do not overtighten.
10. SILICON APPLICATION
Using the blue tape supplied, mask the glazing
channel and glass at the intersections shown.
Apply clear silicon to the inside and outside
of the glass panel (TWO SIDES OF GLASS). Use
the spatula provided to remove the excess silicon.
Remove the masking tape immediately after
application.
INSTRUCTIONS FOR FX-TRB
CONFIGURATION
1. Position the glass receiver channel over the base
glazing channel.
Use a straight
edge and mark the
wall to indicate
where the wall
channel is plumb.
2. Apply a silicon seal to full length of channel.
Silicon used must be compatible with anodised
aluminium as well as the waterproofing being
used.
3. Ensure the glass receiver channel is located
firmly over the base glazing channel. The
machine recess in the wall glazing channel must
firmly locate over the base glazing channel.
Locate the framing timber. Use the 4mm drill bit
to drill holes
through the
glass receiver
channel. Fix four
screws through
the channel in
the wall framing
(use wall plugs if
required).
4. Apply a continuous bead of silicon to the full
length of the
channel and
waterproofing,
indicated by
the dark line
(inside
channel).
5. PREPARATION FOR GLASS INSTALLATION
Slide the sill
infill into
position and
apply 6mm
plastic packers
into the base
glazing channel
in locations as
shown.
6. CRITICAL SEAL
Remove the dust and dirt first. Seal the
connection between the
glass receiver channel
and the base glazing
channel with clear
silicon, prior to the
installation of panel 21
B. Ensure the corner junction between wall
channel and base channel is full of silicon before
final glass
placement. It is vital
that all junctions are
sealed sufficiently.
Prior to installation
of fixed panel and
infill all connections
of channels must be
sealed with clear
silicon supplied.
7. INSTALLATION OF FIXED PANEL
Locate the glass panel 21 B into the glazing
channels. The top of
the panels should
align to the top of the
glass receiver
channel.
Add or remove plastic
packers in the base
glazing as necessary.
8. SILL INFILL
Apply a continuous bead of silicon to each inside
face of the base channel. Ensure the ends of the
infill are
sealed and
place into
the base
channel in
the location as shown.
9. SILICON APPLICATION
Using the blue tape supplied, mask the glazing
channel and glass at the intersections shown.
Apply clear
silicon to the
inside and
outside of the
glass panel
(TWO SIDES OF
GLASS). Use the
spatula provided
to remove the
excess silicon.
Remove the masking tape immediately after
application.
10. TOP BRACE INSTALLATION
Choose the
preferred distance
of the top rail from
the tiled wall, as
shown in Fig 1.
11. Mount the end
connector channel
the end connector
channel. Ensure the
top face of it is
6mm above the top
of the fixed glass
panel. CSK holes
face upward.
12. Apply an 8mm
dot of clear
silicon inside
the end of the
top rail brace
in location as
shown.
13. Trim the top rail brace to length if necessary.
Drill and retain with
screws supplied.
Slide into the end
connector channels.
Drill into CSK holes
provided. Fix with
the short CSK screws.