Award CHO83-901 User manual

CHO83-901
Range hood
Instruction Manual

CONTENT
1………………………………………. Notice
2……………………………………….. Installation
3……………………………………….. Notice of Installation
4……………………………………….. Safety Warning
5…………………………………………Use
6………………………………………… Maintenance
7………………………………………… Trouble shooting

(1) NOTICE
Thank you for choosing an Award range hood. Please read the instruction
manual carefully before use.
The installation work must be undertaken by a qualified and competent
person.
The manufacturer disclaims all liability for any damage or injury caused
as a result of not following instructions for installation contained in the
following text.
The range hood operates on 220-240V ~, 50Hz.

(2) INSTALLATION
The range hood should be placed at a distance of 65~75cm above the
cooking plane for best effect. See pic 1.
Install the hook on a suitable place once the installation height is fixed,
and keep it in line. The fixed position of the inside chimney bracket is the
place of chimney. See pic 2.
Install the expansion pipe and fix it with cable tie. Then p ut the range
hood on t he hook. Please note the expansion pipe is not included in t he
product. See pic 3.
Fix the outside chimney bracket on the outside chimney, and be sure that
the inside chi mney can be adj usted the height in it freely. Afterward s,
install the chim neys on the range hood and lead the expansion pi pe to
outside. See pic 4.
Adjust the height of the inside chim ney to the position of the inside
chimney bracket and fix it with screws , after adjusting the position, fix
the body with safety screws. Note: The two safety vents are positioned on
the back housing, with diameter of 6mm. See pic 5.

If you do not have an outlet to the outside, the ducting is not required and the
installation is similar to the one shown in the “INSTALLATION (VENT
OUTSIDE)” section
Carbon filter-not supplied
Activated carbon filter can be used to trap odors. Normally the activated carbon
filter should be changed every 3 to 6 months according to your cooking habits.
The installation procedure of activated carbon filter is as below:
1. Before installing or replacing the carbon filters, disconnect the mains
power to the unit.
2. Press the filter lock and remove the mesh filter.
3. Turn the carbon filter on both sides of the motor anti-clockwise. Replace
the carbon filters with the new carbon filters.
4. Place the mesh filter.
5. Connect the power supply to the wall socket.
NOTE:
Make sure the filter is securely locked. Otherwise, it would loosen and cause
danger.
When activated carbon filter attached, the suction power will be lowered.

(3) NOTICE OF INSTALLATION
The following rules must be strictly followed to obtain optimal air extraction:
• Keep flexible tube duct short and straight.
• Do not reduce the size or restrict the flexible tube duct.
• When using the flexible tube duct always install the pipe pulled taut to
minimize pressure loss.
• Failure to observe these basic instructions will reduce the performance and
increase noise level of the range hood.
• Any installation work must be carried out by a qualified electrician or
competent person.
•Do not connect the ducting system of the range hood to any existing ventilation
system which is being used for any other appliance, such as heating tube, gas
tube, air ducting tube.
•The angle of the bend of the flexible tube duct should not be less than 90º; you
must direct the pipe horizontally, or, alternatively, the pipe should go up from
the initial point and should be led to an outer wall.
•After the installation , make sure that the range hood is installed correctly to
avoid grease collection at one end.
•Ensure the flexible tube duct selected for installation complies with relevant
standards and is fire retardant.

(4) SAFETY WARNING
Do not try to use the range hood without the grease filters or if the filters are
excessively greasy!
Do not install above a gas hob with a high level grill.
Do not leave frying pans unattended during use because overheated fats or oil
smight catch fire.
Never leave naked flames under the range hood.
If the range hood is damaged, do not attempt to use.
Do not flambé under the range hood.
CAUTION: Accessible parts may become hot when used with cooking
appliances.
The minimum distance between the supporting surface for the cooking vessels
on the hob and the lowest part of the range hood is 65 cm. (When the range
hood is located above a gas appliance, this distance shall be at least 75 cm)
The air must not be discharged into a flue that is used for exhausting fumes
from appliances burning gas or other fuels. Range hoods and other cooking
fume extractors may adversely affect the safe operation of appliances burning
gas or other fuels (including those in other rooms) due to back flow of
combustion gases. These gases can potentially result in carbon monoxide
poisoning. After installation of a range hood or other cooking fume extractor,
the operation of open flued gas appliances should be tested by a competent
person to ensure that back flow of combustion gases does not occur.
Important! Always switch off the electricity supply at the mains during
installation.
The range hood must be installed in accordance with the installation instructions
and all measurements followed.
All installation work must be carried out by a competent person or qualified
electrician.
Please dispose the packing material carefully. Children are vulnerable to it.
Pay attention to the sharp edges inside the range hood especially during
installation and cleaning.
Make sure the ducting has no bends sharper than 90 degrees as this will reduce
the efficiency of the range hood.

Warning: Failure to install the screws or fixing device in accordance with these
instructions may result in electrical hazards.
Warning: Before obtaining access to terminals, all supply circuits must be
disconnected.
Always put lids on pots and pans when cooking on a hob.
When in extraction mode, air in the room is being removed by the range hood.
Please make sure that proper ventilation measures are being observed. The
range hood removes odours from room but not steam.
This range hood is for domestic use only.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Caution: The appliance and its accessible parts can become hot during operation.
Be careful to avoid touching the heating elements. Children younger than 8
years old should stay away unless they are under permanent supervision.
There shall be adequate ventilation of the room when the range hood is used at
the same time as appliances burning gas or other fuels.
There is a fire risk if cleaning is not carried out in accordance with the
instructions.
Regulations concerning the discharge of air have to be fulfilled.
Clean your appliance periodically by following the method given in the chapter
MAINTENANCE.
For safety reason, please use only the same size of fixing or mounting screw
which are recommended in this operating/installation manual.
Regarding the details about the method and frequency of cleaning, please refer
to maintenance and cleaning section in the operating/installation manual.
Cleaning and user maintenance shall not be made by children without
supervision.

When the range hood and appliances supplied with energy other than electricity
are simultaneously in operation, the negative pressure in the room must not
exceed 4 Pa (4 x 10-5 bar).
Warning: Danger of fire: do not store items on the cooking surfaces.
A steam cleaner is not to be used.
Never try to extinguish a fire with water, but switch off the appliance and then
cover flame e.g. with a lid or a fire blanket.

(5) USE
Electronic button
1. There are five buttons: (Low), (Mid), (High), (Lamp),
(Power).See picture above.
2. After connecting to power, indicator light will be lit, and the range hood will
enter standby mode. The indicator light will turn off automatically if no
function is selected.
3. Power on: Press power button once, its indicator light will light up, the
range hood works at low speed. Indicator light for low speed will be lit.
Press power button again to turn off, and its indicator light will turn off. All
the function operation of the range hood will be off, the range hood enters
into standby mode.
4. The speed buttons and lamp button can work separately, interdependently of
the power button. When a certain function button is pressed, the range hood
operates at that function status. Press (Power) button under any status, the
range hood will switch off.
5. Press lamp button once; lights will turn on. Indicator light of lamp
button and power button will light up. Press lamp button again to
turn the lights off. Indicator light of lamp button and power button
will turn off.
6. Press the (High) button once, motor runs on high speed, the indicator
light of high button and power button will turn on. Press high
button again and the motor will stop. Indicator light of high button and
power button will turn off.
7. Press the (Mid) button once, motor runs on middle speed, the indicator
light of middle button and power button will turn on. Press middle
button again and the motor will stop. Indicator light of middle button and
power button will turn off.
8. Press the (low) button once, motor runs on low speed, the indicator light
of low button and power button will turn on. Press low button again
and the motor will stop. Indicator light of low button and power button will
turn off.

9. Low speed, mid speed and high speed cannot work at the same time. When
range hood is on high speed, press low speed, it will turn to low speed at
once; when it is in low speed, press middle speed, it will turn to middle
speed immediately, and so on.
(6) MAINTENANCE
The cleaning of the carbon grease filter mesh
The filter mesh is made of high-density stainless steel. Do not use
corrosive detergent on it.
Keeping this filter clean will keep the range hood running correctly.
Strictly follow the guidelines below.
Method 1: Put the mesh into 40-50°C clean water, pour on detergent, and
soak for 2-3 mins. Wear gloves and clean with a soft brush. Do not apply
too much pressure, as the mesh is delicate and will damage easy.
Method 2: If instructed to do so, it can be put into a dishwasher, set the
temperature no greater than 60 degrees.
Notice of cleaning range hood
To protect the main body from corrosion over a long period of time, the
range hood should be cleaned with hot water plus non corrosive
detergent every two months.
Do not use abrasive detergent as they will damage the body.
Keep the motor and other electrical parts free from water, as this will
cause damage to the range hood.
Before cleaning the range hood remember to turn the power off.
The carbon filter shouldn’t be exposed to heat.
Don’t tear open the fixed bar around the carbon filter.
If the plug or cord is damaged, have a qualified person replace it.

(7) TROUBLE SHOOTING
Fault Cause Solution
Light on, but motor does not
work
The flue blocked Clear the blockage
The capacitor damaged Replace capacitor
The motor jammed bearing
damaged
Replace motor
Light does not work, motor
does not work
Beside the above mentioned, check the following:
Light damaged Replace lights
Power cord looses Connect the wires as per
the electric diagram
Liquid dripping
Air ventilation entrance are
not tightly sealed
Reseal
Leakage from the connection
of chimneys and cover
Take chimneys down and
seal
Shake of the body
The motor is not tightly
hanged
Lock the motor tightly
The body is not tightly
hanged
Fixed the body tightly
Insufficient suction
The distance between the
body and the ducting outlet is
too long
Readjust the distance
Too much ventilation from
open doors or windows
Choose a new place and
reinstall range hood
The machine inclines
The fixing screw not tight
enough
Tighten the hanging
screw to return back to
horizontal position
The hanging screw not tight
enough
Tighten the hanging
screw to return back to
horizontal position

Table of contents
Other Award Ventilation Hood manuals

Award
Award CH082-60 SI User manual

Award
Award PPS6031 User manual

Award
Award PPS863BS SI User manual

Award
Award Evo 580 User manual

Award
Award E-295 User manual

Award
Award CS1-903S User manual

Award
Award PPS1202 User manual

Award
Award PPS602 User manual

Award
Award CHO83-900 User manual

Award
Award E-231 Operating manual
Popular Ventilation Hood manuals by other brands

Gorenje
Gorenje S3 IHGC963S4X manual

KOBE
KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products
U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg
Kuppersberg DUDL 4 LX Technical Passport

Framtid
Framtid HW280 manual

Thermador
Thermador HGEW 36 FS installation manual