Autonics ACS Series User manual

(A)
Sensor
connector
(B)
I/O terminal
block
(C)
I/O cable
(D)
Remote I/O
terminal block
B-13
Common Terminal Block
AFS
AFL/AFR
ACS
AFE
ABS
Relay
ACS Series
Common terminal block
lCompact common terminal block with 7 mm terminal pitch
lNo Jumper bars required due to built-in PCB common
lAvailable for power supply expansion terminal block
lSpace saving with compact size
l2 ways of mounting (DIN rail, mounting with screws)
Model
Features
Applied crimp terminal
<Round>
<Forked>
(unit:mm)
A B C D Applied wire
Forked Min. 4.1 Max. 16.0 Min. 3.0 Max. 5.9 AWG 22-16
(0.30 to 1.25 mm2)
Round Min. 4.1 Max. 16.0 Min. 3.0 Max. 5.9
Model ACS-20L ACS-20T ACS-40L ACS-40T ACS-50L ACS-50T
Rated voltage Max. 125 VDC, 125 VAC 50/60 Hz
Rated current Max. 10 A
COMMON type Left +COM,
Right -COM
Top +COM,
Bottom -COM
Left +COM,
Right -COM
Top +COM,
Bottom -COM
Left +COM,
Right -COM
Top +COM,
Bottom -COM
Number of terminals 20EA 40EA 50EA
Terminal pitch 7.0 mm
Applied wire AWG22-16(0.30 to 1.25mm2)
Insulation resistance Min. 1,000 ㏁ (at 500 VDC megger)
Dielectric strength 600 VAC 50/60 Hz for 1 min.
Vibration 0.75 mm amplitude at frequency of 10 to 55 Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Shock 150 m/s2(15G) in each of X, Y, Z directions for 3 times
Environ-
ment
Ambient
temperature -15 to 55 ℃, storage : -25 to 65 ℃
Ambient
humidity 35 to 85%RH, storage : 35 to 85%RH
Material CASE : MPPO, TERMINAL PIN : Brass
Tightening torque 0.5 to 0.6 N·m
Approval
Weight※1 Approx. 92g (approx. 61 g) Approx. 157g (approx. 115 g) Approx. 189g (approx. 141 g)
Specications
Model Item Terminal type Number or terminals Common type
ACS-20L
Common
terminal block Screw
20EA Left-Right Common
ACS-20T Top-Bottom Common
ACS-40L 40EA Left-Right Common
ACS-40T Top-Bottom Common
ACS-50L 50EA Left-Right Common
ACS-50T Top-Bottom Common
Please read “Caution for your safety” in operation manual
before using this unit.
A
B
C
D
A
B
C
D
※Use the UL cirtied crimpt terminal.
※1: The weight is with packaging and the weight in parentheses is only unit weight.
※Environment resistance is rated at no freezing or condensation.

B-14
ACS Series
Dimensions
l
ACS-20L(T)
(unit: mm)
l
ACS-40L(T) / ACS-50L(T)
Connections
l
ACS-20T
l
ACS-40L
l
ACS-50L
l
ACS-40T /
ACS-50T
l
ACS-20L
※Dot line part is only for ACS-50T model.
ACS-40L(T) ACS-50L(T)
A 150 184
B 89 104
C 45.8 48.9
D 39.7 34.8
-- - - - ---- -
A1 A2 A3 A4 A5 A6 A7 A8 A9
A10
B1 B2 B3 B4 B5 B6 B7 B8 B9
B10
++ + + + + ++ + +
B1 B2 B3 B4 B5 B6 B7 B8 B9
B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20
++ + + + + + + + + -- - ------ -
++ + + + + + + + + -- - ------ -
A1 A2 A3 A4 A5 A6 A7 A8 A9
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20
B1
+ + + + +- - - - -
+ + + + - - - - -
+
B6
A1 A6
B2 B7
A2 A7
B3 B8
A3 A8
B4 B9
A4 A9
B5
B10
A5
A10
B1 B2 B3 B4 B5 B6 B7 B8 B9
B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20
++ + + + + + + + + + + + ------ -
++ + + + + + + + + + + - ------ -
A1 A2 A3 A4 A5 A6 A7 A8 A9
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20
-
B21 B22 B23 B24 B25
--- -
---- -
A22 A23 A24 A25
A21
-- - ------ -
-- - ------ -
A1 A2 A3 A4 A5 A6 A7 A8 A9
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20
B1 B2 B3 B4 B5 B6 B7 B8 B9
B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20
++ + + + + + + + + ++ + + + + + + + +
---- -
A21 A22 A23 A24 A25
B21 B22 B23 B24 B25
+ + + + +
39.7
35.2
45.8
32.5
2-Ø3.5
80
7
5.9
62.5
39.5
10.5
41.8
20-M3
11
D
35.2
C
32.5
2-Ø3.5
7
5.9
A
B
39.5
10.511
41.8
40-M3,
50-M3

(A)
Sensor
connector
(B)
I/O terminal
block
(C)
I/O cable
(D)
Remote I/O
terminal block
B-15
Common Terminal Block
AFS
AFL/AFR
ACS
AFE
ABS
Relay
①②
Rail lock
DIN rail
connection
DIN rail
lMounting
1)Push the rail lock to the direction "①".
2)Hook DIN rail connection onto DIN rail.
3)Push the unit down to the direction "②" and then
push up the rail lock to the unit body.
1)This unit is able to mount on the panel with
mounting holes.
2)It is recommended to use M3×30 mm of spring
washer screws and to use flat washers which are
diameter Ø 6. The tightening torque should be 0.5
to 0.7 N·m.
lRemoving
1)Insert a screwdrive into holes of rail lock and pull
the lock out to the direction "①".
2)Removing the unit by pulling to the direction "②".
Installations
Mounting to and Removing from DIN rail Mounting with screws
Panel
mounting hole
①
②
Rail lock
Caution for using
1. Use the product within the rated specifications for operating temperature and humidity.
2. Check voltage fluctuations in the power supply within the rated range.
3. When connecting PLC or other controllers, check the polarity of power before wiring.
4. Use AWG 16 (1.25 mm2) wire and applied crimp terminals to the terminal block.
5. Turn OFF the power supply before wiring or removing connectors.
6. Do not use this unit at below places.
① Place where there is severe vibration or impact
② Place where strong alkalis or acids are used
③ Place where there are direct ray of the sun
④ Place where strong magnetic field or electric noise are generated
7. Installation environment
① It shall be used indoor.
② Altitude max. 2,000 m
③ Pollution Degree 2
④ Installation Category II
This manual suits for next models
6
Table of contents
Other Autonics Terminal Block manuals
Popular Terminal Block manuals by other brands

Panasonic
Panasonic TY-SB01SS operating instructions

Festo
Festo CPV GE-ASI-4E4A-Z-CE Series manual

Crestron
Crestron CLTI-1DIM4 installation guide

Festo
Festo CPV GE-IL Series Brief description

Panasonic
Panasonic TY-FB9BD operating instructions

National Instruments
National Instruments SCXI-1300 installation guide