The following chart indicates the E-Series Ultrasonic meter conditions when connected to Badger Meter ORION Cellular
and Fixed/Migratable (SE/ME) AMR/AMI endpoints.
The chart does not apply to ORION Classic (CE) or GALAXY endpoints. The E-Series will display the status indicators, but
Reverse Flow, Suspected Leak and 30 Day No Usage alarms are determined by the endpoint radio and are not obtained from the
Ultrasonic meter.
Status
Indicator Icon Alarm Description
High Resolution
with ORION Cellular,
Fixed Network (SE)
or Migratable (ME)
Encoder Protocol
with ORION Cellular,
Fixed Network (SE)
or Migratable (ME)
RTR with
ORION Fixed Network
(SE) or Migratable
(ME)
Meter
functioning
correctly
Meter operating correctly.
Normal operation. Indicator not sent to endpoint.
Meter alarm Several potential conditions may exist,
including:
• Empty pipe: “err” displays on LCD.
Last known good read is displayed.
Alarm clears when pipe is filled.
• Low Temperature limits exceeded:
meter continues to operate but
outside specified accuracy range.
Alarm clears after 60 days unless
alarm condition continues.
• Maximum flow rate is exceeded.
No consumption is displayed
until back within specified flow
range. Both the meter functioning
correctly and the meter alarm are
active. Alarms clear after 60 days
unless alarm condition continues.
• Other meter or sensor issue: last
known good read is displayed and
flow rate displays zero (0) flow.
Alarm clears after 60 days unless
alarm condition continues.
Consumption data is
sent to the endpoint.
Meter alarm is
also sent.
Meter alarm is sent to
the endpoint.
NOTE: No
consumption data
is sent to endpoint
when the alarm
is active.
Consumption data is
sent to the endpoint,
except when
Exceeding Max Flow
alarm is set.
Reverse flow The meter detects reverse flow and
triggers the reverse flow alarm icon
on the E-Series display. The alarm
remains active for 60 days. The alarm
automatically clears after 60 days if the
condition has not recurred.
Meter detects reverse
flow and sends alarm
message to
the endpoint.
Meter does not
send the alarm. The
endpoint detects and
reports the reverse
flow and will report
the read exactly how
it is received.
No alarm condition
reported by the
endpoint will only
record positive,
forward flow.
Suspected
leak
Meter detects 24 hours without one
15-minute interval of no ow. The
alarm clears automatically when a
15-minute no-ow interval occurs.
Meter detects
suspected leak and
sends alarm message
to the endpoint.
Meter does not send the alarm. The endpoint
detects continuous consumption over a
24-hour period and reports suspected leak.
30 day no
usage
No measured flow in past 30 days.
The alarm automatically clears once
flow occurs.
Meter detects 30 day
no usage and sends
alarm to the endpoint.
Meter does not send the alarm. The endpoint
detects no change in consumption over a
30-day period and reports 30 day no usage.
End of life
battery
indicator
Indicated battery life based on pre-
calculated consumption. Alarm is
activated after 19 years and 6 months
and does not clear.
Meter sends alarm to
the endpoint.
Meter does not send the alarm.
NOT:NFor meters manufactured prior to 5/2017, the meter alarms and reverse flow alarm were set to 35 days.