manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Control Unit
  8. •
  9. Honeywell ADEMCO 5800RL Assembly instructions

Honeywell ADEMCO 5800RL Assembly instructions

K3790 6/07 Rev.
B
A
DEMCO 5800RL
Wireless Relay Module
INSTALLATION AND SETUP GUIDE
INTRODUCTION
The ADEMCO 5800RL is a Wireless Relay Module that
enables use of remote sounders and/or remote arm/disarm
indicators using two relays activated by wireless signals from
the LYNX control (see Figure 1). The 5800RL can also send
tamper and supervision signals to the LYNX if so
programmed. The 5800RL is compatible with LYNX controls
having software versions 9.0 or higher. Refer to the LYNX
control installation and setup guide for software compatibility
and zone programming information.
5800RL
RELAY
MODULE
TAMPER AND
SUPERVISION
SIGNALS SENT
TO CONTROL
MODULE'S 2
RELAYS ARE
ACTIVATED BY
SYSTEM
CONDITIONS
AWAY
OFF
STAY
AUX
5800RF-004-V0
Figure 1. Lynx Interface Diagram
MOUNTING LOCATION GUIDELINES
Use the following guidelines when selecting a mounting
location for the 5800RL Relay Module (see Figure 2):
•Mount the 5800RL in a high location for best wireless
reception.
•Do not mount the 5800RL on or near metal objects. This
decreases range and/or blocks wireless transmissions.
•Locate the 5800RL at least 10 feet from any remote
keypad to avoid interference from the microprocessors in
those units.
•To avoid voltage loss that occurs on long power lines,
mount the external power supply unit in close proximity to
the 5800RL.
Mounting, Wiring, and Setup
IMPORTANT: Before permanently mounting the 5800RL,
perform the setup procedure described in the
Setting Up
the 5800RL
section.
1. Remove the 5800RL's cover from the base (using a small
flat head screwdriver, insert screwdriver’s tip in slot at top
of the cover and twist).
2. Using the 5800RL base as a template, position in the
desired location and mark the two mounting holes. See
Figure 2 for mounting hole locations.
3. Attach the 5800RL base using the fasteners supplied.
Screws and plastic anchors are suitable for a typical
installation, but you may use any two fasteners that
secure the base firmly to the mounting surface.
NOTE: This product uses latching relays, which retain their
open/closed position even when power is disconnected. Due
to shocks or vibration during shipment and installation, the
out-of-box state of these relays may be either open or closed.
When power is first applied, the relay will be set to its correct
initial state. Please bear this in mind during installation; it is
strongly recommended that you wire this module and apply
power to it before energizing any external circuit controlled by
the latching relay.
4. Connect relay and power wiring to the 5800RL’s terminals.
Refer to Figure 3 for a typical relay application.
The 5800RL can be powered from either an AC transformer
or DC power supply external power source connected to
terminals 7 and 8 (see Figure 3).
Power source ratings and connections are as follows:
Type Rating Connected to… Source Example
AC 9VAC, 15VA terminals 7 and 8 Ademco 1332
DC 9VDC, 100mA N7703
terminals 7 and 8
or plugged into
power connector.
NOTE: Use of power sources with higher or lower voltages
may result in damage or failure to operate properly. Non-
ADEMCO power supplies may have connectors installed.
Remove these connectors prior to attempting to connect
power supply to 5800RL.
TAMPER
SWITCH
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC ( ) IN
RELAY A
RELAY B
LED
(RED)
LED
(YELLOW)
LED
(GREEN)
RF INTERFERENCE
LED (RED)
ANTENNA 2
ANTENNA 1
DIP
SWITCH
MOUNTING
HOLE
MOUNTING
HOLE
123456
ON
OFF
Figure 2. 5800RL Diagram
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC ( ) IN
RELAY A
RELAY B
5800RL-005-V0
ANTENNA 2
SOUNDER
ANTENNA 1
123456
ON
OFF
ADEMCO AD12612
AUX PWR SUPPLY
(12 VDC)
AC
IN
+
_
DC
OUT
1361
+_
RED
BLACK
POWER SUPPLY
BACKUP
BATTERY 12VDC
+
PWR SUPPLY
XFMR
16.5VAC
Figure 3. Typical Sounder Wiring Installation
Setting Up the 5800RL
Refer to RELAY and LED Operation section and DIP Switch
(Figure 4) in order to set up the 5800RL as follows:
5. Set DIP switches 3-6 (Figure 4) to the appropriate House
ID (1-31). Make sure the House ID set by the DIP
switches matches that entered in the LYNX control.
6. If module supervision and/or tamper protection is desired,
program the 5800RL’s tamper/supervisory loop (1) as a
zone and enroll its serial number.
Note the following when enrolling:
Zone Type = 5 (trouble by day/alarm by night)
Input Type = 3 (RF)
Loop Number = 1
7. Position the wiring in the exit slot and reinstall the
5800RL’s cover on the base.
Test the 5800RL module with the rest of the system.
DIP SWITCH POSITIONS DIP SWITCH POSITIONS
HOUSE
ID 2 3 4 5 6
HOUSE
ID 2 3 4 5 6
0 - - - - - 16 - - - - -
1 - - - - ON 17 ON - - - ON
2 - - - ON - 18 ON - - ON -
3 - - - ON ON 19 ON - - ON ON
4 - - ON - - 20 ON - ON - -
5 - - ON - ON 21 ON - ON - ON
6 - - ON ON - 22 ON - ON ON -
7 - - ON ON ON 23 ON - ON ON ON
8 - ON - - - 24 ON ON - - -
9 - ON - - ON 25 ON ON - - ON
10 - ON - ON - 26 ON ON - ON -
11 - ON - ON ON 27 ON ON - ON ON
12 - ON ON - - 28 ON ON ON - -
13 - ON ON - ON 29 ON ON ON - ON
14 - ON ON ON - 30 ON ON ON ON -
15 - ON ON ON ON 31 ON ON ON ON ON
“ – “ indicates “OFF”
2 3 4 5 61
2-6 SETS HOUSE ID
SW-1
NOT USED
5800RL DIP Switch
5800RF-003-V0
OFF POSITION
INDICATOR
SV6
7L
Figure 4. DIP Switch Settings
RELAY and LED Operation
The 5800RL contains two relays (Figure 2) (SPDT, rated 2A.
28VAC/VDC) that may be used to activate remote sounders
and/or remote arm/disarm indicators. There are three LEDs
(green, yellow, red) located above the DIP switch and one
LED (red) located approximately in the center of the pc board.
The LEDs located above the DIP switch, indicate power and
relay activity. Refer to Figure 5. The RF Interference LED
monitors local radio frequency interference. If this LED is
continuously lit, the 5800RL should be relocated.
Relay LED Activates Upon…
A Yellow Alarm conditions as follows:
Steady ON = burglary alarm (NO contact
connects to COM)
Temporal ON = fire alarm (NO contact connects
temporal to COM)
OFF = no alarms present (NC contact connects
to COM)
Relay LED Activates Upon…
B Red System armed/disarmed as follows:
ON = system armed Away, Stay, or Instant (NO
contact connect to COM)
OFF = system disarmed (NC contact connects to
COM)
N/A Green Normally on (lighted) when power is applied.
Flickering indicates RF is being processed.
N/A RF
Inter-
ference
Lights when RF activity is present.
Figure 5. Relay and LED Operation
SPECIFICATIONS
Dimensions: 2-3/4”W x 4-15/16”H x 1-1/16”D
(70mm x 125mm x 27mm)
Voltage: 12VDC 100mA or
9VAC, 15VA (use ADEMCO 1332 or equivalent)
Current: 60mA
Relay: Two relays, each with choice of normally open (NO)
or normally closed (NC) operation.
Operating Temperature: 0 - 50°C / 32 - 122°F
Federal Communications Commission (FCC) Part 15
The user shall not make any changes or modifications to the equipment
unless authorized by the Installation Instructions or User's Manual.
Unauthorized changes or modifications could void the user's authority to
operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003
du Canada.
FCC/IC STATEMENT
This device complies with Part 15 of the FCC rules and RSS 210 of
Industry Canada. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme àla partie 15 des règles de la FCC & de RSS
210 des Industries Canada. Son fonctionnement est soumis aux
conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences
nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris
les interferences causant une reception indésirable.
ÊK37906Š
K3790 6/07 Rev. B
2 Corporate Center Drive, Melville, NY 11747
Copyright © 2007 Honeywell International Inc.
www.honeywell.com/security

Other Honeywell Control Unit manuals

Honeywell 7800 SERIES User manual

Honeywell

Honeywell 7800 SERIES User manual

Honeywell NOTIFIER M700 Series User manual

Honeywell

Honeywell NOTIFIER M700 Series User manual

Honeywell ADEMCO 4229 Assembly instructions

Honeywell

Honeywell ADEMCO 4229 Assembly instructions

Honeywell D06F User manual

Honeywell

Honeywell D06F User manual

Honeywell EXCEL 5000 OPEN T7460A User manual

Honeywell

Honeywell EXCEL 5000 OPEN T7460A User manual

Honeywell VR8215S User manual

Honeywell

Honeywell VR8215S User manual

Honeywell VGF User manual

Honeywell

Honeywell VGF User manual

Honeywell C7110C1040 User manual

Honeywell

Honeywell C7110C1040 User manual

Honeywell FIRE-LITE ALARMS CRF-300 User manual

Honeywell

Honeywell FIRE-LITE ALARMS CRF-300 User manual

Honeywell PRO3200 User manual

Honeywell

Honeywell PRO3200 User manual

Honeywell FV300 Technical specifications

Honeywell

Honeywell FV300 Technical specifications

Honeywell RM7838A Manual

Honeywell

Honeywell RM7838A Manual

Honeywell EXCEL 5000 OPEN ZAPP User manual

Honeywell

Honeywell EXCEL 5000 OPEN ZAPP User manual

Honeywell PENA D MLS2000SSP Installation and operation manual

Honeywell

Honeywell PENA D MLS2000SSP Installation and operation manual

Honeywell BCU 370 Manual

Honeywell

Honeywell BCU 370 Manual

Honeywell MI-DCZME User manual

Honeywell

Honeywell MI-DCZME User manual

Honeywell MAXON 8730 Series User manual

Honeywell

Honeywell MAXON 8730 Series User manual

Honeywell TC810E1040 User manual

Honeywell

Honeywell TC810E1040 User manual

Honeywell SILENT KNIGHT SK-FML User manual

Honeywell

Honeywell SILENT KNIGHT SK-FML User manual

Honeywell V4295A,S User manual

Honeywell

Honeywell V4295A,S User manual

Honeywell V5055A User manual

Honeywell

Honeywell V5055A User manual

Honeywell T7460B User manual

Honeywell

Honeywell T7460B User manual

Honeywell D05FS-A Series User manual

Honeywell

Honeywell D05FS-A Series User manual

Honeywell RA116A User manual

Honeywell

Honeywell RA116A User manual

Popular Control Unit manuals by other brands

Defi Defi-Link Advance Operation manual

Defi

Defi Defi-Link Advance Operation manual

Monacor img Stage Line TXS-820M manual

Monacor

Monacor img Stage Line TXS-820M manual

Neosun Energy NS48112-P user manual

Neosun Energy

Neosun Energy NS48112-P user manual

ATX ChromaFlex DMT24 Hardware Interface Manual

ATX

ATX ChromaFlex DMT24 Hardware Interface Manual

EOS Emotec D Installation and operating instructions

EOS

EOS Emotec D Installation and operating instructions

GEM R480 Victoria operating instructions

GEM

GEM R480 Victoria operating instructions

Pilz PNOZ m0p operating instructions

Pilz

Pilz PNOZ m0p operating instructions

Rock Seven RockBLOCK 9603 Developer's guide

Rock Seven

Rock Seven RockBLOCK 9603 Developer's guide

Mitsubishi Electric MELSEC iQ-R60DA4 Startup User's Manual

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R60DA4 Startup User's Manual

SMC Networks XLS Series Operation manual

SMC Networks

SMC Networks XLS Series Operation manual

Wellpro WP3076ADAM user manual

Wellpro

Wellpro WP3076ADAM user manual

Ei Electronics EIB600 Series manual

Ei Electronics

Ei Electronics EIB600 Series manual

Chiayo BT-500m Operation manual

Chiayo

Chiayo BT-500m Operation manual

Ingersoll-Rand X8I Operator's manual

Ingersoll-Rand

Ingersoll-Rand X8I Operator's manual

TriangleTube INSRKIT06 manual

TriangleTube

TriangleTube INSRKIT06 manual

Kontron COMe-cBT6 user guide

Kontron

Kontron COMe-cBT6 user guide

AKO 14917 instructions

AKO

AKO 14917 instructions

Woodward TecJet 52 Gen II Installation and operation manual

Woodward

Woodward TecJet 52 Gen II Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.