Page 6 724-746-5500 | blackbox.com
Hardened Ethernet Extender Quick Start Guide
• Ethernet port: Supports IEEE 802.3/802.3u/802.3x. Autonegotiation:
10/100 Mbps, full-/half-duplex; Auto MDI/MDI-X.
• Complies with IEEE 802.3at standard for high power input required device and
also compatible with IEEE 802.3af powered devices (Only available for Hardened
IEEE 802.3at PoE PSE Ethernet Extender version.)
• Ethernet Extender port (RJ-11 and terminal block): Symmetrical on the VDSL,
full-duplex 50-Mbps communications link over existing twisted-pair copper
telephone line.
• One DIP switch for configuring Local (Loc) and Remote (Rmt).
• Ten speeds with speed indicator LEDs on front panel of unit, up to 50 Mbps @
about 984 feet (300 meters), down to 1 Mbps @ about 6232 feet (1900
meters).
• 4-port 10/100BASE-TX (2-port IEEE 802.3at PoE PSE) Ethernet Extender: 2.88 A
@ 24 VDC, 1.44 A @ 48 VDC. Power consumption: 69.12 W Max.
• 2-port IEEE 802.3at PoE PSE Ethernet Extender: 2.88 A @ 24 VDC, 1.44 A
@ 48 VDC. Power consumption: 69.12 W Max.
• 1-port IEEE 802.3at PoE PSE Ethernet Extender: 1.6 A @ 24 VDC, 0.8 A
@ 48 VDC. Power consumption: 38.4 W Max.
• 4-port 10/100BASE-TX Ethernet Extender: 0.36 A @ 24 VDC, 0.18A @ 48 VDC.
Power consumption: 8.64 W Max.
• Power Supply: Redundant 24-48 VDC terminal block power inputs and 48 VDC.
DC jack with 100–240 VAC external power supply.
• Field Wiring Terminal Markings: Use copper conductors only, 140/167° F (60/75°
C), wire range 12-24 AWG, torque value 7 lb-in.
• Operating temperature range @ -40 to +167° F (-40 to +75° C). Tested for
functional operation @ -40 to +185° F (-40 to +85° C). UL®508 Industrial
Control Equipment certified. Maximum surrounding air temperature @ 167° F
(75° C).
• For use in Pollution Degree 2 Environment.
• Supports DIN rail, panel, and rackmounting installation.