Specifications
Maximum Static Pressure: 10.0 bar
Inlet Water Temperature
Min: 0.2 bar Max: 5.0 bar
Dynamic Water Pressure
5°C
25°C
Cold Water Supply
Min: 5°C Max: 25°C 65°C Recommended
Tools You’ll Need
Hot Water Supply
Pack Contents
65°C
150
Centres
15mm
Compression
Inlet Connections
Inlet Dimensions
Cavity Dimensions (mm)
Minimum Fitting Depth: 60mm
Maximum Fitting Depth: 75mm
Concealing Plate Adjustment
Range: 15mm 60
15
IMPORTANT
The inlet hot water must
be at least 10°C above the
required blend temperature.
Decrease
Temperature
Increase
Temperature
Draw around
the concealing
plate as a template,
measuring in by
10mm to give
clearance. Finish the
wall surface. Using a
silicon sealant, push
on the concealing
plate and hold
firmly until set.
x1
x1
x1
x2
x2
x2
x2
x1
x1
Flat head
Screwdriver Silicon Sealant Hexagonal KeysPipe CutterDrill Adjustable Spanner
Hot
Cold
5
4
2
Connect the inlet
pipes ensuring the
olives are fitted.
Screw the shrouds
onto the valve.
Pipe & Wire Detector
6
Elbows can
be pointed up
or down
Fit the handles.
7
2.5
mm
3
1
2.5
mm
2.5
mm
Pre-set to
42°C
2
Socket Spanner
Temperature Adjustment
REMEMBER
To service
your
product!
Turn the spindle
to increase or
decrease the
temperature.
Check the
temperature and
adjust until you
achieve the
desired result.
Turn the handle to the
maximum temperature
setting, then remove it.
Fit the
temperature
handle back in
the maximum
hot position.
Plumb the valve into
your chosen outlet.
Turn on the water
supply and check the
valve for any leaks.
3
2
Green Flow
Limiter (Cold)
1
Valve Configuration
Remove the inlet elbows and filters.
Remove the plastic inserts from the valve
inlets and insert the flow regulators.
Replace the elbows, ensuring the
filters are fitted.
IMPORTANT
If installed in
conjunction with
combination
boiler flow
regulators
must be
fitted.
Yellow Flow
Limiter (Hot)
Installation
REMEMBER
hot on the left,
cold on the
right
1
Prepare the pipework.
Create the rear access point in
the back of the wall cavity.
Secure the valve using
the screws supplied
(solid walls only) or
a suitable alternative.
IMPORTANT
Rear access to the
shower is required
for maintenance
and servicing
Install suitable
batons (if required)
into the cavity.
Take the finished
wall surface into
consideration when
fitting the valve
into the cavity.
Mark the position
of the valve; drill
and plug holes
to suit.
Cavity Space
60mm
75mm
Baton
Rear
Access
Point
Installation Instructions
& User Guide
Prior to Installation
Please leave these instructions
with the end user
All products manufactured and supplied by Bristan are safe to use
provided that they are installed, operated and receive regular
maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999
and current by-laws. For full Installation Requirements & Notes (IRN)
please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease
of future maintenance. Before installing this product the water supply
must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/
servicing purposes.
Before drilling into walls, check that there are no hidden electrical
wires, cables or water supply pipes. This can be checked with the
aid of an electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
This product must not be modified in any way
as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water
Authority or the Secretary of the Institute of Plumbing,
address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Product Code: HOU SHCDIV C (D7)
Increase
Temperature
Decrease
Temperature
Gently
remove the
concealing
plate from
the wall.
IMPORTANT
Isolate the
water supply
before
starting!
1
46
2
5
3
Maintenance - Cartridge Cleaning
Reverse the installation steps,
ensuring the temperature
stop is aligned correctly.
12
3
Remove the
handles.
Unscrew the shrouds.
Remove the cartridges
and piston.
2.5
mm
23
mm
Remove any O-rings and soak all
components in de-scaler and wash o
in clean water. Examine all seals and
replace if needed. Use WRAS
approved silicon based grease
on all seals.
Follow the
Temperature
Adjustment Steps
if required.
Left
Outlet On
O
Right
Outlet On
Increased
Temperature
Decreased
Temperature
General Cleaning Operation
Bristan products are made from premium materials, with
hand polished, PVD, EPD or electroplated finishes.
Your shower should be regularly cleaned with warm water,
a mild pH-neutral liquid soap and polished with a soft cloth.
Any residues from soap, toothpaste, shampoos and shower
gels can cause blemishes if not rinsed o straight after use,
Household bleaches and cleaners contain harsh chemicals
and may damage the surface finish. Avoid using abrasive
cloths, scouring pads, scrub sponges, steel wool or anything
similar.
Choose the location for the wall outlet
and create a 25-30mm hole in the wall.
Ensure your shower accessories have
enough reach from that position.
Finish the wall surface.
To reduce the build up of lime scale and to
ensure this shower works to its maximum
performance we recommend this shower
is serviced every 6-12 months depending
on the hardness of your water.
Servicing Intervals
Wall Outlet Installation
Fit the wall outlet,
ensuring the
washers are fitted
either side of
the wall.
Go to Step 6 in the
Installation Steps.
With rear access
Without rear access
Screw the wall outlet into
the 1/2” female connection,
using a suitable thread sealant
ensuring the rubber seal is fitted
to the back of the wall outlet.
Follow Step 6 in the
Installation Steps, fitting a 1/2”
female connection at the hole in
the wall (not supplied).
Troubleshooting
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer
solid guarantees on all our products, eective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273
where our expert team of advisors will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
Our Guarantee
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquir[email protected]
A Masco Company
Symptom Cause Remedy
No flow or
low flow rate
Partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on and o
as flow rate or pressure is too low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.
Refer to the specification for the
minimum distance required.
Are the water supply pressures balanced? If pressures are unbalanced, a pressure reducing valve
should be used for optimum performance.
Hot or cold water being drawn o elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Do not use other water outlets when using the shower.
Airlock or partial blockage in the supply
pipework.
Flush through pipework and filters to ensure removal
of debris and any airlocks.
Hot/Cold water supply has failed Check the hot and cold feeds. The shower will not
work if either fails.
Maximum
Water
Temperature
too Hot/Cold
Maximum Water Temperature
needs adjusting.
Refer to the Temperature Setting section to set your
desired maximum temperature.
Outlet Water
Temperature
too Hot/Cold
Filter/pipe blockage Flush through pipework and filters to ensure
removal of debris and any airlocks.
Installtion conditions outside
operating parameters.
Refer to the specification for the
minimum distance required.
Hot water temperature is less than 10°C
above the required blend temperature
Adjust hot water temperature or wait for water to
reheat if a stored water system is used.
Instantaneous water not igniting because the
water flow rate is too low.
Increase water flow rate through the system. Refer to the
Maintenance section to clean/check the cartridge and filters
for any damage. Contact your boiler manufacturer.
Instantaneous water not igniting because the
water pressure is too low.
Refer to the specification for system requirements.
Increase water pressure through the system.
Contact your boiler manufacturer.
Only hot/
cold water
from Shower
Valve
Inlet water supplies are reversed.
Check the water inlet connections are the correct way
around: Hot on the left, Cold on the right when viewed from
the front. Rework pipework as necessary.
Filter/pipe blockage Flush through pipework and filters to ensure removal of
debris and any airlocks.
Water
dripping
from shower
This is normal for a short time after using the
shower.
This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip,
possibly due to the cartridge
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Shower does
not turn on
Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l., 14 Rue Strachen
6933 Mensdorf, Luxembourg.

Other Bristan Plumbing Product manuals

Bristan W BASIN14 C Wiring diagram

Bristan

Bristan W BASIN14 C Wiring diagram

Bristan Regency R BSM C User manual

Bristan

Bristan Regency R BSM C User manual

Bristan AR3 SHCDIV C Wiring diagram

Bristan

Bristan AR3 SHCDIV C Wiring diagram

Bristan HOU BSM C Wiring diagram

Bristan

Bristan HOU BSM C Wiring diagram

Bristan Cinnamon Wiring diagram

Bristan

Bristan Cinnamon Wiring diagram

Bristan W BATH05 C Wiring diagram

Bristan

Bristan W BATH05 C Wiring diagram

Bristan EV KIT-EFB C Mounting instructions

Bristan

Bristan EV KIT-EFB C Mounting instructions

Bristan Jute JU BASNW C User manual

Bristan

Bristan Jute JU BASNW C User manual

Bristan Vantage VTX 1/2 C User manual

Bristan

Bristan Vantage VTX 1/2 C User manual

Bristan JAVA J BSM E8 C User manual

Bristan

Bristan JAVA J BSM E8 C User manual

Bristan 1901 User manual

Bristan

Bristan 1901 User manual

Bristan Z2 TBV 1/2 C Wiring diagram

Bristan

Bristan Z2 TBV 1/2 C Wiring diagram

Bristan BRG 3HBAS C User manual

Bristan

Bristan BRG 3HBAS C User manual

Bristan W BASIN06 C User manual

Bristan

Bristan W BASIN06 C User manual

Bristan Opac Series Mounting instructions

Bristan

Bristan Opac Series Mounting instructions

Bristan Star FH STRD01 C User manual

Bristan

Bristan Star FH STRD01 C User manual

Bristan KN2 SHXAR C Mounting instructions

Bristan

Bristan KN2 SHXAR C Mounting instructions

Bristan Joy ThermoSafe Series Mounting instructions

Bristan

Bristan Joy ThermoSafe Series Mounting instructions

Bristan NIVA NVA BSM C Wiring diagram

Bristan

Bristan NIVA NVA BSM C Wiring diagram

Bristan Z TC 1/2 C User manual

Bristan

Bristan Z TC 1/2 C User manual

Bristan Zing Safe Touch Bar Mixer Multi Mode Kit Wiring diagram

Bristan

Bristan Zing Safe Touch Bar Mixer Multi Mode Kit Wiring diagram

Bristan W BASIN01 C Wiring diagram

Bristan

Bristan W BASIN01 C Wiring diagram

Bristan CR SHXDIVFF C Wiring diagram

Bristan

Bristan CR SHXDIVFF C Wiring diagram

Bristan Cadet Wiring diagram

Bristan

Bristan Cadet Wiring diagram

Popular Plumbing Product manuals by other brands

Hans Grohe Vivenis 90 75033 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Vivenis 90 75033 Series Instructions for use/assembly instructions

Grohe Atrio 20 000 installation instructions

Grohe

Grohe Atrio 20 000 installation instructions

Symmons Duro 361TS Operation & maintenance manual

Symmons

Symmons Duro 361TS Operation & maintenance manual

Glacier bay PAULINA Installation and care guide

Glacier bay

Glacier bay PAULINA Installation and care guide

CANTERBURY AGORA Z2314-45IN manual

CANTERBURY

CANTERBURY AGORA Z2314-45IN manual

Sanela SLKN 03 quick start guide

Sanela

Sanela SLKN 03 quick start guide

Watermark Brut 64 Series manual

Watermark

Watermark Brut 64 Series manual

Heritage Bathrooms Glastonbury TGRC00 Installation instructions and user guide

Heritage Bathrooms

Heritage Bathrooms Glastonbury TGRC00 Installation instructions and user guide

KWC SIRIUS SIRW759 Installation and operating instructions

KWC

KWC SIRIUS SIRW759 Installation and operating instructions

Allen + Roth LWSJ60VBR Assembly instructions

Allen + Roth

Allen + Roth LWSJ60VBR Assembly instructions

Spectrum Brands Pfister Artezia LF-049-AE Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Artezia LF-049-AE Quick installation guide

Kessel Linearis Comfort installation instructions

Kessel

Kessel Linearis Comfort installation instructions

Axor Brushed Nickel 10313821 Specification sheet

Axor

Axor Brushed Nickel 10313821 Specification sheet

fine fixtures SDF2 installation manual

fine fixtures

fine fixtures SDF2 installation manual

Hans Grohe iBox universal 01800180 Assembly instructions

Hans Grohe

Hans Grohe iBox universal 01800180 Assembly instructions

Omnires Cascade CA4044 Installation and Maintenance

Omnires

Omnires Cascade CA4044 Installation and Maintenance

ProFlo PF418A installation instructions

ProFlo

ProFlo PF418A installation instructions

American Standard 2474 Product user manual

American Standard

American Standard 2474 Product user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.