CAUTION
This equipment is furnished with a sophisticated low voltage battery dropout circuit to protect the battery from over-discharge
after it’s useful output has been used. Allow 24 hours recharge time after installation or power failure for full load testing.
INSTALLATION
RECESSED MOUNT - SINGLE FACE:
1. Extend unswitched 24 hour AC supply of rated voltage to junction box or appropriate wiring (supplied by others).
Leave at least eight (8) inches of slack wire. The circuit should not be energized at this time.
2. Remove the exit sign faceplate by unscrewing the 4 faceplate cover screws (Figure 1).
3. Knock out the appropriate mounting pattern and/or wire pass-thru hole on the exit back plate to fit the junction box or wiring connector
being used (supplied by others).
4. Bring wires through the back of the sign and mount the exit securely in place. Screw directly to junction box if possible.
5. Connect power supply as shown in Figure 3.
Insulate unused wire! CAUTION! - Failure to insulate unused wire may result in a shock hazard or unsafe condition as well as
equipment failure.
6. Route wires and secure them in place.
7. For self-powered units, insert test switch with nut and AC ON indicator (Figure 4) into the exit face as shown in Figure 5.
8. Remove any directional chevron arrows to be indicated as required from the exit stencil.
9. Replace the exit faceplate together with red fibre and secure with the faceplate cover screws.
10. Turn on the AC voltage supply.
SELF-POWERED:
1. For models QRR-SP, plug the battery into the circuit board per (Figure 3) self-powered sign.
MAINTENANCE
1. The equipment is to be repaired whenever the equipment fails to operate as intended during the duration test.
Written records of test results and any repairs made must be maintained. BeLuce Canada Inc. strongly recommends compliance with
all Code requirements.
2. The lamps listed herein when used according to the instructions with this unit are in accordance with the requirements
of CSA Standard C22.2, No. 141 – Unit Equipment for Emergency Lighting.
3. Clean exit face on a regular basis.
NOTE: The servicing of any parts should be performed by qualified service personnel only. The use of replacement
parts not furnished by BeLuce Canada Inc., may cause equipment failure and will void the warranty.
TROUBLESHOOTING
LEDS DO NOT COME ON AT ALL
1. Check AC supply be sure unit has 24 hour AC supply (unswitched).
The AC supply must be at least 80% of nominal (96V on a 120V line) for equipment to function normally.
At lower voltages the LED lamps will begin to glow dimly until the source voltage drops below the full “turn on” point.
NOTE: This condition may also be caused by incorrectly connecting an AC Volt supply line to the lead.
2. Check all AC connections
3. AC supply is OK, replace LED Board Assembly.
INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS
2. Disconnect power before performing work on electrical equipment.
3. Do not use outdoors.
4. Do not let power cords touch hot surfaces and do not mount near gas or electric heaters.
5. Use caution when servicing batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or
eyes, flush with fresh water and contact a physician immediately.
6. Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering.
7. The use of accessory equipment not recommended by BeLuce Canada Inc., may cause an unsafe condition, and will void the unit’s
warranty.
8. Do not use this equipment for other than its intended purpose.
9. Servicing of this equipment should be performed by qualified service personnel.
10. SAVE THESE INSTRUCTIONS!
QUADRA RECESSED (QRR)
926000137
BeLuce Canada Inc., 3900 14th Avenue, Unit 1, Markham, ON L3R 4R3 P: (905) 948-9500 F: (905) 948-8673
Chassis GND LED Board
AC ONLY SIGN
Chassis GND
GREEN Ground
BLACK 120VAC
RED 347VAC or ORANGE 200-277VAC
WHITE Neutral
LED Board
AC & UNIVERSAL DC SIGN
YELLOW Positive 6 to 24VDC
PURPLE Negative
Emergency Supply
FROM Battery Pack
SELF-POWERED SIGN
Chassis GND
24 hours
Unswitched Supply
GREEN Ground
BLACK 105 to 360VAC
WHITE Neutral
LED Board
DUAL UNIVERSAL AC SIGN
From Generator OR
Emergency Supply
BROWN 105 to 360VAC
BLUE Neutral
NOTE: Cap unused AC Wire!
NOTE: Cap unused AC Wire!
24 hours
Unswitched Supply
GREEN Ground
BLACK 120VAC
RED 347VAC or ORANGE 200-277VAC
WHITE Neutral
24 hours
Unswitched Supply
Chassis GND LED Board
NOTE: Cap unused AC Wire!
GREEN Ground
BLACK 120VAC
RED 347VAC or ORANGE 200-277VAC
WHITE Neutral
24 hours
Unswitched Supply
Ni-Cd
Battery
Figure 2Figure 1
Faceplate
Screw
Backplate
Frame
Mounting
Bracket
Faceplate
Screw
Backplate
Frame
Junction/Octagon
Box Not Supplied
Figure 3
Figure 5
Figure 4
(self-powered units only) (self-powered units only)
926000137
BeLuce Canada Inc., 3900 14th Avenue, Unit 1, Markham, ON L3R 4R3 P: (905) 948-9500 F: (905) 948-8673

Other BeLuce Lighting Equipment manuals

BeLuce BOXLED MINI User manual

BeLuce

BeLuce BOXLED MINI User manual

BeLuce MICRA B6L User manual

BeLuce

BeLuce MICRA B6L User manual

BeLuce MAXIMA TSL User manual

BeLuce

BeLuce MAXIMA TSL User manual

BeLuce BRUNO RM User manual

BeLuce

BeLuce BRUNO RM User manual

BeLuce TEMPESTA TA-RMT-LED User manual

BeLuce

BeLuce TEMPESTA TA-RMT-LED User manual

BeLuce STELLA SD User manual

BeLuce

BeLuce STELLA SD User manual

BeLuce QR-RM-PL User manual

BeLuce

BeLuce QR-RM-PL User manual

BeLuce MICRA RM User manual

BeLuce

BeLuce MICRA RM User manual

BeLuce OTTICA ECO RM User manual

BeLuce

BeLuce OTTICA ECO RM User manual

BeLuce SCALA User manual

BeLuce

BeLuce SCALA User manual

BeLuce STELLA SL-RM User manual

BeLuce

BeLuce STELLA SL-RM User manual

Popular Lighting Equipment manuals by other brands

LEGRAND 0 880 61 installation instructions

LEGRAND

LEGRAND 0 880 61 installation instructions

Ikan RB5-5PT-KIT quick start guide

Ikan

Ikan RB5-5PT-KIT quick start guide

EasyWay SPLENDOR SPL user manual

EasyWay

EasyWay SPLENDOR SPL user manual

Velleman HQ-Power HQPL11001 user manual

Velleman

Velleman HQ-Power HQPL11001 user manual

Govee H70B1 user manual

Govee

Govee H70B1 user manual

Endon Hal Wall instruction manual

Endon

Endon Hal Wall instruction manual

TDS HELIOS 6000 user manual

TDS

TDS HELIOS 6000 user manual

Lanta Fireball Par64 Tr Owner's handbook

Lanta

Lanta Fireball Par64 Tr Owner's handbook

InoTec CLS FUSION 7Ah Mounting and operating instructions

InoTec

InoTec CLS FUSION 7Ah Mounting and operating instructions

GTV LD-KNG24063-CB manual

GTV

GTV LD-KNG24063-CB manual

lap 930PG Instruction leaflet

lap

lap 930PG Instruction leaflet

SAKMA NOZZLE 60 quick start guide

SAKMA

SAKMA NOZZLE 60 quick start guide

ProLights Astra Profile400 user manual

ProLights

ProLights Astra Profile400 user manual

Kino Flo Celeb 850 LED DMX quick start guide

Kino Flo

Kino Flo Celeb 850 LED DMX quick start guide

ADJ 7PZ IP user manual

ADJ

ADJ 7PZ IP user manual

American DJ ROYAL 3D II User instructions

American DJ

American DJ ROYAL 3D II User instructions

Sealey LED3604G quick start guide

Sealey

Sealey LED3604G quick start guide

Hayward HL32950VVSP installation manual

Hayward

Hayward HL32950VVSP installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.