Technical features
Power supply
Motor voltage
Motor power
Absorbed power
Motor rpm
Opening time BRL 2.5, 4, 5-6 mt slow
Opening time BRL 4 mt fast
Opening time BRL 2,5 mt fast
Duty cycle
Backup batteries
Cycles with batteries
Operating temp.
Measures (with arm installed)
Weight
230Volt 50/60Hz
24 Vcc
90 W
3,7 A
1800 rpm
8 seconds
7 seconds
4 seconds
80%
2 x 12 Vcc 5,2 Ah
50 minimum
-20°/ +50°C
h100 x 30 x 35 cm
50 Kg
Safety
standard
specifications
motors in areas
saturated with
explosives mixtures!
WARNING
Moving
gears!
WARNING
Keep safety distance!
2
IP protection class
IP 44
Electromechanical road barriers for passages from 2,5 mt up to 6 mt.
with low voltage electric motors for intensive use and extensible
aluminium round arm. The cabinet treated with electrophoresis and
painted in epoxy powder can be used in any climatic condition.
Available with mobile foot and articulated arm.
WARNING
Electric shock!
Do not install
WARNING
Tools needed
for the
installation
of the motor
Precautions required to install
the motoreducer
Before installing the motor always read all the manual.
The manual not only explain how to install the motor in the correct way
but explain also which safety standard the gate must respect.
230Volt 50/60Hz
230Volt 50/60Hz
300 W
1,3 A
1400 rpm
9 seconds
50%
-20°/ +50°C
h100 x 30 x 35 cm
50 Kg
24 Vcc 230Vac
-
-
IP 44
-
-

Assembling procedure
1) Prepare a cement platform perfectly straight and level to fix the
body. On the center of this platform place the plastic pipes for the
electrical wiring and the fixing plate .
3) Fix the body on the fixing plate.
4) Install the arm in the arm support (see pag. 9/10).
5) Unlock the motoreducer (pag. 5) and set the spring using the
regulation screw placed below the spring. Check that the arm
movement is smooth and uniform. (see pag. 11 )
.
6) Lock the motoreducer (pag 5), and proceed with the electrical
wiring (see attached manual).
7) Verify that the arm stops in horizontal position (closing)
and vertical position (opening).
If this position is to be adjusted, check the limitswitch magnets
and the rubber vibration dumpers .(see pag.11)
217
130
Hole diameter 15 mm
Screws diameter 12 mm
Are advise to be used
Ø0
5
FIG.2
3
Antenna
Barrier
RX
Photocell
AREA TO BE PROTECTED WITH SAFETY DEVICE
TX Photocell
Fork
Arm
BEFORE PROCEEDING WITH INSTALLATION
MAKE SURE THAT THE OPERATING FIELD
OF THE BARRIER IS FREE FROM OBSTACLES
AND ELECTRIC CABLES.
TX
RXRX
Magnetotermic
switch
Differential switch
CABINET FIXING
Flashing light
Cement
platform
Fixing screw
Plastic pipe
for electrical
Fixing plate
wiring
FIG. 1
230V
0V
ATTENTION:
BAME s.r.l. is liable only for the individual articles produced and sold by BAME. The gate with the
motor it’s considered a machine and must respect the machinery directives, the installer must verify
the safety of the gate with the motor and is liable for any damage due to a poor installation.
BAME is not liable for any damage depending on modifications to any particular: electrical, electronic
or mechanical done by other persons without prior consent by BAME s.r.l..
BAME is not liable for any damage depending on accessories, electronic control boards and
photocells without BAME trademark or for the use of these parts without prior consent by BAME s.r.l..
2) Use suitable screws to fix the plate on the platform.
DO NOT REGULATE
THE BARRIER WITH
THE MOTOR IN
FUNCTION!!
FIG.3

LEFT
BARRIER
RIGHT
BARRIER
YELLOW YELLOW
GREEN GREEN
ONLY BRL 230 V ONLY BRL 230 V
4
PART. A
PART. B
Right barrier with
the arm in vertical
position
FIG. 4
PART. A
PART. C
PART. D
PART. F
PART. E
Operations to transform a right barrier into
a left barrier
1. Disconnect the power supply of the barrier
2. Unlock the motor
3. Place the barrier in the opening position
4. Lock the motor
5. Remove the arm if installed
(see ARM REMOVAL pag.10)
6. Unscrew completely the regulation nut of the
spring (PART: F)
7. Remove the articulated joint (PART:D) of the
balancing lever (PART:B )and place it on the
true in the opposite side
8. Insert the regulation screw in the left hole and
screw the regulation nut of the spring
9. Tighten the screw on the balancing lever
10. Check the proper balancing of the arm, the
regulation of the limitswitches and the
anti-vibration rubber dumper ( see pag.11)
FIG.5

Emergency unlocking system:
WARNING: DO NOT UNLOCK THE
BARRIER WITHOUT THE ARM.
THERE IS A MORTAL DANGER IF
THE BARRIER IS UNLOCKED
WITHOUT THE ARM.
using the key in the kit (fig. 6)
2. On the motor is present an
unlocking knob (fig. 7)
3. To unlock the barrier turn the
knob clockwise (fig. 7)
4. To lock the barrier turn the knob
anticlockwise
5. Replace the protection panel
and lock it with the key
FIG. 6
FIG. 7
5
ATTENTION:
THIS SHEET
MUST BE
CONSIGNED
TO THE CLIENT
ATTENTION:
THE CUSTOMER
MUST KEEP
THIS SHEET
TOGETHER WITH
THE UNLOCKING
KEY IN A
SAFE PLACE.
THE PLACE
WHERE THE KEY
IS STORED MUST
BE ACCESSIBLE
ALSO IN CASE
OF POWER
FAILURE
ATTENTION:
INFORM ALSO
OTHER USERS
OF THE
AUTOMATION
ABOUT THE
PLACE WHERE
THE KEY AND
THIS SHEET
ARE STORED.
1. Open the protection panel

Safety checks
IMPACT
CRUSHING
HOOKING
DRAGGING
SHEARING
CUTTING
Checks:
The ruggedness and the fastening of the structure is adeguate.
The swing can not fall in the ground.
The threshold of the gate it’s modeled not to create hindrance.
Limit switch are installed and verified.
The moving parts are equipped with adeguate protections installed in
compliance with the safety standards.
The torque regulation can be changed only by specialized personnel,
operating on the control board in compliance with the instructions from
the manifacturer.
The gate with the motor is supplied with an emergency release system.
The client have been supplied with information about the emergency
release system.
Possible risks:
Mark for each risk the solution adopted.
(Possible solutions : 1-only manual operations, 2-sensitive edges,
3-photocells, 4-swing stoppers, 5-torque limiter, 6-surface modelling,
7-footboards, 8-radar, 9-acustic signal, 10-visual signal, 11-markings,
12-isolation, 13-protection net, 14-……………………......................…,
15-……………………......................…)
Electrical risks:
CE markings are present in compliance with the directive
BT(73/23/CEE).
All electrical connections are made in compliance with standard
specifications, also according to the manufacturer manual.
The remote controls are compliant with the directive R&TTE(99/5/CE).
Components are marked CE, according to directive EMC(89/336/CEE).
Safety and reliability of the motor and control devices:
Controls are verified with the movement of the gate, according with the
manifacturer manual.
All the control device are installed in an accesible position and they are
easily visible.
The motor is compliant with the standard specification EN12453.
All the presence and motion sensor are working according with the
standard specification EN12445.
impact cutting lifting shearing
dragging hooking crushing
6

Declaration of conformity
(must be filled by the installer)
DECLARATION OF CONFORMITY “A”
The undersigned
Name: ........................................................................................................
Surname:.....................................................................................................
responsible of the installation of the system declare that the product:
Gate type: ................................................................
Address: ...........................................................................
...........................................................................
satisfies all the technical regulations applicable to the product within
the scope of Council Directives 73/23/EEC, 89/336/EEC, 98/37/EEC
and subsequent modifications.
Furthermore declare that the following standard specifications have been
applied:
EN12453/EN12445 Safety for motorised doors and gates, industrial,
commercial and residential - Requisites and classification - Test methods
EN12604/EN12605 Mechanical aspects for doors and gates, industrial,
commercial and residential – Requisites and classification – Test methods
CEI 64/8 electrical plant with nominal tension not over 1000 VAC and
1500 VDC
Notes: ...................................................................................................
...................................................................................................
...................................................................................................
Place:..................................................................................................
...................................................................................................
Date: ...................................................................................................
Signature:........................................
7

Declaration of conformity
DECLARATION OF CONFORMITY “B”
BAME srl
Via Leonardo da Vinci, 23
46020, San Giacomo Segnate (MN)
Italia
declare that the product
motoreducer for sliding gates, see the instruction manual for compatible gates
BARRIERA
satisfies all the technical regulations applicable to the product within the scope of
Council Directives:
MACHINERY DIRECTIVE 98/37/CEE AND SUBSEQUENT MODIFICATIONS.
DIRECTIVE EMC 89/336/CEE.
DIRECTIVE BT 73/23/CEE AND 93/68/CEE.
IS FORBIDDEN TO PUT INTO SERVICE THE DEVICE OF THIS DECLARATION BEFORE
THE PRODUCT OF THE DECLARATION “A” HAS BEEN DECLARED IN COMPLIANCE
WITH THE SPECIFICATIONS STANDARD.
San Giacomo Segnate, 01/01/2010
Baraldini Silvano
BAME srl
8

1. Fix the first element of the arm between the two arm supports tightening
2. Loosen the screws of the arm support and let the arm slide down on the floor
WARNING: NEVER REMOVE THE ARM IN HORIZONTAL
Safety screw
5. Release the arm and make sure that the arm does not go up by itself
POSITION WITH THE SPRING UNDER TENSION
9
ARM D75x2x3MT
4,8 x 16
NUTS M8
6. Add other pieces of the arm as shown in the following page
7. Unlock the motor and check if the arm movement is uniform
3. Remove the arm support keeping the arm in vertical position
DANGER OF FATAL INJURIES
1. Move the arm in the opening position and lock the motor
ARM SUPPORT
Arm fixing
8. Adjust the spring tension (pag.11)
SCREWS
M8x16
4. Put the arm on the floor carefully
the screws and the self-locking nutsM8x16 M8
2. Unlock the motor (page 5)
3. Put down the arm carefully
Arm removal
4. Lock the motor
BARRIER
OPERATING FIELD OF
BAME,
THE WEIGHT SCHEME
IT IS ADVISED TO USE
ORIGINAL PROFILES.
NEVER ENTER THE
THE ARM DURING
OR NORMAL USE.
PLEASE CONSIDER
AS SHOWN IN THE
FOLLOWING PAGE.
INSTALLATION
DIFFERENT ARM
FROM THE ONE
YS BAME
SUPPLIED BY
WARNING:
IF USING A
ALWA
FIG.8

Min 3,80 mt (transit width 3,5 mt) - Max 4,30 mt (transit width 4 mt)
2,5 mt Single round arm
3 mt (transit width 2,70 mt)
3 mt
3 mt
1
1
1
SCREWS
SCREWS
2
2 mt
4 mt
3
Assembling round alluminium arm
Diameters:
1) 75 x 2 x 3000 mm
2) 70 x 2 x 2000 mm
3) 70 x 2 x 4000 mm
Weights:
2,5 mt = 3,8 Kg
4 mt = 6,2 Kg
6 mt = 8,7 Kg
10
Min 5,40 mt (transit width 5,0 mt) - Max 6,40 mt (transit width 6,0 mt)
6 mt Round telescopic arm
4 mt Round telescopic arm
pzx 2 /mt
==
Arm dimensions
Arm stikers and cap
Fix the two parts of the arm
whit a 4,8x16 self-threading
screws
x2
FIG.9

11
PART. C
PART. A
Adjusting limit switches and rubber stoppers
Adjusting the spring tension:
90
30
Adjust the rubber stoppers
and the switches so that the
arm is horizontal when in
closed position and vertical
when in open position.
After having installed the arm on the barrier is mandatory to adjust the spring tension :
1.Unlock the reducer
2.Set the arm in the opening position
3.Lock the reducer
4.Turning the tensioning nut, tension the spring until obtaining the best setting
Verification of the best setting :
1.Unlock the reducer
2.Carefully bring the arm in the closed position
3.Release the arm
4.If the spring is tensioned correctly the arm should open and stop at about 30° degree
The spring should be tensioned
during the entire travel of the arm
without any play
The spring tensioning should be
checked after 15 days from the
installation
FIG.10
FIG.11

12
WARNINGS:
BAME s.r.l. , as manufacturer, can not be held responsible for damages
due to wrong or missing connections or due to an improper setting.
The safety devices should be always installed and kept in full working order.
Once terminated the system setting, you should place back the container
on its position, fastening tight its screws.
BAME s.r.l. , as manufacturer, can not be held responsible for damages
due to improper use of the door/gate.
It is forbidden to replace any electric, electronic or mechanic part with not
original spare parts.
BAME s.r.l. , has the right to modify or change the electronic boards and
manuals, without prior notice.
Always regulate accurately the torque of the motors. An incorrect setting of
the torque may cause damage to people, animals or objects.
WARRANTY:
46020, Italy
San Giacomo Segnate (MN)
BAME s.r.l.
Grottazzolina (FM)
Leonardo da Vinci, 23
E. Berlinguer, 6
63844, Italy
Tel. +39 0376 616638
Tel. +39 0734 633533
Fax +39 0376 629456
Fax +39 0734 636895
www.bame.it
www.delma.it
e-mail:info@bame.it
e-mail: [email protected]
Devices and accessories are guaranteed for a period of 24 months after
production, whose date is printed on each item. The company will replace
or repair its devices, provided that they are returned to our factory with the
warranty label in good conditions. In case of replacement of the returned
items, these will remain property of the company. The warranty does not i
nclude damages due to any incorrect use, such as: non fulfilment of the
instruction detailed for each device, maintenance and servicing carried out
without the previous written consent of our company.
Moreover, warranty does not cover any damage due to wrong tension
supply and any other reason for which the manufacturer cannot be made
responsible. Any device returned must be delivered to our company with
carriage paid and will be sent back with freight collect.
Warranty validity ceases if customer’s payments are not fulfilled.
Each device manufactured by our company meets the european safety
standards. Our company declines all responsibility for the non-observance
of the safety rules by the installers.
In order to reduce the time spent for servicing the returned items, all faulty
materials which have been sent back to us must be accompanied by the
installer description of the item fault.
Table of contents
Other Bame Control System manuals
Popular Control System manuals by other brands

WAREMA
WAREMA Quatronic dialog operating instructions

Zipato
Zipato ZIPATILE quick start guide

Lutron Electronics
Lutron Electronics RadioRA 2 Commisioning Checklist

Nidec
Nidec Control Techniques HVAC Drive H300 HMI... Installation and commissioning guide

Madel
Madel FDS-MINI manual

Cylon
Cylon NEXUS Series Hardware installation guide

ShopBot
ShopBot PRSalpha Assembly manual

Siemens
Siemens SINUMERIK 840D sl Commissioning manual

heat-timer
heat-timer 928051-50-VM Installation and operation manual

WAREMA
WAREMA Wisotronic operating instructions

Leb Electronics
Leb Electronics CTR640 instructions

ZF Marine
ZF Marine ClearCommand 9000 Series Installation, operation and troubleshooting manual