BURG WATCHER TSE 5013 E-KEY User manual

www.burg-waechter.de
BURG-WÄCHTER KG
Altenhofer Weg 15
58300 Wetter
Germany
Elektronisches Türschloss
BUSINESS
Ingeniously safe.
Ingeniously simple.
SET 5013 E-KEYSET 5011 PINCODE SET 5012 FINGERSCAN
BA/MA TSE Set 5000 dp/fsc 04/2012
Installation and
User Manual

TSE BUSINESS 5000 English |2
Image
On/Enter button
Activation of the keypad for entry of an opening code or
selection of a menu item.
Function button
The function button provides for a variety of actions depending on
the actual status of the keypad. The display indicates, which function
is active.
1) Entry into the menu for programming
When the “Func:M” symbol is displayed, the menu can be
reached by pressing the “Function” button. In the menu,
the buttons “1” and “2” can be used as a scroll function to
navigate through its structure.
2) Deleting an entry action
When the “Func:C” symbol is displayed, the last entry can be
cancelled by pressing the “Function” button.
3) Entry into the previous programming level/Back
When you are in the menu, the symbol
“Func:<” is displayed. By pressing the “Function” button, you
return into the menu structure on the next higher level.
Battery indicator
Battery full Battery empty
The display indicates the battery statuses of the cylinder unit and
the keypad unit. The indication on the display concerns the batteries
with the lowest status. In case a battery is empty, the display
indicates as follows:
Replace the battery in keypad or replace the battery in the button.
When the battery has been replaced and then the opening code
entered twice, the actually lowest battery status is displayed. When
only a single battery set is replaced, the display can still indicate an
“incomplete” status, despite the replacement. In case you do not
replace the batteries in spite of the replacement indication, you will
have to enter the valid opening code once more in order to open the
door. At the same time, the LED of the inner knob flashes 5 x 5 times.
You can still open the door in this way approx. 50 times. Then it can
only be opened using the administrator code. Now the batteries must
be replaced, otherwise the door cannot be opened any more.
Light sensor
The light sensor reacts on differing lighting conditions, based on
which the brightness of the display and the illumination of the
keys are adjusted. If the lighting of the environment is sufficient,
the illumination of the keys is completely deactivated.
Fingerscan sensor
To open or register the particular finger.
Structure Dear customer,
Thank you very much for your decision for the TSE Series 5000 electronic
locking system by BURG-WACHTER. This system has been developed
and manufactured using the latest technical potential and satisfies high
security requirements. The electronic cylinder can be used easily without
any drilling and installation of cables in any door prepared for profile
cylinder up to a door thickness of 120 mm (60/60, measured at the central
detent bolt). The electronic cylinder is perfectly suitable for both new
installations and upgrading.
Besides this, you have diverse additional options, i.e. on which ident
medium shall be used. You can find out more on the following pages.
Remove the batteryprotection strip from the inner knob in order
to energize the cylinder.
Please press the ON/Enter button during the 1st activation for
approx. 10 seconds in order to make the keypad ready for operation.
Attention: Just a light pressure by your finger is required to operate
the keypad, similarly to modern high quality touchscreen phones!
Important: Please read the entire User Manual before you
start programming.
We hope you enjoy your new locking system.
TSE Keypad FS

TSE BUSINESS 5000 English |3
Administrator code
– Factory se to 1-2-3-4-5-6 (please be sure to change)
Power supply
– 6 x MIGNON LR6 AA ALKALINE
Optical signalling
The optical signal in form of a LED is incorporated in the knob on
the inner side of the door. This LED informs you on the following:
– 1 x brief: lock has been opened
– 2 x brief: lock has been shut
– every 5 sec. 1 × brief: permanent opening activated
– 1 × brief, 1 × long, 2 sec. pause, repetition:
lock in programming mode
– 5 × brief, 2 sec. pause, repetition after 20 sec.:
cylinder battery empty
TSE Set 5011 PINCODE
The electronic cylinder operates using a 6-digit numeric code.
Optionally, the TSE 5103 E-KEY remote key can as well be used.
TSE 5011 PINCODE functions (standard)
– Total number of users: up to 48
– Also an E-KEY can be assigned to each pin code user
(except for administrator).
Optional locking media
– TSE 5103 E-KEY remote key
Additional functions available using the optional
TSE Software, for example:
– User administration
– Time and calendar functions
– Assignment of authorizations
– History functions
Technical data
Blocking times After 3 × wrong code is entered 1 minute, then
always 3 minutes
Display Adjustable to 12 languages
Power supply for
keypad
4 x MIGNON LR6 AA ALKALINE
Power supply for
cylinder
2 x MIGNON LR6 AA ALKALINE
Permissible
ambient
conditions*
-15 °C / +50 °C / up to 95 %
rel. air humidity (noncondensing)
As a result of extreme temperature changes,
the display can react slowly or darken.
Keypad protection IP65
*In case the temperature exceeds the specified range, a corresponding
warning message is indicated on the display. Provide for appropriate
corrective action!

TSE BUSINESS 5000 English |4
TSE Set 5012 FINGERSCAN
The electronic cylinder operates using a fingerscan. In addition, the cylinder
can be operated by entering the 6-digit numeric code, or also using the
optionally delivered TSE 5103 E-KEY.
In add. to that, you can also use the 6-digit numeric code, as well as
the TSE 5103. E-Key in order to control the cylinder.
Up to 24 fingers can be programmed using the keypad. The users are
created separately (USER XXX_FP). If a code and/ or an E-KEY should
additionally be assigned to a user, it needs to be created separately.
Attention! The finger scanner must not be cleaned with detergents.
Please use a slightly moist cloth for this purpose.
TSE 5012 FINGERSCAN functions (standard)
– Total number of users: up to 48, out of which 24 can
be programmed with fingerscan
– One E-KEY can be assigned to each code user
(except administrator)
– Also a code can be assigned to every E-KEY user
Optional locking media
– TSE 5103 E-KEY
Additional functions available using the optional
TSE Software, for example:
– User administration
– Time and calendar functions
– Assignment of authorizations
– History functions
Technical data
Blocking times After 3 × wrong code is entered 1 minute, then
always 3 minutes
Display Adjustable to 12 languages
Power supply for
keypad
4 x MIGNON LR6 AA ALKALINE
Power supply for
cylinder
2 x MIGNON LR6 AA ALKALINE
Permissible
ambient
conditions*
-15 °C / +50 °C / up to 93 % rel. air humidity
(noncondensing)
Allowed temperature range: -20 °C / +50 °C
As a result of extreme temperature changes, the
display can react slowly or darken.
*In case the temperature exceeds the specified range, a corresponding
warning message is indicated on the display. Provide for appropriate
corrective action!
Attention: The TSE Keypad unit shall not be directly exposed to
outdoor environment. Precipitations and sunshine can damage
the sensor!
Administrator code
– Factory set to 1-2-3-4-5-6 (please be sure to change it)
Power supply
– 6 x MIGNON LR6 AA ALKALINE
Optical signalling
The optical signal in form of a LED is incorporated in the knob on
the inner side of the door. This LED informs you on the following:
– 1 x brief: lock has been opened
– 2 x brief: lock has been shut
– every 5 sec. 1 × brief: permanent opening activated
– 1 × brief, 1 × long, 2 sec. pause, repetition:
lock in programming mode
– 5 × brief, 2 sec. pause, repetition after 20 sec.:
cylinder battery empty

TSE BUSINESS 5000 English |5
Administrator code
The code is delivered separately on a sticker. It shall be carefully preserved.
Attention: If it is lost, any programming changes or the use of all the
administrator functions are no more possible.
Power supply for the cylinder
– 2 x MIGNON LR6 AA ALKALINE
Power supply for the E-KEY
– 1 x CR 2032
TSE Set 5013 E-KEY
The electronic cylinder operates using the E-KEY remote key. The principle
of its function is similar to that of the car locking system. The cylinder can be
controlled when the button is pressed once. The E-KEY can be subsequently
programmed by means of a keypad or of a TSE software. The radio range of
the E-KEY is up to 3 m.
TSE 5003 E-KEY functions (standard)
– Total number of users: up to 48
Optional locking media
– TSE 5103 E-KEY
– TSE 6111 Keypad PIN
– TSE 6112 Keypad FS (up to 24 fingerscans possible)
Additional functions available using the optional TSE Software,
for example:
– User administration
– Time and calendar functions
– Assignment of authorizations
– History functions
Optical signalling
OThe optical signal in the form of a LED is incorporated in the knob on the
inner side of the door. This LED informs you on the following:
– 1 x brief: lock has been opened
– 2 x brief: lock has been shut
– every 5 sec. 1 × brief: permanent opening activated
– 1 × brief, 1 × long, 2 sec. pause, repetition:
lock in programming mode
– 5 × brief, 2 sec. pause, repetition after 20 sec.:
cylinder battery empty

TSE BUSINESS 5000 English |6
Description of menu functions
The functions for the products TSE 5011 and TSE 5012 are described below.
Menu functions
Menu Code change
Changing administrator code and user codes
– Activate the keypad using the ON/ Enter key
– Press Function
The Code Change menu is displayed
– Confirm your selection using ON/ Enter
Now you can use the keys 1 or 2 to scroll until the user,
whose user code should be changed, is displayed
– Confirm with ON/ Enter
– Enter the (so far) valid (old) code and press ON/ Enter
– Enter the new code and confirm with ON/ Enter
– Repeat your entry and confirm it again with ON/ Enter.
After a successful entry, “Data has been saved” is displayed
Menu Sprache/ Language
Language setup
– Activate the keypad using ON/ Enter
– Press Function, the Code Change menu is displayed
– Scroll using the 2 until reaching the appropriate menu item
– Confirm with ON/ Enter
– Scroll using the keys 1 or 2 until the required language is displayed
– Confirm with ON/ Enter
Menu Administrator
Various submenus are available under the
Administrator menu.
– Activate the keypad using the ON/ Enter key
– Press Function, the Code Change menu is displayed
– Scroll using the 2 until reaching the appropriate menu item
– Confirm with ON/ Enter
– You can now use the scroll function to choose the following submenus:
Submenu Create user
– Confirm with ON/ Enter. Now you can choose between entering a user
code, programming an E-KEY or a fingerscan (fingerscan only for TSE
5012 or, with a keypad, TSE 6112 FS), or a transponder (available only
for the TSE 6000 series).
– Scroll until reaching the appropriate function and confirm with ON / Enter
· Create: Code
– Enter the administrator code in order to acquire the
authorization for programming
– The next free memory cell is indicated (e.g. USER.003)
– Enter the 6-digit code and confirm 2 x with ON/ Enter
– “Data has been saved” is displayed
· Create: E-KEY
– Enter the administrator code in order to acquire the authorization for
programming
– The next free memory cell is indicated (e.g. USER.003), press ON/Enter
– Bring the E-KEY into the programming mode (see the E-KEY instructions)
– Then confirm 2 x with ON/ Enter
– “Data has been saved” is displayed
· Create: Fingerscan
(Only for TSE 5012 and TSE 6112 Keypad FS)
– Enter the administrator code in order to acquire the authorization
for programming
– “Register finger” is displayed
– Move the finger to be registered several times straight over
the sensor (the number of attempts is indicated on the display)
– “User_XXX_FP successfully registered” is displayed
· Create: Transponder
This function is available only for the TSE 6000 System series.
Submenu Assign E-KEY
Using this function, you can subsequently assign an E-KEY radio code to an
already existing user. For this purpose, proceed as follows:
– Enter the administrator code in order to acquire the authorization for
programming
– Scroll until reaching the user, to whom you intend to assign an E-KEY,
and confirm 2 × with ON/ Enter
– Bring the E-KEY into the programming mode (see the E-KEY instructions)
– Once the E-KEY is in the programming mode, confirm with ON/ Enter
– “Data has been saved” is displayed
Submenu Delete
Using this menu, you can delete a user, an E-KEY or a transponder (inactive).
– Scroll until reaching the appropriate menu and confirm it with ON / Enter
– Enter your administrator code
– Scroll till reaching the user or the ident medium (E-KEY) you wish
to delete and confirm your selection 2 x with ON/ Enter.
– “Data record has been deleted” is displayed
Submenu Time functions
This is intended for setting the time and date
· Setting the time:
– Select the function with ON/ Enter
– Enter the hour (2 digits), confirm with ON/ Enter
– Enter the minutes (2 digits), confirm with ON/ Enter
– The display indicates: “Data has been saved”
· Setting the date:
– Select the function with ON/ Enter
– Enter the day (2 digits), confirm with ON/ Enter
– Enter the month (2 digits), confirm with ON/ Enter
– Enter the year (2 digits), confirm with ON/ Enter
– The display indicates: “Data has been saved”
Submenu TSE Setup
General system settings
· Radio channel
The radio channel can be set up here (12 channels to select from).
This might be required when the radio channel is already used by another
application, e.g. WLAN, which can possibly lead to interference. In such case,
please select another channel with a spacing of at least 3 channels.
· Priority
In case the door cannot be opened after several attempts with the E-KEY, the
priority of the door can be increased by this function. Conversely, it might be
advisable in such a case to reduce the priority of doors in a direct vicinity.
· Reorganize
The use of this function is recommended when several users have been
deleted.
· Install
After a replacement of the cylinder or the keypad, the two units have to be
newly aligned, so that they can resume communication.
Installation of a keypad or a cylinder
– Activate the keypad using ON/ Enter
– Press Function, the “Code Change” menu is displayed
– Now you can use the keys 1 or 2 to scroll until reaching the Administrator
menu
– Confirm with ON/ Enter
– Now you can use 1or 2to scroll until reaching the Admin.
TSE Setup menu
– Confirm with ON/ Enter
– Now you can use 1or 2to scroll until reaching the Admin.
Setup Register menu
– Enter the admin code of the unit to be registered
– Confirm with ON/ Enter
– “Data has been saved” is displayed after a successful registration

TSE BUSINESS 5000 English |7
Attention: Make sure that no other powered TSE unit is placed within a
direct reach of the device when registering a new keypad of a new cylinder,
as such unit could mistakenly be addressed instead of the intended one.
When in doubt, disconnect such units from power.
Submenu FS reset
(Only for TSE 5012 and TSE 6112 Keypad FS) All stored fingerprints are
deleted, however, the corresponding users are retained. Please select this
menu and follow the instructions on the display in case of repeated errors
related to the use of fingerscans.
Menu E-KEY synchronization
In this menu, the channel of the E-KEY can be adapted to the channel of the
input unit. This function is necessary when the radio channel of the cylinder
is modified, although E-KEYs with the old channel setup are still in use.
– Press ON/ Enter
– Bring the E-KEY into the programming mode (see the E-KEY instructions)
– “Data has been saved” is displayed
Menu Info
The version and serial number of the system are displayed using this
function. For security reasons, the complete serial number is indicated only in
the administrator mode. Enter the administrator code for this purpose.
TSE E-KEY user instructions
The E-KEY is intended as radio transmitter for releasing the cylinder. The
E-KEY can be subsequently programmed by means of a keypad or of a
TSE software. The radio range of the E-KEY is up to 3 m. The principle of
its function is similar to that of a car locking system. The cylinder can be
controlled when the button is pressed once.
Functions of E-KEY
Door opening:
– Press 1 x briefly, green LED flashes
– Automatic function (only together with a keypad)
Hold the button pressed for 6 seconds, green LED flashes
briefly 2 × in a row
– Permanent mode (only together with optional software) Press the button
2 x, the green LED flashes always 2 x in a row per pressed button
In the automatic mode the door can be opened by pressing the ON button
on the keypad. For this purpose, the E-KEY must be within the radio range.
This function will be deactivated automatically after a period of 15 minutes.
In the permanent mode, the door is unlocked for a period defined in the
software without the need for entry of a code. When entering an opening
code during this period, the permanent release will be deactivated.
Programming mode:
The programming mode has three purposes:
– Registration of an E-KEY by means of a keypad or of the TSE software
– Synchronization of the radio signal set up in the E-KEY with
the channel set in the lock
– Searching for the E-KEY within the TSE software
Programming E-KEY
When programming the E-KEY for the first time, please press the button
once (green LED flashes) when being required to do so by the keypad or
by the software. When programming the E-KEY later on, please keep the
button pressed for a period of 10 seconds, until the green LED flashes three
times in a row. Then release the button.
Remarks
In case the door opens with a delay of 3 to 7 seconds after the button on
the E-KEY is pressed once, and the red LED flashes, the battery (CR2032)
in the E-KEY should be replaced immediately. In case the door opens with
a delay of 3 to 7 seconds after the button on the E-KEY is pressed once,
and the red LED does not flash, the batteries (2x 1.5V LR06 alkaline) in the
cylinder should be replaced. This applies also to the keypad, if installed.
E-KEY battery replacement
1Open the housing cover by carefully forcing open the detent lugs.
2Lift the silicon pad and replace the battery.
3
Clap the silicon pad back and close the cover.
1 32
Keypad installation
1Determine the installation place for the keypad. Make a test at the required
installation location. Enter the opening code (e.g. pin code, fingerscan...) and
check that the lock opens. After a successful test,
the keypad can be installed. You can then decide
whether you want to attach
the keypad directly on the wall or whether to attach
the base plate first. The base plate can be screwed on
the wall. The slotted holes permit an exact aligning
of the plate.
2Then the keypad can be attached onto the base plate using adhesive tape.
Take care that the salient lug of the base plate engages into the keypad as
illustrated. Alternatively, you can also stick the keypad directly onto the wall.
Make a function test of the unit with the door open. For this purpose, enter
a valid opening code (e.g. pin code, fingerscan, ...) several times.
Keypad battery replacement
Below, a battery replacement for the TSE 6111 keypad is described. The
procedure is similar for all other keypads.
Remove the case cover on the bottom by loosening the 4 screws (PH1).
The 4 Mignon batteries are placed in the cover and can be pulled out by
moving them down.
When inserting the new batteries, be careful to observe the correct
polarity, which is indicated on the inner part of the cover.

TSE BUSINESS 5000 English |8
Cleaning
Thanks to its surface finish, almost no dirt rests on the keypad. Dust or dirt
can be removed from the surfaces using a damp cloth.
No spirituous (Spiritus, SIDOLIN®etc.) or aggressive detergents
(acetone etc.) must be used, as this can lead to damage of the surface
or the sensor.
Assembly manual for TSE Cylinder
The installation of the TSE cylinder is described below.
Please read this Assembly Manual carefully before the assembly and then
store it in a safe place.
The cylinder has a special detent system offering you the possibility of using
the cylinder for doors up to a thickness of 120 mm (60/60 mm, measured at
the central detent bolt). No prior adjustment is necessary.
Attention:
Be careful to not bang the knob anywhere, as the knob can break in
such case. The lock should not be greased or oiled.
An incorporated locking screw in each knob is to fix the rotary knobs.
Attention: Never pull the inner knob completely from the shaft,
as this might cause damage of the electronics! The locking screw ,
which ensures securing the detent on the shaft may be loosened
only lightly and it always remains in the plastic knob, providing (for)
protection against pulling out!
Outer side Inner side
Outer knob Inner knob
Cover Adapter 2 Adapter 1 Detent bolt Locking screw
for fixing
onto the shaft
Remark
The base size of the cylinder is 30 mm per side. When delivered, the cylinder
is completely collapsed (the smallest door thickness). Before you insert the
cylinder into the door, you should adjust it to your door thickness.
When installing the cylinder, proceed as follows:
1Take a rough measurement of the door thickness (incl. fittings)
2Pull the outer knob from the shaft, move the inner knob over the detent
system (spacing 2.85 mm) to the required dimension.
Attention: Never pull the inner knob completely from the shaft, as this
might cause damage to the electronics.
Inner knob
30mm adjustment range
Schematic illustration
of inner knob adjustment
3Depending on the door thickness, you can affix an appropriate adapter on
the outer side, in order to improve the path for the emergency key.
The following combinations are possible:
Space detent bolt /
fitting (mm) on the
outer side
Adapter 1 Adapter 2
< 43 – –
44– 53 X –
54– 60 X X
Tab. 1: Space detent bolt/mounting [mm] on the outer side and
the required adapter.
2,9× 16 Adapter 2
M2× 10 Adapter 1
4Move the TSE cylinder from inside to outside through the mortise lock
into the door and then tighten the detent bolt.
5Shift the inner knob over the shaft until attaining the required
dimension. Please make sure that the clearance between the rotary
knob and the door mounting is at least 1 mm. Then fix the rotary
knob using the hex key.
6Before you fix the outer knob, please consider whether you wish to use
the attached cover panel for the profile cylinder section. If so, remove the
protective sheet and fix the cover panel onto the lock section.
7Shift the outer knob into the required position on the shaft and fix it with
a clearance of at least 1 mm from the mounting using the hex!
8The function test must be made with the door open.
Schematic
illustration of an
assembled cylinder
incl. the two
adapter parts.
Systematic
illustration
of adapter
fixing
X: selection
–: not provided

TSE BUSINESS 5000 English |9
Replacement of batteries – knob (inner side)
1Using the attached hex key, loose the top locking screw on the cylinder
cover. It can be turned out only up to the opening of the cover and will
not fall out.
2Open the cover
3Replace the batteries. Make sure the batteries are inserted with a correct
polarity, indicated at the marked point on the housing.
4Replace the cover.
Emergency key function (outer side)
Using the mechanical emergency key, you can provide access in case of
failure of the system.
1Swing the emergency key open and then insert it into the indicted slot in
the cover panel.
2Turn the key 90° clockwise. If required, move the outer knob slightly to
the right and left in order to release the mechanism.
3Turn the outer knob. The lock opens when fully turned at the latest.
Turn the key to its initial position and take it out. To close the emergency
lock, the knob shall be turned twice fully in both directions.
Table of contents
Other BURG WATCHER Door Lock manuals