Autonics TPS30 Series User manual

TPS30 Series
F-1
••Robust build allows high or low pressure measurement in
high and low temperature environments.
: high pressure (0 to 60MPa), low pressure (0 to 2 MPa)
: temperature range (-40 to 125℃) (may vary by model)
•For diverse applications including packaging machines,
heavy machinery, factories, and shipbuilding.
•Pressure measurement of any gas, liquid, or oil.
•316L stainless steel diaphragm for high corrosion resistance.
••Compact size allows easy installation in tight or limited
spaces.
••1ms high-speed response rate.
••Analog output: Voltage (1-5 VDC), Current (DC 4-20 mA)
••Built-in reverse polarity protection circuit.
••Various connector types
: cable type, DIN43650-A connector type, DT04-3P
connector type, M12 connector type, head type.
••Available thread sizes: G3/8, G1/4, R1/2
••Protection structure: IP67 (IEC standard)
(except DIN43650-A connector type: IP65)
Description
①Item TPS30 Pressure Transmitter
②Measurement pressure G Gauge pressure, sealed gauge pressure※1
A Absolute pressure
③Cable
1 Head type
2 DIN43650-A connector type
3 M12 connector type
4 DT04-3P connector type
5 Cable type
④Pressure range
Gauge pressure Absolute pressure
3 0 to 0.1MPa 0 to 0.1MPa
4 0 to 0.2MPa 0 to 0.2MPa
5 0 to 0.7MPa 0 to 0.7MPa
6 0 to 1MPa 0 to 1MPa
7 0 to 2MPa 0 to 2MPa
8※20 to 3.5MPa
-
9※20 to 5MPa
-
A※20 to 10MPa
-
B※20 to 20MPa
-
C※20 to 40MPa
-
D※20 to 50MPa
-
E※20 to 60MPa
-
Sealed gauge pressure※1
F -0.1 to 0MPa
G- 0.1 to 0.1MPa
H -0.1 to 0.7MPa
J -0.1 to 1MPa
K -0.1 to 2MPa
Z Others
⑤Output type V Voltage (1-5VDC) output
A Current (DC4-20mA) output
⑥Pressure port
G8 G3/8 (PF)(EN387)
G4 G1/4 (PF)(EN387)
R2 R1/2 (PT)(DIN3852)
N4 NPT1/4 (DIN3852)
ZZ※3Others (option)
⑦Option (connector cable)※4
00 Not used
2I "I" type 2m
2L "L" type 2m
5I "I" type 5m
5L "L" type 5m
⑧User pressure range User pressure range※5
※1: The pressure is sealed gauge pressure. The unit is sealed structure. It is based on atmospheric pressure 101.3kPa (1.013bar).
※2: G1/4 is the standard pressure port. For the other pressure ranges, G3/8, R1/2 are standard pressure ports.
※3: The option ports are sold separately. In case of large amount ordering, contact the Autonics for manufacturing the requested pressure port.
※4: Only for M12 connector type.
※5: Write the desired pressure range and it is the default of user pressure range. (select "Z" at ④Pressure range)
G 2 9 V G8 00TPS30
①② ③ ④ ⑤ ⑥ ⑦ ⑧
(0 to 0.5MPa)
Ordering Information
Please read “Safety Considerations” in operation manual
before using this unit.
Features
Cable type DIN43650-A
connector
type
M12
connector
type
Head typeDT04-3P
connector
type

TPS30
TPS20
KT-302H
PTF30
Pressure Transmitter
F-2
A. Recorders
B. Indicators
C. Converters
D. Controllers
E. Thyristor
Power
Controllers
F. Pressure
Transmitters
G. Temperature
Transmitters
H. Accessories
※1: The sensor is sealed structure. It is based on atmospheric pressure 101.3kPa (1.013bar).
※2: The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.
Series TPS30
Pressure type Gauge pressure,
absolute pressure Sealed gauge pressure※1Gauge pressure
Rated pressure
range (MPa)
0 to
0.1
0 to
0.2
0 to
0.7
0 to
1
0 to
2
-0.1 to
0
-0.1 to
0.1
-0.1 to
0.7
-0.1 to
1
-0.1 to
2
0 to
3.5
0 to
5
0 to
10
0 to
20
0 to
40
0 to
50
0 to
60
Expanded analog
output range (MPa)
0 to
0.11
0 to
0.22
0 to
0.77
0 to
1.1
0 to
2.2
-0.1 to
0.01
-0.1 to
0.12
-0.1 to
0.78
-0.1 to
1.11
-0.1 to
2.21
0 to
3.85
0 to
5.5
0 to
11
0 to
22
0 to
44
0 to
55
0 to
66
Max. pressure
range (MPa)
0.6 0.6 3330.6 0.6 33310 20 50 80 120 120 120
Burst pressure
(MPa) 0.6 0.6 3330.6 0.6 33315 30 75 120 160 160 160
Measured
materials Liquid, gas, oil (inappropriate to corrosion environment for stainless steel 316L)
Power supply Voltage output type: 8-36VDCᜡ(ripple P-P: max. 10%) Current output type: 11-36VDCᜡ(ripple P-P: max. 10%)
Permissible
voltage range 90 to 110% of rated voltage
Current
consumption Voltage output type: max. 20mA Current output type: max. 30mA
Response time Max. 1ms
Protection circuit Reverse polarity protection circuit
Output type Voltage output type: 1-5VDCᜡCurrent output type: DC4-20mA
Compensation
temperature -10 to 80℃0 to 80℃
Accuracy Max. ±0.5% F.S. (including linearity, hysteresis, reproducibility)
Linearity Max. ±0.2% F.S.
Hysteresis Max. ±0.2% F.S.
Temp. Zero Shift Max. ±0.1% F.S./10℃(standard), max. ±0.25% F.S./10℃(max.)
Temp. Span Shift Max. ±0.1% F.S./10℃(standard), max. ±0.25% F.S./10℃(max.)
Temperature
characteristics
-
-25 to 100℃: max. ±1.5% F.S.
-40 to 125℃: max. ±2.5% F.S.
Load resistance Current output type: max. 700Ω (supplying 24VDC)
Dielectric strength 500VAC 50/60Hz for 1 minute
Insulation
resistance Over 100MΩ (at 500VDC megger)
Environment
Ambient
temp.
Voltage
output
Head type, DIN43650-A connector type, M12 connector type, DT04-3P connector type: -40 to 125℃, storage: -40 to 125℃
Cable type: -40 to 80℃, storage: -40 to 80℃
Current
output
Head type, DIN43650-A connector type, M12 connector type, DT04-3P connector type: -40 to 85℃, storage: -40 to 125℃
Cable type: -40 to 80℃, storage: -40 to 80℃
Ambient humidity
35 to 85%RH
Fluid temp. -40 to 125℃
Vibration 10g, 20 to 2,000Hz 20g, 20 to 2,000Hz
Shock 100g/6ms 500g/1ms
Tightening torque Max. 10N.m
Protection
structure
Head type, M12 connector type, DT04-3P connector type, cable type: IP67 (IEC standard)
DIN43650-A connector type: IP65 (IEC standard)
Material Stainless steel 316L (head part of head type: aluminium diecasting), connector: polybutylene terephthalate G30,
water-proof rubber: silicon
Connection Voltage output type: +, -, Vout Current output type: +, -
Approval ᜢ
Weight※2
Head type: approx. 330g (approx. 250g)
DIN43650-A connector type, M12 connector type, DT04-3P connector type: approx. 130g (approx. 50g)
Cable type: approx. 200g (approx. 120g)
Specications

TPS30 Series
F-3
M12 connector type
DIN43650-A connector type
(unit: mm)
DT04-3P connector type
Head type
Dimensions
22
G3/8※1
(EN837)
19 8214.2
5.6
115
90
Ø24
22
19 20.3 10
5.6
35.9
Ø21
M12
connector
G3/8※1
(EN837)
Ø24
22
G3/8※1
(EN837)
19 18.8 19 3.4
5.6
46.8
Ø21
DT04-3P
connector
Connector: CS-DT3P,
sold separately
Ø24
22
□27
DIN43650-A
connector
24.4
63.2
33.2
46.5
G3/8※1
(EN837)
19
5.6

TPS30
TPS20
KT-302H
PTF30
Pressure Transmitter
F-4
A. Recorders
B. Indicators
C. Converters
D. Controllers
E. Thyristor
Power
Controllers
F. Pressure
Transmitters
G. Temperature
Transmitters
H. Accessories
Cable type
CID3-2/CID3-5 CLD3-2/CLD3-5
(unit: mm)
(unit: mm)
Ø14.8
L(m)
Ø5
40
M12 M12
L(m)
Ø5
27.5
Ø14.8
32
※Only for M12 connector.
Dimensions
Connection Cable (Sold Separately)
Ø24
22
19 20.3 21.7
5.6
47.6
Ø21
Ø5, 2m
G3/8※1
(EN837)
15
G1/4
(EN837)
12
NPT1/4
(DIN3852)
14.3
R1/2
(DIN3852)
※1: Pressure port
Model L(m) Material
CID3-2 2 PVC
CID3-5 5
Model L(m) Material
CLD3-2 2 PVC
CLD3-5 5

TPS30 Series
F-5
Voltage output type
Connector
Pin
type
Head type DIN43650-A
connector type M12 connector type DT04-3P
connector type Cable type
Brown
Black
Blue
Function
Pin
+ VCC 1 1 A Brown
- GND 3 C Blue
Vout Vout 2 4 B Black
N.C
-
3 2
- -
Troubleshooting
Current output type
Pin
type
Head type DIN43650-A
connector type M12 connector type DT04-3P
connector type Cable type
Brown
Blue
Function
Pin
+ VCC 1 1 A Brown
- GND 3 C Blue
N.C Vout 2, 3 2, 4 B
-
※In case of head type, remove the top cover.
Error Troubleshooting
No outputs
Check the power supply.
Check the polarity (+, -) when wiring the cable.
Check the connection part.
Abnormally uctuating output
Check the power supply.
Check the supplied pressure.
Check the pressure line.
Out of zero point output value
Check the power supply.
Check the load resistive value of current output type for a receiver is over 700Ω. (when supplying 24VDC)
Check the measuring point and transmission distance.
Check the line resistance is below 700Ω.

TPS30
TPS20
KT-302H
PTF30
Pressure Transmitter
F-6
A. Recorders
B. Indicators
C. Converters
D. Controllers
E. Thyristor
Power
Controllers
F. Pressure
Transmitters
G. Temperature
Transmitters
H. Accessories
Voltage (1-5VDC) output type ● Current (DC4-20mA) output type
••8-36VDC, 11-36VDC power supply should be insulated
and limited voltage/current or Class 2, SELV power supply
device.
••When installing the unit on pipe line, use the hexagon part
of connections not to turn the unit with a pipe wrench.
Do not use the unit with strong vibrations.
••The unit is manufactured with precisely. If you drop or
shock the unit, it may lose the function. Please treat the
unit carefully.
••Store the unit at the place without moisture, dust, and
vibration.
••This product which does not have drive part at sensing
part does not need to repair it. Even though inside of pressure
pipe is normally clean, it needs to take maintenance once
a year as below instructions.
①Check the broken status of outside.
②Check the pressure slot, cleanliness inside, and
corrosion state.
③Short each terminal and check the insulation resistance
between the case and power. (at 500VDC, over 100MΩ)
④Check zero, span adjustment and linearity by pressure
standards.
••When removing a sensor for maintenance, follow the
below instructions.
①Replace an O-ring which is used once.
②Be sure that diaphragm part is not damaged.
••Connect the power with the crimp terminals.
••Switch or circuit breaker should be installed nearby users
for convenient control.
••Do not use the unit near the high frequency instruments
(high frequency welding machine & sewing machine, large
capacity SCR controller).
••The unit cannot be repaired due to disassembled structure.
••The unit is xed with bolt and nut at the both sides of case.
Do not press excessive load (approx. 300kg/cm2), or
it may cause damage to the unit.
••Do not pull the cables with over 30N of tension force.
••Tighten the cable connection part rmly not to enter water
to the cable.
••This product may be used in the following environments.
①Indoors / Outdoors
②Altitude max. 2,000m
③Pollution degree 2
④Installation category II
※Cable color is only for cable type.
Example of external connections
Terminal
24VDC
DC4-20mA
Power 24VDC load 600Ω
Output DC4-20mA 2 wire
+
+ +
+
-
-
-
-
TPS30
KRN100 (100mm hybrid recorder)
Proper Usage
Connections
Main Circuit
8-36VDC
(brown) VCC
(blue) GND
(black) Voltage
(1-5VDC) Output
+
-
L
O
A
D
(brown) VCC
(blue) GND
Main Circuit
Current
amplier 11-36VDC
+
-
LOAD
Table of contents
Other Autonics Transmitter manuals
Popular Transmitter manuals by other brands

Festo
Festo SMAT-8M operating instructions

RadioLink
RadioLink RC8X Firmware Upgrade Instructions

CYP
CYP CH-1107 TX Operation manual

Rosemount
Rosemount 3051S Series quick start guide

BWI Eagle
BWI Eagle AIR-EAGLE SR PLUS Product information bulletin

BWI Eagle
BWI Eagle AIR-EAGLE FM2 43-1100 Product information bulletin