Intrusion Alarm Systems | DS938Z and ZX938Z Series Panoramic PIR Detectors
DS938Z and ZX938Z Series Panoramic PIR
Detectors
www.boschsecurity.com
uMotion Analyzer II processing
uMotion Monitor
uSelf-test supervision systems
uChangeable mirrors
u360° x 18 m (60 ft) diameter pattern
These ceiling mount, 18 m (60 ft) panoramic PIR
Detectors use Motion Analyzer II processing to reduce
false alarms. The series consists of the:
• DS938Z Panoramic Detector
• ZX938Z Panoramic Detector with POPIT
Several unique self-test features, including Motion
Monitor, provide coverage integrity. Field replaceable
mirrored optics allow them to be mounted on ceilings
from 2.5 m to 6 m (8 ft to 18 ft) in height.
Functions
Motion Analyzer II Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration, and
polarity of signals to make an alarm decision. It will
not alarm on extreme levels of thermal and
illumination disturbances caused by heaters and air
conditioners, hot and cold drafts, sunlight, lightning,
and moving headlights. Provides three sensitivity
settings.
PIR Supervision
PIR supervision provides trouble output in the event
that PIR circuitry fails.
Motion Monitor
Switch-selectable four or thirty day Motion Monitor
supervision timers provide the detector with the ability
to verify that there is a clear view of the protection
area and that it has not been blocked.
Test Features
Three externally visible high output alarm LEDs visible
from any angle, flash to indicate trouble condition.
Internal noise voltage test pins provide precise pattern
location and background disturbance evaluation using
a standard analog meter.
Certifications and approvals
These detectors have also been designed to meet the requirements of:
Europe DS938Z complies with EN50131‑1, Grade 2
France AFNOR NF, A2P
Region Certification
Australia RCM [DS938Z]
Europe CE 2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive
(LVD); 2011/65/EU Restriction of the
[DS938Z][DS938Z-FRA]
EN5013
1
EN50131-2-4, Grade 2 [DS938Z-FRA]
USA UL DS938Z: ANSR: Intrusion Detection
Units (UL639)
UL ZX938Z: ANSR: Intrusion Detection
Units (UL639)
France AFNOR 260001760A1 [DS938Z-FRA]
China CCC DS938Z: 2002031901000002
CCC DS938Z-CHI: 2004031901000036
Sweden INTYG DS938Z only: 04-683
Installation/configuration notes
0 m
9 m 9 m
0 ft
30 ft
30 ft
Top View
360° x 18 m (60 ft) diameter
30 ft
0 ft
10 ft
9 m
0 m
3 m
30 ft
9 m
0 ft
0 m
AR8-13 Side View
360° x 18 m (60 ft) diameter
0 ft
30 ft 30 ft
0 ft
10 ft
15 ft
0 m
9 m 9 m
0 m
3 m
4.5 m
AR13-18 Side View
360° x 18 m (60 ft) diameter
Technical specifications
Enclosure Design
Material: High impact ABS plastic enclosure
Dimensions: 8.4 cm x 13.3 cm
(3.3 in. x 5.25 in.)
Environmental Considerations
Operating Temperature: -29°C to +49°C (-20°F to +120°F)
For UL Listed Applications,
0°C to + 49°C (+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies
in the range from 26 MHz to 950 MHz at
50 V/m.
DS938Z: Complies with Environmental Class II
(EN50130-5)
Mounting
Height (recommended): 2.5 m to 6 m (8 ft to 18 ft)
Location: Mounts directly to ceiling or to standard
octagonal electrical box.
Internal Pointability: Coverage is adjustable ±10° horizontally,
+2° to -18° vertically.
Outputs (DS models)
Alarm: Form C reed relay at 3.0 W, 125 mA at 28 VDC for
resistive loads
Tamper: Normally-closed. Contacts rated at 28 VDC, 125 mA
maximum.
Outputs (ZX model)
Alarm: Signal through POPEX data bus.
Tamper: Signal through POPEX data bus. Signaled as missing.
Trouble: Signal through POPEX data bus.
Power Requirements (DS models)
Current: 18 mA at 12 VDC
Voltage: 6 VDC to 15 VDC
2 | DS938Z and ZX938Z Series Panoramic PIR Detectors
Power Requirements (ZX model)
Current: < 0.5 mA nominal, 2 mA in alarm with LED enabled
Voltage: Power comes from two-wire POPEX bus.
Note: Do not leave Walk Test LEDs enabled.
Ordering information
DS938Z Panoramic Detector
Provides PIR, 360° x 18 m (60 ft) diameter coverage
and 2.5 m to 6 m (8 ft to 18 ft) mounting height.
Order number DS938Z
DS938Z‑CHI Panoramic Detector
For use in China. Provides Motion Analyzer II
processing, movable mirrors, and 360° x 18 m (60 ft)
diameter coverage.
Order number DS938Z-CHI
DS938Z‑FRA Panoramic Detector
Provides PIR, 360° x 18 m (60 ft) diameter coverage
and 2.5 m to 6 m (8 ft to 18 ft) mounting height. For
use in France.
Order number DS938Z-FRA
ZX938Z Panoramic Detector
Provides PIR, 360° x 18 m (60 ft) diameter coverage
and 2.5 m to 6 m (8 ft to 18 ft) mounting height with
internal POPIT.
Order number ZX938Z
Accessories
AR13‑18‑3 Optical Module
Designed for 4 m (13 ft) to 6 m (18 ft) mounting
height. Shipped in packages of three.
Order number AR13-18-3
TC6000 Test Cord
Test cord for connecting a compatible detector’s test
pins to a voltmeter. It is 4.6 m (15 ft) long.
Order number TC6000
3 | DS938Z and ZX938Z Series Panoramic PIR Detectors
Represented by:
Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
[email protected]
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
[email protected]
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
[email protected]
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
201 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
[email protected]
www.boschsecurity.com
© Bosch Security Systems 2014 | Data subject to change without notice
2628903563 | en, V9, 17. Mar 2014

This manual suits for next models

3

Other Bosch Security Sensor manuals

Bosch RADION contact SM User manual

Bosch

Bosch RADION contact SM User manual

Bosch PAVIRO Series User manual

Bosch

Bosch PAVIRO Series User manual

Bosch FCP-320 Series User manual

Bosch

Bosch FCP-320 Series User manual

Bosch RF940E Operation and maintenance manual

Bosch

Bosch RF940E Operation and maintenance manual

Bosch D-tect 150 User manual

Bosch

Bosch D-tect 150 User manual

Bosch GMS 120 Professional User manual

Bosch

Bosch GMS 120 Professional User manual

Bosch AVENAR detector4000 User manual

Bosch

Bosch AVENAR detector4000 User manual

Bosch DS935Z User manual

Bosch

Bosch DS935Z User manual

Bosch Blue Line P1 User manual

Bosch

Bosch Blue Line P1 User manual

Bosch Blue Line Q1 User manual

Bosch

Bosch Blue Line Q1 User manual

Bosch DS1103i User manual

Bosch

Bosch DS1103i User manual

Bosch 520 Series User manual

Bosch

Bosch 520 Series User manual

Bosch ISN?SM?80 User manual

Bosch

Bosch ISN?SM?80 User manual

Bosch Truvo User manual

Bosch

Bosch Truvo User manual

Bosch WEU PDO 6 User manual

Bosch

Bosch WEU PDO 6 User manual

Bosch FAA-420-RI-ROW User manual

Bosch

Bosch FAA-420-RI-ROW User manual

Bosch DS778 User manual

Bosch

Bosch DS778 User manual

Bosch FCP-320 Series User manual

Bosch

Bosch FCP-320 Series User manual

Bosch ISN-SM-50 User manual

Bosch

Bosch ISN-SM-50 User manual

Bosch DS939 User manual

Bosch

Bosch DS939 User manual

Bosch RF940E Series User manual

Bosch

Bosch RF940E Series User manual

Bosch DS432i-CHI User manual

Bosch

Bosch DS432i-CHI User manual

Bosch FAP-420 Series Owner's manual

Bosch

Bosch FAP-420 Series Owner's manual

Bosch WEU PDO Multi User manual

Bosch

Bosch WEU PDO Multi User manual

Popular Security Sensor manuals by other brands

EsiWelma Sensigas URS20SE manual

EsiWelma

EsiWelma Sensigas URS20SE manual

Protrol IPC4020 user manual

Protrol

Protrol IPC4020 user manual

Wavetronix SmartSensor HD user guide

Wavetronix

Wavetronix SmartSensor HD user guide

Kidde KI-PHD Installation sheet

Kidde

Kidde KI-PHD Installation sheet

Elkron VSD3 installation manual

Elkron

Elkron VSD3 installation manual

Sperian ToxiPro Reference manual

Sperian

Sperian ToxiPro Reference manual

Risco WL T6S installation instructions

Risco

Risco WL T6S installation instructions

WAGNER TITANUS RACK-SENS 1U Technical manual

WAGNER

WAGNER TITANUS RACK-SENS 1U Technical manual

System Sensor B501A Installation and maintenance instructions

System Sensor

System Sensor B501A Installation and maintenance instructions

Mhouse MAD5 Instructions for installation

Mhouse

Mhouse MAD5 Instructions for installation

Rielta FOTON-SH2-RK installation guide

Rielta

Rielta FOTON-SH2-RK installation guide

Uniden R9 user manual

Uniden

Uniden R9 user manual

SCS Sentinel KA-SA03 user manual

SCS Sentinel

SCS Sentinel KA-SA03 user manual

Siemens L-852A-D Dualite manual

Siemens

Siemens L-852A-D Dualite manual

Linde G-TECTA 4G operating manual

Linde

Linde G-TECTA 4G operating manual

Clas Ohlson 36-2285 quick start guide

Clas Ohlson

Clas Ohlson 36-2285 quick start guide

iRay Technology Mars1417VS user manual

iRay Technology

iRay Technology Mars1417VS user manual

Mace 80200 manual

Mace

Mace 80200 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.