2
5
Identify the
required position of
the valve and prepare
the water supply pipes.
Supply pipes should be
150mm apart.
Using the rubber fixing
plate supplied with the
wall mount, mark and
drill holes.
Secure the isolatorSecure the isolator
onto the backplateonto the backplate
ensuring the olive isensuring the olive is
positioned over thepositioned over the
pipework correctly.pipework correctly.
Push shrouds to thePush shrouds to the
back of the wall outlet,back of the wall outlet,
securing them againstsecuring them against
the rubber fixing plate.the rubber fixing plate.
4
3
1
15mm
Compression
Installation
150mm Centres
Rotate the shroud untilRotate the shroud until
the opening aligns withthe opening aligns with
the isolation screw.the isolation screw.
Turn the screw to isolateTurn the screw to isolate
the water. Reverse thethe water. Reverse the
process when turningprocess when turning
the water back on.the water back on.
1
Isolation 2
Remove the concealingRemove the concealing
cap from the shroud.cap from the shroud.
Secure the rubber backplateSecure the rubber backplate
and backplate into place.and backplate into place.
Secure the shower toSecure the shower to
the wall mount.the wall mount.
21mm21mm
REMEMBER
To service
your
product!
Operation
IMPORTANT
Pack Contents
150mm
Centres
1.0
5.0
Pressure
BAR
0.2
4.0
2.0 3.0
Pressure
BAR
1.0
5.0
0.2
4.0
2.0 3.0 60°C
65°C
Specifications
Maximum Static Pressure: 10.0 bar
Inlet Water Temperature
15mm
Compression
Inlet Connections
Min: 0.2 bar Max: 5.0 bar
Working Pressures
The inlet hot water must
be at least 10°C above the
required blend temperature.
Factory pre-set
42°C
Inlet Dimensions
5°C
25°C
Cold Water Supply
Min: 5°C Max: 25°C
Hot Water Supply
Tools You’ll need
Flat head Screwdriver Cross head Screwdriver Hexagonal Keys
Pipe Cutter
Pencil Drill Spanner
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product Code: CRZ SHXDIVCTFF C (D2)
All products manufactured and supplied by Bristan are safe to use provided that
they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and
current by-laws. For full Installation Requirements & Notes (IRN) please
visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future
maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the
guarantee.
Full access must be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or
the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Prior to Installation
60-65°C Recommended
REMEMBER
hot on the left,
cold on the
right
HotHot
ColdCold
On - FixedOn - Fixed
HeadHead
On -On -
HandsetHandset
x2 x2
x2
x2
x8
x8
x2
x2
x2
x2
x4
x1
x1
x1
x1
x1
x1
x1
x1
x1
Safety Glasses Detector
4
1
56
4
4
2
1
Remove
temperature
handle.
Turn flow handle to ‘on’
position, letting the
temperature stabilise.
Turn cartridge spindle clockwise
to decrease the temperature.
Turn cartridge spindle
anti-clockwise to increase the
temperature.
3
2
5
Troubleshooting
To reduce the build up of limescale and to ensure this shower works
to its maximum performance we recommend this shower is serviced
every 6-12 months depending on the hardness of your water.
To replace any spare parts for
your shower why not scan the
below QR Code and search for
your product.
Spare Parts
Servicing Intervals
Temperature Setting
Maintenance - Cartridge Cleaning
3
1
6
Symptom Cause Remedy
No flow or
low flow rate
Partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on and o
as flow rate or pressure is too low.
Increase water flow rate or pressure through system.
Head of water is below the minimum
distance required.
2 meters minimum required.
Hot or cold water being drawn o elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Do not use other water outlets when using the shower.
Airlock or partial blockage in the supply pipe
work.
Flush through pipe work to ensure removal of debris and
any airlocks.
Water
dripping
from shower
This is normal for a short time after using the
shower.
This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip, possibly due to the
cartridge
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Shower does
not turn on
Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer solid guarantees
on all our products, eective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors
will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
Riser Installation 23
Press & hold
knob on the
bracket to slide
up or down.
Using a spirit level
to ensure the
riser is positioned
correctly, use
the assembled
riser to mark the
desired position
of the bracket.
Drill holes. Secure the
bracket to the wall.
Secure the riser
bracket and riser
rail.
Attach the fixed
head.
To adjust height
of head twist
the knob and
slide the riser to
desired height.
Slide the
bracket onto the
riser rail, then
push the riser
extension onto
the riser rail.
Tighten grub
screws at the
back.
12
Reverse steps 1-2 to
reinstall the cartridge
and handle.
Remove O-rings
and soak all
components in
de-scaler and
wash o in clean
water. Examine all
seals and replace
if needed.
Use WRAS
approved silicon
based grease on
all seals.
12
Reverse steps 1-2 to
reinstall the valve and
secure handles.
7
REMEMBER
To service
your
product!
89
Remove
temperature
and flow
handle.
Remove nut,
spline adaptor
and flow valve.
ReplaceReplace
cartridge andcartridge and
turn spindleturn spindle
anti-clockwiseanti-clockwise
to maximumto maximum
temperature.temperature.
Replace
nut and
temperature
stop,
ensure the
raised side is
facing towards
the back of the
valve.
Turn cartridge spindle clockwise to
decrease the temperature. Turn
cartridge spindle anti-clockwise to
increase the temperature.
Slide handle onto
adaptor and turn
clockwise until you
meet resistance.
Remove spline
adaptor,
temperature
stop, nut, and
cartridge.

Other Bristan Plumbing Product manuals

Bristan Java J BASNW C User manual

Bristan

Bristan Java J BASNW C User manual

Bristan AR3 SHCDIV C Wiring diagram

Bristan

Bristan AR3 SHCDIV C Wiring diagram

Bristan W BASIN07 C Wiring diagram

Bristan

Bristan W BASIN07 C Wiring diagram

Bristan Quest User manual

Bristan

Bristan Quest User manual

Bristan QD SHXSMFF C D3 Wiring diagram

Bristan

Bristan QD SHXSMFF C D3 Wiring diagram

Bristan Buzz Wiring diagram

Bristan

Bristan Buzz Wiring diagram

Bristan Artisan User manual

Bristan

Bristan Artisan User manual

Bristan Opac Series Mounting instructions

Bristan

Bristan Opac Series Mounting instructions

Bristan Jute JU BF C User manual

Bristan

Bristan Jute JU BF C User manual

Bristan RO2 SHXAR C Mounting instructions

Bristan

Bristan RO2 SHXAR C Mounting instructions

Bristan ALP Series Wiring diagram

Bristan

Bristan ALP Series Wiring diagram

Bristan K 1/2 C Wiring diagram

Bristan

Bristan K 1/2 C Wiring diagram

Bristan W BASIN13 C Wiring diagram

Bristan

Bristan W BASIN13 C Wiring diagram

Bristan DUL2 SHXARFF C Wiring diagram

Bristan

Bristan DUL2 SHXARFF C Wiring diagram

Bristan SMILE SM 1/2 C D6 Wiring diagram

Bristan

Bristan SMILE SM 1/2 C D6 Wiring diagram

Bristan CR SHXDIVFF C Wiring diagram

Bristan

Bristan CR SHXDIVFF C Wiring diagram

Bristan Cadet Wiring diagram

Bristan

Bristan Cadet Wiring diagram

Bristan Colonial K BRSNK C User manual

Bristan

Bristan Colonial K BRSNK C User manual

Bristan EF KIT PK Wiring diagram

Bristan

Bristan EF KIT PK Wiring diagram

Bristan RS2 BSM C (D3) Wiring diagram

Bristan

Bristan RS2 BSM C (D3) Wiring diagram

Bristan ELVIRA SHWR PK Mounting instructions

Bristan

Bristan ELVIRA SHWR PK Mounting instructions

Bristan Moloko User manual

Bristan

Bristan Moloko User manual

Bristan Nero NRBSME6C Wiring diagram

Bristan

Bristan Nero NRBSME6C Wiring diagram

Bristan Regency Luxury R BSM C Wiring diagram

Bristan

Bristan Regency Luxury R BSM C Wiring diagram

Popular Plumbing Product manuals by other brands

Sanela 93230 Mounting instructions

Sanela

Sanela 93230 Mounting instructions

Porcelanosa noken FORMA 100123292 N399999816 quick start guide

Porcelanosa

Porcelanosa noken FORMA 100123292 N399999816 quick start guide

Spectrum Brands Pfister Kelen LG89-XMF Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Kelen LG89-XMF Quick installation guide

FORENO TRIJET FSL3 quick start guide

FORENO

FORENO TRIJET FSL3 quick start guide

Sapho WD139 installation manual

Sapho

Sapho WD139 installation manual

Hans Grohe Croma Showerpipe 220 EcoSmart Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Croma Showerpipe 220 EcoSmart Instructions for use/assembly instructions

Signature Hardware BEASLEY 948322 manual

Signature Hardware

Signature Hardware BEASLEY 948322 manual

Sanela SLU 32P Mounting instructions

Sanela

Sanela SLU 32P Mounting instructions

Elkay Pacemaker PSLVR1917 Specifications

Elkay

Elkay Pacemaker PSLVR1917 Specifications

Glacier bay HD67543W-6001 Installation and care guide

Glacier bay

Glacier bay HD67543W-6001 Installation and care guide

Haws 1109FR Installation, operation & maintenance instructions

Haws

Haws 1109FR Installation, operation & maintenance instructions

Karibu 80460 Building instructions

Karibu

Karibu 80460 Building instructions

Restoration Hardware EATON THERMO SHOWER KIT installation instructions

Restoration Hardware

Restoration Hardware EATON THERMO SHOWER KIT installation instructions

Moen L2368EP installation guide

Moen

Moen L2368EP installation guide

Toto TCW07 Installation

Toto

Toto TCW07 Installation

Hans Grohe Ecostat Select 13141000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Ecostat Select 13141000 Instructions for use/assembly instructions

American Standard Generations 24" Washstand 9210.224.329 Assembly and installation instructions

American Standard

American Standard Generations 24" Washstand 9210.224.329 Assembly and installation instructions

THG PARIS G00.219D installation instructions

THG PARIS

THG PARIS G00.219D installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.