BMZ 24555 series User manual

BMZ-GmbH
Am Sportplatz 28-30
D-63791 Karlstein am Main
Germany
www.bmz-gmbh.de
24555_Bedienungsanleitung_20150616
BEDIENUNGSANLEITUNG / OPERATING INSTRUCTION
LADEGERÄT / CHARGER 42Vdc 4A
Artikel Nr. / Part No. 24555-x
Geeignet zum Laden eines
10 Zellen in Serie / 36V, max. 25Ah Li-Ion Akkupack
Suitable to charge a
10 cells in serial / 36V, max. 25Ah Li-Ion Battery pack
Bedienungsanleitung vor Gebrauch sorgfältig lesen!
Read this operating instruction carefully before use!

Allgemeine Sicherheitshinweise
Bedienungsanleitung vor Gebrauch sorgfältig lesen!
Bei unsachgemäßem Umgang mit Lithium-Batterien
besteht Brand-, Explosions- und Ätzgefahr! Unbedingt
Angaben des Akkuherstellers beachten!
Nur Li-Ion Akkupacks laden. Keine Blei-, NiCd-, NiMh- oder
nicht ladbare Primärzellen laden!
Das Ladegerät nur an dafür geeignete Spannungsquellen
anschließen. Bei längerem Nichtgebrauch,
Spannungsversorgung des Gerätes trennen und
angeschlossene Akkus abklemmen.
Dieses Gerät kann von Kindern ab 8 Jahren und darüber
sowie von Personen mit verringerten physischen,
sensorischen oder mentalen Fähigkeiten oder Mangel an
Erfahrung und Wissen benutzt werden, wenn sie
beaufsichtigt oder bezüglich des sicheren Gebrauchs des
Gerätes unterwiesen wurden und die daraus resultierenden
Gefahren verstehen. Kinder dürfen nicht mit dem Gerät
spielen. Reinigung und Benutzer-Wartung dürfen nicht von
Kindern ohne Beaufsichtigung durchgeführt werden.
Das Ladegerät ist für den Betrieb in belüfteter, trockener
und staubfreier Umgebung vorgesehen. Keinesfalls Regen
oder großer Hitze aussetzen. Gerät nicht abdecken.
Das Ladegerät sauber und trocken halten.
Keinen überhitzten Akkupack laden – der Akkupack muss
zuvor auf Umgebungstemperatur abgekühlt sein.
Brechen Sie den Ladevorgang ab wenn sich der Akkupack
zu sehr erhitzt. (>55-60°C)
Das Ladegerät bei Beschädigung nicht in Betrieb nehmen.
Gerät nicht öffnen oder Änderungen vornehmen.
Reparaturen dürfen nur von autorisiertem Fachpersonal mit
original Ersatzteilen durchgeführt werden.
General Safety Instructions
Read these operating instructions carefully before use!
Improper handling of Lithium Batteries may cause fire,
explosion or chemical danger.
Check battery manufacturer instructions.
Charge only Li-Ion battery packs. Do not charge Lead Acid-,
NiCd- NiMh or non-rechargeable primary batteries. Connect
the charger to a suitable mains supply, only. Disconnect the
charger from mains and the battery pack if it is not in use for
a longer time.
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
The charger is designed for usage in a damp-free, dry and
ventilated environment.
Do not expose the charger to rain or hot conditions. Don’t
cover the charger.
Please keep the charger clean and dry.
Do not charge hot battery packs. Battery packs must be at
ambient temperature before charging.
Stop the charging process if the battery gets to hot during
charging. (>55-60°C)
Do not use the charger if there are any signs of damage.
Do not open the charger or carry repairs. Repairs may be
carried from authorized personal with original spare parts,
only.

Functions
1. This charger is suitable to charge a 36 Volt Li-Ion battery pack,
10 cell in serial. The max. charge current is 4 A. The max.
capacity of the battery pack can be 25 Ah.
2. The charger has an overload, short circuit, overvoltage and
wrong polarity protection.
Overload protection (cut off if the output current is higher than 7A)
Short circuit (cut off if there is a short circuit on the DC-side)
Overvoltage protection (cut off if the output voltage is higher than
50V)
Wrong polarity protection (cut off if battery with wrong polarity is
connected to the charge cable)
3. This charger has an additional charge capacity counter that cuts
off the charge after 25Ah are charged into the battery pack. This
is also indicated as error.
4. The charger has an internal temperature control that protects the
charger at to high ambient temperature as well as continuous
overload. If this happens the charger will reduce the output
power.
5. Errors are shown by the flashing red LED.
Operation
1. Before first use please check the parameters of the charger and
your battery according the rating label or the manual to ensure
the accordance.
2. Check if that the local main AC voltage level is suitable for the
charger.
Minimal
Nominal Maximal
AC input voltage 207 230 264
3. For a function test plug in the mains cable into an AC mains
socket. The green LED will flash slow, that indicates stand by.
4. Now connect the DC cable to battery pack. The green LED will
flash equally and shows that charging is started. If the battery
voltage is less than <25V the charger will start with a pre-charge
current of 500mA. If a battery voltage of >25V is not reached
within 30. min. the charger will cut off. This is indicated as error.
In this case please contact your battery supplier. When the
voltage is reached, the charger will automatically switch to fast
charge.
5. If the battery pack is fully charged the charger cuts off. The green
LED will give a steady light and indicates the full battery pack.
With some batteries the charger will start after 2 seconds to
charge again. It will stop a few seconds later when it recognizes
the fully charged battery. This can repeat again. It will not
damage the battery.
6. The charger has an internal temperature control that protects the
charger at to high ambient temperature as well as continuous
overload. If this happens the charger will reduce the output power
until recovery.
Status LED Indicators
LED red LED green
Stand by off slow flash 10% on
Pre charge off flash 50% on
Charge off flash 50% on
Battery full off steady (for 2 seconds)
Error flash off
Charge end voltage 42 V +/-1%
Remarks
This charger has a wrong polarity protection. The right polarity is
the base that the charger generates a charge voltage. Depending
on the battery safety board, a battery pack that is discharged
under it’s nominal discharge voltage can’t be charged again. In
this case please contact your battery supplier.
Error through reaching the capacity limit or the pre charge limit,
will be reset immediately after removing the battery. Error through
short circuit or wrong polarity will be reset automatically maximum
1min after removing the Problem.
Content
1. Charger with dc cable
2. AC Power cord
3. Operating instructions

Funktionen
1. Dieses Ladegerät ist zum Laden eines Li-Ion Akkupacks mit
nominal 36 Volt, 10 Li-Ion Zellen in Serie, geeignet. Der
Ladestrom beträgt max. 4 A. Die max. Kapazität des Akkus kann
bis zu 25 AH sein.
2. Das Ladegerät besitzt Überstrom-, Kurzschluss-,
Überspannungs- und Verpolschutz.
Überstromschutz (Abschaltung sobald der Ausgangsstrom größer
ist als 7A)
Kurzschlussschutz (Abschaltung bei Kurzschluss auf der DC-
Seite)
Überspannungsschutz (Abschaltung sobald die
Ausgangsspannung größer ist als 50V)
Verpolschutz (Abschaltung wenn ein falsch gepolter Akkupack
am Ladekabel angeschlossen ist)
3. Das Ladegerät besitzt einen zusätzlichen Kapazitätszähler
welcher die Ladung nach eingeladenen 25Ah abbricht. Dies wird
als Störung angezeigt.
4. Das Gerät besitzt eine Temperaturüberwachung welche das
Gerät bei zu hoher Umgebungstemperatur wie auch
Dauerüberlastung schützt. In diesem Fall wird die
Ausgangsleistung reduziert.
5. Bei Störung blinkt die rote LED.
Betrieb
1. Vor der Erstinbetriebnahme überprüfen Sie die Parameter des
Ladegerätes und Ihres Akkus anhand der Angaben auf dem
Typenschild bzw. der mitgelieferten Dokumentationen auf
Übereinstimmung.
2. Überprüfen Sie ob die Netzspannung für das Ladegerät geeignet
ist. Minimal Nominal Maximal
Eingangsspannung (Volt)
207 230 264
3. Zur Funktionsüberprüfung stecken Sie den Stecker des
Ladegerätes in die Steckdose. Die grüne LED blinkt langsam bei
Bereitschaft.
4. Verbinden Sie dann das Ladekabel (DC-Kabel) mit Ihrem Akku.
Die grüne LED blinkt gleichmäßig und signalisiert, dass der
Ladevorgang gestartet wurde. Bei zu geringer Akkuspannung
(<25VDC) wird der Akku mit einem Vorladestrom von ca. 500mA
geladen. Die grüne LED blinkt gleichmäßig. Dieser Vorgang
dauert max. 30 Minuten. Wird in dieser Zeit die
Spannungsschwelle von 25VDC nicht überschritten schaltet das
Ladegerät ab, es liegt ein Akkudefekt vor. Das Ladegerät zeigt
Störung. Kontaktieren Sie in diesem Fall den Akkulieferant.
Werden 25V erreicht, schaltet das Gerät automatisch auf
Schnellladen um.
5. Ist der Akku voll aufgeladen schaltet das Ladegerät ab. Die grüne
LED leuchtet dauernd und zeigt den voll aufgeladenen Akku an.
Bei einzelnen Akkupacks startet der Ladevorgang nach ca. 2
Sekunden erneut schaltet aber kurz darauf wieder ab. Dies kann
sich dauernd wiederholen. Der Akkupack wird hierdurch nicht
geschädigt.
6. Das Gerät besitzt eine Temperaturüberwachung welche das
Gerät bei zu hoher Umgebungstemperatur wie auch
Dauerüberlastung schützt. In diesem Fall wird die
Ausgangsleistung reduziert bis sich eine stabile
Betriebstemperatur einstellt.
Status LED Anzeige
LED rot LED grün
Bereitschaft aus langsam blinken 10% an
Vorladung aus blinken 50% an
Ladevorgang
aus blinken 50% an
voll geladen aus dauernd (ca. 2sec.)
Störung blinken aus
Ladeschlussspannung 42 V +/-1%
Anmerkungen
Das Ladegerät besitzt einen Verpolschutz. Der richtige Anschluss
an einen Akku ist die Voraussetzung, dass das Ladegerät eine
Ausgangsspannung erzeugt. Sollte der Akku unter seine nominale
Entladeschlussspannung entladen worden sein, ist es möglich,
dass sich der Akku nicht mehr laden lässt. Bitte wenden Sie sich
in diesem Fall an den Akkuhersteller.
Fehler, durch überschreiten des Kapazitätszählers oder der
Vorladezeit, werden zurückgesetzt sobald der Akku entfernt
wurde. Fehler durch Kurzschluss oder falsche Polarität, werden
automatisch maximal 1min. nach beseitigen des Fehlers
zurückgesetzt.
Lieferumfang
1. Ladegerät mit Ladekabel
2. AC Anschlussleitung mit Stecker
3. Kurzanleitung
Other BMZ Batteries Charger manuals