Blueview CS0 User manual

THROUGH-HOLE LED MODULE
CS0
1
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
■Suitable for supermarkets, middle or large signage lighting, bars, ambient lighting, aviation and navigation signs, and etc.
Flat tail design
Anti-drop detent
■Through hole installation
Features
Application
Installation
3YearsR3528 2835 130°IP68
12V/48V
9mm through hole light, luminous diameter 9mm
Large light-emitting surface, give out light uniformly and evenly
Anti-drop detent design, suitable for mounting board of 1-4mm thickness
Flat tail design adopted soft material, easy to installation
Integrated injection shell, great waterproof performance with glue lling process
■
■
■
■
■
Version: A1.6

THROUGH-HOLE LED MODULE
CS0
2
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
Optical & Electrical Parameters
Model No. Luminous
Flux(lm/pcs)
Beam
Angle
Ecacy
(lm/W)
Voltage
(DC V)
Power
(W/pcs)
CRI
CS0
CS0
Y
Y
B
B
G
G
R
R
O
O
P
P
IB
IB
W
W
F
F
130°
130°
130°
130°
80+
80+
12
48
0.18
0.19
12
48
0.18
0.19
/
/
CCT/Wavelength
(K/nm)
2800-3200 92
6000-6500 95
8000-10000 92
15000-20000
9000-10000
11
19
90
100
620-625
620-625
520-525
520-525
460-465
460-465
585-590
570-575
600-610
600-610
/
/
475-485
475-485
/
/
4
3
24
15
11
5
63
28
2
2
11
10
20
15
39
76
7
8
110
43
9
8
62
43
11
13
13
68
2
11
48
57
Light Color
CS0
Other Parameters
1 50 50
LED Qty (pcs) Max Run(pcs)
1. Testing temperature: 25±2°C
2. The above data are typical values. The actual data of each single product may dier from the typical values.
3. Dierent color temperature or LEDs gears will make luminous ux dierent.
4. The "Quantity"above means the LED quantity of single product.
5. Luminous ux & power tolerance within ±10%.
6. Max. run quantity is in single feed
Standard Run(Pcs)
-20~+60℃-20~+70℃
Working Temperature Storage Temperature
Model No.

THROUGH-HOLE LED MODULE
CS0
3
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
Unit:mm[inch]
Prole Drawings
Note: for detail drawing,please consult sales rep.
CS0 Straw-hat LED light
Ordinary through-hole
SMD LED module
Luminous point VS Lighting spot
Luminous point: the size of the luminous part of the light
source observed by the eyes.
Lighting spot: The size of the projection formed by the
light source shining on the wall at a certain distance.
NOTE:
Unit:mm
=9
=36
Luminous point
Lighting spot =18 =12
=4.5 =3

THROUGH-HOLE LED MODULE
CS0
4
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
Luminous Intensity Distribution Diagram
AVERAGE BEAM ANGLE(50%): 133.4°
C0 /180,133.9°
Unit:cd
C90/270,132.8°
Average Illumination
Flux Out: 4.159lm (CCT=3200K)
Height Eavg,Emax Beam Angle: 132.74° Diameter
Note:The above two pictures are obtained when CS0-W at 3200K. If you need data and
parameters of other models, please contact the sales Rep

THROUGH-HOLE LED MODULE
CS0
5
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
Installation
Diagonal Pliers
Products and Tools
LED Power Supply Connection Terminals Gaer Tape
Model No. CS0
9+0.2
20-60
1-4
" "Hole size(mm)
"L" Distance(mm)
"H" Board thickness(mm)
Mounting board thickness and hole size
Through hole installation
Mounting Board
Anti-drop detent
Antiskid design
Hole
Mounting board

THROUGH-HOLE LED MODULE
CS0
6
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
suitable mounting board: H=1-4mm
Exposed channel letters installation
①②③④⑤
1. Clean the mounting surface.
2. Put the through-hole LED module into the reserved hole.
3. Cut the modules according to the requirements and make waterproof and insulating treatment for the cut wire ends.
4. If the product needs to be connected, it is better to x with connection terminals.
5. After that,light on for test.
Note: The wire ends must be insulated, waterproof and anti-corrosion treated, and shall not be pulled out with bare hands!
干
燥
剂
packing
① ② ③ ④
⑤ ⑥ ⑦
Desiccants
1. Prepare the desiccant and bind the product.
2. Put the product and desiccant into static shielding bag.
3. Seal and label the static shielding bag.
4. Put the static shielding bag side by side into carton box.
5. Seal the box.
6. Label the box.
7. Use packing belt to pack after adding the edge protectors.

THROUGH-HOLE LED MODULE
CS0
7
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
NOTE:
Packaging information
Available Installation Direction
Model No.
380*380*325 300 16 15.75(1±10%)14.25(1±10%)
19.5*20.6*10.6
Product Size L*W*H(mm) Carton Size(mm) Pcs/bag Bag/carton Gross Weight(kg)Net Weight(kg)
The above quantity and weight are only for the illustrated packaging method. There will be dierences in the quantity and weight with other packaging methods.
CS0
Do not apply pressure on the luminous soft shell and head,
otherwise it will deform and aect the luminous eect.
Horizontal Installation
Vertical Installation Acute Angle Installation Ceiling Installation
Obtuse Angled Installation

THROUGH-HOLE LED MODULE
CS0
8
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
Attentions before installation
This product currently has two voltages, 12V and 48V; In the same project, products with the same voltage are recommended.
In the same project, it is recommended to select products of the same batch. If not, the light color consistency must be veried rst.
This product has a soft shell, and the parts other than the anti-drop detent are not allowed to be aected by external force; otherwise, problems such as discoloration and
disconnection may occur.
If there is external force, it is recommended to use a hard shell product such as CS1.
It is strictly forbidden to use this product in the environment of obvious smoke, grease and other long-term emission of high volatile organic molecules (exhaust gas output
from engines, vehicles, or other oil-powered equipment); because it is easy to corrode the product and cause the product to change color and other performance decline.
When the temperature exceeds 60°C, the shell of the product will be deformed and the lighting eect will be aected.
Before installation, check that the product parameters are consistent with the requirements (Seeing product specications or product labels)
Load voltage, current, power and power supply should be matched with the product.
Follow the instructions of wiring diagram (rst connect the load and then the power supply) to avoid short circuit.
Make sure the correct connection of positive and negative poles between products and power supply. Otherwise, the light will not be on.
Make sure the power cord rmly screwed into the terminal and it should not be pulled out by hands.
The terminal should have insulation,waterproof and anti-corrosive treatment.
-
-
-
-
-
-
-
-
-
-
-
-
Quick Guide
Problems
All LEDs can not light on.
LEDs can not light on partly.
Brightness of LED is
inconsistent tor insucient.
LED icker.
Automatic power protection from the open or short
circuit in output of the power supply. Fix the short circuit problem.
Correctly connection.
Replace with more powerful power.
Make sure the working voltage of the product within ±5%
of standard voltage, or keep balance by circuit power
consumption.
Reduce the quantities of the product in series
connection to meet requirement.
Wrong connection of power supply.
Some switching mode power supplies are not powered.
Power supply line error.
Mistaken wire connection of some of products
Power overloaded.
Connection point fault. Remove bad connection point.
Replace a new power supply.
Please follow the instructions
Power supply circuit excessive consumption.
Excessive quantities in series connection of the product
Switching power supply failure.
Wrong Installation or use of products
Reasons
No electric supply.
Solutions
Common Faults and Troubleshoot
Warning
- Do not disassemble or retrot the light. Do not touch the surface of the light with a sharp object.
- Do not do live-line working during installation,especially for high voltage product.
- Do not use any organic chemical solvents.
- Use neutral glass adhesive to x this product and it needs to be dried 24 hours in the open environment after operation.
- Treat the ends and the circuit connection points that are not connected to the main line with insulation,waterproof, and anti-corrosion in the installation.
- Use 18AWG (0.75mm² cross-sectional area) or thicker core wire to avoid adverse consequences caused by overheating, if the power cable need to lengthen.
- Make sure the input voltage meets the requirements and lines are connected correctly before lighting on.
- This product is for signage, and do not use as general lighting.
- Series connection within the max run.
- The length of the power cable between the power supply and the led strip should not exceed 2 meters.Otherwise, large circuit loss will lead to inconsistent brightness.
- Installation, maintenance and repair should be operated by a qualied technician.

THROUGH-HOLE LED MODULE
CS0
9
■ Tel: +86-28-8148 0011
■ Fax: +86-28-8148 1258
■ Web.: www.blueviewled.com
■ Email: [email protected]
■ Add.: No. 1000, Section 2, Konggang 2nd Road, Shuangliu,
Chengdu 610207, Sichuan, CHINA
Statements and Recycling
- Before use, please read this specification carefully, and operate according to the instructions, otherwise the company will not
guarantee the quality, and will not be responsible for the consequences.
- Repair should be operated by a qualified technician, if the external circuit or main line of this product is damaged.
-The parameters given in this manual are typical values and for reference only.
-All illustrations and drawings in this manual are for reference.
-This product is subject to change without notice.
Statements:
- LED lighting products belongs to electronic products, please do recycling treatment according to the relevant WEEE directives.
Recycling:
Table of contents
Other Blueview Control Unit manuals