Autonics KT-502H Series User manual

J-236
KT-502H Series
•HART protocol
•Display rotation in 330 ° range
•Better visibility with supporting backlight function
•Various inputs (to order, select one from 22 kinds)
- RTD 8 types
- Thermocouple 8 types
- mV 8 types
- Resistor 2 types
•Explosion-proof specication: Ex D IIC T6
•Protection structure: IP67 (IEC standard)
Model KT-502H
Power supply 10.5-45VDCᜡ (with backlight LCD)
Display method
PV display part: 7-segment 5-digit (character size: W4×H8mm),
Parameter display part: 14-segment 8-digit (character size: W2.6×H4.8mm),
52-bar meter
Display range -19999 to 99999
Setting method HART-protocol (no setting key)
Response time 1 sec
Input type
RTD DPt100Ω, DPt500Ω, DPt1000Ω, Ni100Ω, Ni500Ω, Ni1000Ω, Cu50Ω, Cu100Ω
Thermocouple K, J, T, E, N, S, B, R
Resistance transmission (Ω) 0 - 400Ω, 0 - 2000Ω
Voltage transmission (mV)
10 - 75mV,
100 - 100mV,
100 - 500mV,
100 - 2000mV
Output DC4-20mA (2-wire)
Accuracy ±0.3%
Alarm Below 3.8mA, Over 20.5mA/Sensor break 3.6mA
Load Max.(V power supply - 7.5V)/0.22A
Galvanic insulation 2,000VAC (input/output)
Environ-
ment
Ambient temperature -20 to 70℃, storage: 20 to 80℃
Ambient humidity 0 to 85%RH, storage: 0 to 85%RH
Explosion class※1Ex d IIC T6
Protection structure IP67 (IEC standard)
Material Body: Aluminum (AlDc.8S), Cover O-Ring: Buna N
Weight※2Approx. 1.4kg (approx. 1.2kg)
※1: The explosion class specication is acquired and managed by KONICS.
※2: The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.
Item Description
①Mounting bracket 0Without bracket 1With bracket
②User temperature range 1: To order this unit, write the temperature sensor type and the temperature range.
502H 0KT (-270 to 1372, K)※1
① ②
Temperature Transmitters with HART Protocol
Features
Ordering Information
Specifications
Please read “Safety Considerations”
in the instruction manual before using.

J-237
Temperature Transmitters with HART Protocol
(unit: mm)
Input type Input range(℃)Input range(℉)
RTD
DPt100Ω 200 to 850 328 to 1562
DPt500Ω 200 to 250 328 to 482
DPt1000Ω 200 to 250 328 to 482
Cu50Ω 50 to 150 58 to 302
Cu100Ω 50 to 150 58 to 302
Ni100Ω 60 to 180 76 to 356
Ni500Ω 60 to 180 76 to 356
Ni1000Ω 60 to 150 76 to 302
Resistance
transmitter Resistance (Ω) 0 to400Ω
-
0 to2000Ω
Thermocouple
B
(PtRh30-
PtRh6)
0to 1820 32 to 3308
E(NiCr-CuNi) 270 to 1000 454 to 1832
J(Fe-CuNi) 210 to 1200 346 to 2192
K(NiCr-Ni) 270 to 1372 454 to
2501.6
N(NiCrSi-NiSi) 270 to 1300 454 to 2372
R(PtRh13-Pt) 50 to 1768 58 to
3214.4
S(PtRh10-Pt) 50 to 1768 58 to
3214.4
T(Cu-CuNi) 270 to 400 454 to 752
Analog Voltage
10 - 75mV
-
100 - 100mV
100 - 500mV
100 - 2000mV
● Opening cover
To open the cover,
unscrew the M3×6L
headless bolt using a 1.5
hexagon wrench and rotate
the cover.
Ø83
142
2-(1/2 14NPT)
83
55
96
● Mounting bracket
Mounting bracket
96
200
94
DN50
(2B Pipe)
HART Communicator
Power
Supply
Indicator
Recorder
DCS
Controller
1 2 3 4 5 6
Power supply
10.5-45VDC
+
-
A B b
RTD
mV
+
+
-
-
TC
Min. 250Ω
Dimensions
Input Type and Range Connections

J-238
KT-502H Series
Fid dev output 20.000
mA equal to reference
meter ?
1. Yes
2. No ABORT ENTER
NOTE-Loop may be
returned to automatic
control
ABORT O K
Device Disconnected
RETRY QUIT
1. Oine
2. Online
3. Frequency Device
4. Utility
Setting d dev.
output to 20mA
ABORT O K
Enter meter Value
20.000
HELP DEL ABORT ENTER
Diag/Service
1. Test device
2. Loop test
3. Calibration
4. D/A trim
HELP SAVE HOME
⑫Press the (F4) key.
⑬Press the (F3) key.
⑭Press the (F3) key.
⑮Press the (F3) key to complete the adjustment.
⑪ If output display value is correct, select '1. Yes' and press
the (F4) key. If not, select '2. No' and press the
(F4) key and re-set the display value.
⑨Press the (F4) key.
⑩Press the (F4) key to set 20 mA display value.
1. Device Setup
2. PV
3. PV Ao
4. PV LRV
5. URV
1. Process Variables
2. Diag/Service
3. Basic Setup
4. Detailed Setup
5. Review
1. Test device
2. Loop test
3. Calibration
4. D/A trim
Connect reference
meter
ABORT O K
Fid dev output 4.000
mA equal to reference
meter ?
1. Yes
2. No ABORT ENTER
Enter meter Value
4.000
HELP DEL ABORT ENTER
Setting d dev
output to 4mA
ABORT O K
WARN-Loop should be
removed from
automatic control
ABORT O K
①Select the '1. Device Setup' by , keys and press the
key.
Connect a HART communicator and adjust current trim as below by a HART communicator.
②Select the '2. Diag/Service' by , keys and press the
key.
③Select the '4. D/A trim' by , keys and press the
key.
④Press the (F4) key.
⑤Press the (F4) key.
⑥Press the (F4) key.
⑦Press the (F4) key to set 4 mA display value.
⑧ If output display value is correct, select '1. Yes' and press
the (F4) key. If not, select '2. No' and press the
(F4) key and re-set the display value.
Ex)If output display value is 3.89mA, select 3.89 and press
the (F4) key.
Display Error Troubleshooting
ERR05
Temperature sensor
A, B or all sensors are
disconnected. Check the temperature
sensor.
ERR06 Temperature sensor B
is disconnected.
ERR07
When PV is lower than
the low-limit value of
set temperature range.
Check low-limit value
of the set temperature
range.
ERR08
When PV is higher than
the high-limit value of
set temperature range.
Check high-limit value
of the set temperature
range.
Current Trim Adjustment
Error Display and Troubleshootings

J-239
Temperature Transmitters with HART Protocol
•Follow instructions in 'Cautions during Use'.
Otherwise, it may cause unexpected accidents.
•Power supply should be insulated and limited voltage/current or Class 2, SELV power
supply device.
•Keep away from high voltage lines or power lines to prevent inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
•Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
• The explosion-proof standard of this unit is Ex d IIC T6, protection structure of this unit is
IP67 and the range of max. surface temperature is below 85℃.
Use the veried explosion-proof electric connection (cable gland or sealing tting)
•This unit may be used in the following environments.
①Indoors (in the environment condition rated in 'Specications')
②Altitude max. 2,000m
③Pollution degree 2
④installation Category II
The explosion-proof unit is certied and the same specications which is reported to Korea Gas Safety Cor-
poration. (This unit is manufactured following by the announcement 2013-54 of Ministry of Employment and
Labor of Korea.)
Cautions During Use
1. PV LRV
2. URV
HELP HOME
②Select '1. PV LRV'(Low temperature range) and
press the key.
PV LRV
0.000 deg C
0.000
HELP DEL ESC ENTER
③Set Low temperature range and press the (F4)
key.
1. PV LRV
2. URV
HELP HOME
④Select '2. URV'(High temperature range) and press the
key.
Online (Generic)
1. Device Setup
2. PV
3. PV Ao
4. PV LRV
5. URV SAVE
①Press the key for 3 sec. Select the '4. PV LRV' by ,
keys and press the key.
PV URV
100.000 deg C
100.000
HELP DEL ESC ENTER
⑤Set High temperature range and press the (F4)
key.
1. PV LRV 0.000 deg C
2. URV 100.000 deg C
HELP SEND HOME
⑥ When the set temperature range is correct,
press the (F2) key.
- WARNING -
Pressing ' OK ' will
change device output
put 100P in manual
⑦Press the (F4) key.
- WARNING -
Return control 100P
To automatic control
O K
⑧Press the (F4) key.
1. PV LRV 0.000 deg C
2. URV 100.000 deg C
HELP HOME
⑨ Check the set temperature range. Press the (F3)
key. HART communication is OFF.
Connect a HART communicator and set temperature range as below by a HART communicator.
Temperature Range Setting
Proper Usage
Other Autonics Transmitter manuals
Popular Transmitter manuals by other brands

United Electric Controls
United Electric Controls TX200 Installation & maintenance instructions

Kramer
Kramer TP-112HD user manual

TESTO
TESTO 0555 4444 instruction manual

Tri-Tronics
Tri-Tronics Sport 50 G2 manual

BWI Eagle
BWI Eagle AIR-EAGLE FM2 43-1150-120VAC Product information bulletin

Air Monitor
Air Monitor AUTO-purge III Installation, operation and maintenance manual