manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bristan
  6. •
  7. Plumbing Product
  8. •
  9. Bristan DSC SHC3DIV C Wiring diagram

Bristan DSC SHC3DIV C Wiring diagram

Pressure
BAR
1.0
5.0
4.0
2.0 3.0
0.
Pressure
BAR
1.0
5.0
4.0
2.0 3.0
0.
Specifications
Maximum Static Pressure: 10.0 bar
Inlet Water Temperature
Min: 0.2 bar Max: 5.0 bar
Dynamic Water Pressure
5°C
25°C
Cold Water Supply
Min: 5°C Max: 25°C 65°C Recommended
Tools You’ll Need
Hot Water Supply
Pack Contents
65°C
150
Centres
15mm
Compression
Inlet Connections
Inlet Dimensions
IMPORTANT
The inlet hot water must
be at least 10°C above the
required blend temperature.
Cavity Depth: 35mm
Concealing Plate
Adjustment Range: 30mm
Cavity Dimensions (mm)
35
30 45
120
x3
x3
x4
x1
x2
x1
x1
Flat head
Screwdriver Silicon Sealant Hexagonal KeysPipe CutterDrill Adjustable Spanner
Hot Cold
4
3
2
Secure the
valve using
the screws
supplied
(solid walls
only) or a
suitable
alternative.
Connect the inlet
pipes ensuring the
olives are fitted.
Screw the
shrouds
onto the
valve.
Pipe & Wire Detector
Plumb the
valve into
your chosen
outlets.
Elbows can
be pointed up
or down
Fit the handles.
6
2
2.5
mm
Turn the
temperature stop
to increase or
decrease the
temperature.
Check the
temperature and
adjust until you
achieve the
desired result.
Increase
Temperature
Decrease
Temperature
Pre-set to
42°C
Finish the
wall surface,
ensuring there
is at least a 10mm
gap between the
cavity and the edge
of the face plate.
Using a silicon
sealant, push on the
concealing plate and
hold firmly until set.
5
Socket Spanner
3
1
2.5
mm
Fit the temperature
handle back in the
maximum hot position.
2.5
mm
Turn the handle to the
maximum temperature
setting, then remove it.
Temperature Adjustment
REMEMBER
To service
your
product!
x3
2
Green Flow
Limiter (Cold)
1
Valve Configuration
Remove the inlet elbows and filters.
Remove the plastic inserts from the valve
inlets and insert the flow regulators.
Replace the elbows, ensuring the
filters are fitted.
IMPORTANT
If installed in
conjunction with
combination
boiler flow
regulators
must be
fitted.
Yellow Flow
Limiter (Hot)
1
Installation
REMEMBER
hot on the left,
cold on the
right
Min 35mm
Max 45mm
Batons
Install suitable
batons
(if required) onto
the rear cavity.
Mark the position
of the valve
and drill and plug
holes to suit.
Installation Instructions
& User Guide
Prior to Installation
Please leave these instructions
with the end user
All products manufactured and supplied by Bristan are safe to use
provided that they are installed, operated and receive regular
maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999
and current by-laws. For full Installation Requirements & Notes (IRN)
please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease
of future maintenance. Before installing this product the water supply
must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/
servicing purposes.
Before drilling into walls, check that there are no hidden electrical
wires, cables or water supply pipes. This can be checked with the
aid of an electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
This product must not be modified in any way
as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water
Authority or the Secretary of the Institute of Plumbing,
address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Product Code: DSC SHC3DIV C (D6)
Decrease
Temperature
Increase
Temperature
Unscrew the
shrouds.
Remove the
cartridges
and piston.
123
Maintenance - Cartridge Cleaning
IMPORTANT
Isolate the
water supply
before
starting!
2.5
mm
46
5
Remove any O-rings and soak all
components in de-scaler and wash o
in clean water. Examine all seals and
replace if needed. Use WRAS
approved silicon based grease
on all seals.
Reverse the installation steps,
ensuring the temperature
stop is aligned correctly.
12
3
Gently
remove the
concealing
plate from
the wall.
24
mm
Follow the Temperature
Adjustment Steps if required.
Remove
handles.
General Cleaning Operation
Bristan products are made from premium materials, with
hand polishing and electroplated finishes.
Your taps or shower should be regularly cleaned with warm
water, a mild pH-neutral liquid soap, and polished with a soft
cloth. Any residues from soap, toiletries etc. should be rinsed
o straight after use.
Household bleaches and cleaners contain harsh chemicals and
may damage the surface finish. Avoid using abrasive cloths,
scouring pads, scrub sponges, steel wool or anything similar.
Some surfaces such as nickel and pewter may be aected by
the dye found in some cloths, so it is also important to avoid
hanging cloths on spouts.
On/More
Flow Bottom
Outlet
O/Less
Flow
Left Outlet
On/More Flow
O
Right Outlet
On/More
Flow
Increased
Temperature Decreased
Temperature
Choose the location for the wall outlet
and create a 25-30mm hole in the wall.
Ensure your shower accessories have
enough reach from that position.
Finish the wall surface.
To reduce the build up of lime scale
and to ensure this shower works
to its maximum performance we
recommend this shower is serviced
every 6-12 months depending on
the hardness of your water.
Servicing Intervals
Wall Outlet Installation
Fit the wall outlet,
ensuring the
washers are fitted
either side of
the wall.
Go to Step 6 in the
Installation Steps.
With rear access
Without rear access
Screw the wall outlet into
the 1/2” female connection,
using a suitable thread sealant
ensuring the rubber seal is fitted
to the back of the wall outlet.
Follow Step 6 in the
Installation Steps, fitting a 1/2”
female connection at the hole in
the wall (not supplied).
Troubleshooting
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer
solid guarantees on all our products, eective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273
where our expert team of advisors will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
Our Guarantee
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquir[email protected]
A Masco Company
Symptom Cause Remedy
No flow or
low flow rate
Partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on and o
as flow rate or pressure is too low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.
Refer to the specification for the
minimum distance required.
Are the water supply pressures balanced? If pressures are unbalanced, a pressure reducing valve
should be used for optimum performance.
Hot or cold water being drawn o elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Do not use other water outlets when using the shower.
Airlock or partial blockage in the supply
pipework.
Flush through pipework and filters to ensure removal
of debris and any airlocks.
Hot/Cold water supply has failed Check the hot and cold feeds. The shower will not
work if either fails.
Maximum
Water
Temperature
too Hot/Cold
Maximum Water Temperature
needs adjusting.
Refer to the Temperature Setting section to set your
desired maximum temperature.
Outlet Water
Temperature
too Hot/Cold
Filter/pipe blockage Flush through pipework and filters to ensure
removal of debris and any airlocks.
Installtion conditions outside
operating parameters.
Refer to the specification for the
minimum distance required.
Hot water temperature is less than 10°C
above the required blend temperature
Adjust hot water temperature or wait for water to
reheat if a stored water system is used.
Instantaneous water not igniting because the
water flow rate is too low.
Increase water flow rate through the system. Refer to the
Maintenance section to clean/check the cartridge and filters
for any damage. Contact your boiler manufacturer.
Instantaneous water not igniting because the
water pressure is too low.
Refer to the specification for system requirements.
Increase water pressure through the system.
Contact your boiler manufacturer.
Only hot/
cold water
from Shower
Valve
Inlet water supplies are reversed.
Check the water inlet connections are the correct way
around: Hot on the left, Cold on the right when viewed from
the front. Rework pipework as necessary.
Filter/pipe blockage Flush through pipework and filters to ensure removal of
debris and any airlocks.
Water
dripping
from shower
This is normal for a short time after using the
shower.
This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip,
possibly due to the cartridge
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Shower does
not turn on
Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l., 14 Rue Strachen
6933 Mensdorf, Luxembourg.

This manual suits for next models

1

Other Bristan Plumbing Product manuals

Bristan Descent DSC BAS C Mounting instructions

Bristan

Bristan Descent DSC BAS C Mounting instructions

Bristan N2 SHCDIV G (D7) Wiring diagram

Bristan

Bristan N2 SHCDIV G (D7) Wiring diagram

Bristan Java J BID C User manual

Bristan

Bristan Java J BID C User manual

Bristan CR SHXDIVFF C Wiring diagram

Bristan

Bristan CR SHXDIVFF C Wiring diagram

Bristan GLD2 BSM C Wiring diagram

Bristan

Bristan GLD2 BSM C Wiring diagram

Bristan PIV BSM C User manual

Bristan

Bristan PIV BSM C User manual

Bristan ARM WORD01 C User manual

Bristan

Bristan ARM WORD01 C User manual

Bristan PM2 SHCDIV C Wiring diagram

Bristan

Bristan PM2 SHCDIV C Wiring diagram

Bristan RV SNK C User manual

Bristan

Bristan RV SNK C User manual

Bristan DUL3 THBSM C User manual

Bristan

Bristan DUL3 THBSM C User manual

Bristan GLL FLEXSNK C (D1) Wiring diagram

Bristan

Bristan GLL FLEXSNK C (D1) Wiring diagram

Bristan Value VAL BSM C CD Wiring diagram

Bristan

Bristan Value VAL BSM C CD Wiring diagram

Bristan Z2 SQR 1/2 C Wiring diagram

Bristan

Bristan Z2 SQR 1/2 C Wiring diagram

Bristan SAF SHCDIV BLK (D1) Wiring diagram

Bristan

Bristan SAF SHCDIV BLK (D1) Wiring diagram

Bristan PM2 SHCDIV C Wiring diagram

Bristan

Bristan PM2 SHCDIV C Wiring diagram

Bristan HOU 1HBF C Wiring diagram

Bristan

Bristan HOU 1HBF C Wiring diagram

Bristan HY POWSHX W Mounting instructions

Bristan

Bristan HY POWSHX W Mounting instructions

Bristan Buzz Wiring diagram

Bristan

Bristan Buzz Wiring diagram

Bristan JU BAS C User manual

Bristan

Bristan JU BAS C User manual

Bristan W BTH12 C User manual

Bristan

Bristan W BTH12 C User manual

Bristan EXD BAS C User manual

Bristan

Bristan EXD BAS C User manual

Bristan FHC CTRD01 C User manual

Bristan

Bristan FHC CTRD01 C User manual

Bristan AR3 SHCDIV C Wiring diagram

Bristan

Bristan AR3 SHCDIV C Wiring diagram

Bristan VR1000 User manual

Bristan

Bristan VR1000 User manual

Popular Plumbing Product manuals by other brands

Signature Hardware LETHE 926768 installation instructions

Signature Hardware

Signature Hardware LETHE 926768 installation instructions

Sweatspa Capsule User's manual guide

Sweatspa

Sweatspa Capsule User's manual guide

Hans Grohe Starck 28 530 Series installation instructions

Hans Grohe

Hans Grohe Starck 28 530 Series installation instructions

Gessi 30651 manual

Gessi

Gessi 30651 manual

Elkay Lustertone LR2522 Specifications

Elkay

Elkay Lustertone LR2522 Specifications

Sanela SLU 93NB Instructions for use

Sanela

Sanela SLU 93NB Instructions for use

Omnires Y1233GL Installation and Maintenance

Omnires

Omnires Y1233GL Installation and Maintenance

Hans Grohe Talis M52 220 2jet 73863 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Talis M52 220 2jet 73863 Series Instructions for use/assembly instructions

Hans Grohe Talis Select M51 220 1jet 72822 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Talis Select M51 220 1jet 72822 Series Instructions for use/assembly instructions

Sonnenkonig BARRIQUE SOIN & FOUR manual

Sonnenkonig

Sonnenkonig BARRIQUE SOIN & FOUR manual

Gessi 54011 manual

Gessi

Gessi 54011 manual

Hans Grohe Metris C 15753 1 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe Metris C 15753 1 Series Installation/User Instructions/Warranty

Hans Grohe Talis M54 210 2jet 72800 3 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Talis M54 210 2jet 72800 3 Series Instructions for use/assembly instructions

Villeroy & Boch Butler Double Sink 6323 installation instructions

Villeroy & Boch

Villeroy & Boch Butler Double Sink 6323 installation instructions

Moen TS340 Series Specifications

Moen

Moen TS340 Series Specifications

ProFlo PFWSCM1M313 installation instructions

ProFlo

ProFlo PFWSCM1M313 installation instructions

Kohler K-10086 Installation and care guide

Kohler

Kohler K-10086 Installation and care guide

Kohler K-7397 installation guide

Kohler

Kohler K-7397 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.