Engineered Solutions | AMC2 - Input/Output Extension Boards
AMC2 - Input/Output Extension Boards
www.boschsecurity.com
uRS485 connection to the AMC2 controller
uThree models available one with 8 inputs & 8
outputs, one with 16 inputs & 16 outputs, and one
with 16 inputs
uStatus of inputs and outputs shows on AMC2 LCD
display
uTransfer rate to EXT interface (RS485): 9,6 kBit/sec
uThe AMC2 Extensionboards can be supplied with
the PBC-60 power supply unit with integrated UPS.
The AMC2 16I-16O-EXT, the AMC2 16I-EXT and/or the
AMC2 8I‑8O-EXT extension boards can only be used
with the AMC2 access controller and provides
additional input and output contacts.
The AMC2 controller has eight input and eight output
signals. The AMC2 determines the door status (open
or closed) via the analog input signals. The relay
outputs can be used to activate locking mechanisms,
for example.
If there are not enough contacts available on the AMC2
to transfer the necessary signals, up to three AMC2 xI-
xO-EXT units can be connected to provide additional
inputs and outputs.
Notice
Systems with Access Personal Edition Software
can only connect one I/O-Extension to an AMC2
Controller.
The electronics are located in a plastic housing, similar
to the one on the AMC2 controller.
The AMC2 16I-16O-EXT has 16 analog inputs and 16
relay outputs. It receives door status signals via the
inputs and can authorize door releases or send
messages to external surveillance systems via the
outputs.
Reduced versions of the extension board are also
obtainable to make full use of the available signals.
The AMC2 8I-8O-EXT module has eight input and eight
output signals. The AMC2 16I-EXT has 16 analog
inputs.
System overview
The AMC2 xxx-EXT is integrated into the system via the
AMC2 controller.
1 = Host computer
2 = AMC2
3 = Card reader
4 = Communication and power supply
5 = AMC2 xxx-EXT
In the default configuration, the connection to the
AMC2 is established via the RS485 interface.
Installation/configuration notes
Up to three extension boards can be connected to one
AMC2 controller; this provides a maximum of 56 input
and output signals for configuration with the AMC2
signals.
For a system configuration the AMC2 16I-16O-EXT,
AMC2 16I-EXT, and AMC2 8I-8O-EXT can also be used
in combination, e.g. two AMC2 16I-16O-EXTs and one
AMC2 8I-8O-EXT – but the maximum number of
modules that can be connected is also restricted to
three per AMC2 controller.
Notice
Systems with Access Personal Edition Software
can only connect one I/O-Extension to an AMC2
Controller.
An AMC2 16I-16O-EXT can only provide signals for the
entrances of the AMC2 controller to which it is
connected. It is not possible to transmit to another
AMC2.
Configuration examples:
Solid lines: Power supply
Dotted lines: Data lines
1. AMC2 with power supply.
2. Power and data are supplied to the AMC2 xxx-EXT via
the AMC2.
3. The AMC2 xxx-EXT with its own power supply
receives data from the AMC2.
4. The first AMC2 xxx-EXT is supplied by the AMC2 - the
second has its own power supply and a connection to
the third. All AMC2 xxx-EXTs receive their data from
the AMC2.
Power supply
An external power supply (10 to 30 V DC) for the
AMC2 is connected to the first (positive) and third pin
(negative).
When using an uninterruptible power supply (UPS),
the relevant UPS output relay is connected to the pins
• 4 and 7 for alternating current (AC)
• 5 and 7 for the battery
• 6 and 7 for direct current (DC)
Otherwise, these pins will short-circuit.
Voltage equalization - grounding
• Different grounds can be balanced via jumpers with
protective ground.
• A line (shielding, potential equalization) with
protective ground must only be connected in one
place.
• For further instructions, please see the operating
manual.
2 | AMC2 - Input/Output Extension Boards
Contacts
Inputs
The analog inputs can be used as digital or analog
contacts. For analog use, resistance values can be
specified to check for cable breaks and short-circuits.
Relay outputs
The relay outputs offer the following functions:
• The outputs can operate with potential free contacts
for external power supply (dry mode).
• The outputs can operate using the internal voltage of
power supply (wet mode).
• Only ohm resistive loads can be connected to the
relay.
• Inductive loads must be bypassed via recovery
diodes. These diodes (IN4004) are enclosed.
General instructions
• All access equipment should be mounted within a
"secured area".
• Detailed connection conditions are specified in the
operating manual!
• After purchase, primary AC power must be carried
out by a licensed electrician.
Technical specifications
Hardware 16 or 8 or null relay outputs - with ohm load:
- max. switching voltage: 30 V DC
- max. switching current: 1,25 A
16 or 8 analog inputs
Tamper switch
Temperature 0°C to +45°C (32° F to 113° F)
Power supply - 10 or 30 V DC, max. 60 VA
Available for external devices: 55 VA
- or via the AMC2
Protection
class
IP 30
Housing Base: PPO (UL 94 V-0)
Upper: Polycarbonate (UL 94 V-0)
Color White
Dimensions WxHxD: 232 x 90 x 46 mm (9.13 x 3.54 x 1.81 in.)
Weight Approx. 0.4 kg (0.88 lb)
Type Rail mounting
Ordering information
AMC2 8I-8O-EXT
8 input/output extension board, up to three per AMC,
can be combined with the AMC2 16I-EXT and the
AMC2 16I-16O-EXT
Order number API-AMC2-8IOE
AMC2 16I-16O-EXT
16 input/output extension board, up to three per AMC,
can be combined with the AMC2 16I-EXT and the
AMC2 8I-8O-EXT
Order number API-AMC2-16IOE
AMC2 16I-EXT
16 input extension board, up to three per AMC, can be
combined with the AMC2 16I-16O-EXT and the AMC2
8I-8O-EXT
Order number API-AMC2-16IE
3 | AMC2 - Input/Output Extension Boards
4 | AMC2 - Input/Output Extension Boards
Represented by:
Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
[email protected]
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
[email protected]
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
[email protected]
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
201 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
[email protected]
www.boschsecurity.com
© Bosch Security Systems 2013 | Data subject to change without notice
1354705675 | en, V2, 13. Nov 2013

Other manuals for AMC2 Series

6

This manual suits for next models

6

Other Bosch Controllers manuals

Bosch CR 400 User manual

Bosch

Bosch CR 400 User manual

Bosch ME 200 User manual

Bosch

Bosch ME 200 User manual

Bosch ARC C-2 User manual

Bosch

Bosch ARC C-2 User manual

Bosch MAP User guide

Bosch

Bosch MAP User guide

Bosch REG 73-1 User manual

Bosch

Bosch REG 73-1 User manual

Bosch B443 User manual

Bosch

Bosch B443 User manual

Bosch FW 200 User manual

Bosch

Bosch FW 200 User manual

Bosch PVA-4CR12 User manual

Bosch

Bosch PVA-4CR12 User manual

Bosch MP 100 User manual

Bosch

Bosch MP 100 User manual

Bosch BAT 251 User manual

Bosch

Bosch BAT 251 User manual

Bosch HPC User manual

Bosch

Bosch HPC User manual

Bosch CRC200 User manual

Bosch

Bosch CRC200 User manual

Bosch Smart Home controller II Operator's manual

Bosch

Bosch Smart Home controller II Operator's manual

Bosch Rexroth CKL Series Guide

Bosch

Bosch Rexroth CKL Series Guide

Bosch WORCESTER GREENSTAR WIRING CENTRE User guide

Bosch

Bosch WORCESTER GREENSTAR WIRING CENTRE User guide

Bosch Rexroth Indramat ECODRIVE DKC02.1 Series Technical manual

Bosch

Bosch Rexroth Indramat ECODRIVE DKC02.1 Series Technical manual

Bosch WORCESTER Sense II User manual

Bosch

Bosch WORCESTER Sense II User manual

Bosch Rexroth NYS04.2-ST-02-LMSN-NY4073 User manual

Bosch

Bosch Rexroth NYS04.2-ST-02-LMSN-NY4073 User manual

Bosch Rexroth IndraDrive C HCS03.1 Technical manual

Bosch

Bosch Rexroth IndraDrive C HCS03.1 Technical manual

Bosch MPC-8000-C User manual

Bosch

Bosch MPC-8000-C User manual

Bosch Rexroth Diax 04 User manual

Bosch

Bosch Rexroth Diax 04 User manual

Bosch CLIMATE 5000 VRF RDCI Series Instruction Manual

Bosch

Bosch CLIMATE 5000 VRF RDCI Series Instruction Manual

Bosch AMC2-16IOE User manual

Bosch

Bosch AMC2-16IOE User manual

Bosch Rexroth IndraDrive HMS02 User manual

Bosch

Bosch Rexroth IndraDrive HMS02 User manual

Popular Controllers manuals by other brands

GE PACSystems* RX3i Command Line Interface Manual

GE

GE PACSystems* RX3i Command Line Interface Manual

Barco Sedomat 5800 Specifications

Barco

Barco Sedomat 5800 Specifications

Elko HRH-4 manual

Elko

Elko HRH-4 manual

Wiedamark SR-2820-US3 quick start guide

Wiedamark

Wiedamark SR-2820-US3 quick start guide

OPTO 22 G4LC32ISA-LT user guide

OPTO 22

OPTO 22 G4LC32ISA-LT user guide

BIFFI ICON3000 Series Advanced Maintenance Instructions

BIFFI

BIFFI ICON3000 Series Advanced Maintenance Instructions

WEG CP-D user manual

WEG

WEG CP-D user manual

Alpha Technologies Cordex CXC HP Hardware manual

Alpha Technologies

Alpha Technologies Cordex CXC HP Hardware manual

Mitsubishi FX3U Series user manual

Mitsubishi

Mitsubishi FX3U Series user manual

Deif AGC 200 Series quick start guide

Deif

Deif AGC 200 Series quick start guide

Missouri Wind and Solar 200ECCDIGSSR quick start guide

Missouri Wind and Solar

Missouri Wind and Solar 200ECCDIGSSR quick start guide

Sub-Zero Mega Chill user manual

Sub-Zero

Sub-Zero Mega Chill user manual

Epic RS232 PRO manual

Epic

Epic RS232 PRO manual

Maxcess D-MAXE operating instructions

Maxcess

Maxcess D-MAXE operating instructions

Elsner KNX eTR Sunblind Series Installation and adjustment

Elsner

Elsner KNX eTR Sunblind Series Installation and adjustment

Siemens RDF870KN operating instructions

Siemens

Siemens RDF870KN operating instructions

Renogy WANDERER manual

Renogy

Renogy WANDERER manual

norbar T-BOX 2 Operator's manual

norbar

norbar T-BOX 2 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.