13
MENUFUNCTIONSettable valuesON-OFF-(Default)MEMO
LOGIC
Cvar The code programmable transmitters is enabled or disabled. On: Radio receiver enabled only for rolling-code transmitters. Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning and Dip Switch). OFFNOlS The operation mode of the amperometric sensor is selected ei-ther the limit switches are provided or not.On: Limit switches not provided. The amperometric sensor activation is interpreted by the control unit as limit switch. The control signal is sent to stop the movement. Note: To use this function, close the limit switch contacts with jumpers. The “SLD” Logic should be positioned to OFF
Off: Limit switches provided. The amperometric sensor activation is interpreted by the control unit as obstacle present in the gate movement area. Similarly to the safety edge activation, the con-trol signal is sent to stop and reverse movement for approx. 3s.
(OFF)2Ch The output performance at Terminals 9-10:On: The output has the function of 2nd radio channel: the nor-mally open contact switches for 1s at reception of a radio control assigned to the 2nd radio channel. See radio menu. Off: The output has the SCA function, open gate LED: open contact with closed gate, flashing light during gate movement, closed contact with open gate. See wire diagram.(OFF)serL Service light function is enabled or disabled on output 9-10.On: at each movement, the contact is closed for approx. 90s, regardless of the configuration of 2ch parameter. For the light control use the auxiliary relay. Off: The performance of the output is preset by 2ch parameter, see previous parameter.(OFF)MENUFUNCTION
RADIO
PP By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-by-step function.Press the transmitter key to be assigned to this function.If the code is valid, it is stored in memory and OK appears.If the code is not valid, the wording Err is displayed.2ch By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the second radio channel, on Terminals 9-10. The 2ch logic must be ON, the SERL logic must be OFF.Press the transmitter key to be assigned to this function.If the code is valid, it is stored in memory and OK appears.If the code is not valid, the wording Err is displayed.CLr By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory.If the code is valid, it is erase and OK appears. If the code is not valid or is not in memory, the wording Err is displayed.RTR Completely erase the receiver memory. Confirmation of operation is required.MENUFUNCTIONNMAN Displays the number of complete cycles (open+close) carried out by the automation. When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>> <PG> 3456: made 123.456 cycles.RES RESET of the control unit. ATTENTION!: Returns the control unit to the default values.Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit.Note: The transmitter codes are not erased from the receiver.Example of programmingLet us suppose it is necessary to:- set an automatic closing time (TCA) of 100s - activate pre-blinking Perform the operations described below step by step: