Bosch AMC2 Series User manual

AMC2 enclosure with 1 DIN rail
AEC‑AMC2‑UL01
en Installation manual


AMC2 enclosure with 1 DIN rail Table of contents | en 3
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
Table of contents
1System overview 4
1.1 Components of the enclosure 4
1.2 Parts included 6
2Mounting the enclosure 8
3Connections 9
3.1 Connecting the devices 9
3.2 Connecting the cables 11
3.3 Connections for supporting Universal Power Supply 13
3.3.1 12 V mode operation 14
3.3.2 24 V mode operation 16
4Appendices 18
4.1 UL requirements 18
4.2 More information 19

4en | System overview AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
1 System overview
1.1 Components of the enclosure
1 2 3 4
6
78
11
12
13
9
5
10
Figure1.1: Components of the enclosure
Position Description
1 Cover grounding point
2 Mounting rail for power supply unit (PSU) and
Access Modular Controller (AMC2)
3 AMC2 grounding point
4 Cable knock-outs for reader and signal cables
5 Temperature sensor bracket
6 Tamper contact
7 Fixing bracket for rechargeable batteries
8 Main grounding point

AMC2 enclosure with 1 DIN rail System overview | en 5
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
Position Description
9 Label
10 Knock-out for the power cable connection
11 Three pin connector
12 Bracket for LED
13 Name plate

6en | System overview AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
1.2 Parts included
x3
x1
x1
x1
x1
x1
x1
x2A B
C
FG
I
H
x1
D
E

AMC2 enclosure with 1 DIN rail System overview | en 7
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
Position Description
A Cable ties to secure cables
B Three screw anchors S8 and M6 × 50 screws
C Bracket for cable fixing
D Cover grounding cable
E Battery cable
F Power supply cable (AMC2)
G Power supply cable (battery)
H Cover contact wired
I Power cable with LED indicator (UL required)

8en | Mounting the enclosure AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
2 Mounting the enclosure
The enclosure is designed to be mounted on a wall.
1. Open the door lock of the enclosure with the provided key.
2. Hold the enclosure at the desired position against the wall.
3. Mark the mounting holes on the wall with a pencil.
4. Put the enclosure aside.
5. Drill the holes at the points that you previously marked on
the wall.
6. Insert the screw anchors in the drilled holes.
7. Drive the screws halfway into the top and bottom left screw
anchors.
8. Hang the enclosure on the wall, according to the position of
the screw anchors.
9. Drive the third screw into the anchor on the bottom right.
10. Tighten all screws.
– The enclosure is installed.
86,5 mm
3,406 in
401 mm
15,787 in
352,5 mm
13,878 in
5 mm
0,197 in
318 mm
12,52 in
10 mm
0,394 in
5 mm
0,197 in
10 mm
0,394 in
200,5 mm
7,894 in
Figure2.1: Dimensions of the enclosure

AMC2 enclosure with 1 DIN rail Connections | en 9
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
3 Connections
3.1 Connecting the devices
Precondition: Install readers and other peripheral devices as
described in the corresponding technical documentation.
AC
N G L1
BAT RTH
Power Supply
AMC2 controller /
AMC2 extension
DC
RS-485 EXT T
---- OK ----
L N + - + - + -C DC BAT AC 1 2 3 4 5 6 7
1 2 3 4 5 6 1 2
2
1
F
X
G
I
H
Figure3.1: Connections in the enclosure
1. Insert the cables of the device through the knock-outs at
the top-right side wall of the enclosure, or through the rear
of the enclosure.
2. Provide an appropriate disconnect device to the supply
line.
!
Warning!
Risk of electric shock!
Disconnect the mains supply voltage before you work on the
devices inside the enclosure.

10 en | Connections AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
Installing the components
1. Mount the Access Modular Controller (AMC2) on the right-
hand side of the mounting rail.
2. Mount the power supply unit on the left-hand side of the
mounting rail.
3. If you are using rechargeable batteries, install the batteries
at the bottom of the enclosure and secure them with a
fixing bracket.

AMC2 enclosure with 1 DIN rail Connections | en 11
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
3.2 Connecting the cables
Connecting the AMC2 power cable (F)
1. Connect the 7-pin plug to the AMC2 connector labeled
POWER.
2. Connect the 4-pin plug to the power supply connector
labeled OK.
3. Connect the 2-pin plug to the power supply connector
labeled DC.
4. Connect the grounding cable to the AMC2 grounding point.
Mounting and connecting the power cable with LED indicator
(I)
1. Pass the cable end through the front of the LED bracket
hole (Figure 1, position 12).
2. Carefully pull the cable through the back of the LED
bracket.
3. Make sure that the LED reaches and fits the LED bracket
hole.
4. Connect the single brown wire to position 3, marked with L
(Figure 3.2).
5. Connect the other end from the brown wire to position 1
(Figure 3.2).
6. Connect the single blue wire to the position 4, marked with N
(Figure 3.2).
7. Connect the other end from the blue wire to the position 2
(Figure 3.2).

12 en | Connections AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
AC
N G
L1
BAT RTH
L N + -
Figure3.2: Connections of the LED indicator
Connecting the tamper contact (H)
1. Connect the loose ends of the tamper contact cable to the
two-pin screw connector (marked with T) at the top of the
AMC2.
2. Position the cable in the space between the housing and
the mounting rail.
Danger!
Risk of electric shock
Make sure that all wires have zero potential.
Connecting the main AC supply (X)
1. Connect the ground cable to the main grounding point
(Figure 1.1, position 8).
2. Connect the neutral wire to terminal N (Figure 3.2).
3. Connect the phase wire to terminal L1 (Figure 3.2).
4. Shorten the external supply wires so that the ground wire
is a minimum of 20 mm longer than the live wires.
– This will prevent the ground wire from being
accidentally disconnected.

AMC2 enclosure with 1 DIN rail Connections | en 13
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
Connecting the cover grounding cable (D)
1. Connect the mounted grounding cable (see position D of
Parts included, page 6
) to the cover grounding point
(Figure 1.1, position 1) and to the grounding point on the
cover of the enclosure.
2. Make sure that the screws of the two earthing points are
sufficiently tightened.
Refer to
– Parts included, page 6
3.3 Connections for supporting Universal
Power Supply
Precondition: Before switching to battery operation, disconnect
the AC power cable.
Use the battery cable with the fuse (G) for the battery
connection.
i
Notice!
Use 12V 7 (7,2)Ah lead batteries only.
i
Notice!
Change the lead batteries every 5 years.

14 en | Connections AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
3.3.1 12 V mode operation
i
Notice!
Make sure that the power supply has the correct output voltage
(12V).
+ -
G
1a
2a
1b 2b
+ - + -
G
1a 1b 2a 2b
Figure3.3: 12V mode with one battery (left); 12 V mode with two batteries
(right)
12V mode operation using one battery
1. Set the switch of the power supply unit to 12V.
2. Connect the 2-pin plug to the power supply interface
labeled BAT.
3. Connect 1b (black) to the rechargeable negative (-)
terminal of the battery.
4. Connect 1a (red) to the rechargeable positive (+) terminal
of the battery.
5. Attach the bracket (C) to the back of the housing next to
the batteries.
6. Attach the connectors 2a and 2b to the bracket.

AMC2 enclosure with 1 DIN rail Connections | en 15
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
12 V mode operation using two batteries
1. Set the switch of the power supply unit to 12V.
2. Connect the 2-pin plug to the power supply interface
labeled BAT.
3. Connect 1b (black) to the rechargeable negative (-)
terminal of the battery.
4. Connect 1a (red) to the rechargeable positive (+) terminal
of the battery.
5. Connect 2b (black) to the second rechargeable negative (-)
terminal.
6. Connect 2a (red) to the second rechargeable positive (+)
terminal of the battery.

16 en | Connections AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
3.3.2 24V mode operation
i
Notice!
Make sure that the power supply has the correct output voltage
(24V).
+ - + -
G
E
1a 1b
Figure3.4: 24V mode
Connecting the battery cables
1. Set the switch of the power supply unit to 24V.
2. Connect the 2-pin plug to the power supply interface
labeled BAT.
3. Connect 1a (red) to the positive (+) pin of the first
rechargeable battery.
4. Connect 1b to the negative (-) pin of the second
rechargeable battery.
5. With cable E (blue), connect the negative (-) pin of the first
rechargeable battery to the positive (+) pin of the second
rechargeable battery.

AMC2 enclosure with 1 DIN rail Connections | en 17
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
6. Attach the connectors 2a and 2b to the bracket.
7. Attach the bracket (C) to the back of the housing next to
the batteries.

18 en | Appendices AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
4 Appendices
4.1 UL requirements
i
Notice!
All cables connected to the AMC2 modules and the power
supply are classified as Class 2 conductors. The battery cable
and the AC input cable are non-power limited circuits.
i
Notice!
Maintain a minimum of 6.4 mm spacing between all class 2 or 3
conductors and all electric, light, power, Class 1 conductors,
non-Class 2 or 3 signaling conductors, or medium-power
network-powered broadband communications-circuit
conductors (Figure 3.1, position 1 and 2).
i
Notice!
When the fuse (5A) of cable B (power supply battery) is blown,
replace it with a UL listed fuse and reseal the fuse holder with a
heat shrink tube.
i
Notice!
If the system is to be UL294 compliant, make sure that all the
cables and the respective parts are UL listed or approved.
Access Control Performance Levels UL 294
Line Security Destructive
Attack
Endurance Standby
Power
I I IV II

AMC2 enclosure with 1 DIN rail Appendices | en 19
Bosch Security Systems B.V. 2021-03 | V06 | F.01U.330.018
4.2 More information
For product manufacturing dates, go to
www.boschsecurity.com/datecodes/ and refer to the serial
number on the product label.
Support
Access our support services at www.boschsecurity.com/xc/en/
support/.
Bosch Security and Safety Systems offers support in these
areas:
–Apps & Tools
–Building Information Modeling
–Commissioning
–Warranty
–Troubleshooting
–Repair & Exchange
–Product Security
Bosch Building Technologies Academy
Visit the Bosch Building Technologies Academy website and
have access to training courses, video tutorials and
documents: www.boschsecurity.com/xc/en/support/training/
Visit the Bosch online product catalog for the latest technical
documentation for this product.

20 | Appendices AMC2 enclosure with 1 DIN rail
2021-03 | V06 | F.01U.330.018 Bosch Security Systems B.V.
Other manuals for AMC2 Series
6
This manual suits for next models
1
Table of contents
Other Bosch Enclosure manuals

Bosch
Bosch AE20 User manual

Bosch
Bosch AEC-AMC2-UL01 User manual

Bosch
Bosch AMC2 Series User manual

Bosch
Bosch CPH 0006 A User manual

Bosch
Bosch AMC2 VdS User manual

Bosch
Bosch AE2 User manual

Bosch
Bosch AE20 User manual

Bosch
Bosch FPA-5000 User manual

Bosch
Bosch HCP 0006 A User manual

Bosch
Bosch D203 Operating and maintenance instructions