manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bradley
  6. •
  7. Control Unit
  8. •
  9. Bradley Equa-Flo S59-1005SR User manual

Bradley Equa-Flo S59-1005SR User manual

Installation
P.O. Box 309
Menomonee Falls, WI 53052 USA
800 BRADLEY (800 272 3539)
+1 262 251 6000
www.bradleycorp.com
215-1674 Rev. F: ECO 19-03-024
© 2020 Bradley
Page 1 of 3 1/8/2020
S59-1005SR
Bradley Equa-Flo™HD Ligature
Resistant Pressure-Balancing
Shower Valve
Table of Contents
Safety Information ............................... 2
Supplies Required ............................... 2
Rough-In ...................................... 3
Connect Valve and Adjust Valve Temperature.......... 4
Attach Escutcheon and Handle ..................... 4
Read the instructions in this manual before beginning installation.
Save these instructions and refer to them for inspection,
maintenance, and troubleshooting information.
For questions regarding the operation, installation or maintenance of this product, visit bradleycorp.com or
call 800.BRADLEY (800.272.3539).
Product warranties and parts information may also be found under “Resources” on our website at
bradleycorp.com.
For use with shower heads rated
at 5.7 L/min (1.5 gpm) or higher.
S59-1005SR Installation
21/8/2020 Bradley • 215-1674 Rev. F: ECO 19-03-024
Safety Information
To ensure proper operation:
Installation
Failure to comply with proper installation and maintenance instructions could contribute to a valve failure resulting in severe bodily
injury including scalding, chilling, and/or death depending upon system water pressure changes and/or supply water temperature
changes.
Hot limit screw is set in the maximum temperature position. Failure to properly adjust may result in serious scalding. This valve
may not protect from scalding if there is a failure of other temperature-controlling devices elsewhere in the plumbing system.
Excessive heat may cause damage to internal parts.
This valve is intended to be installed as an ASSE 1016 valve- at the point of use, where the user has access to flow or final
temperature controls. This valve should not be used where an ASSE 1017, ASSE 1069, or ASSE 1070 device is required.
Make sure that all water supply lines have been flushed and are then completely turned off before beginning installation. Debris in
supply lines can cause valves to malfunction.
Installation of this system must be completed by a qualified plumber in compliance with all national and local codes. Compliance
and conformity to local codes and ordinances is the responsibility of the installer. Should these codes differ from the information in
the manual, follow the local codes. Inquire with governing authorities for additional local requirements.
Inspection
Regular checking and cleaning of the valve's internal components and check stops is necessary for maximum life and proper
product function. Periodic inspection and yearly maintenance by a licensed contractor is required. Corrosive water conditions
and/or unauthorized adjustments or repairs could render the valve ineffective for its intended service. Frequency of cleaning and
inspection depends upon local water conditions.
Supplies Required:
• Teflon Tape
• Allen key wrenches
• Screwdriver
• 1/2" NPT Brass pipe plug
• Adjustable wrench
• 100% Silicone Sealant
• Semi-Permanent Threadlocker
• Security sealant (if required)
• Silicone Grease (supplied)
Installation S59-1005SR
Bradley • 215-1674 Rev. F: ECO 19-03-024 1/8/2020 3
• Rough-in 1/2" NPT hot and cold water supply piping (supplied by installer) as shown below.
• For finished wall, make a 4-1/2" hole in the wall where the shower handle is desired.
HOT
COLD
SUPPLIES REVERSED
STANDARD INSTALL
Contact your Bradley
Representative and ask for
S45-2264 Back-to-Back Rotor
Kit to swap out the rotor on the
reversed side.
"Back-to-Back" Installation
6-1/2" (165)
w/Stops
2-1/2" (64)
w/o Stops
Hot Cold
1-3/4"
(46)
(mm)
Rough-in
1
WARNING! In order for the shower to be ligature resistant, the valve inlet and outlet rough-ins
must be 4" (±1/8").
2-1/8"
(53)
1-1/2"
(38)
1-1/2"
(38)
48"
(1219)
Above
Finished
Floor
2-1/4"
(56)
4"*
(103)
4-5/8"*
(119)
Finished Wall
1/2" NPT Inlets
and Outlets
1/2" NPT
Pipe Plug
(By Installer)
Valve must
be 90° to wall
* Dimension can be ±1/8"
S59-1005SR Installation
41/8/2020 Bradley • 215-1674 Rev. F: ECO 19-03-024
APosition valve with port labeled “UP” towards showerhead.
Connect valve to hot and cold supplies and showerhead
or tub spout supplies (see rough-in diagram.)
B
Turn on hot and cold supplies to pressurize valve and check for
leaks. (Valve will not operate unless both hot and cold supplies
are turned on.) Adjust maximum temperature by turning set
screw on valve cap.
C
H
E
Insert the 4 screws through the
escutcheon and into the valve body.
Tighten the screws, making sure that
the escutcheon is flush with the wall or
fixture and all 4 screws are tightened
equally.
WARNING! The temperature limit stop has been
factory preset for maximum temperature
operation. Failure to adjust the limit screw
to a safe shower temperature could result
in the user being scalded.
Connect Valve and Adjust Valve Temperature
2
Attach Escutcheon and Handle
3
DApply 100% silicone caulk to all
screw backsides prior to escutcheon
installation.
A
Slide handle over stem. Apply semi-
permanent thread locker to set screw
and tighten to ensure the screw is fully
engaged.
BApply supplied silicone
grease to o-ring to guide
escutcheon in place.
CSlide escutcheon on
valve and align all 4
holes.
FApply security sealant
(if required) as
described below.
After installation, all joints
require security sealant (by
installer) to eliminate gaps,
if present, between the wall
and fixture.

Other Bradley Control Unit manuals

Bradley EFX 120 Series User manual

Bradley

Bradley EFX 120 Series User manual

Bradley Equa-Flo HD Operation manual

Bradley

Bradley Equa-Flo HD Operation manual

Bradley S59-2005T1 User manual

Bradley

Bradley S59-2005T1 User manual

Bradley E90-252 HFP Guide

Bradley

Bradley E90-252 HFP Guide

Bradley S19-2000EFX Series User manual

Bradley

Bradley S19-2000EFX Series User manual

Bradley S19-2200 User manual

Bradley

Bradley S19-2200 User manual

Bradley EFX60 User manual

Bradley

Bradley EFX60 User manual

Bradley Equa-Flo HD S59-1005 User manual

Bradley

Bradley Equa-Flo HD S59-1005 User manual

Bradley S67-610 User manual

Bradley

Bradley S67-610 User manual

Bradley AST4 Operation manual

Bradley

Bradley AST4 Operation manual

Bradley Equa-Flo EFT1 User manual

Bradley

Bradley Equa-Flo EFT1 User manual

Bradley Navigator S59-4007 User manual

Bradley

Bradley Navigator S59-4007 User manual

Bradley EFX 8 User manual

Bradley

Bradley EFX 8 User manual

Bradley EFX 60 S19-2200 Series User manual

Bradley

Bradley EFX 60 S19-2200 Series User manual

Bradley S59-2007 User manual

Bradley

Bradley S59-2007 User manual

Bradley TouchTime S45-1941 User manual

Bradley

Bradley TouchTime S45-1941 User manual

Bradley HL 200 User manual

Bradley

Bradley HL 200 User manual

Bradley EFX 20/S19-2150 User manual

Bradley

Bradley EFX 20/S19-2150 User manual

Bradley S90-252 HFP Guide

Bradley

Bradley S90-252 HFP Guide

Bradley S59-5000 Series User manual

Bradley

Bradley S59-5000 Series User manual

Bradley EFX 20-2150 User manual

Bradley

Bradley EFX 20-2150 User manual

Bradley S19-2100 User manual

Bradley

Bradley S19-2100 User manual

Bradley Navigator S59-4000 User manual

Bradley

Bradley Navigator S59-4000 User manual

Bradley EFX25 User manual

Bradley

Bradley EFX25 User manual

Popular Control Unit manuals by other brands

IDTECH SecureHead user manual

IDTECH

IDTECH SecureHead user manual

Control Technologies CTI 2451 Installation and operation guide

Control Technologies

Control Technologies CTI 2451 Installation and operation guide

digi-tech AA-0377 user manual

digi-tech

digi-tech AA-0377 user manual

Paradox ZX82 installation manual

Paradox

Paradox ZX82 installation manual

Multitech MultiConnect Dragonfly MTQ-LVW3 Series Device guide

Multitech

Multitech MultiConnect Dragonfly MTQ-LVW3 Series Device guide

GiBiDi AS06321 Instructions for installation

GiBiDi

GiBiDi AS06321 Instructions for installation

SimCom SIM7060 Series Application note

SimCom

SimCom SIM7060 Series Application note

Kieback&Peter RBW322-FTL-902 operating instructions

Kieback&Peter

Kieback&Peter RBW322-FTL-902 operating instructions

Delta DVP-ES2 manual

Delta

Delta DVP-ES2 manual

IMG STAGE LINE PLL-8 instruction manual

IMG STAGE LINE

IMG STAGE LINE PLL-8 instruction manual

Black Box MTU200CF-N64 manual

Black Box

Black Box MTU200CF-N64 manual

KEBCO COMBIVERT 00F6V80-001A Instructions for use

KEBCO

KEBCO COMBIVERT 00F6V80-001A Instructions for use

GiBiDi DSC90 manual

GiBiDi

GiBiDi DSC90 manual

SIGMA TEK PL 221 instruction manual

SIGMA TEK

SIGMA TEK PL 221 instruction manual

7bit Wicher 508i user guide

7bit

7bit Wicher 508i user guide

Krom Schroder LSV operating instructions

Krom Schroder

Krom Schroder LSV operating instructions

Delta DIGI-LAN user manual

Delta

Delta DIGI-LAN user manual

Sun Power E Series Safety and installation instructions

Sun Power

Sun Power E Series Safety and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.