INSTALLATION
WALL MOUNT - SINGLE FACE:
1. Extend unswitched 24 hour AC supply of rated voltage to junction box or appropriate wiring (supplied by others). Leave at least eight
(8) inches of slack wire. The circuit should not be energized at this time.
2. If a chevron is desired remove side panel with screw driver. Gently remove the red fibre and remove the chevron adhesive as desired.
Reinsert the red fibre and secure the side of the exit back on with the screwdriver.
3. A wire pass-thru hole on the exit back plate is design to route the wires through the back of the sign (Figure 1)
4. Mount the exit securely in place. Screw directly to the junction box if possible. If not a spider plate (provided by other) may be used to
connect the exit to the junction box (Figure 2)
5. Connect AC supply per diagram provided (Figure 3)
6. Ensure all wires are secured into place for a clean finished appearance (Figure 4)
7. Turn on the AC voltage supply
CEILING/END MOUNT - SINGLE OR DOUBLE FACE:
1. Extend unswitched 24 hour AC supply of rated voltage to junction box or appropriate wiring (supplied by others). Leave at least eight
(8) inches of slack wire. The circuit should not be energized at this time.
2. If a chevron is desired remove side panel with screw driver. Gently remove the red fibre and remove the chevron adhesive as desired.
Reinsert the red fibre and secure the side of the exit back on with the screwdriver.
3. Ceiling and end mount units are provided with a factory installed canopy which is not field adjustable.
4. Mount the exit securely in place. Screw directly to the junction box if possible. If not a universal spider plate may be used to connect the
exit to the junction box for exit sign placement adjustment or connection to a variety of electrical boxes.
5. Exit signs that are specified double face will already have the second/rear faceplate installed.
6. Connect AC Supply per diagram provided (Figure 3)
7. Ensure all wires are secured into place for a clean finished appearance (Figure 4)
8. Turn on the AC voltage supply
SELF-POWERED:
1. For models MCE-SP, plug the battery into the circuit board per (Figure 3) self-powered sign.
INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS
2. Disconnect power before performing work on electrical equipment.
3. Do not use outdoors.
4. Use caution when servicing batteries.
5. Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to
tampering.
6. The use of accessory equipment not recommended by BeLuce Canada Inc., may cause an unsafe condition, and
will void the unit’s warranty.
7. Do not use this equipment for other than its intended purpose.
8. Servicing of this equipment should be performed by qualified service personnel.
9. SAVE THESE INSTRUCTIONS!
MICRA RM (MC-RM)
926000411
BeLuce Canada Inc., 3900 14th Avenue, Unit 1, Markham, ON L3R 4R3 P: (905) 948-9500 F: (905) 948-8673
926000411
MAINTENANCE
1. The lamps listed herein when used according to the instructions with this unit are in accordance with the requirements of CSA Standard
C22.2, No. 141 – Unit Equipment for Emergency Lighting.
2. Clean lenses on a regular basis.
NOTE: The servicing of any parts should be performed by qualified service personnel only. The use of replacement parts not furnished by
BeLuce Canada Inc., may cause equipment failure and will void the warranty.
SAVE THESE INSTRUCTIONS
Universal
Spiderplate
Electrical
Junction Box
(supplied by
others)
Chassis GND LED Board
AC ONLY SIGN
Chassis GND
GREEN Ground
BLACK 120VAC
RED 347VAC or ORANGE 200-277VAC
WHITE Neutral
LED Board
AC & UNIVERSAL DC SIGN
YELLOW Positive 6 to 24VDC
PURPLE Negative
Emergency Supply
FROM Battery Pack
SELF-POWERED SIGN
Chassis GND
24 hours
Unswitched Supply
GREEN Ground
BLACK 105 to 360VAC
WHITE Neutral
LED Board
DUAL UNIVERSAL AC SIGN
From Generator OR
Emergency Supply
BROWN 105 to 360VAC
BLUE Neutral
NOTE: Cap unused AC Wire!
NOTE: Cap unused AC Wire!
24 hours
Unswitched Supply
GREEN Ground
BLACK 120VAC
RED 347VAC or ORANGE 200-277VAC
WHITE Neutral
24 hours
Unswitched Supply
Chassis GND LED Board
NOTE: Cap unused AC Wire!
GREEN Ground
BLACK 120VAC
RED 347VAC or ORANGE 200-277VAC
WHITE Neutral
24 hours
Unswitched Supply
Ni-Cd
Battery
Figure 1
Figure 3
Figure 2
Figure 4
BeLuce Canada Inc., 3900 14th Avenue, Unit 1, Markham, ON L3R 4R3 P: (905) 948-9500 F: (905) 948-8673

This manual suits for next models

1

Other BeLuce Lighting Equipment manuals

BeLuce QR-RM-PL User manual

BeLuce

BeLuce QR-RM-PL User manual

BeLuce QUADRA RECESSED User manual

BeLuce

BeLuce QUADRA RECESSED User manual

BeLuce MICRA B6L User manual

BeLuce

BeLuce MICRA B6L User manual

BeLuce STELLA SD User manual

BeLuce

BeLuce STELLA SD User manual

BeLuce BRUNO RM User manual

BeLuce

BeLuce BRUNO RM User manual

BeLuce OTTICA ECO RM User manual

BeLuce

BeLuce OTTICA ECO RM User manual

BeLuce TEMPESTA TA-RMT-LED User manual

BeLuce

BeLuce TEMPESTA TA-RMT-LED User manual

BeLuce SCALA User manual

BeLuce

BeLuce SCALA User manual

BeLuce BOXLED MINI User manual

BeLuce

BeLuce BOXLED MINI User manual

BeLuce MAXIMA TSL User manual

BeLuce

BeLuce MAXIMA TSL User manual

BeLuce STELLA SL-RM User manual

BeLuce

BeLuce STELLA SL-RM User manual

Popular Lighting Equipment manuals by other brands

X-Cite XCSK65RGB Installation & operating instructions

X-Cite

X-Cite XCSK65RGB Installation & operating instructions

Qlight QTG-WIZ user manual

Qlight

Qlight QTG-WIZ user manual

Exor MSM2000A Installation and commissioning instructions

Exor

Exor MSM2000A Installation and commissioning instructions

MegaLite AXIS 500 user manual

MegaLite

MegaLite AXIS 500 user manual

ecoStage ED MATRIX BEAM 14 user manual

ecoStage

ecoStage ED MATRIX BEAM 14 user manual

HAMPTON BAY 717-880 instruction manual

HAMPTON BAY

HAMPTON BAY 717-880 instruction manual

SilverStar FREZNO 250 HEX user manual

SilverStar

SilverStar FREZNO 250 HEX user manual

MegaLite DECO Cove Q18 user manual

MegaLite

MegaLite DECO Cove Q18 user manual

Show Tec LED Par 64 Short DMX user manual

Show Tec

Show Tec LED Par 64 Short DMX user manual

SilverStar CAM3/ETZ user manual

SilverStar

SilverStar CAM3/ETZ user manual

North Light HJ-8705 quick guide

North Light

North Light HJ-8705 quick guide

Show Tec Pocket LaserBeam owner's manual

Show Tec

Show Tec Pocket LaserBeam owner's manual

STUDIODUE TERRA 2101 user manual

STUDIODUE

STUDIODUE TERRA 2101 user manual

Night Stick NSR-2124 instruction manual

Night Stick

Night Stick NSR-2124 instruction manual

Lightmybricks LEGO PARISIAN RESTAURANT 10243 LIGHT KIT installation guide

Lightmybricks

Lightmybricks LEGO PARISIAN RESTAURANT 10243 LIGHT KIT installation guide

Qlight QEAL1 instruction manual

Qlight

Qlight QEAL1 instruction manual

NEBO NEB-LSP-0007 Use and care guide

NEBO

NEBO NEB-LSP-0007 Use and care guide

Chauvet OVATION F-265WW Quick reference guide

Chauvet

Chauvet OVATION F-265WW Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.