Owner Installation Instructions Axess Pro Series 3000 19
16.1 Safety Close Mode
The controller has a built in Safety Beam detection. If Safety
Beams are not installed, the controller will automatically turn on
the Safety Close Mode. By enabling this parameter, the shutter
can only be closed by holding the close button on the wall control
unit (Dead Man Set Up).
In order to facilitate an Automated Set Up and enable to shutter
to be closed by a transmitter proceed by;
Navigate to “Safety Close Mode (Menu 6.1)”
a. Press the OPEN button.
b. Warning will display.
DANGER! Read Manual before turning off Safety
Close Mode. Press SET to continue.
c. Press SET to accept the warning.
d. Press either the OPEN or CLOSE arrows to change to OFF.
e. Press SET to Save the change.
WARNING! The Auto-Close function is not
available unless Safety Beam is installed.
16.2 Setting Up Satndard Auto-Close Mode
Menu 3. Auto-Close Times
The Auto-Close modes automatically close the shutter after it has
been operated. To implement this the controller starts a timer
once the shutter has reached its desired open position. The
timer then counts down and when it expires the controller starts
to close the shutter. Details about the four Auto-Close modes
follow. Automatic Technology strongly recommend using a Safety
Beam for added safety.
Menu 3.1 Standard Auto Close
This mode is selected by entering a non-zero time for the STD
Auto-Close parameter. When selected, the shutter will Auto-Close
after being fully opened (except when the shutter has reversed
to the open position after a motor obstruction or overload.
Countdown is suspended by: S.B., OPN or SWP input being
active. The countdown is aborted if the STP input is activated.
If the shutter is already open and the OPN or the SWP input is
activated, then the countdown will start.
16.3 Safety Beam Triggered Auto Close
Menu 3.2 (SB AC Trig)
This mode is selected by entering a non-zero time for the “Safety
Beam Auto-Close” parameter. This mode is used to Auto-Close
the shutter but only after an object has passed through the
doorway and has triggered the Safety Beam input. Any Safety
Beam or combination of Safety Beams can be configured to
activate Safety Beam Auto-Close mode and combinations are:
One Beam only
i. Safety Beam 1
ii. Safety Beam 2
iii. Safety Beam 3
Either Beam
iv. Safety Beam 1 or Safety Beam 2
v. Safety Beam 1 or Safety Beam 3
vi. Safety Beam 2 or Safety Beam 3
vii. Safety Beam 1 or Safety Beam 2 or Safety Beam 3
Combination
viii. Safety Beam 1 and Safety Beam 2
ix. Safety Beam 1 and Safety Beam 3
x. Safety Beam 2 and Safety Beam 3
xi. Safety Beam 1, Safety Beam 2 and Safety Beam 3
16. Auto-Close Mode for V2 Console
NOTE: The swipe input can be used to clear the Safety Beam
triggered status so that the Safety Beam input must be activated
again before the countdown will start. As with the other Safety Beam
modes, the STP input will abort countdown and the OPN and SWP
inputs will restart the countdown if the shutter is OPEN.
Menu 3.3 Directional Auto-Close (SB Auto Close)
This mode is selected by entering a non-zero time for the “S.B. Auto-
Close” parameter. S.B 3 Beam must be installed and configured to
EXIT WITH SB1. Sub in menu 6.5. This mode is used to Auto-Close
the shutter only after a vehicle has passed through the Safety Beam
3 and then through Safety Beam 1 to exit the premises . This mode is
useful for fire brigade, ambulance stations etc.
16.4 Pedestrian Auto-Close
Menu 3.4 Pedestrian Auto-Close
This mode is selected by entering a non-zero time for the “Ped’n
A/C” parameter. When selected, the door will Auto-Close after being
opened for pedestrian access unless it was following a reverse from
an obstruction.
Menu 3.5 (Safety Beam) Pedestrian Triggered Auto-Close
Any Safety Beam or combination of Safety Beams can be configured
to activate Safety Beam Auto-Close mode.
Menu 3.6 (Safety Beam) Pedestrian Auto-Close
This mode is selected by entering a non-zero time for the “Ped’n
A/C” parameter. When selected, the door will Auto-Close after being
opened for pedestrian access unless it was following a reverse from
an obstruction.
16.5 Auto-Close After Obstruction:
Three parameters are provided to enable the Auto-Close feature to
be activated after obstructions and power up. Normally the Auto-
Close feature is not enabled after obstructions for safety reasons.
Safety Beams must be used for these features to be activated. The
three parameters are:
Menu 3.7 (Auto-Close after close overload)
This mode enables the Auto-Close feature to be activated when a
close overload occurs (requires Safety Beams).
Menu 3.8 (Auto-Close after open overload)
This mode enables the Auto-Close feature to be activated when an
open overload occurs.
Menu 3.9 (Auto-Close after power up)