LR-3200 Reader Installation Sheet Version 1.0 Page 2 of 2
Procedure
Mounting the Reader
1. Fasten the mounting bracket to the pole, post, pedestal or wall. Leave space for the reader unit’s pan-
and-tilt adjustment.
2. Fasten the reader to the bracket with 2 ¼”-20 screws. AWID’s LR-MB-0-0 bracket includes fasteners.
3. Aim the reader toward the location of tags when they are attached to vehicles, for the planned reading
distance.
Wiring the LR-3200 (Figure 1)
1. Cut off the 10-pin connector from the end of the reader’s cable and discard the connector.
2. Check the power supply and cable(s) for power and data. Be certain that they meet AWID’s Specifications.
3. Connect Yellow to Black at the reader; Black and Red to the power supply; Green and White and Blue
to the controller.
4. Connect the readers Drain/Shield wire to the shields of all cables. Do not ground drain and shields –
they must float.
Yellow Wire - Arming circuit – If you are not using a arming circuit, connect the yellow wire to the
black wire at the reader permanently. For control of the reader’s RF transmission by a vehicle sensor,
connect the yellow wire to the relay contacts of the vehicle sensor (IR Sensor, Ground Loop). To disarm
the reader (no RF transmission), do not connect yellow wire.
Blue Wire - The blue wire is Wiegand Data Common. It connects where a proximity reader’s black wire would
connect on that reader port. The terminal is usually labeled “Ground”. If there is a “Data Common” terminal on
that reader port, connect the blue wire there instead of “Ground”.
Testing the Completed System
Once mounting and wiring is completed, power up the LR-3200 and check that the Red LED is illuminated.
Drive a vehicle/walk with an attached tag into the read-zone on the lane. Observe the Green LED activity light,
good reads are indicated by blinking from the Green LED.
For Additional Assistance
• • • In the U.S. call Technical Support, +1-408-825-1100 • • •
Talk with AWID Technical Support | | Website: www.awid.com ||E-mail: support@awid.com