Basic American Liberty User manual

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
ETL/UL/CSA APPROVED
UL 60601-1
IEC 60601-2-38
CSA 22.2 601.1
INSTRUCTIONS FOR USE
SERVICE MANUAL
To avoid personal injury or damage to bed,
please read all sections pertaining to
your bed model before use.

This service manual covers the following Liberty Models:
LIberty
76” & 80” Full Electric with Standard Caster System & Grid Decks = LBT7174;
76” & 80” Full Electric with Locking Caster System & Grid Decks = LBTL7174.
IMPORTANT NOTICE
GF Health Products, Inc. is not responsible for typographical errors.
All illustrations, specifications, packaging, and warranties contained in this Service Manual
are based on the latest product information available at the time of printing.
The most current product information can be found online at www.grahamfield.com.
Please check all parts for shipping damage and test before using.
In case of damage, DO NOT USE.
Basic American Medical Products
336 Trowbridge Drive
Fond du Lac, WI 54937
For Liberty Bed Service Parts
please contact our Customer Service Department
at 1-678-291-3207
GF Health Products, Inc.
2935A Northwest Parkway
Atlanta, GA 30360
www.grahamfield.com
To order a Liberty Bed
please contact a Graham Field Sales Representative
at 1-678-291-3346

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
3
TABLE OF CONTENTS
Safety & Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warning Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Recommended Maintenance . . . . . . . . . . . . . . . . . . . . . .6
Entrapment/Compliance . . . . . . . . . . . . . . . . . . . . . . . . . 7
Unpacking Your Bed . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Liberty ID/Serial Labels . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Liberty Headboard and Footboard Installation . . . . . . . .10
Standard Mattress Retainer Installation . . . . . . . . . . . . .11
Standard Wallsaver Installation . . . . . . . . . . . . . . . . . . .12
Pendant/Hand Controller Operation . . . . . . . . . . . . . . . .13
Liberty Bed Positions and Deck Elevations . . . . . . . . . .14
One-Step Locking Mechanism Operation . . . . . . . . . . . .15
Mechanical & Electronic Specifications . . . . . . . . . . . . . 16
IILCON Electrical Components . . . . . . . . . . . . . . . . . . . .17
Service Part Record . . . . . . . . . . . . . . . . . . . . . . . .18 & 19
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Bed Diagram with ILCON Electronics . . . . . . . . . . . . . . .20
Fixed Assist Bar Installation - Head . . . . . . . . . . . . . . . 21
Foot-end Mounting Bracket and Cross Tubes . . . . . . . .22
Fixed Assist Bar Installation - Foot . . . . . . . . . . . . . . . . 23
Pivoting Assist Bar Installation - Head Only . . . . . . . . . 24
Metal Half Rail Installation - Head . . . . . . . . . . . . . . . . .25
Metal Half Rail Installation - Foot . . . . . . . . . . . . . . . . . .26
Trapeze Support Installation . . . . . . . . . . . . . . . . . . . . . .27
Foot-end Extension Pan (4.00”) . . . . . . . . . . . . . . . . . . .28
One Step Locking Mechanism . . . . . . . . . . . . . . . . . . . .29
SECTION A - Electronic Troubleshooting . . . . . . . . . 30
SECTION B - Framing Service Parts . . . . . . . . . . . . 33
LIBERTY SERIES

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
4
This product is a variable height, adjustable mattress
platform, which will provide comfort and convenience
for residents/patients and caregivers in long term
care settings.
The MAXIMUM SAFE WORKING LOAD for the
Liberty Bed with weight evenly distributed, including
bedding, resident/patient, support surface, and all
accessories, is 450 lbs.
NEVER operate the bed if a Power Cord or Plug is
damaged or not working properly. Contact qualified
Service Personnel for examination and repair. Always
unplug the Power Cord when performing any mainte-
nance on the bed.
DO NOT open assemblies such as the Actuators, Hand
Control, or Control Box. If unauthorized personnel
perform work on these components, the manufacturer’s
warranty becomes void.
DO NOT use unauthorized parts, accessories, or
adaptors other than those specified/authorized by
GF Health Products, Inc.
When operating the High/Low, Knee, or Back Functions
of the bed, ALWAYS ensure that the confined individual
is positioned properly within the confines of the bed.
DO NOT let any extremities protrude over the side or
between the bed rails when performing these functions.
DO NOT lower the bed when objects are beneath it.
Failure to inspect under the bed can result in damage
to property or personal injury.
The bed’s Pendant Cord MUST BE ROUTED AND
SECURED PROPERLY to ensure it does not become
entangled and eventually severed during use. Also
make sure all electrical cords DO NOT get tangled
around the bed, side rails, or legs during transport or
normal operation of the bed.
When using nasal-type or masked-type administering
equipment, all oxygen or air tubing MUST BE ROUTED
AND SECURED PROPERLY to ensure that the tubing
does not become entangled and eventually severed
during the normal operation of the bed.
Notice for California Customers -
California Proposition 65 WARNING: This prod-
uct contains a chemical known to the State of Califor-
nia to cause cancer and reproductive or developmental
harm.
The bed should ALWAYS be left in its lowest position
when unattended to reduce the risk of injury while getting
in or out of the bed.
Keep all moving parts free of obstructions (i.e. blankets/
sheets, heating blankets/pads, wiring, etc.).
DO NOT use the assist devices as push handles for moving
the bed. Assist devices can be deformed or broken if
excessive side pressure is exerted. Assist devices are not
meant for patients considered as high risks for entrapment
(i.e. patients with pre-existing conditions such as
confusion, restlessness, lack of muscle control, altered
mental status, either organic or medicinal, or a combi-
nation thereof). Additional safety measures should be
considered for such high-risk patients.
NEVER permit more than one (1) person on/in the bed
at any time.
Body weight should be evenly distributed over the
sleeping surface of the bed. DO NOT allow the patient
to lay, sit, or lean in such a way that their entire body
weight is placed only on the raised head or foot sections
of the bed. This especially applies when repositioning
or transferring a patient in or out of the bed. Increased
risk may occur when the patient’s size and/or weight are
inappropriate for the bed’s dimensions or weight capacity.
The bed is intended for use, storage, and transport within
a temperature range of -40˚C to +60˚C. It has a water-
resistance rating of IPX4 and IS NOT to be power-
washed or submersed.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Operating Conditions
Operation of the bed is based on the following conditions:
Ambient Temperature of +10˚C to +40˚C; Relative Humidity
of 30% to 75% (Non-condensing); Atmospheric Pressure of
700hPa to 1060hPa; and a Splash Protection of IEC 60529.
Storage
Storage of the bed is based on the following conditions:
Ambient Temperature of -10˚C to 70˚C; Relative Humidity
of 10% to 100%; and an Atmospheric Pressure of 500hPa
to 1060hPa.
Radio Frequency Interference (RFI)
RFI influences most electronic equipment. Caution should be
exercised with regard to the use of portable communications
equipment in the area around such equipment. If RFI causes
erratic behavior, shut the bed off immediately. Leave it off
while the transmission is in progress.
IMPORTANT SAFETY AND WARNING INFORMATION
LIBERTY SERIES

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
5
WARNING!
DO NOT LOWER BED WHEN OBJECTS ARE
BENEATH BED. FAILURE TO INSPECT UNDER
BED CAN RESULT IN DAMAGE TO PROPERTY
OR PERSONAL INJURY.
ATTENTION:
S’assurer de ne pas faire descendre le lit
lorsque des objets se trouvent sous le lit. Ne
pas inspecter le dessous du lit pourrait entrainer
des dommages materiels et des risques de
blessures.
WARNING!
DO NOT LOWER BED WHEN
OBJECTS ARE BENEATH BED.
FAILURE TO INSPECT UNDER
BED CAN RESULT IN DAMAGE
TO PROPERTY OR PERSONAL
INJURY.
CAUTION
THIS BED IS SUITABLE FOR USE ONLY WITH
OXYGEN ADMINISTERING EQUIPMENT OF
THE NASAL OR MASK TYPE OR A TENT
COVERING ONLY THE UPPER HALF (HEAD
END) OF THE BED. OXYGEN TENT CANOPIES
SHOULD NOT EXTEND BELOW BED SPRING
LEVEL. LOCK HAND CONTROL AT FOOT OF
BED WHEN USING OXYGEN ADMINISTERING
EQUIPMENT.
ATTENTION:
CE LIT PEUT ETRE UTILISE UNIQUEMENT
AVEC UN EQUIPMENT DESTINE A
L’ADMINISTRATION D’OXYGENE DE TYPE
NASAL OU MASQUE OU AVEC UNE TENTE
RECOUVRANT SEULEMENT LA MOTTIE
AVENT (TETE) DU LIT. LES COTES DE LAS
TENTE OXYGENE NE DOIVENT PAS SE
PROLONGER PLUS DAS QUE LA SOMMIER
DU LIT.
The following warning labels have been placed on your bed to help protect you and your bed from
damage. Please do not remove any labels from your bed.
TYPICAL SAFETY/WARNING BED LABELS
LIBERTY SERIES
Protected
Grounded
Device
Safe
Working
Load
Consult
Accompanying
Documents
Type B
Equipment &
Applied Parts
!
!
LABEL SYMBOL DEFINITIONS
Double
Insulated

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 20143
6
LIBERTY SERIES
RECOMMENDED MAINTENANCE SCHEDULE
RECOMMENDED
INSPECTION PERIODS
ITEM Inspect
on Receipt
Every
3 Months
Every
6 Months
Maintenance Inspection of All Components at Receipt of Shipment
Make sure all parts/components are included (Please see “Unpacking Your Bed”). X
Check all bed components for obvious damage. X
Inspect the power supply cord for any cuts and/or damage. X
Check to see all actuator/motor cords are routed and connected properly to the control box. X
Mechanical Inspection of Assemblies
Inspect all welds on the sleeping surface, frame, and base assemblies for stress fractures. X
Inspect all fasteners for wear and looseness. X
IMPORTANT: Lubricate all pivot points, actuator/motor clevis pins, and control arm
clevis pins as needed. White Lithium Grease is recommended. X
Mechanical Inspection of Casters & Pedal Locking Mechanism
Check the pedal locking mechanism to make sure it engages and disengages properly. X
Check the bottom foot pads on the foot end casters, making sure they are clean of debris
and undamaged. Replace if needed. X
Check all casters to ensure that they roll properly and are unobstructed. X
Electrical Inspection of Control Box, Pendant, and Staff Control
Check the external power cord that plugs into the control
box for any chafing, cuts, or wear. Replace if damaged. X
Make sure all attaching hardware is securely tightened. X
Check all electrical connections for any wear or fractures. X
Check your external backup battery (if you have one). Replace if needed. X
Check the pendant cord for any chafing, cuts, or wear. X
Check all pendant functions - check to make sure each
button and associated function work properly (i.e. head
section rises when the Head Up button is activated).
X
Electrical Inspection of Actuators/Motors
Check the actuator/motor cords for any chafing, cuts, or wear. X
Check the range of movement on all motors to ensure
they do not bind in the Full Up or Full Down positions. X
Regular maintenance of your Long Term Bed is necessary to ensure continuing proper and safe operation.
Please read and observe the following recommended maintenance schedule.

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
7
On March 10, 2006, the FDA (U.S. Food and Drug Adminis-
tration) released long-awaited guidelines for reducing the risk
of bed entrapment: “Hospital Bed System Dimensional and
Assessment Guidance to Reduce Entrapment”. The new Guidance
identifies potential entrapment areas and those body parts most
at risk for entrapment; provides design criteria for manufacturers
of new hospital/convalescent beds; recommends particular test
methods to assess the conformance of existing hospital/conva-
lescent bed systems; and answers frequently-asked questions
about entrapment issues.
The new Guidance was a result of a long-standing collaboration
between the FDA and the Hospital Bed Safety Workgroup
(HBSW), formed in 1999. GF Health Products, Inc’s Long-
Term Care Bed division: Basic American Medical Products, is
an HBSW charter member. As a result of our commitment to
product safety, all our current long-term care beds have been
strictly tested and conform to the new FDA Guidance.
The guidelines set forth by the FDA Guidance layout specific
dimensional limitations on potentially injury-threatening gaps
and spaces that can occur between bed system components,
such as rails, when not properly installed. GF Health Products,
Inc. and Basic American Medical Products have conformed
to these guidelines from a manufacturing aspect. However,
entrapment issues can often arise when a healthcare provider/
facility has not correctly assembled the components on a bed.
It is essential that the provider/facility fully understand their
responsibility in complying to the guidelines set forth by the
FDA in order to avoid injury. To that end, we have provided
the FDA’s web address at right as a resource for understanding
and following these guidelines for the safety of patients/residents.
It is also essential to have the correct bed components/acces-
sories that correspond with the needs of your patient/resident
and the particular bed you have purchased. Matching the correct
bed component that correlates with the regulatory guidelines can
be a daunting task. Our sales team at GF Health Products, Inc.
and our friendly Customer Service Representatives at Basic
American Medical Products can help you sift through the wide
array of compliance and bed options. We will help you determine
which bed/bed part is best for your patient’s/resident’s particular
needs and help you with your compliance issues.
The Liberty bed and accessories listed in this manual
are in full compliance with FDA guidelines for
reducing the risk of bed entrapment: “Hospital
Bed System Dimensional and Assessment Guidance
to Reduce Entrapment”.
Details can be found at www.fda.gov.
ENTRAPMENT & COMPLIANCE INFORMATION
LIBERTY SERIES

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
8
UNPACKING YOUR BED
•Make sure all parts/components are included.
•Check all bed components for obvious damage.
•Inspect the Power Supply Cord for any cuts and/
or damage.
•Check to see all actuator/motor cables are routed
and connected properly to the control box.
DISCARD
1. Cardboard Block
2. Notched Leg Foam
3. Large Blocks
4. Large Cable Tie - CUT
KEEP
5. Pendant Holster, Pendant
& Power Cord - Coiled for
shipping and cable tied to
Grid Wire on Head Deck.
6. One Mattress Retainer
7. One Wireform Wallsaver
8. Panel Mounting Brackets
& Hardware for attaching
Headboard & Footboard
9. Service Manual/Documents
ALSO
DISCARD TOP
AND BOTTOM
CARTONS
LIBERTY SERIES

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
9
GF HEALTH
PRODUCTS, INC.
DUTY CYCLE - 2 min Continuous/18 min
MODE OF OPERATION - Intermittent
450 lbs
SAFE WORKING LOAD
=IPX4
MODEL NO
701-0000-000000
SERIAL NO
000000000000
MFG. DATE
09/01/11
VOLT HZ AMP TYPE
120 50/60 2 AC
!
LBT7174
MODEL NO. 701-0000-000000 MFG DATE 09/01/11
SERIAL LBT7
LBT7174
LIBERTY 701 SERIES
PATENT PENDING
LIBERTY 7174
000000000000
Bed labels are an important part of
identifying your bed’s make and model
when ordering replacement parts. The
Serial Number is essential if you are
claiming parts or service under warranty.
These helpful labels can be located on
the main frame rails, immediately below
the sleep decks on either side of the bed.
Please have this IMPORTANT infor-
mation ready when calling our customer
service or technical support staff at
1-678-291-3207; it will allow us to better
assist you and quickly answer your
questions and concerns.
TYPICAL LIBERTY BED IDENTIFICATION LABELS
with Ilcon Electronics - LBT7174 or LBTL7174
(Models Manufactured After Sept. 2011- Serial Numbers =/> to 12020004096)
ATLANTA, GA 30360
LIBERTY SERIES
ETL
Logo

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
10
HEAD- AND FOOTBOARD (PANEL) ASSEMBLY
LIBERTY SERIES
HEADBOARD
FOOTBOARD
1. Assemble four inserts (#4) into the outside of both the headboard and footboard if not already
pre-assembled.
2. Assemble a right-hand and a left-hand Board Mounting Bracket (#2 & #3) to the insides of both
the headboard and footboard using four 1/4-20 x 20mm Hex Drive JCB-B Bolts (#5) for each
board. The bolts will go through the four pre-drilled holes on each board into the inserts.
3. Slide the headboard and footboard (with mounting brackets) into the main frame rails.
a) For a 76” bed, align the holes in the brackets with the second holes from the end in the sides
of the main frame rails (See Detail A).
b) For an 80” bed, align the holes in the brackets with the first holes from the end in the sides of
the main frame rails (See Detail A).
4. From the outside of the main frame rails, insert a 5/16 x 1.50” Clevis Pin (#6) through the holes
in the frame rails and brackets on both sides of the bed.
5. Secure the clevis pins by inserting a 1-9/16 Hair Pin Clip
(#7) through each of the holes in the ends of the four pins.
HEADBOARD-
MOUNTING
FOR 80” BED
DETAIL B
MOUNTING
FOR 76” BED
NOTE: To order a new Panel Mounting Kit, please use part # 999-0822-000. Kit includes a right-hand and left-hand
Mounting Bracket, 8 Hex Drive Bolts, 4 Clevis Pins, 4 Hair Pin Clips, and 1 Hex Allen Wrench. Both Panels (Head-
board and Footboard) are sold separately.
FOOTBOARD-
MOUNTING
FOR 80” BED

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
11
!Be sure to use a mattress that is properly sized to fit
the sleep deck, which will remain centered on the
deck relative to State and Federal Guidelines. Use
of an improperly fitted mattress could result in injury
or death.
!Use a properly sized mattress in order to minimize
the gap between the side of the mattress and assist
devices. This gap must be small enough to prevent
resident/patient from getting his/her head or neck
caught in this location.
STANDARD FULL-WIDTH MATTRESS RETAINER INSTALLATION
LIBERTY SERIES
The Liberty Bed’s mattress retainer was designed to span the width of the sleeping surface.
One retainer is shipped with your bed and is typically placed at the foot end, although it will
fit on either end. It is easily attached to the decks by inserting it into the pre-drilled holes for
76” or 80” positions (see insert below).
To order an additional mattress retainer,
please use part # 999-0822-001SP.

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
12
QUICK-INSTALL, VERSATILE HEAD-END WALLSAVER
LIBERTY SERIES
FLAT TAB LOCKS INTO
THE CARRIAGE RAIL BY
TURNING IT IN SIDE HOLE
UNTIL THE WALLSAVER
RESTS ON CROSSBRACE
FLAT TAB IS INSERTED
SO THAT IT IS PARALLEL
WITH THE SLOT IN THE
CASTER CARRIAGE RAIL
The Liberty Bed is shipped with a durable wireform wallsaver for the head-end of the bed. No hardware is necessary
for attaching this multi-positional standard accessory.
Simply bend-in the tabbed ends into the slots in the carriage rails and lock down into place. There is even a position if
you choose to install an optional trapeze support at the head end of the bed. (See page 27 for Trapeze Support
installation in the Accessories section of this manual.)
FINAL WALLSAVER RESTING POSITIONWALLSAVER ATTACHING POSITION
Wallsaver hole for 80” Bed with Trapeze
Wallsaver hole for 76” Bed with Trapeze
Wallsaver hole for 80” Bed without Trapeze
Wallsaver hole for 76” Bed without Trapeze

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
13
NOTE:
The easiest method for deactivating the Pendant function is to simply unplug the power cord from
the wall socket or other power supply when the patient is left alone in the bed. When you need to
use the Pendant function to raise or lower the bed or decks, replug the power cord into the power
outlet.
NON-BACKLIT PENDANT
Model #HB00
Part # 999-0808-305SP
NON-BACKLIT PENDANT
1 HEAD DECK ANGLE UP BUTTON
2 HEAD DECK ANGLE DOWN BUTTON
3 HI/LO UP BUTTON (RAISE ENTIRE BED)
4 HI/LO DOWN BUTTON (LOWER ENTIRE BED)
5 KNEE & FOOT DECK ANGLE UP BUTTON
6 KNEE & FOOT DECK ANGLE DOWN BUTTON
OPERATION:
1. To angle the Head Deck upward, PRESS 1
2. To angle the Head Deck downward, PRESS 2
3. To raise the Bed Up horizontally, PRESS 3
4. To lower the Bed Down horizontally, PRESS 4
5. To angle the Knee/Foot Decks upward, PRESS 5
6. To angle the Knee/Foot Decks downward, PRESS 6
STANDARD PENDANT/HAND CONTROLLER OPERATION
LIBERTY SERIES
1
3
5
2
4
6
Male End Connector
of Pendant Cable
Pendant Holster
999-0791-000SP
Each of the Liberty Beds are equipped with a pendant-type hand control - standard.
Every control function (head/back, knee, and foot) has two easily recognizable
switches for up and down movement. The pendant can be easily dis-connected to
deactivate the patient control functions.
To operate, simply push the appropriate button to activate the desired function (see
diagram at right).

LIBERTY BED HI/LO & DECK POSITIONS
GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
14
LIBERTY SERIES
The Liberty bed has a variety of positions that serve to help the patient be more comfortable
and gives the practitioner/caregiver easy access during procedures and transfers.
The correct placement of the bed is essential for the patient’s safety.
The bed should always be set to its lowest position when the resident/patient
is left unattended. The head/back and foot/knee functions allow the
resident/patient to comfortably raise their head or legs. In the event of a power
outage, it is preferred that the knee and head/back sections be lowered
using an emergency battery pack.
HEAD
END
FOOT
END
QUICK REFERENCE
Bed Height - floor to sleep deck top
MAXIMUM (High Position) = 24.50”
MINIMUM (Low Position) = 9.95”
Head Deck to Sleep Surface
MAXIMUM (Head Angle) = 70°
Knee Deck to Sleep Surface
MAXIMUM (Knee Angle) = 30°
Knee Deck to Foot Deck
MAXIMUM (Knee/Foot Angle) = 45°

LIBERTY BED ONE-STEP LOCKING MECHANISM
OPERATION INSTRUCTIONS
GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
15
LIBERTY SERIES
Locked Position
on Your Liberty Bed
To lock the foot end of the Liberty bed,
step on the red pedal until the lock
engages. The green release lever will
show through the slot in the top of the
locking mechanism. To fully lock the
bed, make sure the caster keepers at
the head of the bed are both in their
down positions.
Unlocked Position
on Your Liberty Bed
To unlock the foot end of the Liberty
bed, step on the green release pedal
until the lock disengages. The green
release lever will disappear through
the slot in the top of the pedal locking
mechanism and the red pedal will raise.
To fully unlock the bed, make sure the
caster keepers at the head of the bed
are both in their up positions.

LIBERTY ILCON ELECTRONICS
After 09/01/2011 Mfg Date
GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
16
•Power/Frequency . . . . . . . . . . . . 120 Volt - 50/60 Hz
•Output Rating . . . . . . . . . . . . . . . . . . . . . . . 24V IPX4
•Overall Movement Draw . . . . . . . . . . . . . 2.00 Amps
•Classification . . . . . . . . . . . . . . . . . . . Class I, Type B
•Electrical Cord . . . . . . . . . . . . #18 AWG 3 Conductor
Type SJT
•Mode of Operation . . . . . . . . . .10% Max. Duty Cycle
2 minutes on/18 minutes off
LIBERTY BED MECHANICS
(All Models)
•Overall Bed Length (with brds & wallsaver) . . 83”/86”
•Overall Bed Width (with boards) . . . . . . . . . . . 36.00”
•High Height* . . . . . . . . . . . . . . . . . . . . . . . . . . 24.50”
•Low Height* . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.95”
•Maximum Head/Back Deck Angle . . . . . . . . . . . . 70°
•Maximum Knee/Foot Deck Angle . . . . . . . . . . . . 30°
•Maximum Safe Working Load . . . . . . . . . . . 450 lbs.
WITH WEIGHT EVENLY DISTRIBUTED
- includes bedding, resident, support surface,
and all accessories.
•Mass of bed (without assist devices or boards) = 182 lbs.
* Bed height calculated from floor surface to top of
sleep deck.
NOTE: All dimensions are in a range of +/- .25 inches
(All Beds with Serial Numbers equal to or after SN12020004096)
LIBERTY SERIES

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
17
LIBERTY ELECTRICAL ILCON COMPONENTS (After 09/01/2011)
LIBERTY SERIES
VENDOR MODEL HB00
PENDANT:
Part # 999-0808-305SP
Quantity = 1
Bed also includes
Pendant Holster
Part # 999-0791-000SP
Quantity = 1
Adaptor Cable
for connecting
Pendant Cable
to Control Box
Part # 999-0848-200SP
Quantity = 1
NOTE:
MOTOR CABLES AND
POWER CORD ARE
NOT DETACHABLE
(SEPARATE ITEMS).
CABLES ARE HARD
WIRED DIRECTLY
INTO MOTORS AND
CONTROL BOX.
Control/Junction Box
Part # 999-0848-300SP
Quantity = 1
Power Cable is
not detachable
(hard-wired into
the side of the
Control Box)
Head Motor/Actuator
Part # 999-0844-052SP
Quantity = 1
Hi/Lo Motor/Actuator
Part # 999-0848-051SP
Quantity = 1
Knee/Foot Motor/Actuator
Part # 999-0844-053SP
Quantity = 1
!DO NOT use unauthorized parts, accessories, or adaptors other than those specified/authorized by GF Health Products, Inc.
DO NOT open assemblies such as the Actuators, Hand Control, or Control Box. If unauthorized personnel perform work on
these components, the manufacturer’s warranty becomes void. NEVER operate the bed if a Power Cord or Plug is damaged or
not working properly. Contact qualified Service Personnel for examination and repair. Always unplug the Power Cord when
performing any maintenance on the bed.

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
18
SERVICE/REPLACEMENT PART RECORD - WITH ILCON ELECTRONICS
DECKING
Part Number Description QTY Order Date Price
999-0844-920SP Head/Back Deck & Hardware Pack 1 Deck
999-0844-930SP OR - Foot Deck & Hardware Pack 1 Deck
999-0844-940SP OR - Knee Deck & Hardware Pack 1 Deck
Deck Hardware Pack - INCLUDES . . . 1 Pkg
4 Clevis Pins
5 5/16” Retaining Rings (Deck Brackets)
212mm Retaining Ring (Cntrl Arms to Decks)
1 Installation Instruction Sheet
MOTORS (ACTUATORS)
Part Number Description QTY Order Date Price
999-0848-051SP Hi/Lo Motor (Cable hard-wired) & Hardware Pack 1 Motor
999-0844-052SP OR - Head Motor (Cable hard-wired) & Hardware Pack 1 Motor
999-0844-053SP OR - Foot Motor (Cable hard-wired) & Hardware Pack 1 Motor
Motor Hardware Pack - INCLUDES . . . 1 Pkg
2 12mm Retaining Rings
2 Hair Pin Clips
2 Snap Rings
8 Standard Cable Ties
1 Installation Instruction Sheet
CONTROL BOX & POWER CABLES
Part Number Description QTY Order Date Price
999-0848-300SP Linak Control Box and Clip 1 Box
No Detachable Power Cord Available (Cord hard-wired to CB)
PENDANT/HAND CONTROLLER
Part Number Description QTY Order Date Price
999-0808-305SP Pendant (Std. Model) 1 Pendant
999-0848-200SP Pendant Adaptor Cable 1 Cable
999-0791-000SP Pendant Holster (Std. for all pendants) 1 Holster
LIBERTY SERIES

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
19
SERVICE/REPLACEMENT PART RECORD-WITH ILCON ELECTRONICS
MISCELLANEOUS SERVICE BED PARTS
Part Number Description QTY Order Date Price
999-0822-012 Spanner Plates 1 Plate
999-0822-031 Pivot Channels 1 Unit
999-0822-036 Leveler Rods 1 Rod
100-8050-008 1/2” E-Style Retaining Rings (for Leveler Rods) 1 Ring
999-0822-001SP Mattress Retainer 1 Unit
999-0822-180SP Wireform Wallsaver 1 Unit
999-0822-083 18GA Ground Wire 1 Wire
100-5710-019 #10-24 x .375” HWHTC Ground Screws TYP23 1 Screw
100-1100-018 Standard Cable Ties 1 Tie
100-1100-060 Wing-Tip Cable Ties 1 Tie
CASTER CARRIAGE
Part Number Description QTY Order Date Price
999-0822-905G Caster Carriage Weldment 1 Unit
100-6330-062SP 3” Twin Locking Caster with 7/16-14 Stems (LBT7174) 1 Caster
100-6330-061SP 3” Twin Non-Locking Caster with 7/16-14 Stems (LBTL7174) 1 Caster
999-0832-980SP One-Step Locking Mechanism (LBTL7174) 1 Unit
100-6744-001 7/16-14 Nylon Lock Nuts (secure caster stems to frame) 1 Nut
CAPS & PLUGS
Part Number Description QTY Order Date Price
NOTE: CAPS & PLUGS CAN ONLY BE PURCHASED IN SETS OF 12
100-4700-015PK 1.00” x 1.00” Square Caps Pack 12/pkg
100-4700-017PK 1.00” x 2.00” Rectangular Caps Pack 12/pkg
999-0822-041PK Black Tube Pivot Caps 12/pkg
FOR GENERAL CAP DIAGRAMS PLEASE SEE PAGES 44 & 45
LIBERTY SERIES
WARRANTY
- 10 Years on Frame
- 2 Years on Motors and Control Box
- 1 Year on Other Electronics
The warranties contained herein contain all the representation and warranties with respect to the subject matter
of this document, and supersede all prior negotiations, agreements and understanding with respect thereto.
The recipient of this document hereby acknowledges and represents that it has not relied on any representation,
assertion, guarantee, warranty, collateral contract or other assurance, except those set out in this document.

GF Health Products, Inc. - www.grahamfield.com Liberty Service Manual 999-0822-190F AUG. 2014
20
WHEN ORDERING REPLACEMENT PARTS WITH CUSTOMER SERVICE,
PLEASE HAVE YOUR BED’S SERIAL NUMBER AVAILABLE
TO CONFIRM WHETHER THE PART IS COVERED UNDER WARRANTY.
(SEE PAGE 9 FOR LOCATION OF SERIAL NUMBER ID LABEL.)
1. TO ORDER A REPLACEMENT
HI/LO MOTOR USE SERVICE PACK
999-0848-051SP (Includes motor,
mounting hardware & installation
instruction sheet.)
2. TO ORDER A REPLACEMENT
HEAD MOTOR USE SERVICE PACK
999-0844-052SP (Includes motor,
mounting hardware & installation
instruction sheet.)
3. TO ORDER A REPLACEMENT
FOOT MOTOR USE SERVICE PACK
999-0844-053SP (Includes motor,
mounting hardware & installation
instruction sheet.)
4. TO ORDER A REPLACEMENT
CONTROL BOX PLEASE USE
999-0848-300SP (Includes Control
Box and mounting clip.)
5. TO ORDER A REPLACEMENT
MATTRESS RETAINER PLEASE
USE 999-0822-001SP
6. FOR NEW WALLSAVER PLEASE
USE 999-0822-180SP
SERVICE/REPLACEMENT PART DIAGRAM - STANDARD BED
WITH ILCON ELECTRONICS
WIREFORM
WALLSAVER
“STANDARD” CASTER CARRIAGE
WITH FOUR LOCKING CASTERS
FOOT/KNEE
MOTOR
CONTROL BOX -
ATTACHED TO
HI/LO MOTOR
HEAD BOARD
FOOTBOARD
MATTRESS
RETAINER
SPECIAL
BOARD/PANEL
MOUNTING
BRACKETS
POWER CABLE
SECURED TO FRAME
WITH CABLE TIES
PENDANT CABLE PLUGGED
DIRECTLY INTO CONTROL
BOX AND CABLE TIED TO
EITHER SIDE OF SEAT PAN.
HEAD-END
HI/LO MOTOR
HEAD
END
FOOT
END
LIBERTY SERIES
FOR ALL OTHER SERVICE PARTS PLEASE REFER TO PAGES 25 - 26.
This manual suits for next models
2
Other Basic American Medical Equipment manuals

Basic American
Basic American ZENITH Series User manual

Basic American
Basic American Slide-W-I-D-E Zenith 9000APS User manual

Basic American
Basic American Zenith 7000 User manual

Basic American
Basic American Slide-W-I-D-E ZZ98674 User manual

Basic American
Basic American ZENITH Series User manual

Basic American
Basic American Slide-W-I-D-E Zenith 9000APS User manual

Basic American
Basic American ZENITH Series User manual