12 NeoSliderTM - Sliding Gate Opener NES-24V2 Owner Installation Instructions
8. Setting Limits
The NeoSliderTM has the alternate ability to set travel limits using
a TrioCodeTM128 transmitter, allowing free movement around the
gate to better assess the desired limit positions. In order to use a
transmitter, it must first have at least one of its buttons coded to the
gate controller. The function assigned to the transmitter’s buttons
is of no concern here as the buttons are temporally assigned to
OPEN, CLOSE and SET (Fig. 8.1).
NOTE: Gate should be moved manually to fully open position.
When re-engaging opener, nudge gate until click is heard to
confirm pinion gear has engaged fully.
8.1 Setting Travel Limits
Navigating to “code transmitter” menu
a. Press NEXT to navigate to Menu 1.
b. Press SET to enter the code set procedure (Fig. 8.2).
Storing Transmitter Code
c. Controller will prompt to press one of the transmitter’s Button.
d. Press the transmitter button you wish to use to operate the
gate opener (e.g. button 1) .
e. Press the same transmitter button again as prompted by
display.
f. Press the SET button to store the transmitter.
Navigating To “Set Gate Travel Menu”
g. Press PREV to navigate to Menu 10.
h. Press SET to display MENU 10.1.
i. Press SET two times to enter the limit setting procedure. Follow
LCD prompts.
8.2 Setting the left/right installation side settings
a. Select left or right installation side by pressing open button for the
correct side (Fig. 8.2).
b. Press SET to confirm.
8.3 Setting close travel limit
a. Press and hold Button 4 on the transmitter to close the gate
i. If the gate is closed too far, press Button 1 to “inch” the
gate towards open.
ii. When happy with the close limit position, press Button 2 to
store this in the memory.
NOTE: Limit will not be accepted unless the gate is driven in the
close direction.
8.4 Setting open travel limit
a. Press Button 1 to open the gate.
b. If the gate is opened too far, press Button 4 to “inch” the gate
towards close
c. When happy with the open limit position, press Button 2 on the
transmitter to store into memory..
NOTE: Limit will not be accepted unless the gate is driven in the
open direction.
WARNING: The gate will automatically close and
open once next step is performed. Ensure that no
persons or objects are in the gates path
d. The gate will now automatically close and open to calculate the
safety obstruction settings.
Fig 8.1
Fig 8.2
Button 1
(Inch Open)
Button 4
(Inch Close)
Button 2
(Set)
Menu 1
Code Transmitter
PRESS
8.5 Automatic limit adjustment and load profile
After a brief pause, the controller will automatically close and open
the gate several times. This adjusts the speed at which the limits are
approached and helps to learn the normal load profile of the gate.
When the setup is complete, the MAIN SCREEN will be displayed
with the gate shown to be OPEN. The Gate can now be used.
NOTE: Do not press transmitter during limit adjustment process.
8.6 Pedestrian access position
After completing the above procedure, the Pedestrian access
position is automatically set to a position which is five (5) seconds
from the fully closed position of the gate. The position can be
manually set by following the SETTING PEDESTRIAN POSITION
procedure (See Section 12).
8.7 Errors during setting of travel limit
During the above procedure, many error checks are preformed. If an
error is detected, a message will be displayed indicating the error.
8.8 Recalculate Force Margins
a. Reprofiling is a simplified way of re-learning the travel
characteristic of a previously setup Limit Switch travel installation.
Re-profiling can be used when the travel characteristics of the
gate change due to mechanical adjustments etc.
b. To initiate a re-profile simply locate “MENU 10.2 Reprofile Travel”
WARNING: The gate(s) will automatically close and
open. Ensure that no persons or objects are in the
gates path.
c. Press SET then follow the prompts. The gate will start to move
and re-calculate force margins. The gate can move between the
open and close limit positions up to two (2) times (depending on
the position of the gate and the power up condition).
d. A single beep will be heard once the process is complete and
setup complete message will be displayed
IMPORTANT NOTE:
Only TrioCodeTM128 Technology
Transmitters are compatible with
this product.