Axis A1001 User manual

AXISA1001NetworkDoorController
ENGLISH
FRANÇAIS
DEUTSCH
ITALIANO
ESPANÕL
ò
ò
¨
¨
¾
¾
InstallationGuide

Liability
Everycarehasbeentakeninthepreparationofthis
document.PleaseinformyourlocalAxisofceofany
inaccuraciesoromissions.AxisCommunicationsABcannot
beheldresponsibleforanytechnicalortypographicalerrors
andreservestherighttomakechangestotheproductand
manualswithoutpriornotice.AxisCommunicationsAB
makesnowarrantyofanykindwithregardtothematerial
containedwithinthisdocument,including,butnotlimited
to,theimpliedwarrantiesofmerchantabilityandtnessfor
aparticularpurpose.AxisCommunicationsABshallnot
beliablenorresponsibleforincidentalorconseuential
damagesinconnectionwiththefurnishing,performance
oruseofthismaterial.Thisproductisonlytobeusedfor
itsintendedpurpose.
IntellectualPropertyRights
AxisABhasintellectualpropertyrightsrelatingto
technologyembodiedintheproductdescribedinthis
document.Inparticular,andwithoutlimitation,these
intellectualpropertyrightsmayincludeoneormoreof
thepatentslistedatwww.axis.com/patent.htmandoneor
moreadditionalpatentsorpendingpatentapplicationsin
theUSandothercountries.
ThisproductcontainssourcecodecopyrightAppleComputer,
Inc.,underthetermsofApplePublicSourceLicense2.0
(seewww.opensource.apple.com/apsl).Thesourcecodeis
availablefromhttps://developer.apple.com/bonjour/
EuipmentModications
Thiseuipmentmustbeinstalledandusedin
strictaccordancewiththeinstructionsgiveninthe
userdocumentation.Thiseuipmentcontainsno
user-serviceablecomponents.Unauthorizedeuipment
changesormodicationswillinvalidateallapplicable
regulatorycerticationsandapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPECandVAPIX
areregisteredtrademarksortrademarkapplicationsofAxis
ABinvariousjurisdictions.Allothercompanynamesand
productsaretrademarksorregisteredtrademarksoftheir
respectivecompanies.
Support
Shouldyoureuireanytechnicalassistance,pleasecontact
yourAxisreseller.Ifyouruestionscannotbeanswered
immediately,yourresellerwillforwardyourueriesthrough
theappropriatechannelstoensurearapidresponse.Ifyou
areconnectedtotheInternet,youcan:
•downloaduserdocumentationandsoftwareupdates
•ndanswerstoresolvedproblemsintheFAQdatabase.
Searchbyproduct,category,orphrase
•reportproblemstoAxissupportstaffbylogginginto
yourprivatesupportarea
•chatwithAxissupportstaff(selectedcountriesonly)
•visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/for
usefultrainings,webinars,tutorialsandguides.
RegulatoryInformation
Europe
ThisproductcomplieswiththeapplicableCEmarking
directivesandharmonizedstandards:
•ElectromagneticCompatibility(EMC)Directive
2004/108/EC.SeeElectromagneticCompatibility(EMC)
onpage2.
•LowVoltage(LVD)Directive2006/95/EC.Seeafety
onpage3.
•RestrictionsofHazardousSubstances(RoHS)Directive
2011/65/EU.SeeDisposalandRecyclingonpage3.
Acopyoftheoriginaldeclarationofconformitymaybe
obtainedfromAxisCommunicationsAB.SeeContact
Informationonpage3.
ElectromagneticCompatibility(EMC)
Thiseuipmenthasbeendesignedandtestedtofulll
applicablestandardsfor:
•Radiofreuencyemissionwheninstalledaccordingto
theinstructionsandusedinitsintendedenvironment.
•Immunitytoelectricalandelectromagneticphenomena
wheninstalledaccordingtotheinstructionsandused
initsintendedenvironment.
USA
Thiseuipmenthasbeentestedusingashieldednetwork
cable(STP)andfoundtocomplywiththelimitsfora
ClassBdigitaldevice,pursuanttopart15oftheFCC
Rules.Theselimitsaredesignedtoprovidereasonable
protectionagainstharmfulinterferenceinaresidential
installation.Thiseuipmentgenerates,usesandcan
radiateradiofreuencyenergyand,ifnotinstalledand
usedinaccordancewiththeinstructions,maycause
harmfulinterferencetoradiocommunications.However,
thereisnoguaranteethatinterferencewillnotoccurin
aparticularinstallation.Ifthiseuipmentdoescause
harmfulinterferencetoradioortelevisionreception,which
canbedeterminedbyturningtheeuipmentoffandon,
theuserisencouragedtotrytocorrecttheinterferenceby
oneormoreofthefollowingmeasures:
•Reorientorrelocatethereceivingantenna.
•Increasetheseparationbetweentheeuipmentand
receiver.
•Connecttheeuipmentintoanoutletonacircuit
differentfromthattowhichthereceiverisconnected.
•Consultthedealeroranexperiencedradio/TV
technicianforhelp.
Theproductshallbeconnectedusingashieldednetwork
cable(STP)thatisproperlygrounded.
Canada
ThisdigitalapparatuscomplieswithCANICES-3(ClassB).
Theproductshallbeconnectedusingashieldednetwork
cable(STP)thatisproperlygrounded.
Cetappareilnumériueestconformeàlanorme
CANNMB-3(classeB).Leproduitdoitêtreconnectéà
l'aided'uncâbleréseaublindé(STP)uiestcorrectement
misàlaterre.
Europe
ThisdigitaleuipmentfulllsthereuirementsforRF
emissionaccordingtotheClassBlimitofEN55022.The
productshallbeconnectedusingashieldednetworkcable
(STP)thatisproperlygrounded.
Thisproductfulllsthereuirementsforimmunity
accordingtoEN61000-6-1residential,commercialand
light-industrialenvironments.
Thisproductfulllsthereuirementsforimmunity
accordingtoEN61000-6-2industrialenvironments.
Thisproductfulllsthereuirementsforimmunity
accordingtoEN55024ofceandcommercialenvironments
Thisproductfulllsthereuirementsforimmunity
accordingtoEN50130-4residential,commercial,
light-industrialandindustrialenvironments.
Australia/NewZealand
ThisdigitaleuipmentfulllsthereuirementsforRF
emissionaccordingtotheClassBlimitofAS/NZSCISPR22.

Theproductshallbeconnectedusingashieldednetwork
cable(STP)thatisproperlygrounded.
Japan
この装置は、クラスB情報技術装置です。この装置
は、家庭環境で使用することを目的としています
が、この装置がラジオやテレビジョン受信機に近
接して使用されると、受信障害を引き起こすこと
があります。取扱説明書に従って正しい取り扱い
をして下さい。本製品は、シールドネットワーク
ケーブル(STP)を使用して接続してください。また
適切に接地してください。
Safety
ThisproductcomplieswithIEC/EN/UL60950-1,Safetyof
InformationTechnologyEuipment.Ifitsconnectingcables
areroutedoutdoors,theproductshallbegroundedeither
throughashieldednetworkcable(STP)orotherappropriate
method.
Thepowersupplyusedwiththisproductshallfulll
thereuirementsforSafetyExtraLowVoltage
(SELV)andLimitedPowerSource(LPS)accordingto
IEC/EN/UL60950-1.
DisposalandRecycling
Whenthisproducthasreachedtheendofitsusefullife,
disposeofitaccordingtolocallawsandregulations.For
informationaboutyournearestdesignatedcollectionpoint,
contactyourlocalauthorityresponsibleforwastedisposal.
Inaccordancewithlocallegislation,penaltiesmaybe
applicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbe
disposedoftogetherwithhouseholdorcommercialwaste.
Directive2012/19/EUonwasteelectricalandelectronic
euipment(WEEE)isapplicableintheEuropeanUnion
memberstates.Topreventpotentialharmtohumanhealth
andtheenvironment,theproductmustbedisposedofin
anapprovedandenvironmentallysaferecyclingprocess.
Forinformationaboutyournearestdesignatedcollection
point,contactyourlocalauthorityresponsibleforwaste
disposal.Businessesshouldcontacttheproductsupplierfor
informationabouthowtodisposeofthisproductcorrectly.
Thisproductcomplieswiththereuirementsof
Directive2011/65/EUontherestrictionoftheuseof
certainhazardoussubstancesinelectricalandelectronic
euipment(RoHS).
China
Thisproductcomplieswiththereuirementsofthe
legislativeactAdministrationontheControlofPollution
CausedbyElectronicInformationProducts(ACPEIP).
ContactInformation
AxisCommunicationsAB
Emdalavägen14
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
www.axis.com
SupportedReaders
Thislistofsupportedreadersissubjecttochangewithout
notice.ContactyourAxisresellerforinformationabout
supportedreaders.
ThisproductiscompatiblewithULListedWiegandaccess
controlreaders
ThisproductiscompatiblewiththefollowingRS485access
controlreaders:
AXISA4011-EReader
HIDiCLASS®RW100:6101CG40000,6101CGM0000,
6101CK40000,6101CK40002,6101CK40100,
6101CK403C0,6101CKM0000,6101CKM0002,
6101CKM0203;RW00:6111CG40000,6111CG400C0,
6111CGM0000,6111CK40000,6111CK4000Z,
6111CKM0000;RW400:6121CG40000,6121CGM0000,
6121CK40000,6121CK40003,6121CK40007-G3.0,
6121CK4000D-G3.0,6121CKM0000;R40:
6122CKP00P0,6122CKP05P0,6122CKP06P0;RWK400:
6131CG4020000,6131CK4000000,6131CK4000014,
6131CK4000300,6131CK4020000,6131CKM000000,
6131CKM000214;RK40:6132BKP00Q709-G3.0,
6132CKP000009,6132CKP000011,6132CKP000700-G3.0,
6132CKP000709-G3.0,6132CKP001009,6132CKP001011,
6132CKP00P000,6132CKP00P009,6132CKP00P709-G3.0,
6132CKP00Q709-G3.0,6132CKP030014,6132CKP060514,
6132CKP06P009,6132CKP06P609,6132CKP070209;
RW150:6141CG40000,6141CGM0000,6141CK40000,
6141CKM0000;R15:6142CKP000Z,6142CKP00P0,
6142CKP0100;RWKL550:6171BK4000000,
6171BK4000009,6171BK4000014,6171BK4000214,
6171BK4000500,6171BK4040Z14,6171BK4060000,
6171BK4060209,6171BK4060Z09,6171BK4061000,
6171BKM000000,6171BKM000200,6171BKM000300,
6171BKM040400;RWKLB575:6181BK4000000,
6181BK4000009,6181BK4000014,6181BK4000022,
6181BK406C009;
HIDSmartid®:8031DSAP
HIDpivClass®R10-H:900LHRNAK00000,
900LHRTAK00000,900NHRNAK00000,900NHRTAK00000,
900PHRNAK00000,900PHRTAK00000,910LHRNAK00000,
910LHRTAK00000,910NHRNAK00000,910NHRTAK00000,
910PHRNAK00000,910PHRTAK00000,920LHRNAK00000,
920LHRTAK00000,920NHRNAK00000,920NHRTAK00000,
920PHRNAK00000,920PHRTAK00000,921LHRNAK00000,
921LHRTAK00000,921NHRNAK00000,921NHRTAK00000,
921PHRNAK00000,921PHRTAK00000;RPKCL40-P:
923LPRNAK00000,923LPRTAK00000,923NPRTAK00000,
923PPRNAK00000,923PPRTAK00000
AptiTM:M11,MTK15,MTMSK15,MT15,MTMS15
ForinformationaboutwhichcompatibleRS485access
controlreadershavebeenveriedbyUL,seeRequirements
forULComplianceonpage4.

AXISA1001NetworkDoorController
RequirementsforULCompliance
ThissectioncontainsinformationandinstructionsreuiredforULcompliance.Tomakesurethe
installationisULcompliant,followtheinstructionsbelowinadditiontothegeneralinformation
andinstructionsprovidedthroughoutthisdocument.Incaseswherepiecesofinformation
contradicteachother,thereuirementsforULcompliancealwaysreplacegeneralinformation
andinstructions.
upportedReaders
•CompatibilitywiththefollowingRS485readershasbeenveriedbyUL:HIDiClassRK40,
HIDSmartID8031DSHM,andAptiQMTMSK15.
afetyInstructions
•TheAxisproductshallbeinstalledandservicedbyafactorytrainedprofessional.
•TheAxisproductshallbeinstalledwithintheprotectedpremises(securedarea).
•TheAxisproductshallbemountedindoors.Outdoorusehasnotbeenevaluatedor
approvedbyUL.
•AllinterconnectingdevicesshallbeULListedandClass2powerlimited.
•AllwiringmethodsshallbeperformedinaccordancewithNFPA70,localcodesand
authoritieshavingjurisdiction.
•WhentheAxisproducthasreachedtheendofitsusefullife,disposeofitaccording
tolocallawsandregulations.Theproductshouldnotbedisposedoftogetherwith
householdorcommercialwaste.SeeDisposalandRecyclingonpage3.
•Battery
-The3.0VlithiumbatteryusedbytheAxisproductisaULRecognized
component.(Type:BR2032,diameter:20mm(0.78in),Axispartnumber:
38118,manufacturers:Rayovac,Panasonic,Renata.)
-Usersshallnotreplacethebattery.Ifthebatteryneedsreplacing,
afactorytrainedserviceprofessionalshallcontactAxissupport
atwww.axis.com/techsupforassistance.
-Usedbatteriesshallbedisposedofaccordingtolocallawsandregulations,
whichmayvaryfromstatetostate.WasteBRlithiumcellsareneitherlisted
norexemptedfromtheUSEPAhazardouswasteregulations.WasteBRlithium
batteriescanbeconsideredreactivehazardouswasteifthereisasignicant
amountofunreacted,orunconsumedlithiumremaining.Forinformation
abouthowtodisposeofusedlithiumbatteries,contactyourlocalauthority
forwastedisposal.
pecications
•OperatingConditions
-Temperaturesbeyond0°Cto49°C(32°Fto120°F)hasnotbeenveried
aspartofUL294.
•WireArea
4

AXISA1001NetworkDoorController
-ULListedorR/CAWMwiresthathaveanconductorgaugerangeof
AWG22–14shallbeused.
-Theminimumconductorgaugeforconnectionbetweenthepowersourcing
euipment(PSE)orpowerinjectorandthepowereddevice(PD)is26AWG.
•Connectors
-ThisproductisnotintendedforoutsidewiringascoveredbyArticle800inthe
NationalElectricalCode,NFPA70.
-PowerConnector–ForULsecurityapplications,theproductshallbepowered
byaUL294ListedorUL603ListedClass2low-voltagepowerlimitedpower
supplythatiscapableof4hoursofstandbypower.
-NetworkConnector–PoweroverEthernet(PoE)shallbesuppliedbyaUL294
ListedClass2powerlimitedinjectorthatprovides44–57VDC,15.4Wand4
hoursofstandbypower.CompliancewithIEEE802.3(atoraf)specications
hasnotbeenveriedaspartofUL294/B.
-TamperingAlarmPinHeader–TocomplywithUL294/7.2.1(Enclosure),the
tamperingalarmshallbeconnectedtoasoundalarm.
•ystemConsiderations
-TheAxisproduct,whetheritisastandalonedoorcontrollerorasystemof
doorcontrollers,shallnotimpairtheintendedoperationofthepanichardware
usedinconjunctionwithit.
•WallandCeilingMount
-IfusingajunctionboxtomounttheAxisproduct,thejunctionboxshallbe
ULListed.
•AssignanIPAddress
-ThefunctionalityofAXISCameraManagement,seepage36,hasnotbeen
evaluatedbyUL.
•MaintenanceInstructions
-Formaintenanceinstructions(somestepsreuireaccesstotheproduct’s
webpages),seepage40.ForinformationabouthowtoconguretheAxis
productusingtheproduct’swebpages(AXISEntryManager),seetheUser
Manual.
5
ENGLISH

6

AXISA1001NetworkDoorController
SafetInformation
ReadthroughthisInstallationGuidecarefullybeforeinstallingtheproduct.KeeptheInstallation
Guideforfuturereference.
HazardLevels
DANGERIndicatesahazardoussituationwhich,ifnotavoided,willresultin
deathorseriousinjury.
WARNINGIndicatesahazardoussituationwhich,ifnotavoided,couldresult
indeathorseriousinjury.
CAUTIONIndicatesahazardoussituationwhich,ifnotavoided,couldresult
inminorormoderateinjury.
NO NO
NOTICE TICE
TICEIndicatesasituationwhich,ifnotavoided,couldresultindamage
toproperty.
OtherMessageLevels
ImportantIndicatessignicantinformationwhichisessentialfortheproduct
tofunctioncorrectly.
NoteIndicatesusefulinformationwhichhelpsingettingthemostout
oftheproduct.
7
ENGLISH

AXISA1001NetworkDoorController
SafetInstructions
WARNING
•TheAxisproductshallbeinstalledbyatrainedprofessional.
NO NO
NOTICE TICE
TICE
•TheAxisproductshallbeusedincompliancewithlocallawsandregulations.
•TousetheAxisproductoutdoors,orinsimilarenvironments,itshallbeinstalledinan
approvedoutdoorhousing.
•StoretheAxisproductinadryandventilatedenvironment.
•AvoidexposingtheAxisproducttoshocksorheavypressure.
•Donotinstalltheproductonunstablebrackets,surfacesorwalls.
•UseonlyapplicabletoolswheninstallingtheAxisproduct.Excessiveforcecouldcause
damagetotheproduct.
•Donotusechemicals,causticagents,oraerosolcleaners.
•Useacleanclothdampenedwithpurewaterforcleaning.
•Useonlyaccessoriesthatcomplywithtechnicalspecicationoftheproduct.Thesecanbe
providedbyAxisorathirdparty.
•UseonlysparepartsprovidedbyorrecommendedbyAxis.
•Donotattempttorepairtheproductbyyourself.ContactAxissupportoryourAxis
resellerforservicematters.
Transportation
NO NO
NOTICE TICE
TICE
•WhentransportingtheAxisproduct,usetheoriginalpackagingoreuivalenttoprevent
damagetotheproduct.
Battery
TheAxisproductusesa3.0VBR/CR2032lithiumbatteryasthepowersupplyforitsinternal
real-timeclock(RTC).Undernormalconditionsthisbatterywilllastforaminimumofveyears.
LowbatterypoweraffectstheoperationoftheRTC,causingittoresetateverypower-up.When
thebatteryneedsreplacing,alogmessagewillappearintheproduct’sserverreport.Formore
informationabouttheserverreport,seetheproduct´ssetuppagesorcontactAxissupport.
Thebatteryshouldnotbereplacedunlessreuired,butifthebatterydoesneedreplacing,contact
Axissupportatwww.axis.com/techsupforassistance.
8

AXISA1001NetworkDoorController
WARNING
•Riskofexplosionifthebatteryisincorrectlyreplaced.
•ReplaceonlywithanidenticalbatteryorabatterywhichisrecommendedbyAxis.
•Disposeofusedbatteriesaccordingtolocalregulationsorthebatterymanufacturer's
instructions.
9
ENGLISH

10

AXISA1001NetworkDoorController
InstallationGuide
ThisInstallationGuideprovidesinstructionsforinstallingAXISA1001NetworkDoorController
onyournetwork.Forotheraspectsofusingtheproduct,seetheUserManualavailableat
www.axis.com
InstallationSteps
1.Makesurethepackagecontents,toolsandothermaterialsnecessaryfortheinstallation
areinorder.Seepage11.
2.Studythehardwareoverview.Seepage13.
3.Studythespecications.Seepage18.
4.Installthehardware.Seepage26.
5.Accesstheproduct.Seepage34.
PackageContents
•AXISA1001NetworkDoorController
•Cabletie(4x)
•Coverscrew
•6-pinplugconnector(5x)(pluggedintoterminalconnectors)
-ReaderI/O(blue)
-ReaderI/O(red)
-Readerdata(white)
-Readerdata(yellow)
-Power&Relay(orange)
•4-pinplugconnector(5x)(pluggedintoterminalconnectors)
-Audio(white)
-Auxiliary(yellow)
-Doorin(blue)
-Doorin(red)
-Powerlock(orange)
•2-pinplugconnector(pluggedintoterminalconnector)
-Power(black)
•Printedmaterials
-GraphicalInstallationGuide
-Extraserialnumberlabel(2x)
-AVHSAuthenticationkey
11
ENGLISH

AXISA1001NetworkDoorController
RecommendedTools
•Drill–ifmountingonwallorceiling
•Screwdriver–ifmountingonwallorceiling
•Slottedscrewdriver–foropeningthecover
•Torxscrewdriver(T10)–fortighteningthecoverscrew
•Wirestrippingtool
12

AXISA1001NetworkDoorController
HardwareOverview
1
2
5
4
8
6
7
3
Frontandback:
1Cover
2Coverscrew
3Coverremovalslot
4Base
5DINclip–upper
6Tamperingalarmswitch–back
7DINclip–lower
13
ENGLISH

AXISA1001NetworkDoorController
8Partnumber(P/N)&erialnumber(/N)
1
2
3
4
5
6
7
8
910
11
12
I/Ointerface:
1Readerdataconnector(READERDATA1)
10Readerdataconnector(READERDATA2)
3ReaderI/Oconnector(READERI/O1)
8ReaderI/Oconnector(READERI/O2)
4Doorconnector(DOORIN1)
7Doorconnector(DOORIN2)
6Auxiliaryconnector(AUX)
5Audioconnector(AUDIO)(notused)
Externalpowerinputs:
2Powerconnector(DCIN)
12Networkconnector(PoE)
Poweroutputs:
9Powerlockconnector(LOCK)
11Power&Relayconnector(PWR,RELAY)
14

AXISA1001NetworkDoorController
1
234
5
6
7
8
9
1011
12
13
LEDindicators,buttonsandotherhardware:
1PowerLEDindicator
2tatusLEDindicator
3NetworkLEDindicator
4Reader2LEDindicator(notused)
5Reader1LEDindicator(notused)
6Tamperingalarmpinheader–front(TF)
7Tamperingalarmpinheader–back(TB)
8LockLEDindicator
9LockLEDindicator
10Tamperingalarmsensor–front
11Dcardslot(microDHC)(notused)
12Controlbutton
13Partnumber(P/N)&erialnumber(/N)
15
ENGLISH

AXISA1001NetworkDoorController
LEDIndicators
LEDColorIndication
GreenSteadyforconnectiontoa100MBit/snetwork.Flashesfor
networkactivity.
AmberSteadyforconnectiontoa10MBit/snetwork.Flashesfornetwork
activity.
Network
UnlitNonetworkconnection.
GreenSteadygreenfornormaloperation.
AmberSteadyduringstartupandwhenrestoringsettings.
Status
RedSlowashforfailedupgrade.
GreenNormaloperation. Power
AmberFlashesgreen/amberduringrmwareupgrade.
GreenSteadywhennotenergized.
RedSteadywhenenergized.
Lock
UnlitFloating.
Note
•TheStatusLEDcanbeconguredtoashwhileaneventisactive.
•TheStatusLEDcanbeconguredtoashforidentifyingtheunit.GotoSetup>
AdditionalControllerConguration>SystemOptions>Maintenance.
ConnectorsandButtons
Forspecicationsandoperatingconditions,seepage18.
I/OInterface
ReaderDataConnector
Two6-pinterminalblockssupportingRS485andWiegandprotocolsforcommunicationwiththe
reader.Forspecications,seepage19.
ReaderI/OConnector
Two6-pinterminalblocksforreaderinputandoutput.Inadditiontothe0VDCreferencepoint
andpower(DCoutput),thereaderI/Oconnectorprovidestheinterfaceto:
•Digitalinput–Forconnecting,forexample,readertamperingalarms.
16

AXISA1001NetworkDoorController
•Digitaloutput–Forconnecting,forexample,readerbeepersandreaderLEDs.
Forspecications,seepage20.
DoorConnector
Two4-pinterminalblocksforconnectingdoormonitoringdevicesandreuesttoexit(REX)devices.
Forspecications,seepage21.
AuxiliaryConnector
4-pincongurableI/Oterminalblock.Usewithexternaldevices,incombinationwith,forexample
tamperingalarms,eventtriggeringandalarmnotications.Inadditiontothe0VDCreference
pointandpower(DCoutput),theauxiliaryconnectorprovidestheinterfaceto:
•Digitalinput–Analarminputforconnectingdevicesthatcantogglebetweenanopen
andclosedcircuit,forexamplePIRsensorsorglassbreakdetectors.
•Digitaloutput–Forconnectingexternaldevicessuchasburglaralarms,sirensorlights.
ConnecteddevicescanbeactivatedbytheVAPIX®applicationprogramminginterfaceor
byanactionrule.
Forspecications,seepage21.
ExternalPowerInputs
NO NO
NOTICE TICE
TICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnecting
theproducttothenetworkshallbeintendedfortheirspecicuse.Makesurethatthe
networkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For
informationaboutregulatoryreuirements,seeElectromagneticCompatibility(EMC)on
page2.
PowerConnector
2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimited
powersource(LPS)witheitheraratedoutputpowerlimitedto≤100Woraratedoutputcurrent
limitedto≤5A.Forspecications,seepage22.
NetworkConnector
RJ45Ethernetconnector.SupportsPoweroverEthernet(PoE).Forspecications,seepage22.
PowerOutputs
PowerLockConnector
4-pinterminalblockforconnectingoneortwolocks.Thelockconnectorcanalsobeusedtopower
externaldevices.Forspecications,seepage23.
Power&RelayConnector
6-pinterminalblockforconnectingpowerandthedoorcontroller’srelaytoexternaldevicessuch
aslocksandsensors.Forspecications,seepage23.
17
ENGLISH

AXISA1001NetworkDoorController
ButtonsandOtherHardware
TamperingAlarmPinHeader
Two2-pinheadersfordisconnectingthefrontandbacktamperingalarms.Forspecications,
seepage24.
ControlButton
Thecontrolbuttonisusedfor:
•Resettingtheproducttofactorydefaultsettings.Seepage39.
•ConnectingtoanAXISVideoHostingSystemserviceorAXISInternetDynamicDNS
Service.Formoreinformationabouttheseservices,seetheUserManual.
Specications
OperatingConditions
TheAxisproductisintendedforindooruse.
ClassicationTemperatureHumidity
IEC60721-4-3Class3K3,
3M30°Cto50°C
(32°Fto122°F)20–85%RH(non-condensing)
PowerConsumption
NO NO
NOTICE TICE
TICE
UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheithera
ratedoutputpowerlimitedto≤100Woraratedoutputcurrentlimitedto≤5A.
PowersupplyMaximumloadonoutputs
PoweroverEthernetIEEE802.3af/802.3atType1Class3,
44–57VDC
7.5W
10–30VDC,max26W14W
Forconnectorspecications,seePowerConnectoronpage22andNetworkConnectoronpage22.
18

AXISA1001NetworkDoorController
WireArea
NO NO
NOTICE TICE
TICE
Eachwireshallhaveanareathatcorrespondstoanconductorgaugerangeof
AWG28–16(CSA)orAWG22–14(cUL/UL).Selectcablesincompliancewithyourlocal
regulations.
AWGDiametermm(in)Areamm2
28–160.321–1.29(0.0126–0.0508)0.0810–1.31
22–140.644–1.63(0.0253–0.0641)0.326–2.08
Connectors
Forinformationabouttheconnectors’positions,seeHardwareOverviewonpage13.
Forconnectiondiagramsandinformationaboutthehardwarepinchartgeneratedthroughthe
hardwareconguration,seeConnectionDiagramsonpage24andConguretheHardwareon
page27.
Thefollowingsectiondescribestheconnectors’technicalspecications.
ReaderDataConnector
6-pinterminalblocksupportingRS485andWiegandprotocolsfor
communicationwiththereader.
TheRS485portssupport:
•Two-wireRS485halfduplex
•Four-wireRS485fullduplex
TheWiegandportssupport:
•Two-wireWiegand
FunctionPinNotes
A-1
RS485
B+2
ForfullduplexRS485
ForhalfduplexRS485
A-3
RS485
B+4
ForfullduplexRS485
ForhalfduplexRS485
19
ENGLISH

AXISA1001NetworkDoorController
D0(Data0)5
Wiegand
D1(Data1)6
ForWiegand
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
ReaderI/OConnector
6-pinterminalblockfor:
•Auxiliarypower(DCoutput)
•DigitalInput
•DigitalOutput
•0VDC(-)
Pin3onthereaderI/Oconnectorscanbesupervised.Iftheconnection
isinterrupted,aneventisactivated.Tousesupervisedinputs,install
endoflineresistors.Usetheconnectiondiagramforsupervisedinputs.
Seepage26.
FunctionPinNotesSpecications
0VDC(-)10VDC
DCoutput2Forpoweringauxiliaryeuipment.
Note:Thispincanonlybeusedas
powerout.
12VDC
Maxload=300mA
Digitalinput—Connecttopin1to
activate,orleaveoating(unconnected)
todeactivate.
0tomax40VDC
Congurable
(Inputor
Output)
3–6
Digitaloutput—Connecttopin1to
activate,orleaveoating(unconnected)
todeactivate.Ifusedwithaninductive
load,e.g.arelay,adiodemustbe
connectedinparallelwiththeload,for
protectionagainstvoltagetransients.
0tomax40VDC,open
drain,100mA
20
Other manuals for A1001
8
Table of contents
Languages:
Other Axis Controllers manuals
Popular Controllers manuals by other brands

Sensys Networks
Sensys Networks VDS240 installation guide

Banner
Banner XS26-2 Series manual

Pratissoli
Pratissoli PN2S-500 operating instructions

Xvent
Xvent ELEMENTAIR E - MARK I Quick manual

SOMFY
SOMFY animeo IB+ 4 AC Motor Controller WM 100-120 V... installation guide

Aprilaire
Aprilaire IN72 owner's manual