Page 4 For technical questions, please call 1-888-866-5797. 57042
(Continued from page 3)
9. Clean Pump
a. Turn Pressure Knob to PRIME/CLEAN indicator.
b. Rotate PRIME/SPRAY Valve to PRIME position.
c. Plug Sprayer into 120VAC grounded GFCI outlet.
d. Turn Power Switch on. Pump will start. If pump does
not start, turn Pressure Knob clockwise until it starts.
e. When paint has been purged and solvent begins to
run clear, rotate PRIME/SPRAY Valve to SPRAY
position. Pump will cycle on then stop.
10. Clean Hoses and Spray Gun
a. Unlock Trigger.
b. Point Spray gun into paint container, then press Trigger
to pump excess paint back into paint container.
c. Point Spray Gun at interior side of waste container.
Note: If using mineral spirits, hold Trigger Guard against
edge of metal waste container to ground Spray Gun.
Trigger
Guard
Waste
d. Press Trigger until solvent runs clear,
then release and lock Trigger.
11. If mineral spirits used, clean again with water.
12. When finished:
13. Rotate PRIME/SPRAY Valve to PRIME position.
a. Turn Power Switch off.
b. Unplug Sprayer.
c. Remove Hoses from containers.
d. Let Hoses dry completely before storage.
14. Clean Filter, Nozzle Guard, Spray Tip and Seal
a. Depressurize Sprayer.
b. Turn Power Switch off.
c. Unplug Sprayer.
d. Remove Spray Gun from Spray Hose.
e. Remove Handle from Spray Gun with included wrench.
Filter
Handle
Secure
wrench on
flat spots
f. Remove Filter by turning it counterclockwise.
g. Place Filter in container of solvent with
Nozzle Guard, Spray Tip and Seal.
h. Using included brush, scrub accessories until clean.
i. Let accessories dry completely.
j. Clean Spray Gun exterior with a cloth and proper solvent.
k. Reassemble Spray Gun and attach to Spray Hose.
15. Store Sprayer in a clean dry location
out of reach of children.
If Sprayer will not be used for longer than 48 hours,
store according to Long-Term Storage below.
NOTE: Dispose of solvent, paint and waste
according to local hazardous waste standards.
5Long-Term Storage
1. Clean Sprayer.
2. Depressurize Sprayer.
3. Designate storage area in a clean dry
location out of reach of children.
4. Remove Suction Hose from Sprayer.
5. Attach Suction Hose, included with Storage Fluid, to Sprayer.
6. Open Storage Fluid bottle, place Suction and Prime
Hoses in bottle, then place bottle on ground.
7. Rotate PRIME/SPRAY Valve to PRIME position.
8. Plug Sprayer into 120VAC grounded GFCI outlet.
9. Turn Power Switch on. Pump will start. If pump does
not start, turn Pressure Knob clockwise until it starts.
10. When Storage Fluid begins to flow out of
Priming Hose, turn Power Switch off.
11. Unplug Sprayer.
12. Leave Hoses in Storage Fluid bottle.
NOTE: After storage, dispose of storage fluid
according to local hazardous waste standards.