X-Series aXess 700-560-01E
Advanced Door Configuration
Use “Advanced configuration”to enable or disable certain permissions, access types, and door settings.
Use the scroll button to scroll to “Config Door Adv”
Enter [door number][*]
Select the door’s options shown in the table below by scrolling and pressing [*] to enable ‘Y’ or disable ‘N’
Table 1: Door Configuration
Enable as an Arm reader to arm/disarm the alarm
Enable as an Access reader
Allow access if interface is disconnected from the system
Enable/Disable Door left Open Beep
Enable/Disable forced door monitoring
Door Switch Enabled –Enable this setting if a door contact is installed and you want to allocate a zone to the door to
monitor the door for forced open or held open situations.
Deny Entry if Armed –When enabled this option will disable the system from allowing anybody access through the
door if the door is allocated to the armed partition.
Arm/Disarm Reader –When enabled this option allows a tag allocated to an arm/disarm user code to arm or
disarm the system, depending on the state of the alarm, by holding the tag for three seconds in front of the
reader.
Access Reader –When disabled the reader will not function as an access reader. If the reader is an arm/disarm reader
and access is disabled it will allow the alarm to be armed or disarmed.
Note: The tag must have been allocated a valid alarm user code (defined below). The user code properties will define
the mode or type of arming.
Fire Door –If a door is enabled as a fire door and a fire alarm is triggered all fire doors will automatically unlock
Off Line Mode –if the interface loses communication with the panel due to a break in the communications bus
line, it will continue to operate as an access reader, but arm / disarm functionality will be disabled, and arm
status will not be shown.
Door Left Open Beep –If the door is monitored by a door magnet (Door Switch must be enabled) and left open for 30
seconds the reader will beep for 15 seconds to draw attention to the door being open. Disable if this feature is not
required
Forced Door Monitoring –This feature will raise an alarm if the door is opened without presenting an authorised tag
first. Door contact must be enabled and configured.
Master User Menu
Enter “Master User” menu:
Hold down [*] until beep
Enter Master user code [1] [2] [3] [4] [*]
aXess control menus are:
oMenu 32 “Add/Edit Card” by typing in the tag number
oMenu 33 “Add/Edit Card” by Swiping the tag
oMenu 34 “ Delete Card”
oMenu 35 “Delete Card by swipe”
oMenu 36 “View Transactions”
Option 32: Adding Access Tags
Menu option 32 allows the adding of access tags to the system or the editing of existing tags. The procedure to add a
tag is to enter the tag’s number, allocate it to a user code and any of the eight doors where the tag may be presented.
Enter [3] [2] [*]
oEnter the [card number] [*]
oSelect the doors by entering the [door number] [*] to enable ‘Y’ and by entering the [door number] [*] to disable ‘-’