Other Broan Fan manuals

Broan B110H65RT Use and care manual

Broan

Broan B110H65RT Use and care manual

Broan HUMIDITY SENSING FAN QTRE100S User manual

Broan

Broan HUMIDITY SENSING FAN QTRE100S User manual

Broan QTR080L User manual

Broan

Broan QTR080L User manual

Broan QTXE110S User manual

Broan

Broan QTXE110S User manual

Broan LOSONE SELECT L100 User manual

Broan

Broan LOSONE SELECT L100 User manual

Broan 682 User manual

Broan

Broan 682 User manual

Broan QTRE100H User manual

Broan

Broan QTRE100H User manual

Broan 512M User manual

Broan

Broan 512M User manual

Broan ZB110ML User manual

Broan

Broan ZB110ML User manual

Broan 670 User manual

Broan

Broan 670 User manual

Broan ULTRA SILENT QTHB1 User manual

Broan

Broan ULTRA SILENT QTHB1 User manual

Broan MP100 User manual

Broan

Broan MP100 User manual

Broan 508 User manual

Broan

Broan 508 User manual

Broan QT140LE User manual

Broan

Broan QT140LE User manual

Broan SOLITAIRE Series User manual

Broan

Broan SOLITAIRE Series User manual

Broan 100HL User manual

Broan

Broan 100HL User manual

Broan ZB110HL User manual

Broan

Broan ZB110HL User manual

Broan NuTone EZ80N User manual

Broan

Broan NuTone EZ80N User manual

Broan 345SOBK User manual

Broan

Broan 345SOBK User manual

Broan QTR140L User manual

Broan

Broan QTR140L User manual

Broan P402 Series User manual

Broan

Broan P402 Series User manual

Broan qt90e User manual

Broan

Broan qt90e User manual

Broan LP50100DC User manual

Broan

Broan LP50100DC User manual

Broan 506 User manual

Broan

Broan 506 User manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Page 1
MODEL QTR100
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
SWCNKſGFRGTUQPUKPCEEQTFCPEGYKVJCNNCRRNKECDNGEQFGU
CPFUVCPFCTFUKPENWFKPIſTGTCVGFEQPUVTWEVKQPEQFGUCPF
standards.
5WHſEKGPVCKTKUPGGFGFHQTRTQRGTEQODWUVKQPCPFGZJCWUVKPI
QHICUGUVJTQWIJVJGƀWGEJKOPG[QHHWGNDWTPKPIGSWKR-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
RWDNKUJGFD[VJG0CVKQPCN(KTG2TQVGEVKQP#UUQEKCVKQP0(2#
and the American Society for Heating, Refrigeration and Air
%QPFKVKQPKPI'PIKPGGTU#5*4#'CPFVJGNQECNEQFGCWVJQTK-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
C)(%+)TQWPF(CWNV%KTEWKV+PVGTTWRVGTRTQVGEVGFDTCPEJ
EKTEWKVEGKNKPIKPUVCNNCVKQPQPN[
8. This unit must be grounded.
CAUTION
!
(QTIGPGTCNXGPVKNCVKPIWUGQPN[&QPQVWUGVQGZJCWUVJC\CTF-
QWUQTGZRNQUKXGOCVGTKCNUCPFXCRQTU
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
2NGCUGTGCFURGEKſECVKQPNCDGNQPRTQFWEVHQTHWTVJGTKPHQTOC-
tion and requirements.
MODEL QTR100
VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
WARRANTY
BROAN THREE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for
a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
56#46'45#0&67$'56JKUYCTTCPV[FQGUPQVEQXGTCPQTOCNOCKP-
VGPCPEGCPFUGTXKEGQTDCP[RTQFWEVUQTRCTVUYJKEJJCXGDGGPUWDLGEV
VQOKUWUGPGINKIGPEGCEEKFGPVKORTQRGTOCKPVGPCPEGQTTGRCKTQVJGT
VJCPD[$TQCPHCWNV[KPUVCNNCVKQPQTKPUVCNNCVKQPEQPVTCT[VQTGEQOOGPFGF
installation instructions.
The duration of an implied warranty is limited to the three-year period as
URGEKſGFHQTVJGGZRTGUUYCTTCPV[5QOGUVCVGUFQPQVCNNQYNKOKVCVKQP
on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OP-
TION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI-
DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
UVCVGUFQPQVCNNQYVJGGZENWUKQPQTNKOKVCVKQPQHKPEKFGPVCNQTEQPUGSWGPVKCN
damages, so the above limitation may not apply to you.
6JKUYCTTCPV[IKXGU[QWURGEKſENGICNTKIJVUCPF[QWOC[CNUQJCXGQVJGT
rights, which vary from state to state. This warranty supersedes all prior
warranties.
6QSWCNKH[HQTYCTTCPV[UGTXKEG[QWOWUVCPQVKH[$TQCPCVVJGCFFTGUU
QTVGNGRJQPGPWODGTUVCVGFDGNQYDIKXGVJGOQFGNPWODGTCPFRCTV
KFGPVKſECVKQPCPFEFGUETKDGVJGPCVWTGQHCP[FGHGEVKPVJGRTQFWEVQT
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027

Installer: Leave this manual with the homeowner.
(QTSWKGVCPFGHſEKGPVQRGTCVKQPNQPINKHGCPFCVVTCEVKXGCRRGCT-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
OQVQTDGCTKPIUCTGOCMKPIGZEGUUKXGQTWPWUWCNPQKUGUTGRNCEG
VJGOQVQTYKVJVJGGZCEVUGTXKEGOQVQT6JGKORGNNGTUJQWNFCNUQ
be replaced.
OPERATION
Use an on/off switch or speed control to operate this ventilator.
See “Connect Wiring” for details.
Page 2
MODEL QTR100
TYPICAL INSTALLATIONS
Housing mounted to I-joists.
Use I-joist spacer block (provided).
Housing mounted to joists.
Housing mounted to truss.
PLAN THE INSTALLATION
ROOF CAP *
4-IN. ROUND
ELBOW *
4-IN. ROUND
DUCT *
WALL
CAP *
*Purchase
separately
6JGWPKVYKNNQRGTCVGOQUVSWKGVN[CPFGHſEKGPVN[YJGPNQECVGF
where the shortest possible duct run and minimum number of
elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce
backdrafts.
Plan to supply the unit with proper line voltage and appropriate
power cable.
Cooking
Equipment
Floor
Do not install above or
inside this area.
45
o
45
o
Page 3
MODEL QTR100
5. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.
CONNECT WIRING
3. Attach
damper/duct
connector.
Snap damper /
duct connector
onto housing.
Make sure con-
PGEVQTKUƀWUJYKVJ
top of housing and
FCORGTƀCRHCNNU
closed.
4. Install 4-
inch round
ductwork.
Connect 4-inch
round ductwork
to damper / duct
connector. Run
ductwork to a
roof cap or wall
cap. Tape all
ductwork con-
nections to make
them secure and air tight.
INSTALL HOUSING & DUCT
1. Bend
housing
tabs.
Use a pliers to
bend housing
TABS out to 900.
2. Mount
housing to
joist.
Hold housing
in place so that
the housing
tabs contact the
bottom of the
LQKUV6JGJQWU-
ing mounts with
HQWTUETGYU
or nails. Screw or
PCKNJQWUKPIVQLQKUVVJTQWIJNQYGUVJQNGUKPGCEJOQWPV-
KPIƀCPIGVJGPVJTQWIJJKIJGUVJQNGU016'/QWPVKPI
to I-JOISTUJQYPTGSWKTGUWUGQHSPACERSKPENWFGF
DGVYGGPVJGJKIJGUVJQNGQHGCEJOQWPVKPIƀCPIGCPFVJG
+LQKUV
SPACER
WUGHQTOQWPVKPIVQ+,QKUV
I-JOIST
TABS
Page 4
MODEL QTR100
3
4
1
5
6
7
8
9
11
10
4
2
12
13
14
14
SERVICE PARTS
99043989A
Key No. Part No. Description
1 97016466 Housing
2 97016449 Duct Connector-4”
3 98010102 Wiring Plate
   5ETGY:TGSŏF
5 97016932 Wire Panel/Harness Assembly
6 99020284 Blower Wheel
7 99080582 Motor
   +UQNCVQTTGSŏF
9 97016468 Motor Plate
   9CUJGTTGSŏF
   0WV*GZ.QEMTGSŏF
* 97016622 Blower Assembly
    KPENWFGUMG[PQUVJTW
12 97017418 Grille Assembly
    KPENWFGUMG[PQ
   )TKNNG5RTKPITGSŏF
   5RCEGTUWRRNKGF
INSTALL GRILLE
7. Attach grille
to housing.
 5SWGG\GITKNNG
springs and insert
them into slots on
each side of hous-
ing.
8. Push grille
against ceil-
ing.
6. Finish ceiling.
Install ceiling material. Cut out around housing.
SERVICE NOTE
6QTGOQXG$NQYGT#UUGODN[
7PRNWIOQVQT
4GOQXGUETGYHTQOOQ-
VQTRNCVGƀCPIG
Find the single TAB on the
OQVQTRNCVGNQECVGFPGZVVQ
VJGTGEGRVCENG
Push up near motor plate
tab while pushing out on
side of housing. Or insert a
straight-blade screwdriver
KPVQUNQVKPJQWUKPIPGZVVQ
VCDCPF
twist screwdriver.
TAB
Order service parts by “Part No.” - not by “Key No.”